171
HDD/Toshiba/MK2561/MK2561GSYB/B7753E7A47F7
Normal file
171
HDD/Toshiba/MK2561/MK2561GSYB/B7753E7A47F7
Normal file
@@ -0,0 +1,171 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p3 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Toshiba 2.5" HDD MK..61GSYB
|
||||
Device Model: TOSHIBA MK2561GSYB
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000039 ...
|
||||
Firmware Version: ME0A
|
||||
User Capacity: 250,059,350,016 bytes [250 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Thu Nov 10 05:21:29 2022 UTC
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 120) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 67) minutes.
|
||||
SCT capabilities: (0x003d) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate PO-R-- 100 100 050 - 0
|
||||
2 Throughput_Performance P-S--- 100 100 050 - 0
|
||||
3 Spin_Up_Time POS--K 100 100 001 - 1372
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 80
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 050 - 0
|
||||
7 Seek_Error_Rate PO-R-- 100 100 050 - 0
|
||||
8 Seek_Time_Performance P-S--- 100 100 050 - 0
|
||||
9 Power_On_Hours -O--CK 022 022 000 - 31344
|
||||
10 Spin_Retry_Count PO--CK 101 100 030 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 80
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 2
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 63
|
||||
193 Load_Cycle_Count -O--CK 100 100 000 - 146
|
||||
194 Temperature_Celsius -O---K 100 100 000 - 33 (Min/Max 16/51)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
|
||||
220 Disk_Shift -O---- 100 100 000 - 142
|
||||
222 Loaded_Hours -O--CK 006 006 000 - 37603
|
||||
223 Load_Retry_Count -O--CK 100 100 000 - 0
|
||||
224 Load_Friction -O---K 100 100 000 - 0
|
||||
226 Load-in_Time -OS--K 100 100 000 - 255
|
||||
240 Head_Flying_Hours P----- 100 100 001 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 51 Comprehensive SMART error log
|
||||
0x03 GPL R/O 64 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (64 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 34 Celsius
|
||||
Power Cycle Min/Max Temperature: 31/34 Celsius
|
||||
Lifetime Min/Max Temperature: 16/51 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 5/55 Celsius
|
||||
Min/Max Temperature Limit: 5/55 Celsius
|
||||
Temperature History Size (Index): 478 (68)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x0002 4 0 R_ERR response for data FIS
|
||||
0x0003 4 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 4 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 4 0 R_ERR response for non-data FIS
|
||||
0x0006 4 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 4 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 4 0 Device-to-host non-data FIS retries
|
||||
0x0009 4 9 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 4 9 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 4 0 CRC errors within host-to-device FIS
|
||||
0x000d 4 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 4 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0010 4 0 R_ERR response for host-to-device data FIS, non-CRC
|
||||
0x0012 4 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x0013 4 0 R_ERR response for host-to-device non-data FIS, non-CRC
|
||||
|
173
HDD/Toshiba/MK2561/MK2561GSYB/BDB163993FEB
Normal file
173
HDD/Toshiba/MK2561/MK2561GSYB/BDB163993FEB
Normal file
@@ -0,0 +1,173 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p3 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Toshiba 2.5" HDD MK..61GSYB
|
||||
Device Model: TOSHIBA MK2561GSYB
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000039 ...
|
||||
Firmware Version: ME0A
|
||||
User Capacity: 250,059,350,016 bytes [250 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Thu Nov 10 05:21:28 2022 UTC
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 120) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 65) minutes.
