smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p6 amd64] (local build)
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org

=== START OF INFORMATION SECTION ===
Model Family:     Seagate Barracuda 7200.14 (AF)
Device Model:     ST500DM002-1BC142
Serial Number:    --
LU WWN Device Id: 5 000c50 ...
Firmware Version: JC4B
User Capacity:    500,107,862,016 bytes [500 GB]
Sector Size:      512 bytes logical/physical
Rotation Rate:    7200 rpm
Device is:        In smartctl database [for details use: -P show]
ATA Version is:   ATA8-ACS T13/1699-D revision 4
SATA Version is:  SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is:    Fri Jul 17 22:23:08 2020 AST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM level is:     208 (intermediate), recommended: 208
APM feature is:   Unavailable
Rd look-ahead is: Enabled
Write cache is:   Enabled
DSN feature is:   Unavailable
ATA Security is:  Disabled, frozen [SEC2]
Wt Cache Reorder: Unknown

=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

General SMART Values:
Offline data collection status:  (0x82)	Offline data collection activity
					was completed without error.
					Auto Offline Data Collection: Enabled.
Self-test execution status:      (   0)	The previous self-test routine completed
					without error or no self-test has ever 
					been run.
Total time to complete Offline 
data collection: 		(  600) seconds.
Offline data collection
capabilities: 			 (0x7b) SMART execute Offline immediate.
					Auto Offline data collection on/off support.
					Suspend Offline collection upon new
					command.
					Offline surface scan supported.
					Self-test supported.
					Conveyance Self-test supported.
					Selective Self-test supported.
SMART capabilities:            (0x0003)	Saves SMART data before entering
					power-saving mode.
					Supports SMART auto save timer.
Error logging capability:        (0x01)	Error logging supported.
					General Purpose Logging supported.
Short self-test routine 
recommended polling time: 	 (   1) minutes.
Extended self-test routine
recommended polling time: 	 (  83) minutes.
Conveyance self-test routine
recommended polling time: 	 (   2) minutes.
SCT capabilities: 	       (0x103f)	SCT Status supported.
					SCT Error Recovery Control supported.
					SCT Feature Control supported.
					SCT Data Table supported.

SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME          FLAGS    VALUE WORST THRESH FAIL RAW_VALUE
  1 Raw_Read_Error_Rate     POSR--   111   099   006    -    29970045
  3 Spin_Up_Time            PO----   100   100   000    -    0
  4 Start_Stop_Count        -O--CK   089   089   020    -    11814
  5 Reallocated_Sector_Ct   PO--CK   100   100   036    -    0
  7 Seek_Error_Rate         POSR--   082   060   030    -    190217706
  9 Power_On_Hours          -O--CK   088   088   000    -    10815
 10 Spin_Retry_Count        PO--C-   100   100   097    -    0
 12 Power_Cycle_Count       -O--CK   089   089   020    -    11989
183 Runtime_Bad_Block       -O--CK   099   099   000    -    1
184 End-to-End_Error        -O--CK   100   100   099    -    0
187 Reported_Uncorrect      -O--CK   022   022   000    -    78
188 Command_Timeout         -O--CK   100   088   000    -    1 1 3006
189 High_Fly_Writes         -O-RCK   100   100   000    -    0
190 Airflow_Temperature_Cel -O---K   067   052   045    -    33 (Min/Max 28/38)
194 Temperature_Celsius     -O---K   033   048   000    -    33 (0 21 0 0 0)
195 Hardware_ECC_Recovered  -O-RC-   035   028   000    -    29970045
197 Current_Pending_Sector  -O--C-   100   100   000    -    0
198 Offline_Uncorrectable   ----C-   100   100   000    -    0
199 UDMA_CRC_Error_Count    -OSRCK   200   200   000    -    89
240 Head_Flying_Hours       ------   100   253   000    -    28312h+18m+37.937s
241 Total_LBAs_Written      ------   100   253   000    -    3504271051
242 Total_LBAs_Read         ------   100   253   000    -    1834545530
                            ||||||_ K auto-keep
                            |||||__ C event count
                            ||||___ R error rate
                            |||____ S speed/performance
                            ||_____ O updated online
                            |______ P prefailure warning

