mirror of
https://github.com/bsdhw/SMART.git
synced 2025-05-31 16:21:41 +05:30
Update of reports (new: 3633, modified: 0)
This commit is contained in:
97
HDD/WDC/WD6400/WD6400AAKS-22A7B0/A35677242C5E
Normal file
97
HDD/WDC/WD6400/WD6400AAKS-22A7B0/A35677242C5E
Normal file
@@ -0,0 +1,97 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [OpenBSD 7.1 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Western Digital Caviar Blue (SATA)
|
||||
Device Model: WDC WD6400AAKS-22A7B0
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 0014ee ...
|
||||
Firmware Version: 01.03B01
|
||||
User Capacity: 640,135,028,736 bytes [640 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 2.5, 3.0 Gb/s
|
||||
Local Time is: Sat Sep 24 19:27:33 2022 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART Status not supported: Incomplete response, ATA output registers missing
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
Warning: This result is based on an Attribute check.
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x84) Offline data collection activity
|
||||
was suspended by an interrupting command from host.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: (11160) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 131) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 5) minutes.
|
||||
SCT capabilities: (0x303f) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
|
||||
1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always - 0
|
||||
3 Spin_Up_Time 0x0027 155 152 021 Pre-fail Always - 5225
|
||||
4 Start_Stop_Count 0x0032 097 097 000 Old_age Always - 3954
|
||||
5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0
|
||||
7 Seek_Error_Rate 0x002e 200 200 051 Old_age Always - 0
|
||||
9 Power_On_Hours 0x0032 076 076 000 Old_age Always - 18045
|
||||
10 Spin_Retry_Count 0x0032 100 100 051 Old_age Always - 0
|
||||
11 Calibration_Retry_Count 0x0032 100 100 051 Old_age Always - 0
|
||||
12 Power_Cycle_Count 0x0032 097 097 000 Old_age Always - 3900
|
||||
192 Power-Off_Retract_Count 0x0032 198 198 000 Old_age Always - 1820
|
||||
193 Load_Cycle_Count 0x0032 199 199 000 Old_age Always - 3954
|
||||
194 Temperature_Celsius 0x0022 104 093 000 Old_age Always - 43
|
||||
196 Reallocated_Event_Count 0x0032 197 197 000 Old_age Always - 3
|
||||
197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 0
|
||||
198 Offline_Uncorrectable 0x0030 200 200 000 Old_age Offline - 3
|
||||
199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0
|
||||
200 Multi_Zone_Error_Rate 0x0008 200 200 051 Old_age Offline - 0
|
||||
|
||||
SMART Error Log Version: 1
|
||||
No Errors Logged
|
||||
|
||||
SMART Self-test log structure revision number 1
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
|
||||
|
311
HDD/WDC/WD6400/WD6400AAKS-22A7B2/0EADAAFF058A
Normal file
311
HDD/WDC/WD6400/WD6400AAKS-22A7B2/0EADAAFF058A
Normal file
@@ -0,0 +1,311 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Western Digital Caviar Blue (SATA)
|
||||
Device Model: WDC WD6400AAKS-22A7B2
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 0014ee ...
|
||||
Firmware Version: 01.03B01
|
||||
User Capacity: 640,135,028,736 bytes [640 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 2.5, 3.0 Gb/s
|
||||
Local Time is: Mon Dec 19 02:54:48 2022 CST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x84) Offline data collection activity
|
||||
was suspended by an interrupting command from host.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: (12000) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 140) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 5) minutes.
|
||||
SCT capabilities: (0x3037) SCT Status supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 42
|
||||
3 Spin_Up_Time POS--K 161 158 021 - 4916
|
||||
4 Start_Stop_Count -O--CK 094 094 000 - 6336
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 100 253 000 - 0
|
||||
9 Power_On_Hours -O--CK 053 053 000 - 34342
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 094 094 000 - 6302
|
||||
192 Power-Off_Retract_Count -O--CK 198 198 000 - 2157
|
||||
193 Load_Cycle_Count -O--CK 198 198 000 - 6335
|
||||
194 Temperature_Celsius -O---K 109 090 000 - 38
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 14
|
||||
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 2
|
||||
200 Multi_Zone_Error_Rate ---R-- 200 200 000 - 7
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 6 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
|
||||
0xa8-0xb7 GPL,SL VS 1 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xc1 GPL VS 24 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
|
||||
