mirror of
https://github.com/bsdhw/SMART.git
synced 2025-05-31 16:21:41 +05:30
Update of reports (new: 3633, modified: 0)
This commit is contained in:
256
HDD/WDC/WD800/WD800AAJS-00PSA0/B1027DE0B20F
Normal file
256
HDD/WDC/WD800/WD800AAJS-00PSA0/B1027DE0B20F
Normal file
@@ -0,0 +1,256 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.0-RELEASE-p12 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Western Digital Caviar Blue Serial ATA
|
||||
Device Model: WDC WD800AAJS-00PSA0
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 0014ee ...
|
||||
Firmware Version: 05.06H05
|
||||
User Capacity: 80,026,361,856 bytes [80.0 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database 7.2/5254
|
||||
ATA Version is: ATA/ATAPI-7 (minor revision not indicated)
|
||||
Local Time is: Sun Aug 14 12:34:19 2022 MSK
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x84) Offline data collection activity
|
||||
was suspended by an interrupting command from host.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 1980) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 30) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 6) minutes.
|
||||
SCT capabilities: (0x103f) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 200 200 051 - 0
|
||||
3 Spin_Up_Time PO---- 158 156 021 - 3058
|
||||
4 Start_Stop_Count -O--CK 099 099 000 - 1260
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-- 200 200 051 - 0
|
||||
9 Power_On_Hours -O--CK 066 066 000 - 25279
|
||||
10 Spin_Retry_Count -O--C- 100 100 051 - 0
|
||||
11 Calibration_Retry_Count -O--C- 100 100 051 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 914
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 318
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 1263
|
||||
194 Temperature_Celsius -O---K 098 093 000 - 45
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--C- 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 200 200 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 163
|
||||
200 Multi_Zone_Error_Rate ---R-- 200 200 051 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 6 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
|
||||
0xa8-0xb7 GPL,SL VS 1 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xc1 GPL VS 12 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
|
||||
Device Error Count: 5
|
||||
CR = Command Register
|
||||
FEATR = Features Register
|
||||
COUNT = Count (was: Sector Count) Register
|
||||
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
|
||||
LH = LBA High (was: Cylinder High) Register ] LBA
|
||||
LM = LBA Mid (was: Cylinder Low) Register ] Register
|
||||
LL = LBA Low (was: Sector Number) Register ]
|
||||
DV = Device (was: Device/Head) Register
|
||||
DC = Device Control Register
|
||||
ER = Error register
|
||||
ST = Status register
|
||||
Powered_Up_Time is measured from power on, and printed as
|
||||
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
||||
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
||||
|
||||
Error 5 [4] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
|
||||
When the command that caused the error occurred, the device was in an unknown state.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 00 01 01 00 51 00 00 40 01 00 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
00 cc 61 ba 62 00 00 00 00 00 08 00 08 00:00:00.000 NOP [Reserved subcommand] [OBS-ACS-2]
|
||||
08 d0 14 00 1e ba c7 09 62 61 00 08 08 00:01:04.472 DEVICE RESET
|
||||
09 c7 60 ba 62 00 c8 08 09 15 08 00 08 1d+16:40:32.711 [RESERVED]
|
||||
08 b8 03 00 72 ba c1 08 62 60 00 08 08 00:00:58.048 DEVICE RESET
|
||||
|
||||
Error 4 [3] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
|
||||