General Purpose Log Directory Version 1
SMART           Log Directory Version 1 [multi-sector log support]
Address    Access  R/W   Size  Description
0x00       GPL,SL  R/O      1  Log Directory
0x01       GPL,SL  R/O      1  Summary SMART error log
0x02       GPL,SL  R/O      5  Comprehensive SMART error log
0x03       GPL     R/O      5  Ext. Comprehensive SMART error log
0x06       GPL,SL  R/O      1  SMART self-test log
0x07       GPL     R/O      1  Extended self-test log
0x09       GPL,SL  R/W      1  Selective self-test log
0x10       GPL     R/O      1  NCQ Command Error log
0x11       GPL     R/O      1  SATA Phy Event Counters log
0x21       GPL     R/O      1  Write stream error log
0x22       GPL     R/O      1  Read stream error log
0x80-0x9f  GPL,SL  R/W     16  Host vendor specific log
0xa1       GPL,SL  VS      20  Device vendor specific log
0xa2       GPL     VS    2248  Device vendor specific log
0xa8       GPL,SL  VS     129  Device vendor specific log
0xa9       GPL,SL  VS       1  Device vendor specific log
0xb0       GPL     VS    2928  Device vendor specific log
0xbd       GPL     VS     252  Device vendor specific log
0xbe-0xbf  GPL     VS   65535  Device vendor specific log
0xc0       GPL,SL  VS       1  Device vendor specific log
0xe0       GPL,SL  R/W      1  SCT Command/Status
0xe1       GPL,SL  R/W      1  SCT Data Transfer

SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
Device Error Count: 79 (device log contains only the most recent 20 errors)
	CR     = Command Register
	FEATR  = Features Register
	COUNT  = Count (was: Sector Count) Register
	LBA_48 = Upper bytes of LBA High/Mid/Low Registers ]  ATA-8
	LH     = LBA High (was: Cylinder High) Register    ]   LBA
	LM     = LBA Mid (was: Cylinder Low) Register      ] Register
	LL     = LBA Low (was: Sector Number) Register     ]
	DV     = Device (was: Device/Head) Register
	DC     = Device Control Register
	ER     = Error register
	ST     = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.

Error 79 [18] occurred at disk power-on lifetime: 2172 hours (90 days + 12 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER -- ST COUNT  LBA_48  LH LM LL DV DC
  -- -- -- == -- == == == -- -- -- -- --
  40 -- 51 00 00 00 00 38 43 59 20 00 00  Error: UNC at LBA = 0x38435920 = 943937824

  Commands leading to the command that caused the error were:
  CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_Name
  -- == -- == -- == == == -- -- -- -- --  ---------------  --------------------
  25 00 00 00 80 00 00 38 43 58 ca e0 00     00:22:51.373  READ DMA EXT
  35 00 00 00 48 00 00 07 b2 2d a8 e0 00     00:22:51.372  WRITE DMA EXT
  35 00 00 00 38 00 00 07 af 82 50 e0 00     00:22:51.371  WRITE DMA EXT
  25 00 00 00 80 00 00 38 43 64 04 e0 00     00:22:51.312  READ DMA EXT
  25 00 00 00 40 00 00 00 41 7c 00 e0 00     00:22:51.286  READ DMA EXT

Error 78 [17] occurred at disk power-on lifetime: 2155 hours (89 days + 19 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER -- ST COUNT  LBA_48  LH LM LL DV DC
  -- -- -- == -- == == == -- -- -- -- --
  40 -- 51 00 00 00 00 38 43 59 20 00 00  Error: UNC at LBA = 0x38435920 = 943937824

  Commands leading to the command that caused the error were:
  CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_Name
  -- == -- == -- == == == -- -- -- -- --  ---------------  --------------------
  25 00 00 00 80 00 00 38 43 58 ca e0 00     01:59:02.873  READ DMA EXT
  25 00 00 00 80 00 00 38 43 64 04 e0 00     01:59:02.862  READ DMA EXT
  25 00 00 00 80 00 00 38 43 54 68 e0 00     01:59:02.860  READ DMA EXT
  25 00 00 00 80 00 00 38 43 53 12 e0 00     01:59:02.849  READ DMA EXT
  25 00 00 00 80 00 00 39 8d f6 d8 e0 00     01:59:02.847  READ DMA EXT

Error 77 [16] occurred at disk power-on lifetime: 2155 hours (89 days + 19 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER -- ST COUNT  LBA_48  LH LM LL DV DC
  -- -- -- == -- == == == -- -- -- -- --
  40 -- 51 00 00 00 00 38 43 59 20 00 00  Error: UNC at LBA = 0x38435920 = 943937824