Device Error Count: 197 (device log contains only the most recent 24 errors)
|
||||
CR = Command Register
|
||||
FEATR = Features Register
|
||||
COUNT = Count (was: Sector Count) Register
|
||||
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
|
||||
LH = LBA High (was: Cylinder High) Register ] LBA
|
||||
LM = LBA Mid (was: Cylinder Low) Register ] Register
|
||||
LL = LBA Low (was: Sector Number) Register ]
|
||||
DV = Device (was: Device/Head) Register
|
||||
DC = Device Control Register
|
||||
ER = Error register
|
||||
ST = Status register
|
||||
Powered_Up_Time is measured from power on, and printed as
|
||||
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
||||
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
||||
|
||||
Error 197 [4] occurred at disk power-on lifetime: 34320 hours (1430 days + 0 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 00 00 0a 77 00 fb 75 40 00 Error: UNC at LBA = 0xa7700fb75 = 44946226037
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 08 00 d8 00 00 0a fb 77 70 40 08 01:17:43.423 READ FPDMA QUEUED
|
||||
ef 00 10 00 02 00 00 00 00 00 00 a0 08 01:17:43.423 SET FEATURES [Enable SATA feature]
|
||||
27 00 00 00 00 00 00 00 00 00 00 e0 08 01:17:43.422 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
|
||||
ec 00 00 00 00 00 00 00 00 00 00 a0 08 01:17:43.422 IDENTIFY DEVICE
|
||||
ef 00 03 00 46 00 00 00 00 00 00 a0 08 01:17:43.422 SET FEATURES [Set transfer mode]
|
||||
|
||||
Error 196 [3] occurred at disk power-on lifetime: 34320 hours (1430 days + 0 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 00 00 0a 77 00 fb 75 40 00 Error: UNC at LBA = 0xa7700fb75 = 44946226037
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 08 00 48 00 00 0a fb 77 70 40 08 01:17:40.944 READ FPDMA QUEUED
|
||||
ef 00 10 00 02 00 00 00 00 00 00 a0 08 01:17:40.944 SET FEATURES [Enable SATA feature]
|
||||
27 00 00 00 00 00 00 00 00 00 00 e0 08 01:17:40.944 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
|
||||
ec 00 00 00 00 00 00 00 00 00 00 a0 08 01:17:40.943 IDENTIFY DEVICE
|
||||
ef 00 03 00 46 00 00 00 00 00 00 a0 08 01:17:40.943 SET FEATURES [Set transfer mode]
|
||||
|
||||
Error 195 [2] occurred at disk power-on lifetime: 34320 hours (1430 days + 0 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 00 00 0a 77 00 fb 75 40 00 Error: UNC at LBA = 0xa7700fb75 = 44946226037
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 08 00 20 00 00 0a fb 77 70 40 08 01:17:38.528 READ FPDMA QUEUED
|
||||
60 00 08 00 18 00 00 0a fb 77 68 40 08 01:17:38.528 READ FPDMA QUEUED
|
||||
60 00 08 00 10 00 00 0a fb 77 60 40 08 01:17:38.528 READ FPDMA QUEUED
|
||||
60 00 08 00 08 00 00 0a fb 77 58 40 08 01:17:38.528 READ FPDMA QUEUED
|
||||
60 00 08 00 00 00 00 0a fb 77 50 40 08 01:17:38.528 READ FPDMA QUEUED
|
||||
|
||||
Error 194 [1] occurred at disk power-on lifetime: 34320 hours (1430 days + 0 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 00 00 0a 88 00 f9 13 40 00 Error: UNC at LBA = 0xa8800f913 = 45231438099
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 08 00 80 00 00 0a f9 88 10 40 08 01:17:33.875 READ FPDMA QUEUED
|
||||
ef 00 10 00 02 00 00 00 00 00 00 a0 08 01:17:33.874 SET FEATURES [Enable SATA feature]
|
||||
27 00 00 00 00 00 00 00 00 00 00 e0 08 01:17:33.874 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
|
||||
ec 00 00 00 00 00 00 00 00 00 00 a0 08 01:17:33.873 IDENTIFY DEVICE
|
||||
ef 00 03 00 46 00 00 00 00 00 00 a0 08 01:17:33.873 SET FEATURES [Set transfer mode]
|
||||
|
||||
Error 193 [0] occurred at disk power-on lifetime: 34320 hours (1430 days + 0 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 00 00 0a 88 00 f9 13 40 00 Error: UNC at LBA = 0xa8800f913 = 45231438099
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 08 00 e8 00 00 0a f9 88 10 40 08 01:17:31.378 READ FPDMA QUEUED
|
||||
ef 00 10 00 02 00 00 00 00 00 00 a0 08 01:17:31.378 SET FEATURES [Enable SATA feature]
|
||||
27 00 00 00 00 00 00 00 00 00 00 e0 08 01:17:31.377 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
|
||||
ec 00 00 00 00 00 00 00 00 00 00 a0 08 01:17:31.377 IDENTIFY DEVICE
|
||||
ef 00 03 00 46 00 00 00 00 00 00 a0 08 01:17:31.377 SET FEATURES [Set transfer mode]
|
||||
|
||||
Error 192 [23] occurred at disk power-on lifetime: 34320 hours (1430 days + 0 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 00 00 0a 88 00 f9 13 40 00 Error: UNC at LBA = 0xa8800f913 = 45231438099
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 08 00 e0 00 00 0a f9 88 10 40 08 01:17:28.825 READ FPDMA QUEUED
|
||||
60 00 08 00 d8 00 00 0a f9 88 08 40 08 01:17:28.825 READ FPDMA QUEUED
|