When the command that caused the error occurred, the device was in an unknown state.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 00 01 ff 00 51 00 00 40 01 00 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
00 61 61 ba 62 00 00 00 00 00 08 00 09 00:00:00.000 NOP [Reserved subcommand] [OBS-ACS-2]
|
||||
08 58 03 00 72 ba 61 08 62 60 00 08 08 00:00:13.152 DEVICE RESET
|
||||
09 4e 60 ba 62 00 48 08 f5 14 08 00 08 1d+16:40:32.590 [RESERVED]
|
||||
08 38 13 00 e2 ba 49 09 62 61 00 08 08 00:00:03.136 DEVICE RESET
|
||||
|
||||
Error 3 [2] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
|
||||
When the command that caused the error occurred, the device was in an unknown state.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 00 01 00 00 51 00 00 40 01 00 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
00 7d 60 b9 78 00 00 00 00 00 08 00 08 00:00:00.000 NOP [Reserved subcommand] [OBS-ACS-2]
|
||||
08 a8 0a 00 57 b9 7c 08 78 60 00 08 08 00:00:59.568 DEVICE RESET
|
||||
08 7c 61 b9 78 00 a0 08 31 57 08 00 08 1d+16:39:32.732 DEVICE RESET
|
||||
08 90 7f 00 41 b9 7c 08 78 61 00 08 08 00:00:49.816 DEVICE RESET
|
||||
|
||||
Error 2 [1] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
|
||||
When the command that caused the error occurred, the device was in an unknown state.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 00 01 01 00 51 00 00 40 01 00 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
00 4e 61 b8 d8 00 00 00 00 00 08 00 08 00:00:00.000 NOP [Reserved subcommand] [OBS-ACS-2]
|
||||
08 98 04 00 a7 b8 4e 08 d8 61 00 08 08 00:00:44.960 DEVICE RESET
|
||||
08 4e 61 b8 d8 00 90 08 57 10 08 00 08 1d+16:38:51.726 DEVICE RESET
|
||||
08 80 04 00 73 b8 4e 08 d8 61 00 08 08 00:00:41.352 DEVICE RESET
|
||||
|
||||
Error 1 [0] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
|
||||
When the command that caused the error occurred, the device was in an unknown state.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 00 01 00 00 51 00 00 40 01 00 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
00 5c 60 b8 cb 00 00 00 00 00 08 00 08 00:00:00.000 NOP [Reserved subcommand] [OBS-ACS-2]
|
||||
08 d8 20 00 32 b8 48 08 cb 61 00 08 08 00:00:30.432 DEVICE RESET
|
||||
08 47 60 b8 cb 00 d0 08 ac 03 08 00 08 1d+16:38:48.392 DEVICE RESET
|
||||
08 c0 20 00 12 b8 42 08 cb 61 00 08 08 00:00:56.520 DEVICE RESET
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: SMART Off-line Data Collection executing in background (4)
|
||||
Current Temperature: 46 Celsius
|
||||
Power Cycle Min/Max Temperature: 26/50 Celsius
|
||||
Lifetime Min/Max Temperature: 44/50 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 5/60 Celsius
|
||||
Min/Max Temperature Limit: 1/85 Celsius
|
||||
Temperature History Size (Index): 128 (54)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000a 2 56 Device-to-host register FISes sent due to a COMRESET
|
||||
0x8000 4 3669935 Vendor specific
|
||||
|
||||
|
||||
|
303
HDD/WDC/WD800/WD800AAJS-00PSA0/FF51760C470E
Normal file
303
HDD/WDC/WD800/WD800AAJS-00PSA0/FF51760C470E
Normal file
@@ -0,0 +1,303 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Western Digital Caviar Blue Serial ATA
|
||||
Device Model: WDC WD800AAJS-00PSA0
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 0014ee ...
|
||||
Firmware Version: 05.06H05
|
||||
User Capacity: 80,026,361,856 bytes [80.0 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ATA/ATAPI-7 (minor revision not indicated)
|
||||
Local Time is: Mon Dec 19 02:54:48 2022 CST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM level is: 128 (quiet), recommended: 128
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 1860) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 28) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 6) minutes.