  Commands leading to the command that caused the error were:
  CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_Name
  -- == -- == -- == == == -- -- -- -- --  ---------------  --------------------
  25 00 00 00 80 00 00 38 43 58 ee e0 00     01:55:16.557  READ DMA EXT
  25 00 00 00 80 00 00 39 90 76 78 e0 00     01:55:16.556  READ DMA EXT
  25 00 00 00 80 00 00 38 43 6b 90 e0 00     01:55:16.546  READ DMA EXT
  25 00 00 00 80 00 00 38 43 65 fc e0 00     01:55:16.537  READ DMA EXT
  25 00 00 00 80 00 00 38 44 74 8c e0 00     01:55:16.513  READ DMA EXT

Error 76 [15] occurred at disk power-on lifetime: 2132 hours (88 days + 20 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER -- ST COUNT  LBA_48  LH LM LL DV DC
  -- -- -- == -- == == == -- -- -- -- --
  40 -- 51 00 00 00 00 38 43 59 20 00 00  Error: UNC at LBA = 0x38435920 = 943937824

  Commands leading to the command that caused the error were:
  CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_Name
  -- == -- == -- == == == -- -- -- -- --  ---------------  --------------------
  25 00 00 00 80 00 00 38 43 58 ca e0 00     00:39:02.027  READ DMA EXT
  25 00 00 00 80 00 00 38 43 64 04 e0 00     00:39:02.015  READ DMA EXT
  25 00 00 00 80 00 00 38 43 54 68 e0 00     00:39:02.013  READ DMA EXT
  25 00 00 00 80 00 00 38 43 53 12 e0 00     00:39:02.003  READ DMA EXT
  25 00 00 00 80 00 00 39 8d f6 d8 e0 00     00:39:02.000  READ DMA EXT

Error 75 [14] occurred at disk power-on lifetime: 2132 hours (88 days + 20 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER -- ST COUNT  LBA_48  LH LM LL DV DC
  -- -- -- == -- == == == -- -- -- -- --
  40 -- 51 00 00 00 00 38 43 59 20 00 00  Error: UNC at LBA = 0x38435920 = 943937824

  Commands leading to the command that caused the error were:
  CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_Name
  -- == -- == -- == == == -- -- -- -- --  ---------------  --------------------
  25 00 00 00 80 00 00 38 43 58 ee e0 00     00:35:57.796  READ DMA EXT
  25 00 00 00 80 00 00 39 90 76 78 e0 00     00:35:57.795  READ DMA EXT
  35 00 00 00 08 00 00 38 44 57 b8 e0 00     00:35:57.795  WRITE DMA EXT
  25 00 00 00 80 00 00 38 43 6b 90 e0 00     00:35:57.786  READ DMA EXT
  35 00 00 00 08 00 00 38 44 57 40 e0 00     00:35:57.785  WRITE DMA EXT

Error 74 [13] occurred at disk power-on lifetime: 2119 hours (88 days + 7 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER -- ST COUNT  LBA_48  LH LM LL DV DC
  -- -- -- == -- == == == -- -- -- -- --
  40 -- 51 00 00 00 00 38 43 59 20 00 00  Error: UNC at LBA = 0x38435920 = 943937824

  Commands leading to the command that caused the error were:
  CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_Name
  -- == -- == -- == == == -- -- -- -- --  ---------------  --------------------
  25 00 00 00 80 00 00 38 43 58 ca e0 00     04:47:48.945  READ DMA EXT
  25 00 00 00 10 00 00 39 aa c2 a0 e0 00     04:47:48.945  READ DMA EXT
  25 00 00 00 80 00 00 38 43 64 04 e0 00     04:47:48.937  READ DMA EXT
  25 00 00 00 80 00 00 38 43 54 68 e0 00     04:47:48.936  READ DMA EXT
  25 00 00 00 38 00 00 39 aa c2 68 e0 00     04:47:48.923  READ DMA EXT

Error 73 [12] occurred at disk power-on lifetime: 2119 hours (88 days + 7 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER -- ST COUNT  LBA_48  LH LM LL DV DC
  -- -- -- == -- == == == -- -- -- -- --
  40 -- 51 00 00 00 00 38 43 59 20 00 00  Error: UNC at LBA = 0x38435920 = 943937824

  Commands leading to the command that caused the error were:
  CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_Name
  -- == -- == -- == == == -- -- -- -- --  ---------------  --------------------
  25 00 00 00 80 00 00 38 43 58 ee e0 00     04:42:20.396  READ DMA EXT
  25 00 00 00 80 00 00 39 90 76 78 e0 00     04:42:20.382  READ DMA EXT
  25 00 00 00 80 00 00 38 43 6b 90 e0 00     04:42:20.375  READ DMA EXT
  25 00 00 00 80 00 00 38 43 65 fc e0 00     04:42:20.363  READ DMA EXT
  25 00 00 00 80 00 00 38 44 74 8c e0 00     04:42:20.361  READ DMA EXT

Error 72 [11] occurred at disk power-on lifetime: 2038 hours (84 days + 22 hours)
  When the command that caused the error occurred, the device was active or idle.