|
||||
SCT capabilities: (0x003d) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate PO-R-- 100 100 050 - 0
|
||||
2 Throughput_Performance P-S--- 100 100 050 - 0
|
||||
3 Spin_Up_Time POS--K 100 100 001 - 1369
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 80
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 050 - 0
|
||||
7 Seek_Error_Rate PO-R-- 100 100 050 - 0
|
||||
8 Seek_Time_Performance P-S--- 100 100 050 - 0
|
||||
9 Power_On_Hours -O--CK 022 022 000 - 31344
|
||||
10 Spin_Retry_Count PO--CK 101 100 030 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 80
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 3
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 62
|
||||
193 Load_Cycle_Count -O--CK 100 100 000 - 148
|
||||
194 Temperature_Celsius -O---K 100 100 000 - 33 (Min/Max 16/50)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
|
||||
220 Disk_Shift -O---- 100 100 000 - 144
|
||||
222 Loaded_Hours -O--CK 021 021 000 - 31638
|
||||
223 Load_Retry_Count -O--CK 100 100 000 - 0
|
||||
224 Load_Friction -O---K 100 100 000 - 0
|
||||
226 Load-in_Time -OS--K 100 100 000 - 259
|
||||
240 Head_Flying_Hours P----- 100 100 001 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 51 Comprehensive SMART error log
|
||||
0x03 GPL R/O 64 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (64 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 33 Celsius
|
||||
Power Cycle Min/Max Temperature: 31/34 Celsius
|
||||
Lifetime Min/Max Temperature: 16/50 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 5/55 Celsius
|
||||
Min/Max Temperature Limit: 5/55 Celsius
|
||||
Temperature History Size (Index): 478 (339)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x0002 4 0 R_ERR response for data FIS
|
||||
0x0003 4 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 4 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 4 0 R_ERR response for non-data FIS
|
||||
0x0006 4 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 4 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 4 0 Device-to-host non-data FIS retries
|
||||
0x0009 4 9 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 4 9 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 4 0 CRC errors within host-to-device FIS
|
||||
0x000d 4 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 4 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0010 4 0 R_ERR response for host-to-device data FIS, non-CRC
|
||||
0x0012 4 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x0013 4 0 R_ERR response for host-to-device non-data FIS, non-CRC
|
||||
|
||||
|
||||
|
321
HDD/Toshiba/MK2561/MK2561GSYN/432D341D4096
Normal file
321
HDD/Toshiba/MK2561/MK2561GSYN/432D341D4096
Normal file
@@ -0,0 +1,321 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Toshiba 2.5" HDD MK..61GSY[N]
|
||||
Device Model: TOSHIBA MK2561GSYN
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000039 ...
|
||||
Firmware Version: MH000A
|
||||
User Capacity: 250,059,350,016 bytes [250 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Sun May 22 05:17:01 2022 EDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 120) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 60) minutes.
|
||||
SCT capabilities: (0x003d) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate PO-R-- 100 100 050 - 0
|
||||
2 Throughput_Performance P-S--- 100 100 050 - 0
|
||||
3 Spin_Up_Time POS--K 100 100 001 - 1250
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 2004
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 050 - 0
|
||||
7 Seek_Error_Rate PO-R-- 100 100 050 - 0
|
||||
8 Seek_Time_Performance P-S--- 100 100 050 - 0
|
||||
9 Power_On_Minutes -O--CK 043 043 000 - 381h+09m
|
||||
10 Spin_Retry_Count PO--CK 140 100 030 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 1883
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 180
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 94
|
||||