||||
60 00 08 00 d0 00 00 0a f9 88 00 40 08 01:17:28.825 READ FPDMA QUEUED
|
||||
60 00 08 00 c8 00 00 0a f9 87 f8 40 08 01:17:28.824 READ FPDMA QUEUED
|
||||
60 00 08 00 c0 00 00 0a f9 87 f0 40 08 01:17:28.824 READ FPDMA QUEUED
|
||||
|
||||
Error 191 [22] occurred at disk power-on lifetime: 34320 hours (1430 days + 0 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 00 00 0a 09 00 e8 a5 40 00 Error: UNC at LBA = 0xa0900e8a5 = 43100727461
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 08 00 90 00 00 0a e8 09 a0 40 08 01:17:04.313 READ FPDMA QUEUED
|
||||
ef 00 10 00 02 00 00 00 00 00 00 a0 08 01:17:04.313 SET FEATURES [Enable SATA feature]
|
||||
27 00 00 00 00 00 00 00 00 00 00 e0 08 01:17:04.313 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
|
||||
ec 00 00 00 00 00 00 00 00 00 00 a0 08 01:17:04.312 IDENTIFY DEVICE
|
||||
ef 00 03 00 46 00 00 00 00 00 00 a0 08 01:17:04.312 SET FEATURES [Set transfer mode]
|
||||
|
||||
Error 190 [21] occurred at disk power-on lifetime: 34320 hours (1430 days + 0 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 00 00 0a 09 00 e8 a5 40 00 Error: UNC at LBA = 0xa0900e8a5 = 43100727461
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 08 00 f8 00 00 0a e8 09 a0 40 08 01:17:01.667 READ FPDMA QUEUED
|
||||
ef 00 10 00 02 00 00 00 00 00 00 a0 08 01:17:01.667 SET FEATURES [Enable SATA feature]
|
||||
27 00 00 00 00 00 00 00 00 00 00 e0 08 01:17:01.667 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
|
||||
ec 00 00 00 00 00 00 00 00 00 00 a0 08 01:17:01.666 IDENTIFY DEVICE
|
||||
ef 00 03 00 46 00 00 00 00 00 00 a0 08 01:17:01.666 SET FEATURES [Set transfer mode]
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 26319 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: SMART Off-line Data Collection executing in background (4)
|
||||
Current Temperature: 38 Celsius
|
||||
Power Cycle Min/Max Temperature: 38/39 Celsius
|
||||
Lifetime Min/Max Temperature: 18/57 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 128 (116)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
|
||||
0x8000 4 638 Vendor specific
|
||||
|
||||
|
||||
|
308
HDD/WDC/WD6400/WD6400AAKS-22A7B2/E61E692860B8
Normal file
308
HDD/WDC/WD6400/WD6400AAKS-22A7B2/E61E692860B8
Normal file
@@ -0,0 +1,308 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.0-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Western Digital Caviar Blue (SATA)
|
||||
Device Model: WDC WD6400AAKS-22A7B2
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 0014ee ...
|
||||
Firmware Version: 01.03B01
|
||||
User Capacity: 640,135,028,736 bytes [640 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 2.5, 3.0 Gb/s
|
||||
Local Time is: Fri Jun 3 17:48:04 2022 EDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x84) Offline data collection activity
|
||||
was suspended by an interrupting command from host.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: (11160) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 131) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 5) minutes.
|
||||
SCT capabilities: (0x3037) SCT Status supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 4
|
||||
3 Spin_Up_Time POS--K 163 160 021 - 4850
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 641
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 001 001 000 - 95755
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 638
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 161
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 641
|
||||
194 Temperature_Celsius -O---K 109 085 000 - 38
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 23
|
||||
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate ---R-- 200 200 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 6 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
|
||||
0xa8-0xb7 GPL,SL VS 1 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xc1 GPL VS 24 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
|
||||
Device Error Count: 134 (device log contains only the most recent 24 errors)
|
||||
CR = Command Register
|
||||
FEATR = Features Register
|
||||
COUNT = Count (was: Sector Count) Register
|
||||
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
|
||||
LH = LBA High (was: Cylinder High) Register ] LBA
|
||||
LM = LBA Mid (was: Cylinder Low) Register ] Register
|
||||
LL = LBA Low (was: Sector Number) Register ]
|
||||
DV = Device (was: Device/Head) Register
|
||||
DC = Device Control Register
|
||||
ER = Error register
|
||||
ST = Status register
|
||||
Powered_Up_Time is measured from power on, and printed as
|
||||
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