  After command completion occurred, registers were:
  ER -- ST COUNT  LBA_48  LH LM LL DV DC
  -- -- -- == -- == == == -- -- -- -- --
  40 -- 51 00 00 00 00 38 43 59 20 00 00  Error: UNC at LBA = 0x38435920 = 943937824

  Commands leading to the command that caused the error were:
  CR FEATR COUNT  LBA_48  LH LM LL DV DC  Powered_Up_Time  Command/Feature_Name
  -- == -- == -- == == == -- -- -- -- --  ---------------  --------------------
  25 00 00 00 80 00 00 38 43 58 ca e0 00     02:56:05.575  READ DMA EXT
  25 00 00 00 80 00 00 38 43 64 04 e0 00     02:56:05.564  READ DMA EXT
  25 00 00 00 80 00 00 38 43 54 68 e0 00     02:56:05.562  READ DMA EXT
  25 00 00 00 80 00 00 38 43 53 12 e0 00     02:56:05.552  READ DMA EXT
  25 00 00 00 80 00 00 39 8d f6 d8 e0 00     02:56:05.549  READ DMA EXT

SMART Extended Self-test Log Version: 1 (1 sectors)
Num  Test_Description    Status                  Remaining  LifeTime(hours)  LBA_of_first_error
# 1  Extended offline    Completed without error       00%     10809         -
# 2  Extended offline    Completed without error       00%      9888         -
# 3  Short offline       Completed without error       00%      9728         -
# 4  Extended offline    Completed without error       00%      9387         -
# 5  Extended offline    Completed without error       00%      7235         -
# 6  Short offline       Completed without error       00%      7205         -
# 7  Extended offline    Completed without error       00%      7199         -
# 8  Extended offline    Completed without error       00%      7048         -
# 9  Extended offline    Completed without error       00%      6923         -
#10  Extended offline    Completed: read failure       10%      6920         943937824
#11  Extended offline    Completed: read failure       10%      6918         943937824
#12  Extended offline    Completed: read failure       60%      6917         518569069
#13  Extended offline    Completed: read failure       60%      6914         494499612
#14  Extended offline    Interrupted (host reset)      90%      6914         -
#15  Extended offline    Completed: read failure       60%      6913         487723840
#16  Extended offline    Completed: read failure       70%      6906         397701938
#17  Extended offline    Completed: read failure       70%      6904         397701938
#18  Extended offline    Completed: read failure       70%      6904         361277612
#19  Extended offline    Completed: read failure       70%      6903         360922791
9 of 9 failed self-tests are outdated by newer successful extended offline self-test # 1

SMART Selective self-test log data structure revision number 1
 SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
    1        0        0  Not_testing
    2        0        0  Not_testing
    3        0        0  Not_testing
    4        0        0  Not_testing
    5        0        0  Not_testing
Selective self-test flags (0x0):
  After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

SCT Status Version:                  3
SCT Version (vendor specific):       522 (0x020a)
Device State:                        Active (0)
Current Temperature:                    33 Celsius
Power Cycle Min/Max Temperature:     28/38 Celsius
Lifetime    Min/Max Temperature:     21/48 Celsius
Under/Over Temperature Limit Count:   0/0

SCT Temperature History Version:     2
Temperature Sampling Period:         1 minute
Temperature Logging Interval:        59 minutes
Min/Max recommended Temperature:     14/55 Celsius
Min/Max Temperature Limit:           10/60 Celsius
Temperature History Size (Index):    128 (77)

SCT Error Recovery Control:
           Read: Disabled
          Write: Disabled

Device Statistics (GP/SMART Log 0x04) not supported

Pending Defects log (GP Log 0x0c) not supported

SATA Phy Event Counters (GP Log 0x11)
ID      Size     Value  Description
0x000a  2            3  Device-to-host register FISes sent due to a COMRESET
0x0001  2            0  Command failed due to ICRC error
0x0003  2            0  R_ERR response for device-to-host data FIS
0x0004  2            0  R_ERR response for host-to-device data FIS
0x0006  2            0  R_ERR response for device-to-host non-data FIS
0x0007  2            0  R_ERR response for host-to-device non-data FIS