|
||||
SCT capabilities: (0x103f) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 200 200 051 - 195
|
||||
3 Spin_Up_Time PO---- 163 152 021 - 2808
|
||||
4 Start_Stop_Count -O--CK 085 085 000 - 15295
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-- 200 200 051 - 0
|
||||
9 Power_On_Hours -O--CK 029 029 000 - 52374
|
||||
10 Spin_Retry_Count -O--C- 100 100 051 - 0
|
||||
11 Calibration_Retry_Count -O--C- 100 100 051 - 0
|
||||
12 Power_Cycle_Count -O--CK 091 091 000 - 9968
|
||||
192 Power-Off_Retract_Count -O--CK 192 192 000 - 6692
|
||||
193 Load_Cycle_Count -O--CK 195 195 000 - 15324
|
||||
194 Temperature_Celsius -O---K 106 087 000 - 37
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--C- 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 200 200 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 1410
|
||||
200 Multi_Zone_Error_Rate ---R-- 200 200 051 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 6 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
|
||||
0xa8-0xb7 GPL,SL VS 1 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xc1 GPL VS 12 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
|
||||
Device Error Count: 194 (device log contains only the most recent 24 errors)
|
||||
CR = Command Register
|
||||
FEATR = Features Register
|
||||
COUNT = Count (was: Sector Count) Register
|
||||
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
|
||||
LH = LBA High (was: Cylinder High) Register ] LBA
|
||||
LM = LBA Mid (was: Cylinder Low) Register ] Register
|
||||
LL = LBA Low (was: Sector Number) Register ]
|
||||
DV = Device (was: Device/Head) Register
|
||||
DC = Device Control Register
|
||||
ER = Error register
|
||||
ST = Status register
|
||||
Powered_Up_Time is measured from power on, and printed as
|
||||
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
||||
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
||||
|
||||
Error 194 [1] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
|
||||
When the command that caused the error occurred, the device was in an unknown state.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 00 01 00 00 51 00 00 40 00 00 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
00 92 60 03 6d 00 00 00 00 00 00 00 00 00:00:00.000 NOP [Reserved subcommand] [OBS-ACS-2]
|
||||
08 02 10 00 00 03 91 00 6d ef 00 00 08 00:00:47.104 DEVICE RESET
|
||||
00 91 ec 03 6d 00 00 08 00 00 00 00 00 00:03:44.657 NOP [Reserved subcommand] [OBS-ACS-2]
|
||||
08 46 03 00 00 03 91 00 6d ef 00 00 08 00:00:00.000 DEVICE RESET
|
||||
|
||||
Error 193 [0] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
|
||||
When the command that caused the error occurred, the device was in an unknown state.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 00 01 00 00 51 00 00 40 00 00 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
00 a8 60 03 64 00 00 00 00 00 00 00 00 00:00:00.000 NOP [Reserved subcommand] [OBS-ACS-2]
|
||||
08 90 08 00 b0 03 a7 00 64 60 00 00 08 00:00:47.256 DEVICE RESET
|
||||
00 a7 60 03 64 00 88 08 a8 08 00 00 00 00:03:42.375 NOP [Reserved subcommand] [OBS-ACS-2]
|
||||
08 78 08 00 98 03 a7 00 64 60 00 00 08 00:00:41.088 DEVICE RESET
|
||||
|
||||
Error 192 [23] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
|
||||
When the command that caused the error occurred, the device was in an unknown state.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 00 01 00 00 51 00 00 40 00 00 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
00 b9 60 03 5b 00 00 00 00 00 00 00 00 00:00:00.000 NOP [Reserved subcommand] [OBS-ACS-2]
|
||||
08 f0 38 00 40 03 b9 00 5b 60 00 00 08 00:00:32.768 DEVICE RESET
|
||||
00 b9 60 03 5b 00 e8 08 10 08 00 00 00 00:03:40.089 NOP [Reserved subcommand] [OBS-ACS-2]
|
||||
08 d8 08 00 78 03 b8 00 5b 60 00 00 08 00:00:08.416 DEVICE RESET
|
||||
|
||||
Error 191 [22] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
|
||||
When the command that caused the error occurred, the device was in an unknown state.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 00 01 00 00 51 00 00 40 00 00 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
00 55 60 03 53 00 00 00 00 00 00 00 00 00:00:00.000 NOP [Reserved subcommand] [OBS-ACS-2]
|
||||
