1
0
mirror of https://github.com/bsdhw/SMART.git synced 2025-05-31 16:21:41 +05:30

Update of reports (new: 3633, modified: 0)

This commit is contained in:
Andrey Ponomarenko
2023-02-14 01:25:13 +03:00
parent 7232be27ad
commit 06d1e49c98
3633 changed files with 600014 additions and 0 deletions

View File

@@ -0,0 +1,190 @@
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p1 amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Seagate Barracuda 7200.10
Device Model: ST380815AS
Serial Number: --
Firmware Version: 4.ADA
User Capacity: 80,000,000,000 bytes [80.0 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database 7.3/5319
ATA Version is: ATA/ATAPI-7 (minor revision not indicated)
Local Time is: Mon Aug 29 00:21:19 2022 EEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Disabled
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
See vendor-specific Attribute list for marginal Attributes.
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 430) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 27) minutes.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 100 253 006 - 0
3 Spin_Up_Time PO---- 097 097 070 - 0
4 Start_Stop_Count -O--CK 098 098 020 - 2768
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
7 Seek_Error_Rate POSR-- 086 060 030 - 412584252
9 Power_On_Hours -O--CK 063 063 000 - 32426
10 Spin_Retry_Count PO--C- 100 100 097 - 0
12 Power_Cycle_Count -O--CK 098 098 020 - 2767
187 Reported_Uncorrect -O--CK 098 098 000 - 2
189 High_Fly_Writes -O-RCK 100 100 000 - 0
190 Airflow_Temperature_Cel -O---K 057 045 045 Past 43 (Min/Max 28/43)
194 Temperature_Celsius -O---K 043 055 000 - 43 (0 11 0 0 0)
195 Hardware_ECC_Recovered -O-RC- 118 053 000 - 2299073
197 Current_Pending_Sector -O--C- 100 100 000 - 0
198 Offline_Uncorrectable ----C- 100 100 000 - 0
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
200 Multi_Zone_Error_Rate ------ 100 253 000 - 0
202 Data_Address_Mark_Errs -O--CK 100 253 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 GPL,SL R/O 1 Summary SMART error log
0x02 GPL,SL R/O 5 Comprehensive SMART error log
0x03 GPL,SL R/O 5 Ext. Comprehensive SMART error log
0x06 GPL,SL R/O 1 SMART self-test log
0x07 GPL,SL R/O 1 Extended self-test log
0x09 GPL,SL R/W 1 Selective self-test log
0x10 GPL,SL R/O 1 NCQ Command Error log
0x11 GPL,SL R/O 1 SATA Phy Event Counters log
0x20 GPL,SL R/O 1 Streaming performance log [OBS-8]
0x21 GPL,SL R/O 1 Write stream error log
0x22 GPL,SL R/O 1 Read stream error log
0x23 GPL,SL R/O 1 Delayed sector log [OBS-8]
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0 GPL,SL VS 1 Device vendor specific log
0xa1 GPL,SL VS 20 Device vendor specific log
0xa2 GPL,SL VS 101 Device vendor specific log
0xa8 GPL,SL VS 20 Device vendor specific log
0xa9 GPL,SL VS 1 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
0xff GPL - 23040 Reserved
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
Device Error Count: 2
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 2 [1] occurred at disk power-on lifetime: 22741 hours (947 days + 13 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 ac 00 05 a8 e0 00 Error: UNC at LBA = 0xac0005a8 = 2885682600
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 d8 00 08 00 00 ac 00 05 a6 e0 00 00:00:11.627 READ DMA
c8 00 d8 00 08 00 00 ac 00 05 a6 e0 00 00:00:11.627 READ DMA
c8 00 d8 00 08 00 00 ac 00 05 9e e0 00 00:00:11.627 READ DMA
c8 00 d8 00 08 00 00 ac 00 05 96 e0 00 00:00:11.627 READ DMA
c8 00 d8 00 08 00 00 ac 00 05 8e e0 00 00:00:11.627 READ DMA
Error 1 [0] occurred at disk power-on lifetime: 22741 hours (947 days + 13 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 00 ac 00 05 a8 e0 00 Error: UNC at LBA = 0xac0005a8 = 2885682600
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 d8 00 08 00 00 ac 00 05 a6 e0 00 00:00:11.627 READ DMA
c8 00 d8 00 08 00 00 ac 00 05 9e e0 00 00:00:11.627 READ DMA
c8 00 d8 00 08 00 00 ac 00 05 96 e0 00 00:00:11.627 READ DMA
c8 00 d8 00 08 00 00 ac 00 05 8e e0 00 00:00:11.627 READ DMA
c8 00 d8 00 08 00 00 ac 00 05 86 e0 00 00:00:11.627 READ DMA
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 0 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Commands not supported
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x000a 2 8 Device-to-host register FISes sent due to a COMRESET
0x0001 2 0 Command failed due to ICRC error
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS

View File

@@ -0,0 +1,203 @@
smartctl 7.3 2022-02-28 r5338 [OpenBSD 7.1 amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Seagate Barracuda 7200.10
Device Model: ST380815AS
Serial Number: --
Firmware Version: 3.CHF
User Capacity: 80,026,361,856 bytes [80.0 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database 7.3/5319
ATA Version is: ATA/ATAPI-7 (minor revision not indicated)
Local Time is: Sat Jul 2 19:40:15 2022 EET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART Status not supported: Incomplete response, ATA output registers missing
SMART overall-health self-assessment test result: PASSED
Warning: This result is based on an Attribute check.
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 25) The self-test routine was aborted by
the host.
Total time to complete Offline
data collection: ( 433) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 26) minutes.
SCT capabilities: (0x0035) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000f 100 253 006 Pre-fail Always - 0
3 Spin_Up_Time 0x0002 098 097 000 Old_age Always - 0
4 Start_Stop_Count 0x0033 092 092 020 Pre-fail Always - 8860
5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 0
7 Seek_Error_Rate 0x000f 086 060 030 Pre-fail Always - 415255442
9 Power_On_Hours 0x0032 042 042 000 Old_age Always - 51653
10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 0
12 Power_Cycle_Count 0x0033 092 092 020 Pre-fail Always - 8732
184 End-to-End_Error 0x0033 100 253 097 Pre-fail Always - 0
187 Reported_Uncorrect 0x003a 001 001 000 Old_age Always - 102
189 High_Fly_Writes 0x0022 100 100 000 Old_age Always - 0
190 Airflow_Temperature_Cel 0x001a 057 050 000 Old_age Always - 43 (Min/Max 41/44)
194 Temperature_Celsius 0x0000 043 050 000 Old_age Offline - 43 (0 12 0 0 0)
195 Hardware_ECC_Recovered 0x0032 065 048 000 Old_age Always - 182402800
197 Current_Pending_Sector 0x0000 001 001 000 Old_age Offline - 4294967280
198 Offline_Uncorrectable 0x0000 100 100 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x0000 200 200 000 Old_age Offline - 397
SMART Error Log Version: 1
ATA Error Count: 637 (device log contains only the most recent five errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 637 occurred at disk power-on lifetime: 49618 hours (2067 days + 10 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 56 12 08 00 e0 Error: ICRC, ABRT 86 sectors at LBA = 0x00000812 = 2066
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 67 01 08 00 e0 00 00:00:13.795 READ DMA
c8 00 67 01 08 00 e0 00 00:00:13.283 READ DMA
c8 00 67 01 08 00 e0 00 00:00:12.771 READ DMA
c8 00 01 00 08 00 e0 00 00:00:12.769 READ DMA
c8 00 01 00 00 00 e0 00 00:00:12.722 READ DMA
Error 636 occurred at disk power-on lifetime: 49618 hours (2067 days + 10 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 56 12 08 00 e0 Error: ICRC, ABRT 86 sectors at LBA = 0x00000812 = 2066
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 67 01 08 00 e0 00 00:00:04.391 READ DMA
c8 00 67 01 08 00 e0 00 00:00:13.283 READ DMA
c8 00 01 00 08 00 e0 00 00:00:12.771 READ DMA
c8 00 01 00 00 00 e0 00 00:00:12.769 READ DMA
c8 00 01 01 00 00 e0 00 00:00:12.722 READ DMA
Error 635 occurred at disk power-on lifetime: 49618 hours (2067 days + 10 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 56 12 08 00 e0 Error: ICRC, ABRT 86 sectors at LBA = 0x00000812 = 2066
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 67 01 08 00 e0 00 00:00:04.391 READ DMA
c8 00 01 00 08 00 e0 00 00:00:04.391 READ DMA
c8 00 01 00 00 00 e0 00 00:00:12.771 READ DMA
c8 00 01 01 00 00 e0 00 00:00:12.769 READ DMA
c8 00 01 00 00 00 e0 00 00:00:12.722 READ DMA
Error 634 occurred at disk power-on lifetime: 49618 hours (2067 days + 10 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 56 12 08 00 e0 Error: ICRC, ABRT 86 sectors at LBA = 0x00000812 = 2066
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 67 01 08 00 e0 00 00:00:13.791 READ DMA
c8 00 67 01 08 00 e0 00 00:00:13.270 READ DMA
c8 00 67 01 08 00 e0 00 00:00:12.749 READ DMA
c8 00 01 00 08 00 e0 00 00:00:12.744 READ DMA
c8 00 01 00 00 00 e0 00 00:00:12.707 READ DMA
Error 633 occurred at disk power-on lifetime: 49618 hours (2067 days + 10 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 56 12 08 00 e0 Error: ICRC, ABRT 86 sectors at LBA = 0x00000812 = 2066
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 67 01 08 00 e0 00 00:00:04.351 READ DMA
c8 00 67 01 08 00 e0 00 00:00:13.270 READ DMA
c8 00 01 00 08 00 e0 00 00:00:12.749 READ DMA
c8 00 01 00 00 00 e0 00 00:00:12.744 READ DMA
c8 00 01 01 00 00 e0 00 00:00:12.707 READ DMA
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Aborted by host 90% 51521 -
# 2 Short captive Interrupted (host reset) 90% 51521 -
# 3 Short captive Interrupted (host reset) 90% 51521 -
# 4 Short offline Completed without error 00% 51384 -
# 5 Short offline Completed without error 00% 50715 -
# 6 Short offline Completed without error 00% 50643 -
# 7 Short offline Aborted by host 90% 39936 -
# 8 Short offline Completed without error 00% 39936 -
# 9 Short offline Aborted by host 70% 39925 -
#10 Extended offline Interrupted (host reset) 50% 24820 -
#11 Short offline Aborted by host 40% 24820 -
#12 Short captive Completed without error 00% 14568 -
#13 Extended offline Interrupted (host reset) 30% 1 -
#14 Short offline Aborted by host 90% 51521 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.