||||
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
||||
|
||||
Error 134 [13] occurred at disk power-on lifetime: 29885 hours (1245 days + 5 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 00 00 12 53 00 a6 17 40 00 Error: UNC at LBA = 0x125300a617 = 78701962775
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 40 00 00 00 00 12 a6 53 80 40 08 17:36:11.487 READ FPDMA QUEUED
|
||||
60 00 40 00 f8 00 00 12 a6 53 00 40 08 17:36:11.487 READ FPDMA QUEUED
|
||||
60 00 38 00 50 00 00 12 c5 05 80 40 08 17:36:11.362 READ FPDMA QUEUED
|
||||
60 00 40 00 d0 00 00 12 c4 f9 80 40 08 17:36:11.356 READ FPDMA QUEUED
|
||||
60 00 40 00 c8 00 00 12 a6 1d 80 40 08 17:36:11.356 READ FPDMA QUEUED
|
||||
|
||||
Error 133 [12] occurred at disk power-on lifetime: 29640 hours (1235 days + 0 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 00 00 12 43 00 a8 fa 40 00 Error: WP at LBA = 0x124300a8fa = 78433528058
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
61 00 08 00 70 00 00 0f 9f 54 c8 40 08 16d+03:45:12.722 WRITE FPDMA QUEUED
|
||||
61 00 10 00 d8 00 00 01 01 80 a0 40 08 16d+03:45:12.721 WRITE FPDMA QUEUED
|
||||
61 00 08 00 60 00 00 0e 81 d6 f0 40 08 16d+03:45:12.721 WRITE FPDMA QUEUED
|
||||
60 00 08 00 68 00 00 12 a8 43 f8 40 08 16d+03:45:12.720 READ FPDMA QUEUED
|
||||
61 00 70 00 40 00 00 12 83 dd 10 40 08 16d+03:45:12.719 WRITE FPDMA QUEUED
|
||||
|
||||
Error 132 [11] occurred at disk power-on lifetime: 29640 hours (1235 days + 0 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 00 00 12 43 00 a8 fa 40 00 Error: UNC at LBA = 0x124300a8fa = 78433528058
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 08 00 28 00 00 12 a8 43 f8 40 08 16d+03:45:10.047 READ FPDMA QUEUED
|
||||
61 00 08 00 c0 00 00 0f 3e dc 48 40 08 16d+03:45:09.770 WRITE FPDMA QUEUED
|
||||
ea 00 00 00 00 00 00 00 00 00 00 e0 08 16d+03:45:09.515 FLUSH CACHE EXT
|
||||
61 00 20 00 80 00 00 09 f1 37 60 40 08 16d+03:45:09.515 WRITE FPDMA QUEUED
|
||||
61 00 20 00 78 00 00 01 00 b5 80 40 08 16d+03:45:09.515 WRITE FPDMA QUEUED
|
||||
|
||||
Error 131 [10] occurred at disk power-on lifetime: 29640 hours (1235 days + 0 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 00 00 12 43 00 a8 fa 40 00 Error: WP at LBA = 0x124300a8fa = 78433528058
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
61 00 08 00 f8 00 00 12 83 d2 d0 40 08 16d+03:43:16.389 WRITE FPDMA QUEUED
|
||||
60 00 08 00 f0 00 00 12 a8 43 f8 40 08 16d+03:43:16.389 READ FPDMA QUEUED
|
||||
61 00 08 00 a8 00 00 0f 9f 54 c8 40 08 16d+03:43:16.389 WRITE FPDMA QUEUED
|
||||
61 00 08 00 a0 00 00 0f 77 36 60 40 08 16d+03:43:16.389 WRITE FPDMA QUEUED
|
||||
61 00 08 00 98 00 00 0f 95 be 98 40 08 16d+03:43:16.389 WRITE FPDMA QUEUED
|
||||
|
||||
Error 130 [9] occurred at disk power-on lifetime: 29640 hours (1235 days + 0 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 00 00 12 43 00 a8 fa 40 00 Error: UNC at LBA = 0x124300a8fa = 78433528058
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 08 00 e0 00 00 12 a8 43 f8 40 08 16d+03:43:13.735 READ FPDMA QUEUED
|
||||
61 00 08 00 a0 00 00 0e 81 d6 f0 40 08 16d+03:43:13.661 WRITE FPDMA QUEUED
|
||||
61 00 08 00 78 00 00 0f 3e dc 48 40 08 16d+03:43:12.127 WRITE FPDMA QUEUED
|
||||
61 00 08 00 d8 00 00 12 83 d2 d0 40 08 16d+03:43:10.596 WRITE FPDMA QUEUED
|
||||
61 00 08 00 90 00 00 0f 92 20 28 40 08 16d+03:43:10.337 WRITE FPDMA QUEUED
|
||||
|
||||
Error 129 [8] occurred at disk power-on lifetime: 29640 hours (1235 days + 0 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 00 00 12 43 00 a8 fa 40 00 Error: WP at LBA = 0x124300a8fa = 78433528058
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
61 00 08 00 b8 00 00 12 9e bc 00 40 08 16d+03:41:24.603 WRITE FPDMA QUEUED
|
||||
61 00 18 00 b0 00 00 12 bb de 80 40 08 16d+03:41:24.603 WRITE FPDMA QUEUED
|
||||
61 00 58 00 80 00 00 12 83 db 48 40 08 16d+03:41:24.603 WRITE FPDMA QUEUED
|
||||
61 00 08 00 08 00 00 12 83 d2 d0 40 08 16d+03:41:24.601 WRITE FPDMA QUEUED
|
||||
61 00 08 00 a8 00 00 12 9e bb c8 40 08 16d+03:41:24.601 WRITE FPDMA QUEUED
|
||||
|
||||
Error 128 [7] occurred at disk power-on lifetime: 29640 hours (1235 days + 0 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 00 00 12 43 00 a8 fa 40 00 Error: UNC at LBA = 0x124300a8fa = 78433528058
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 08 00 38 00 00 12 a8 43 f8 40 08 16d+03:41:22.244 READ FPDMA QUEUED
|
||||
60 00 08 00 30 00 00 12 9d 15 d0 40 08 16d+03:41:22.211 READ FPDMA QUEUED
|
||||
60 00 30 00 28 00 00 12 b2 af 40 40 08 16d+03:41:22.170 READ FPDMA QUEUED
|
||||
60 00 c0 00 20 00 00 12 b2 ae 80 40 08 16d+03:41:22.170 READ FPDMA QUEUED
