smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.0-STABLE amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Family:     Seagate Barracuda 7200.7 and 7200.7 Plus
Device Model:     ST380013AS
Serial Number:    --
Firmware Version: 3.18
User Capacity:    80,026,361,856 bytes [80.0 GB]
Sector Size:      512 bytes logical/physical
Device is:        In smartctl database 7.3/5319
ATA Version is:   ATA/ATAPI-6 T13/1410D revision 2
Local Time is:    Mon Jun 27 16:12:56 2022 +01
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is:   Unavailable
APM feature is:   Unavailable
Rd look-ahead is: Enabled
Write cache is:   Enabled
DSN feature is:   Unavailable
ATA Security is:  Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Unavailable

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x82)	Offline data collection activity
					was completed without error.
					Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0)	The previous self-test routine completed
					without error or no self-test has ever 
					been run.
Total time to complete Offline 
data collection: 		(  430) seconds.
Offline data collection
capabilities: 			 (0x5b) SMART execute Offline immediate.
					Auto Offline data collection on/off support.
					Suspend Offline collection upon new
					command.
					Offline surface scan supported.
					Self-test supported.
					No Conveyance Self-test supported.
					Selective Self-test supported.
SMART capabilities:            (0x0003)	Saves SMART data before entering
					power-saving mode.
					Supports SMART auto save timer.
Error logging capability:        (0x01)	Error logging supported.
					No General Purpose Logging support.
Short self-test routine 
recommended polling time: 	 (   1) minutes.
Extended self-test routine
recommended polling time: 	 (  58) minutes.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAGS    VALUE WORST THRESH FAIL RAW_VALUE
  1 Raw_Read_Error_Rate     POSR--   062   053   006    -    219458470
  3 Spin_Up_Time            PO----   097   097   000    -    0
  4 Start_Stop_Count        -O--CK   100   100   020    -    5
  5 Reallocated_Sector_Ct   PO--CK   100   100   036    -    0
  7 Seek_Error_Rate         POSR--   068   060   030    -    249567698478
  9 Power_On_Hours          -O--CK   091   091   000    -    8282
 10 Spin_Retry_Count        PO--C-   100   100   097    -    0
 12 Power_Cycle_Count       -O--CK   098   098   020    -    2602
194 Temperature_Celsius     -O---K   039   056   000    -    39
195 Hardware_ECC_Recovered  -O-RC-   062   052   000    -    219458470
197 Current_Pending_Sector  -O--C-   100   100   000    -    7
198 Offline_Uncorrectable   ----C-   100   100   000    -    7
199 UDMA_CRC_Error_Count    -OSRCK   200   131   000    -    611
200 Multi_Zone_Error_Rate   ------   100   253   000    -    0
202 Data_Address_Mark_Errs  -O--CK   100   253   000    -    0
                            ||||||_ K auto-keep
                            |||||__ C event count
                            ||||___ R error rate
                            |||____ S speed/performance
                            ||_____ O updated online
                            |______ P prefailure warning

General Purpose Log Directory not supported

SMART Log Directory Version 1 [multi-sector log support]
Address    Access  R/W   Size  Description
0x00           SL  R/O      1  Log Directory
0x01           SL  R/O      1  Summary SMART error log
0x02           SL  R/O      5  Comprehensive SMART error log
0x03           SL  R/O      5  Ext. Comprehensive SMART error log
0x06           SL  R/O      1  SMART self-test log
0x07           SL  R/O      1  Extended self-test log
0x09           SL  R/W      1  Selective self-test log
0x20           SL  R/O      1  Streaming performance log [OBS-8]
0x21           SL  R/O      1  Write stream error log
0x22           SL  R/O      1  Read stream error log
0x23           SL  R/O      1  Delayed sector log [OBS-8]
0x80-0x9f      SL  R/W     16  Host vendor specific log
0xa0           SL  VS       1  Device vendor specific log
0xa1           SL  VS      20  Device vendor specific log
0xa2           SL  VS     101  Device vendor specific log
0xa8           SL  VS      20  Device vendor specific log
0xa9           SL  VS       1  Device vendor specific log

SMART Extended Comprehensive Error Log (GP Log 0x03) not supported

SMART Error Log Version: 1
ATA Error Count: 1282 (device log contains only the most recent five errors)
	CR = Command Register [HEX]
	FR = Features Register [HEX]
	SC = Sector Count Register [HEX]
	SN = Sector Number Register [HEX]
	CL = Cylinder Low Register [HEX]
	CH = Cylinder High Register [HEX]
	DH = Device/Head Register [HEX]
	DC = Device Command Register [HEX]
	ER = Error register [HEX]
	ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 1282 occurred at disk power-on lifetime: 5937 hours (247 days + 9 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  84 51 f0 ff ff ff ef  Error: ABRT at LBA = 0x0fffffff = 268435455