08 02 10 00 00 03 55 00 53 ef 00 00 08 00:00:47.120 DEVICE RESET
|
||||
00 53 ec 03 53 00 00 08 00 00 00 00 00 00:03:37.941 NOP [Reserved subcommand] [OBS-ACS-2]
|
||||
08 46 03 00 00 03 53 00 53 ef 00 00 08 00:00:00.000 DEVICE RESET
|
||||
|
||||
Error 190 [21] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
|
||||
When the command that caused the error occurred, the device was in an unknown state.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 00 01 00 00 51 00 00 40 00 00 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
00 57 60 03 49 00 00 00 00 00 00 00 00 00:00:00.000 NOP [Reserved subcommand] [OBS-ACS-2]
|
||||
08 a0 08 00 b0 03 57 00 49 60 00 00 08 00:00:47.272 DEVICE RESET
|
||||
00 56 60 03 49 00 98 08 a8 08 00 00 00 00:03:35.382 NOP [Reserved subcommand] [OBS-ACS-2]
|
||||
08 88 08 00 98 03 56 00 49 60 00 00 08 00:00:41.104 DEVICE RESET
|
||||
|
||||
Error 189 [20] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
|
||||
When the command that caused the error occurred, the device was in an unknown state.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 00 01 00 00 51 00 00 40 00 00 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
00 64 60 03 40 00 00 00 00 00 00 00 00 00:00:00.000 NOP [Reserved subcommand] [OBS-ACS-2]
|
||||
08 08 38 00 40 03 63 00 40 60 00 00 08 00:00:32.784 DEVICE RESET
|
||||
00 63 60 03 40 00 00 08 10 08 00 00 00 00:03:33.091 NOP [Reserved subcommand] [OBS-ACS-2]
|
||||
08 e8 08 00 78 03 63 00 40 60 00 00 08 00:00:08.432 DEVICE RESET
|
||||
|
||||
Error 188 [19] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
|
||||
When the command that caused the error occurred, the device was in an unknown state.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 00 01 00 00 51 00 00 40 00 00 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
00 d7 60 03 36 00 00 00 00 00 00 00 00 00:00:00.000 NOP [Reserved subcommand] [OBS-ACS-2]
|
||||
08 02 10 00 00 03 d7 00 36 ef 00 00 08 00:00:47.288 DEVICE RESET
|
||||
00 d6 ec 03 36 00 00 08 00 00 00 00 00 00:03:30.647 NOP [Reserved subcommand] [OBS-ACS-2]
|
||||
08 46 03 00 00 03 d6 00 36 ef 00 00 08 00:00:00.000 DEVICE RESET
|
||||
|
||||
Error 187 [18] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
|
||||
When the command that caused the error occurred, the device was in an unknown state.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 00 01 00 00 51 00 00 40 00 00 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
00 de 60 03 2e 00 00 00 00 00 00 00 00 00:00:00.000 NOP [Reserved subcommand] [OBS-ACS-2]
|
||||
08 50 08 00 b0 03 de 00 2e 60 00 00 08 00:00:47.192 DEVICE RESET
|
||||
00 de 60 03 2e 00 48 08 a8 08 00 00 00 00:03:28.606 NOP [Reserved subcommand] [OBS-ACS-2]
|
||||
08 38 08 00 98 03 de 00 2e 60 00 00 08 00:00:41.024 DEVICE RESET
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Aborted by host 90% 45612 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 37 Celsius
|
||||
Power Cycle Min/Max Temperature: 37/37 Celsius
|
||||
Lifetime Min/Max Temperature: 37/56 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 5/60 Celsius
|
||||
Min/Max Temperature Limit: 1/85 Celsius
|
||||
Temperature History Size (Index): 128 (68)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000a 2 5 Device-to-host register FISes sent due to a COMRESET
|
||||
0x8000 4 638 Vendor specific
|
||||
|
301
HDD/WDC/WD800/WD800JD-60LSA5/8EB991BC0BAC
Normal file
301
HDD/WDC/WD800/WD800JD-60LSA5/8EB991BC0BAC
Normal file
@@ -0,0 +1,301 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.0-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Western Digital Caviar SE Serial ATA
|
||||
Device Model: WDC WD800JD-60LSA5
|
||||
Serial Number: --
|
||||
Firmware Version: 10.01E03
|
||||
User Capacity: 80,026,361,856 bytes [80.0 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ATA/ATAPI-7 (minor revision not indicated)
|
||||
Local Time is: Mon Jul 4 18:15:58 2022 EAT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x84) Offline data collection activity
|
||||
was suspended by an interrupting command from host.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 2700) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 35) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 6) minutes.