|
||||
60 01 00 00 f0 00 00 12 b2 ad 80 40 08 16d+03:41:22.169 READ FPDMA QUEUED
|
||||
|
||||
Error 127 [6] occurred at disk power-on lifetime: 29640 hours (1235 days + 0 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 00 00 12 43 00 a8 fa 40 00 Error: WP at LBA = 0x124300a8fa = 78433528058
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
61 00 08 00 f8 00 00 0e 81 d6 f0 40 08 16d+03:41:00.785 WRITE FPDMA QUEUED
|
||||
60 00 08 00 68 00 00 12 a8 43 f8 40 08 16d+03:41:00.785 READ FPDMA QUEUED
|
||||
60 01 00 00 50 00 00 00 10 09 00 40 08 16d+03:41:00.785 READ FPDMA QUEUED
|
||||
61 00 08 00 38 00 00 0f 3e dc 48 40 08 16d+03:41:00.785 WRITE FPDMA QUEUED
|
||||
ef 00 10 00 02 00 00 00 00 00 00 a0 08 16d+03:41:00.785 SET FEATURES [Enable SATA feature]
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: SMART Off-line Data Collection executing in background (4)
|
||||
Current Temperature: 38 Celsius
|
||||
Power Cycle Min/Max Temperature: 36/38 Celsius
|
||||
Lifetime Min/Max Temperature: 27/62 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 128 (58)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000a 2 6 Device-to-host register FISes sent due to a COMRESET
|
||||
0x8000 4 64504 Vendor specific
|
||||
|
170
HDD/WDC/WD6400/WD6400AAKS-65A7B0/9747C44F75AF
Normal file
170
HDD/WDC/WD6400/WD6400AAKS-65A7B0/9747C44F75AF
Normal file
@@ -0,0 +1,170 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.0-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Western Digital Caviar Blue (SATA)
|
||||
Device Model: WDC WD6400AAKS-65A7B0
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 0014ee ...
|
||||
Firmware Version: 01.03B01
|
||||
User Capacity: 640,135,028,736 bytes [640 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 2.5, 3.0 Gb/s
|
||||
Local Time is: Sat Apr 16 11:49:19 2022 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM level is: 128 (quiet), recommended: 128
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Unavailable
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x84) Offline data collection activity
|
||||
was suspended by an interrupting command from host.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: (11580) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 136) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 5) minutes.
|
||||
SCT capabilities: (0x303f) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 153 151 021 - 5350
|
||||
4 Start_Stop_Count -O--CK 087 087 000 - 13306
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 051 - 0
|
||||
9 Power_On_Hours -O--CK 072 072 000 - 20966
|
||||
10 Spin_Retry_Count -O--CK 100 100 051 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 051 - 0
|
||||
12 Power_Cycle_Count -O--CK 089 089 000 - 11505
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 459
|
||||
193 Load_Cycle_Count -O--CK 196 196 000 - 13306
|
||||
194 Temperature_Celsius -O---K 112 101 000 - 35
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate ---R-- 200 200 051 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 6 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
|
||||
0xa8-0xb7 GPL,SL VS 1 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xc1 GPL VS 24 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 20684 -
|
||||
# 2 Short offline Completed without error 00% 14563 -
|
||||
# 3 Short offline Completed without error 00% 13774 -
|
||||
# 4 Short captive Completed without error 00% 13763 -
|
||||
# 5 Short offline Completed without error 00% 9803 -
|
||||
# 6 Short offline Completed without error 00% 453 -
|
||||
# 7 Short offline Completed without error 00% 453 -
|
||||
# 8 Short offline Aborted by host 90% 394 -
|
||||
# 9 Short offline Completed without error 00% 0 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: SMART Off-line Data Collection executing in background (4)
|
||||
Current Temperature: 35 Celsius
|
||||
Power Cycle Min/Max Temperature: 15/35 Celsius
|
||||
Lifetime Min/Max Temperature: 10/45 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 128 (37)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000a 2 26 Device-to-host register FISes sent due to a COMRESET
|
||||
0x8000 4 7735 Vendor specific
|
||||
|
330
HDD/WDC/WD6400/WD6400AARS-00Y5B1/9910127F3522
Normal file
330
HDD/WDC/WD6400/WD6400AARS-00Y5B1/9910127F3522
Normal file
@@ -0,0 +1,330 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.0-RELEASE-p12 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Western Digital Caviar Green (AF)
|
||||
Device Model: WDC WD6400AARS-00Y5B1
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 0014ee ...