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  c4 d8 00 df 20 60 e0 00      00:15:46.588  READ MULTIPLE
  c4 d8 00 df 1f 60 e0 00      00:15:46.557  READ MULTIPLE
  c4 d8 00 df 1e 60 e0 00      00:15:46.526  READ MULTIPLE
  c4 d8 00 df 1d 60 e0 00      00:15:46.495  READ MULTIPLE
  c4 d8 68 37 1c 60 e0 00      00:15:46.463  READ MULTIPLE

Error 1281 occurred at disk power-on lifetime: 5937 hours (247 days + 9 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  84 51 02 28 c0 1b e0  Error: ICRC, ABRT 2 sectors at LBA = 0x001bc028 = 1818664

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  c8 00 13 17 c0 1b e0 00      00:15:12.552  READ DMA
  c8 00 1a fd bf 1b e0 00      00:15:12.551  READ DMA
  c8 00 26 d7 bf 1b e0 00      00:15:12.543  READ DMA
  c8 00 2c 94 5a 2f e0 00      00:15:12.543  READ DMA
  c8 00 05 8f 5a 2f e0 00      00:15:12.527  READ DMA

Error 1280 occurred at disk power-on lifetime: 5937 hours (247 days + 9 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  84 51 01 e6 c5 1c e0  Error: ICRC, ABRT 1 sectors at LBA = 0x001cc5e6 = 1885670

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  c8 00 12 d5 c5 1c e0 00      00:14:42.071  READ DMA
  c8 00 2e a7 c5 1c e0 00      00:14:42.070  READ DMA
  c8 00 11 96 c5 1c e0 00      00:14:42.070  READ DMA
  c8 00 2f 67 c5 1c e0 00      00:14:42.069  READ DMA
  c8 00 10 57 c5 1c e0 00      00:14:42.805  READ DMA

Error 1279 occurred at disk power-on lifetime: 5937 hours (247 days + 9 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  84 51 00 e6 c4 1c e0  Error: ICRC, ABRT at LBA = 0x001cc4e6 = 1885414

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  c8 00 0e d9 c4 1c e0 00      00:14:42.071  READ DMA
  c8 00 32 a7 c4 1c e0 00      00:14:42.070  READ DMA
  c8 00 0d 9a c4 1c e0 00      00:14:42.070  READ DMA
  c8 00 33 67 c4 1c e0 00      00:14:42.069  READ DMA
  c8 00 0c 5b c4 1c e0 00      00:14:42.069  READ DMA

Error 1278 occurred at disk power-on lifetime: 5937 hours (247 days + 9 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER ST SC SN CL CH DH
  -- -- -- -- -- -- --
  84 51 23 84 be 1c e0  Error: ICRC, ABRT 35 sectors at LBA = 0x001cbe84 = 1883780

  Commands leading to the command that caused the error were:
  CR FR SC SN CL CH DH DC   Powered_Up_Time  Command/Feature_Name
  -- -- -- -- -- -- -- --  ----------------  --------------------
  c8 00 34 73 be 1c e0 00      00:14:13.298  READ DMA
  c8 00 0c 67 be 1c e0 00      00:14:13.069  READ DMA
  c8 00 33 34 be 1c e0 00      00:13:44.631  READ DMA
  c8 00 0d 27 be 1c e0 00      00:13:44.630  READ DMA
  c8 00 32 f5 bd 1c e0 00      00:13:44.622  READ DMA

SMART Extended Self-test Log (GP Log 0x07) not supported

SMART Self-test log structure revision number 1
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Short offline       Completed without error       00%       327         -
# 2  Extended offline    Interrupted (host reset)      80%       308         -
# 3  Short captive       Completed without error       00%       308         -
# 4  Extended offline    Interrupted (host reset)      80%       308         -
# 5  Short offline       Aborted by host               40%       308         -
# 6  Extended offline    Interrupted (host reset)      90%       308         -
# 7  Conveyance offline  Fatal or unknown error        00%       308         0
# 8  Short offline       Completed without error       00%       240         -
# 9  Short offline       Completed without error       00%       237         -
#10  Short offline       Completed without error       00%       236         -
#11  Short offline       Completed: read failure       90%       150         19684179

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

SCT Commands not supported

Device Statistics (GP/SMART Log 0x04) not supported

Pending Defects log (GP Log 0x0c) not supported

SATA Phy Event Counters (GP Log 0x11) not supported