|
||||
SCT capabilities: (0x103f) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 200 200 051 - 0
|
||||
3 Spin_Up_Time PO---- 163 160 021 - 2808
|
||||
4 Start_Stop_Count -O--CK 095 095 000 - 5450
|
||||
5 Reallocated_Sector_Ct PO--CK 199 199 140 - 2
|
||||
7 Seek_Error_Rate POSR-- 200 200 051 - 0
|
||||
9 Power_On_Hours -O--CK 049 049 000 - 37336
|
||||
10 Spin_Retry_Count PO--C- 100 100 051 - 0
|
||||
11 Calibration_Retry_Count -O--C- 100 100 051 - 0
|
||||
12 Power_Cycle_Count -O--CK 095 095 000 - 5348
|
||||
190 Airflow_Temperature_Cel -O---K 067 046 045 - 33
|
||||
194 Temperature_Celsius -O---K 110 089 000 - 33
|
||||
196 Reallocated_Event_Count -O--CK 199 199 000 - 1
|
||||
197 Current_Pending_Sector -O--C- 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 200 200 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate P--R-- 200 200 051 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 6 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
|
||||
0xa8-0xb7 GPL,SL VS 1 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
|
||||
Device Error Count: 354 (device log contains only the most recent 24 errors)
|
||||
CR = Command Register
|
||||
FEATR = Features Register
|
||||
COUNT = Count (was: Sector Count) Register
|
||||
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
|
||||
LH = LBA High (was: Cylinder High) Register ] LBA
|
||||
LM = LBA Mid (was: Cylinder Low) Register ] Register
|
||||
LL = LBA Low (was: Sector Number) Register ]
|
||||
DV = Device (was: Device/Head) Register
|
||||
DC = Device Control Register
|
||||
ER = Error register
|
||||
ST = Status register
|
||||
Powered_Up_Time is measured from power on, and printed as
|
||||
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
||||
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
||||
|
||||
Error 354 [17] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
|
||||
When the command that caused the error occurred, the device was in an unknown state.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 00 01 00 00 51 00 00 e0 01 00 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
00 87 c8 0d f2 00 00 00 00 00 00 00 00 00:00:00.000 NOP [Reserved subcommand] [OBS-ACS-2]
|
||||
00 08 00 00 e0 0d 87 04 f2 c8 00 00 00 00:00:43.016 NOP [Abort queued commands]
|
||||
00 30 c8 0d f2 00 00 00 00 00 00 00 00 00:15:13.969 NOP [Reserved subcommand] [OBS-ACS-2]
|
||||
00 10 00 00 c0 0d 30 02 f2 c8 00 00 00 00:00:49.792 NOP [Abort queued commands]
|
||||
|
||||
Error 353 [16] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
|
||||
When the command that caused the error occurred, the device was in an unknown state.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 00 01 00 00 51 00 00 e0 01 00 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
00 2b c8 0d ea 00 00 00 00 00 00 00 00 00:00:00.000 NOP [Reserved subcommand] [OBS-ACS-2]
|
||||
00 40 00 00 a0 0d 1e 04 ea c8 00 00 00 00:00:43.016 NOP [Abort queued commands]
|
||||
00 1e c8 0d ea 00 08 00 4e 00 00 00 02 00:15:11.902 NOP [Reserved subcommand] [OBS-ACS-2]
|
||||
00 02 00 00 a6 0d 0e 00 ea c8 00 00 00 00:01:03.496 NOP [Abort queued commands]
|
||||
|
||||
Error 352 [15] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
|
||||
When the command that caused the error occurred, the device was in an unknown state.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 00 01 00 00 51 00 00 e0 01 00 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
00 04 c8 0d e2 00 00 00 00 00 00 00 00 00:00:00.000 NOP [Reserved subcommand] [OBS-ACS-2]
|
||||
00 40 00 00 60 0d f8 04 e1 c8 00 00 00 00:00:43.016 NOP [Abort queued commands]
|
||||