|
||||
Firmware Version: 80.00A80
|
||||
User Capacity: 640,135,028,736 bytes [640 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s
|
||||
Local Time is: Wed Aug 10 17:58:31 2022 +04
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: (12660) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 148) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 5) minutes.
|
||||
SCT capabilities: (0x3031) SCT Status supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 130 109 021 - 6458
|
||||
4 Start_Stop_Count -O--CK 096 096 000 - 4862
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 033 033 000 - 49082
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 096 096 000 - 4856
|
||||
192 Power-Off_Retract_Count -O--CK 199 199 000 - 911
|
||||
193 Load_Cycle_Count -O--CK 001 001 000 - 920754
|
||||
194 Temperature_Celsius -O---K 112 098 000 - 35
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 187 187 000 - 1365
|
||||
198 Offline_Uncorrectable ----CK 200 197 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 200 194 000 - 661
|
||||
200 Multi_Zone_Error_Rate ---R-- 200 163 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 6 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
|
||||
0xa8-0xb7 GPL,SL VS 1 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xc1 GPL VS 93 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
|
||||
Device Error Count: 863 (device log contains only the most recent 24 errors)
|
||||
CR = Command Register
|
||||
FEATR = Features Register
|
||||
COUNT = Count (was: Sector Count) Register
|
||||
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
|
||||
LH = LBA High (was: Cylinder High) Register ] LBA
|
||||
LM = LBA Mid (was: Cylinder Low) Register ] Register
|
||||
LL = LBA Low (was: Sector Number) Register ]
|
||||
DV = Device (was: Device/Head) Register
|
||||
DC = Device Control Register
|
||||
ER = Error register
|
||||
ST = Status register
|
||||
Powered_Up_Time is measured from power on, and printed as
|
||||
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
||||
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
||||
|
||||
Error 863 [22] occurred at disk power-on lifetime: 42102 hours (1754 days + 6 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 08 00 00 00 45 0b 42 98 40 00 Error: UNC at LBA = 0x450b4298 = 1158365848
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 08 00 00 88 00 00 45 0b 46 30 40 08 01:49:50.640 READ FPDMA QUEUED
|
||||
60 08 00 00 80 00 00 45 0b 3e 30 40 08 01:49:50.569 READ FPDMA QUEUED
|
||||
60 08 00 00 78 00 00 45 0b 36 30 40 08 01:49:50.477 READ FPDMA QUEUED
|
||||
60 08 00 00 70 00 00 45 0b 2e 30 40 08 01:49:50.398 READ FPDMA QUEUED
|
||||
60 08 00 00 68 00 00 45 0b 26 30 40 08 01:49:50.398 READ FPDMA QUEUED
|
||||
|
||||
Error 862 [21] occurred at disk power-on lifetime: 41638 hours (1734 days + 22 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 08 00 00 00 39 d2 24 30 40 00 Error: UNC at LBA = 0x39d22430 = 970073136
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 08 00 00 c0 00 00 39 d2 1e 60 40 08 43d+18:48:33.825 READ FPDMA QUEUED
|
||||
60 08 00 00 b8 00 00 39 d2 16 60 40 08 43d+18:48:33.757 READ FPDMA QUEUED
|
||||
60 08 00 00 b0 00 00 39 d2 0e 60 40 08 43d+18:48:33.702 READ FPDMA QUEUED
|
||||
60 08 00 00 a8 00 00 39 d1 f6 60 40 08 43d+18:48:33.684 READ FPDMA QUEUED
|
||||
61 00 20 00 a0 00 00 28 b2 7c f0 40 08 43d+18:48:33.683 WRITE FPDMA QUEUED
|
||||
|
||||
Error 861 [20] occurred at disk power-on lifetime: 41447 hours (1726 days + 23 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 08 00 00 00 39 99 cf 68 40 00 Error: UNC at LBA = 0x3999cf68 = 966381416
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 08 00 00 e8 00 00 39 99 ce e0 40 08 35d+19:38:12.395 READ FPDMA QUEUED
|
||||
60 08 00 00 e0 00 00 2a 7e fe 20 40 08 35d+19:38:12.395 READ FPDMA QUEUED
|
||||
60 08 00 00 d8 00 00 2a 7e f6 20 40 08 35d+19:38:12.375 READ FPDMA QUEUED
|
||||
60 08 00 00 d0 00 00 2a 7e ee 20 40 08 35d+19:38:12.375 READ FPDMA QUEUED
|
||||
60 08 00 00 c8 00 00 2a 7e e6 20 40 08 35d+19:38:12.343 READ FPDMA QUEUED
|
||||
|
||||
Error 860 [19] occurred at disk power-on lifetime: 41441 hours (1726 days + 17 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 08 00 00 00 39 d2 24 30 40 00 Error: UNC at LBA = 0x39d22430 = 970073136
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 08 00 00 58 00 00 39 d2 1e 60 40 08 35d+13:38:53.644 READ FPDMA QUEUED
|
||||
2f 00 00 00 01 00 00 00 00 00 10 40 08 35d+13:38:53.643 READ LOG EXT
|
||||
60 08 00 00 48 00 00 39 d2 1e 60 40 08 35d+13:38:50.691 READ FPDMA QUEUED
|
||||
2f 00 00 00 01 00 00 00 00 00 10 40 08 35d+13:38:50.691 READ LOG EXT
|
||||
