1
0
mirror of https://github.com/bsdhw/SMART.git synced 2025-05-31 16:21:41 +05:30

Update of reports (new: 3633, modified: 0)

This commit is contained in:
Andrey Ponomarenko
2023-02-14 01:25:13 +03:00
parent 7232be27ad
commit 06d1e49c98
3633 changed files with 600014 additions and 0 deletions

View File

@@ -0,0 +1,103 @@
smartctl 7.3 2022-02-28 r5338 [OpenBSD 7.1 amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: SAMSUNG SpinPoint F1 DT
Device Model: SAMSUNG HD753LJ
Serial Number: --
LU WWN Device Id: 5 0024e9 ...
Firmware Version: 1AA01117
User Capacity: 750,156,374,016 bytes [750 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database 7.3/5319
ATA Version is: ATA/ATAPI-7, ATA8-ACS T13/1699-D revision 3b
Local Time is: Mon Jun 20 13:08:12 2022 EEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART Status not supported: Incomplete response, ATA output registers missing
SMART overall-health self-assessment test result: PASSED
Warning: This result is based on an Attribute check.
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 9485) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 159) minutes.
Conveyance self-test routine
recommended polling time: ( 17) minutes.
SCT capabilities: (0x003f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000f 099 083 051 Pre-fail Always - 41
3 Spin_Up_Time 0x0007 079 079 011 Pre-fail Always - 7150
4 Start_Stop_Count 0x0032 085 085 000 Old_age Always - 14828
5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0
7 Seek_Error_Rate 0x000f 100 100 051 Pre-fail Always - 0
8 Seek_Time_Performance 0x0025 100 100 015 Pre-fail Offline - 0
9 Power_On_Hours 0x0032 092 092 000 Old_age Always - 37947
10 Spin_Retry_Count 0x0033 100 100 051 Pre-fail Always - 1
11 Calibration_Retry_Count 0x0012 100 100 000 Old_age Always - 0
12 Power_Cycle_Count 0x0032 094 094 000 Old_age Always - 5734
13 Read_Soft_Error_Rate 0x000e 099 083 000 Old_age Always - 41
183 Runtime_Bad_Block 0x0032 100 100 000 Old_age Always - 0
184 End-to-End_Error 0x0033 001 001 000 Pre-fail Always - 538
187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 8721
188 Command_Timeout 0x0032 100 100 000 Old_age Always - 0
190 Airflow_Temperature_Cel 0x0022 075 045 000 Old_age Always - 25 (Min/Max 18/25)
194 Temperature_Celsius 0x0022 067 043 000 Old_age Always - 33 (0 47 33 18 0)
195 Hardware_ECC_Recovered 0x001a 100 100 000 Old_age Always - 548044
196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 0
197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 1
198 Offline_Uncorrectable 0x0030 100 100 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x003e 100 099 000 Old_age Always - 36574
200 Multi_Zone_Error_Rate 0x000a 100 099 000 Old_age Always - 0
201 Soft_Read_Error_Rate 0x000a 253 253 000 Old_age Always - 0
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.