193 Load_Cycle_Count -O--CK 096 096 000 - 46298
|
||||
194 Temperature_Celsius -O---K 100 100 000 - 39 (Min/Max 16/49)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 802
|
||||
220 Disk_Shift -O---- 100 100 000 - 78
|
||||
222 Loaded_Hours -O--CK 045 045 000 - 22320
|
||||
223 Load_Retry_Count -O--CK 100 100 000 - 0
|
||||
224 Load_Friction -O---K 100 100 000 - 0
|
||||
226 Load-in_Time -OS--K 100 100 000 - 359
|
||||
240 Head_Flying_Hours P----- 100 100 001 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 51 Comprehensive SMART error log
|
||||
0x03 GPL R/O 64 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (64 sectors)
|
||||
Device Error Count: 211
|
||||
CR = Command Register
|
||||
FEATR = Features Register
|
||||
COUNT = Count (was: Sector Count) Register
|
||||
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
|
||||
LH = LBA High (was: Cylinder High) Register ] LBA
|
||||
LM = LBA Mid (was: Cylinder Low) Register ] Register
|
||||
LL = LBA Low (was: Sector Number) Register ]
|
||||
DV = Device (was: Device/Head) Register
|
||||
DC = Device Control Register
|
||||
ER = Error register
|
||||
ST = Status register
|
||||
Powered_Up_Time is measured from power on, and printed as
|
||||
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
||||
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
||||
|
||||
Error 211 [210] occurred at disk power-on lifetime: 22827 hours (951 days + 3 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
84 -- 51 00 01 00 00 11 66 98 0b 40 00 Error: ABRT at LBA = 0x1166980b = 291936267
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
24 00 00 00 02 00 00 11 66 98 0a 40 00 00:00:06.050 READ SECTOR(S) EXT
|
||||
24 00 00 00 02 00 00 11 66 98 00 40 00 00:00:06.047 READ SECTOR(S) EXT
|
||||
24 00 00 00 08 00 00 11 06 99 60 40 00 00:00:06.022 READ SECTOR(S) EXT
|
||||
24 00 00 00 02 00 00 11 66 98 0a 40 00 00:00:06.019 READ SECTOR(S) EXT
|
||||
24 00 00 00 02 00 00 11 66 98 00 40 00 00:00:06.010 READ SECTOR(S) EXT
|
||||
|
||||
Error 210 [209] occurred at disk power-on lifetime: 22827 hours (951 days + 3 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
84 -- 51 00 07 60 08 0b 00 09 21 40 00 Error: ABRT at LBA = 0x60080b000921 = 105587660556577
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
20 00 00 00 08 60 08 0b 00 09 20 40 00 00:00:05.822 READ SECTOR(S)
|
||||
20 00 00 00 02 60 08 01 60 08 0a 40 00 00:00:05.820 READ SECTOR(S)
|
||||
20 00 00 01 02 60 08 0b 60 08 00 40 00 00:00:05.809 READ SECTOR(S)
|
||||
20 00 00 00 02 60 08 01 60 08 0a 40 00 00:00:05.653 READ SECTOR(S)
|
||||
20 00 00 00 02 00 08 00 60 08 00 40 00 00:00:05.631 READ SECTOR(S)
|
||||
|
||||
Error 209 [208] occurred at disk power-on lifetime: 22827 hours (951 days + 3 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
84 -- 51 00 01 60 08 01 60 08 0b 40 00 Error: ABRT at LBA = 0x60080160080b = 105587499075595
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
20 00 00 00 02 60 08 01 60 08 0a 40 00 00:00:05.653 READ SECTOR(S)
|
||||
20 00 00 00 02 00 08 00 60 08 00 40 00 00:00:05.631 READ SECTOR(S)
|
||||
20 00 00 00 01 00 08 00 00 08 00 40 00 00:00:05.630 READ SECTOR(S)
|
||||
20 00 00 00 01 00 08 00 00 08 00 40 00 00:00:05.629 READ SECTOR(S)
|
||||
20 00 00 00 01 06 98 00 00 08 00 40 00 00:00:05.627 READ SECTOR(S)
|
||||
|
||||
Error 208 [207] occurred at disk power-on lifetime: 22825 hours (951 days + 1 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
84 -- 51 00 04 60 08 0b 00 09 24 40 00 Error: ABRT at LBA = 0x60080b000924 = 105587660556580
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
20 00 00 00 08 60 08 0b 00 09 20 40 00 00:21:41.089 READ SECTOR(S)
|
||||
20 00 00 00 02 60 08 01 60 08 0a 40 00 00:21:41.086 READ SECTOR(S)
|
||||
20 00 00 07 02 00 09 21 60 08 00 40 00 00:21:41.076 READ SECTOR(S)
|
||||
20 00 00 00 08 60 08 0b 00 09 20 40 00 00:21:40.906 READ SECTOR(S)
|
||||
20 00 00 00 02 60 08 01 60 08 0a 40 00 00:21:40.903 READ SECTOR(S)