60 08 00 00 38 00 00 39 d2 1e 60 40 08 35d+13:38:47.317 READ FPDMA QUEUED
|
||||
|
||||
Error 859 [18] occurred at disk power-on lifetime: 41441 hours (1726 days + 17 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 08 00 00 00 39 d2 24 30 40 00 Error: UNC at LBA = 0x39d22430 = 970073136
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 08 00 00 48 00 00 39 d2 1e 60 40 08 35d+13:38:50.691 READ FPDMA QUEUED
|
||||
2f 00 00 00 01 00 00 00 00 00 10 40 08 35d+13:38:50.691 READ LOG EXT
|
||||
60 08 00 00 38 00 00 39 d2 1e 60 40 08 35d+13:38:47.317 READ FPDMA QUEUED
|
||||
2f 00 00 00 01 00 00 00 00 00 10 40 08 35d+13:38:47.316 READ LOG EXT
|
||||
60 08 00 00 28 00 00 39 d2 1e 60 40 08 35d+13:38:44.375 READ FPDMA QUEUED
|
||||
|
||||
Error 858 [17] occurred at disk power-on lifetime: 41441 hours (1726 days + 17 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 08 00 00 00 39 d2 24 30 40 00 Error: UNC at LBA = 0x39d22430 = 970073136
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 08 00 00 38 00 00 39 d2 1e 60 40 08 35d+13:38:47.317 READ FPDMA QUEUED
|
||||
2f 00 00 00 01 00 00 00 00 00 10 40 08 35d+13:38:47.316 READ LOG EXT
|
||||
60 08 00 00 28 00 00 39 d2 1e 60 40 08 35d+13:38:44.375 READ FPDMA QUEUED
|
||||
2f 00 00 00 01 00 00 00 00 00 10 40 08 35d+13:38:44.375 READ LOG EXT
|
||||
60 08 00 00 18 00 00 39 d2 1e 60 40 08 35d+13:38:41.388 READ FPDMA QUEUED
|
||||
|
||||
Error 857 [16] occurred at disk power-on lifetime: 41441 hours (1726 days + 17 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 08 00 00 00 39 d2 24 30 40 00 Error: UNC at LBA = 0x39d22430 = 970073136
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 08 00 00 28 00 00 39 d2 1e 60 40 08 35d+13:38:44.375 READ FPDMA QUEUED
|
||||
2f 00 00 00 01 00 00 00 00 00 10 40 08 35d+13:38:44.375 READ LOG EXT
|
||||
60 08 00 00 18 00 00 39 d2 1e 60 40 08 35d+13:38:41.388 READ FPDMA QUEUED
|
||||
60 00 e0 00 10 00 00 4a 85 7c 20 40 08 35d+13:38:41.385 READ FPDMA QUEUED
|
||||
60 00 e0 00 08 00 00 4a 85 7a 20 40 08 35d+13:38:41.382 READ FPDMA QUEUED
|
||||
|
||||
Error 856 [15] occurred at disk power-on lifetime: 41441 hours (1726 days + 17 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 08 00 00 00 39 d2 24 30 40 00 Error: UNC at LBA = 0x39d22430 = 970073136
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 08 00 00 18 00 00 39 d2 1e 60 40 08 35d+13:38:41.388 READ FPDMA QUEUED
|
||||
60 00 e0 00 10 00 00 4a 85 7c 20 40 08 35d+13:38:41.385 READ FPDMA QUEUED
|
||||
60 00 e0 00 08 00 00 4a 85 7a 20 40 08 35d+13:38:41.382 READ FPDMA QUEUED
|
||||
60 00 e0 00 00 00 00 00 00 0a 20 40 08 35d+13:38:41.368 READ FPDMA QUEUED
|
||||
60 00 e0 00 f8 00 00 00 00 08 20 40 08 35d+13:38:41.357 READ FPDMA QUEUED
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Conveyance offline Completed without error 00% 48584 -
|
||||
# 2 Short offline Completed without error 00% 46364 -
|
||||
# 3 Conveyance offline Completed without error 00% 46364 -
|
||||
# 4 Extended offline Completed without error 00% 45853 -
|
||||
# 5 Short offline Completed without error 00% 45851 -
|
||||
# 6 Conveyance offline Completed without error 00% 45851 -
|
||||
# 7 Conveyance offline Completed without error 00% 42615 -
|
||||
# 8 Conveyance offline Completed without error 00% 42487 -
|
||||
# 9 Extended offline Completed: read failure 10% 42089 1095227040
|
||||
#10 Extended offline Interrupted (host reset) 50% 42081 -
|
||||
#11 Extended offline Interrupted (host reset) 90% 42080 -
|
||||
#12 Short offline Completed without error 00% 42080 -
|
||||
#13 Conveyance offline Completed without error 00% 42079 -
|
||||
#14 Short offline Completed without error 00% 41294 -
|
||||
#15 Conveyance offline Completed without error 00% 41293 -
|
||||
#16 Extended offline Completed without error 00% 36563 -
|
||||
#17 Short offline Completed without error 00% 36561 -
|
||||
#18 Conveyance offline Completed without error 00% 36561 -
|
||||
1 of 1 failed self-tests are outdated by newer successful extended offline self-test # 4
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 35 Celsius
|
||||
Power Cycle Min/Max Temperature: 30/38 Celsius
|
||||
Lifetime Min/Max Temperature: 0/49 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (39)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x8000 4 898043 Vendor specific
|
||||
|
||||
|
||||
|
165
HDD/WDC/WD6400/WD6400BEVT-22A0RT0/918D3541A8D8
Normal file
165
HDD/WDC/WD6400/WD6400BEVT-22A0RT0/918D3541A8D8
Normal file
@@ -0,0 +1,165 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Western Digital Scorpio Blue Serial ATA
|
||||
Device Model: WDC WD6400BEVT-22A0RT0
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 0014ee ...
