smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p19-HBSD amd64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Family:     Seagate Barracuda 7200.10
Device Model:     ST380815AS
Serial Number:    --
Firmware Version: 4.ADA
User Capacity:    80,000,000,000 bytes [80.0 GB]
Sector Size:      512 bytes logical/physical
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   ATA/ATAPI-7 (minor revision not indicated)
Local Time is:    Wed Sep  1 21:12:33 2021 MST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is:   Disabled
APM feature is:   Unavailable
Rd look-ahead is: Enabled
Write cache is:   Enabled
DSN feature is:   Unavailable
ATA Security is:  Disabled, frozen [SEC2]
Wt Cache Reorder: Unavailable

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x82)	Offline data collection activity
					was completed without error.
					Auto Offline Data Collection: Enabled.
Self-test execution status:      ( 121)	The previous self-test completed having
					the read element of the test failed.
Total time to complete Offline 
data collection: 		(  430) seconds.
Offline data collection
capabilities: 			 (0x5b) SMART execute Offline immediate.
					Auto Offline data collection on/off support.
					Suspend Offline collection upon new
					command.
					Offline surface scan supported.
					Self-test supported.
					No Conveyance Self-test supported.
					Selective Self-test supported.
SMART capabilities:            (0x0003)	Saves SMART data before entering
					power-saving mode.
					Supports SMART auto save timer.
Error logging capability:        (0x01)	Error logging supported.
					General Purpose Logging supported.
Short self-test routine 
recommended polling time: 	 (   2) minutes.
Extended self-test routine
recommended polling time: 	 (  27) minutes.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAGS    VALUE WORST THRESH FAIL RAW_VALUE
  1 Raw_Read_Error_Rate     POSR--   100   253   006    -    0
  3 Spin_Up_Time            PO----   098   097   070    -    0
  4 Start_Stop_Count        -O--CK   092   092   020    -    8304
  5 Reallocated_Sector_Ct   PO--CK   092   092   036    -    330
  7 Seek_Error_Rate         POSR--   086   060   030    -    443419823
  9 Power_On_Hours          -O--CK   046   046   000    -    47924
 10 Spin_Retry_Count        PO--C-   100   100   097    -    0
 12 Power_Cycle_Count       -O--CK   092   092   020    -    8344
187 Reported_Uncorrect      -O--CK   001   001   000    -    4656
189 High_Fly_Writes         -O-RCK   100   100   000    -    0
190 Airflow_Temperature_Cel -O---K   057   049   045    -    43 (Min/Max 39/43)
194 Temperature_Celsius     -O---K   043   051   000    -    43 (0 17 0 0 0)
195 Hardware_ECC_Recovered  -O-RC-   064   057   000    -    23667577
197 Current_Pending_Sector  -O--C-   001   001   000    -    6407
198 Offline_Uncorrectable   ----C-   001   001   000    -    6407
199 UDMA_CRC_Error_Count    -OSRCK   200   200   000    -    0
200 Multi_Zone_Error_Rate   ------   100   253   000    -    0
202 Data_Address_Mark_Errs  -O--CK   100   253   000    -    0
                            ||||||_ K auto-keep
                            |||||__ C event count
                            ||||___ R error rate
                            |||____ S speed/performance
                            ||_____ O updated online
                            |______ P prefailure warning

General Purpose Log Directory Version 1
SMART           Log Directory Version 1 [multi-sector log support]
Address    Access  R/W   Size  Description
0x00       GPL,SL  R/O      1  Log Directory
0x01       GPL,SL  R/O      1  Summary SMART error log
0x02       GPL,SL  R/O      5  Comprehensive SMART error log
0x03       GPL,SL  R/O      5  Ext. Comprehensive SMART error log
0x06       GPL,SL  R/O      1  SMART self-test log
0x07       GPL,SL  R/O      1  Extended self-test log
0x09       GPL,SL  R/W      1  Selective self-test log
0x10       GPL,SL  R/O      1  NCQ Command Error log
0x11       GPL,SL  R/O      1  SATA Phy Event Counters log
0x20       GPL,SL  R/O      1  Streaming performance log [OBS-8]
0x21       GPL,SL  R/O      1  Write stream error log
0x22       GPL,SL  R/O      1  Read stream error log
0x23       GPL,SL  R/O      1  Delayed sector log [OBS-8]
0x80-0x9f  GPL,SL  R/W     16  Host vendor specific log
0xa0       GPL,SL  VS       1  Device vendor specific log
0xa1       GPL,SL  VS      20  Device vendor specific log
0xa2       GPL,SL  VS     101  Device vendor specific log
0xa8       GPL,SL  VS      20  Device vendor specific log
0xa9       GPL,SL  VS       1  Device vendor specific log
0xe0       GPL,SL  R/W      1  SCT Command/Status
0xe1       GPL,SL  R/W      1  SCT Data Transfer
0xff       GPL     -    23040  Reserved

SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
Device Error Count: 4659 (device log contains only the most recent 20 errors)
	CR     = Command Register
	FEATR  = Features Register
	COUNT  = Count (was: Sector Count) Register
	LBA_48 = Upper bytes of LBA High/Mid/Low Registers ]  ATA-8
	LH     = LBA High (was: Cylinder High) Register    ]   LBA
	LM     = LBA Mid (was: Cylinder Low) Register      ] Register
	LL     = LBA Low (was: Sector Number) Register     ]
	DV     = Device (was: Device/Head) Register
	DC     = Device Control Register
	ER     = Error register
	ST     = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 4659 [18] occurred at disk power-on lifetime: 47865 hours (1994 days + 9 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER -- ST COUNT  LBA_48  LH LM LL DV DC
  -- -- -- == -- == == == -- -- -- -- --
  40 -- 51 00 00 00 08 c5 00 61 bd e8 00  Error: UNC at LBA = 0x8cd0061bd = 37799092669

  Commands leading to the command that caused the error were:
  CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_Name
  -- == -- == -- == == == -- -- -- -- --  ---------------  --------------------
  c8 00 00 00 f8 00 08 c5 00 61 08 e8 00     00:24:44.826  READ DMA
  c8 00 00 00 70 00 08 c5 00 61 00 e8 00     00:24:44.825  READ DMA
  27 00 00 00 00 00 00 00 00 00 00 e0 00     00:24:44.823  READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
  ec 00 00 01 00 00 ff ff 00 ff ff a0 00     00:24:44.823  IDENTIFY DEVICE
  ef 00 03 00 46 00 ff ff 00 ff ff a0 00     00:24:44.822  SET FEATURES [Set transfer mode]

Error 4658 [17] occurred at disk power-on lifetime: 47865 hours (1994 days + 9 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER -- ST COUNT  LBA_48  LH LM LL DV DC
  -- -- -- == -- == == == -- -- -- -- --
  40 -- 51 00 00 00 08 c5 00 61 bd e8 00  Error: UNC at LBA = 0x8cd0061bd = 37799092669

  Commands leading to the command that caused the error were:
  CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_Name
  -- == -- == -- == == == -- -- -- -- --  ---------------  --------------------
  c8 00 00 01 00 00 08 c5 00 61 00 e8 00     00:24:44.826  READ DMA
  c8 00 00 01 00 00 08 c4 00 61 00 e8 00     00:24:44.825  READ DMA
  c8 00 00 01 00 00 00 0b 00 00 00 e0 00     00:24:44.823  READ DMA
  c8 00 00 01 00 00 00 0a 00 00 00 e0 00     00:24:44.823  READ DMA
  c8 00 00 00 f0 00 00 09 00 00 10 e0 00     00:24:44.822  READ DMA

Error 4657 [16] occurred at disk power-on lifetime: 47865 hours (1994 days + 9 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER -- ST COUNT  LBA_48  LH LM LL DV DC
  -- -- -- == -- == == == -- -- -- -- --
  40 -- 51 00 00 00 08 c5 00 61 bd e8 00  Error: UNC at LBA = 0x8cd0061bd = 37799092669

  Commands leading to the command that caused the error were:
  CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_Name
  -- == -- == -- == == == -- -- -- -- --  ---------------  --------------------
  c8 00 00 00 08 00 08 c5 00 61 b8 e8 00     00:24:41.177  READ DMA
  c8 00 00 00 08 00 08 c5 00 61 b0 e8 00     00:24:41.177  READ DMA
  c8 00 00 00 08 00 08 c5 00 61 a8 e8 00     00:24:41.176  READ DMA
  c8 00 00 00 08 00 08 c5 00 61 a0 e8 00     00:24:41.176  READ DMA
  c8 00 00 00 08 00 08 c5 00 61 98 e8 00     00:24:41.176  READ DMA

Error 4656 [15] occurred at disk power-on lifetime: 47865 hours (1994 days + 9 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER -- ST COUNT  LBA_48  LH LM LL DV DC
  -- -- -- == -- == == == -- -- -- -- --
  40 -- 51 00 00 00 08 c5 00 61 bd e8 00  Error: UNC at LBA = 0x8cd0061bd = 37799092669

  Commands leading to the command that caused the error were:
  CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_Name
  -- == -- == -- == == == -- -- -- -- --  ---------------  --------------------
  c8 00 00 00 f0 00 08 c5 00 61 10 e8 00     00:24:51.517  READ DMA
  e7 00 00 01 00 00 01 f7 00 80 be a0 00     00:24:51.515  FLUSH CACHE
  c8 00 00 00 08 00 08 c5 00 61 08 e8 00     00:24:51.514  READ DMA
  c8 00 00 01 00 00 00 15 00 01 98 e0 00     00:24:51.512  READ DMA
  c8 00 00 01 00 00 00 14 00 01 98 e0 00     00:24:51.511  READ DMA

Error 4655 [14] occurred at disk power-on lifetime: 47865 hours (1994 days + 9 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER -- ST COUNT  LBA_48  LH LM LL DV DC
  -- -- -- == -- == == == -- -- -- -- --
  40 -- 51 00 00 00 08 c5 00 61 bd e8 00  Error: UNC at LBA = 0x8cd0061bd = 37799092669