|
||||
|
||||
Error 207 [206] occurred at disk power-on lifetime: 22825 hours (951 days + 1 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
84 -- 51 00 07 60 08 0b 00 09 21 40 00 Error: ABRT at LBA = 0x60080b000921 = 105587660556577
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
20 00 00 00 08 60 08 0b 00 09 20 40 00 00:21:40.906 READ SECTOR(S)
|
||||
20 00 00 00 02 60 08 01 60 08 0a 40 00 00:21:40.903 READ SECTOR(S)
|
||||
20 00 00 00 02 00 08 00 60 08 00 40 00 00:21:40.879 READ SECTOR(S)
|
||||
20 00 00 00 01 00 08 00 00 08 00 40 00 00:21:40.877 READ SECTOR(S)
|
||||
20 00 00 00 01 00 08 00 00 08 00 40 00 00:21:40.876 READ SECTOR(S)
|
||||
|
||||
Error 206 [205] occurred at disk power-on lifetime: 22825 hours (951 days + 1 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
84 -- 51 00 01 00 00 11 66 98 0b 40 00 Error: ABRT at LBA = 0x1166980b = 291936267
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
24 00 00 00 02 00 00 11 66 98 0a 40 00 00:10:41.389 READ SECTOR(S) EXT
|
||||
24 00 00 00 02 00 00 11 66 98 00 40 00 00:10:41.371 READ SECTOR(S) EXT
|
||||
24 00 00 00 02 00 00 22 cc 75 9c 40 00 00:10:41.370 READ SECTOR(S) EXT
|
||||
24 00 00 00 02 00 00 11 66 98 00 40 00 00:10:41.205 READ SECTOR(S) EXT
|
||||
24 00 00 00 01 00 00 11 06 98 00 40 00 00:10:41.187 READ SECTOR(S) EXT
|
||||
|
||||
Error 205 [204] occurred at disk power-on lifetime: 22825 hours (951 days + 1 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
84 -- 51 00 01 00 00 11 66 98 01 40 00 Error: ABRT at LBA = 0x11669801 = 291936257
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
24 00 00 00 02 00 00 11 66 98 00 40 00 00:10:41.205 READ SECTOR(S) EXT
|
||||
24 00 00 00 01 00 00 11 06 98 00 40 00 00:10:41.187 READ SECTOR(S) EXT
|
||||
24 00 00 00 02 00 00 21 f7 a0 3c 40 00 00:10:41.187 READ SECTOR(S) EXT
|
||||
24 00 00 00 02 00 00 10 fc 2d 50 40 00 00:10:41.012 READ SECTOR(S) EXT
|
||||
24 00 00 00 02 00 00 21 f7 a0 3c 40 00 00:10:41.012 READ SECTOR(S) EXT
|
||||
|
||||
Error 204 [203] occurred at disk power-on lifetime: 22825 hours (951 days + 1 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
84 -- 51 00 01 00 00 10 fc 2d 51 40 00 Error: ABRT at LBA = 0x10fc2d51 = 284962129
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
24 00 00 00 02 00 00 10 fc 2d 50 40 00 00:10:41.012 READ SECTOR(S) EXT
|
||||
24 00 00 00 02 00 00 21 f7 a0 3c 40 00 00:10:41.012 READ SECTOR(S) EXT
|
||||
24 00 00 00 02 00 00 10 fc 2d 50 40 00 00:10:40.840 READ SECTOR(S) EXT
|
||||
24 00 00 00 01 00 00 10 f6 f8 00 40 00 00:10:40.838 READ SECTOR(S) EXT
|
||||
24 00 00 00 01 00 00 10 f6 f8 00 40 00 00:10:40.837 READ SECTOR(S) EXT
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 39 Celsius
|
||||
Power Cycle Min/Max Temperature: 37/39 Celsius
|
||||
Lifetime Min/Max Temperature: 16/49 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 5/55 Celsius
|
||||
Min/Max Temperature Limit: 5/55 Celsius
|
||||
Temperature History Size (Index): 478 (458)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x0002 4 1 R_ERR response for data FIS
|
||||
0x0003 4 1 R_ERR response for device-to-host data FIS
|
||||
0x0004 4 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 4 0 R_ERR response for non-data FIS
|
||||
0x0006 4 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 4 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 4 0 Device-to-host non-data FIS retries
|
||||
0x0009 4 1 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 4 0 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 4 0 CRC errors within host-to-device FIS
|
||||
0x000d 4 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 4 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0010 4 0 R_ERR response for host-to-device data FIS, non-CRC
|
||||
0x0012 4 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x0013 4 0 R_ERR response for host-to-device non-data FIS, non-CRC
|
||||
|
Reference in New Issue
Block a user