|
||||
Firmware Version: 01.01A01
|
||||
User Capacity: 640,135,028,736 bytes [640 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: 5400 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s
|
||||
Local Time is: Sun Jun 26 06:32:12 2022 EDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
APM level is: 96 (intermediate level with standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: (14760) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 172) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 5) minutes.
|
||||
SCT capabilities: (0x7037) SCT Status supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 1
|
||||
3 Spin_Up_Time POS--K 185 155 021 - 1750
|
||||
4 Start_Stop_Count -O--CK 096 096 000 - 4074
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 091 091 000 - 6582
|
||||
10 Spin_Retry_Count -O--CK 100 100 051 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 097 097 000 - 3733
|
||||
191 G-Sense_Error_Rate -O--CK 001 001 000 - 2886
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 70
|
||||
193 Load_Cycle_Count -O--CK 182 182 000 - 55921
|
||||
194 Temperature_Celsius -O---K 116 099 000 - 31
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 253 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate ---R-- 100 253 051 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 6 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
|
||||
0xa8-0xb7 GPL,SL VS 1 Device vendor specific log
|
||||
0xbd GPL,SL VS 1 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xc1 GPL VS 24 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 31 Celsius
|
||||
Power Cycle Min/Max Temperature: 22/31 Celsius
|
||||
Lifetime Min/Max Temperature: 23/49 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 128 (21)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000a 2 1 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x8000 4 848 Vendor specific
|
||||
|
180
HDD/WDC/WD6400/WD6400BPVT-60HXZT1/2A73E2259067
Normal file
180
HDD/WDC/WD6400/WD6400BPVT-60HXZT1/2A73E2259067
Normal file
@@ -0,0 +1,180 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Western Digital Scorpio Blue Serial ATA (AF)
|
||||
Device Model: WDC WD6400BPVT-60HXZT1
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 0014ee ...
|
||||
Firmware Version: 01.01A01
|
||||
User Capacity: 640,135,028,736 bytes [640 GB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5400 rpm
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s
|
||||
Local Time is: Sat Jul 23 14:15:21 2022 EDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: (15480) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x51) SMART execute Offline immediate.
|
||||
No Auto Offline data collection support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 152) minutes.
|
||||
SCT capabilities: (0x703d) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 206 202 021 - 666
|
||||
4 Start_Stop_Count -O--CK 098 098 000 - 2110
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate POSR-K 200 200 051 - 0
|
||||
9 Power_On_Hours -O--CK 094 094 000 - 4894
|
||||
10 Spin_Retry_Count PO--CK 100 100 051 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 2107
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error PO--CK 100 100 097 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 077 000 - 195
|
||||
190 Airflow_Temperature_Cel -O---K 065 057 040 - 35 (Min/Max 27/35)
|
||||
191 G-Sense_Error_Rate -O--CK 001 001 000 - 12973
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 50
|
||||
193 Load_Cycle_Count -O--CK 001 001 000 - 613378
|
||||
194 Temperature_Celsius -O---K 112 104 000 - 35
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 253 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate P--R-- 100 253 051 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 6 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
|
||||
0xa8-0xb7 GPL,SL VS 1 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xc1 GPL VS 93 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 4390 -
|
||||
# 2 Short offline Completed without error 00% 3077 -
|
||||
# 3 Short offline Completed without error 00% 2938 -
|
||||
# 4 Short offline Completed without error 00% 2798 -
|
||||
# 5 Short offline Completed without error 00% 2671 -
|
||||
# 6 Short offline Completed without error 00% 2496 -
|
||||
# 7 Short offline Completed without error 00% 2444 -
|
||||
# 8 Short offline Completed without error 00% 2327 -
|
||||
# 9 Short offline Completed without error 00% 2221 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 35 Celsius
|
||||
Power Cycle Min/Max Temperature: 27/35 Celsius
|
||||
Lifetime Min/Max Temperature: 21/43 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 128 (118)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 85 (8.5 seconds)
|
||||
Write: 85 (8.5 seconds)
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x8000 4 2605 Vendor specific
|
||||
|
Reference in New Issue
Block a user