  Commands leading to the command that caused the error were:
  CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_Name
  -- == -- == -- == == == -- -- -- -- --  ---------------  --------------------
  c8 00 00 00 f8 00 08 c5 00 61 08 e8 00     00:24:44.826  READ DMA
  c8 00 00 00 70 00 08 c5 00 61 00 e8 00     00:24:44.825  READ DMA
  27 00 00 00 00 00 00 00 00 00 00 e0 00     00:24:44.823  READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
  ec 00 00 01 00 00 ff ff 00 ff ff a0 00     00:24:44.823  IDENTIFY DEVICE
  ef 00 03 00 46 00 ff ff 00 ff ff a0 00     00:24:44.822  SET FEATURES [Set transfer mode]

Error 4654 [13] occurred at disk power-on lifetime: 47865 hours (1994 days + 9 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER -- ST COUNT  LBA_48  LH LM LL DV DC
  -- -- -- == -- == == == -- -- -- -- --
  40 -- 51 00 00 00 08 c5 00 61 bd e8 00  Error: UNC at LBA = 0x8cd0061bd = 37799092669

  Commands leading to the command that caused the error were:
  CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_Name
  -- == -- == -- == == == -- -- -- -- --  ---------------  --------------------
  c8 00 00 01 00 00 08 c5 00 61 00 e8 00     00:24:44.826  READ DMA
  c8 00 00 01 00 00 08 c4 00 61 00 e8 00     00:24:44.825  READ DMA
  c8 00 00 01 00 00 00 0b 00 00 00 e0 00     00:24:44.823  READ DMA
  c8 00 00 01 00 00 00 0a 00 00 00 e0 00     00:24:44.823  READ DMA
  c8 00 00 00 f0 00 00 09 00 00 10 e0 00     00:24:44.822  READ DMA

Error 4653 [12] occurred at disk power-on lifetime: 47865 hours (1994 days + 9 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER -- ST COUNT  LBA_48  LH LM LL DV DC
  -- -- -- == -- == == == -- -- -- -- --
  40 -- 51 00 00 00 08 c5 00 61 bd e8 00  Error: UNC at LBA = 0x8cd0061bd = 37799092669

  Commands leading to the command that caused the error were:
  CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_Name
  -- == -- == -- == == == -- -- -- -- --  ---------------  --------------------
  c8 00 00 00 08 00 08 c5 00 61 b8 e8 00     00:24:41.177  READ DMA
  c8 00 00 00 08 00 08 c5 00 61 b0 e8 00     00:24:41.177  READ DMA
  c8 00 00 00 08 00 08 c5 00 61 a8 e8 00     00:24:41.176  READ DMA
  c8 00 00 00 08 00 08 c5 00 61 a0 e8 00     00:24:41.176  READ DMA
  c8 00 00 00 08 00 08 c5 00 61 98 e8 00     00:24:41.176  READ DMA

Error 4652 [11] occurred at disk power-on lifetime: 47865 hours (1994 days + 9 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER -- ST COUNT  LBA_48  LH LM LL DV DC
  -- -- -- == -- == == == -- -- -- -- --
  40 -- 51 00 00 00 08 c5 00 61 bd e8 00  Error: UNC at LBA = 0x8cd0061bd = 37799092669

  Commands leading to the command that caused the error were:
  CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_Name
  -- == -- == -- == == == -- -- -- -- --  ---------------  --------------------
  c8 00 00 00 f0 00 08 c5 00 61 10 e8 00     00:24:51.517  READ DMA
  e7 00 00 01 00 00 01 f7 00 80 be a0 00     00:24:51.515  FLUSH CACHE
  c8 00 00 00 08 00 08 c5 00 61 08 e8 00     00:24:51.514  READ DMA
  c8 00 00 01 00 00 00 15 00 01 98 e0 00     00:24:51.512  READ DMA
  c8 00 00 01 00 00 00 14 00 01 98 e0 00     00:24:51.511  READ DMA

SMART Extended Self-test Log Version: 1 (1 sectors)
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Short offline       Completed: read failure       90%     47903         233246929569213
# 2  Short offline       Completed: read failure       90%     47903         233203979896253
# 3  Extended offline    Completed: read failure       90%     47900         8478406067645
# 4  Short offline       Completed: read failure       80%     47810         160945449055725
# 5  Short offline       Completed: read failure       90%     47809         233268403969653
# 6  Short offline       Completed without error       00%     47750         -
# 7  Short offline       Completed without error       00%     47750         -
# 8  Short offline       Completed without error       00%         0         -

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

SCT Commands not supported

Device Statistics (GP/SMART Log 0x04) not supported

Pending Defects log (GP Log 0x0c) not supported

SATA Phy Event Counters (GP Log 0x11)
ID      Size     Value  Description
0x000a  2            5  Device-to-host register FISes sent due to a COMRESET
0x0001  2            0  Command failed due to ICRC error
0x0003  2            0  R_ERR response for device-to-host data FIS
0x0004  2            0  R_ERR response for host-to-device data FIS
0x0006  2            0  R_ERR response for device-to-host non-data FIS
0x0007  2            0  R_ERR response for host-to-device non-data FIS