00 eb c8 0d e1 00 02 00 44 00 00 00 04 00:15:09.815 NOP [Reserved subcommand] [OBS-ACS-2]
|
||||
00 40 00 00 80 0d e5 00 e1 c8 00 00 00 00:00:36.904 NOP [Abort queued commands]
|
||||
|
||||
Error 351 [14] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
|
||||
When the command that caused the error occurred, the device was in an unknown state.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 00 01 00 00 51 00 00 e0 01 00 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
00 88 c8 0d d8 00 00 00 00 00 00 00 00 00:00:00.000 NOP [Reserved subcommand] [OBS-ACS-2]
|
||||
00 40 00 00 20 0d 7b 04 d8 c8 00 00 00 00:00:43.072 NOP [Abort queued commands]
|
||||
03 6f c8 0d d8 00 08 00 80 00 00 00 00 00:15:07.387 CFA REQUEST EXTENDED ERROR
|
||||
00 08 00 00 00 0d 6f 02 d8 c8 00 00 00 00:00:17.024 NOP [Abort queued commands]
|
||||
|
||||
Error 350 [13] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
|
||||
When the command that caused the error occurred, the device was in an unknown state.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 00 01 00 00 51 00 00 e0 01 00 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
00 76 c8 0d d0 00 00 00 00 00 00 00 00 00:00:00.000 NOP [Reserved subcommand] [OBS-ACS-2]
|
||||
00 30 00 00 b0 0d 67 03 d0 c8 00 00 00 00:00:43.016 NOP [Abort queued commands]
|
||||
03 5b c8 0d d0 00 08 00 00 00 00 00 03 00:15:05.319 CFA REQUEST EXTENDED ERROR
|
||||
00 40 00 00 08 0d 5b 03 d0 c8 00 00 00 00:00:45.112 NOP [Abort queued commands]
|
||||
|
||||
Error 349 [12] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
|
||||
When the command that caused the error occurred, the device was in an unknown state.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 00 01 00 00 51 00 00 e0 01 00 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
00 d3 c8 07 29 00 00 00 00 00 00 00 00 00:00:00.000 NOP [Reserved subcommand] [OBS-ACS-2]
|
||||
00 08 00 00 88 07 d3 00 29 ca 00 00 00 00:00:43.016 NOP [Abort queued commands]
|
||||
09 c2 ca 07 29 00 08 00 d8 00 00 00 00 00:07:49.442 [RESERVED]
|
||||
00 08 00 00 7e 07 ad 02 29 c8 00 00 00 00:00:30.952 NOP [Abort queued commands]
|
||||
|
||||
Error 348 [11] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
|
||||
When the command that caused the error occurred, the device was in an unknown state.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 00 01 00 00 51 00 00 e0 01 00 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
00 14 c8 07 22 00 00 00 00 00 00 00 00 00:00:00.000 NOP [Reserved subcommand] [OBS-ACS-2]
|
||||
00 08 00 00 b0 07 0b 02 22 c8 00 00 00 00:00:43.016 NOP [Abort queued commands]
|
||||
00 06 c8 07 22 00 08 00 b0 00 00 00 02 00:07:47.462 NOP [Reserved subcommand] [OBS-ACS-2]
|
||||
00 30 00 00 62 07 f9 00 21 c8 00 00 00 00:00:24.096 NOP [Abort queued commands]
|
||||
|
||||
Error 347 [10] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
|
||||
When the command that caused the error occurred, the device was in an unknown state.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 00 01 00 00 51 00 00 e0 01 00 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
00 84 c8 07 19 00 00 00 00 00 00 00 00 00:00:00.000 NOP [Reserved subcommand] [OBS-ACS-2]
|
||||
00 02 00 00 44 07 84 00 19 c8 00 00 00 00:00:43.016 NOP [Abort queued commands]
|
||||
00 73 c8 07 19 00 40 00 80 00 00 00 00 00:07:45.277 NOP [Reserved subcommand] [OBS-ACS-2]
|
||||
00 08 00 00 30 07 68 00 19 c8 00 00 00 00:00:23.072 NOP [Abort queued commands]
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Aborted by host 90% 37089 -
|
||||
# 2 Short offline Completed: read failure 90% 36463 2400685
|
||||
# 3 Conveyance offline Aborted by host 80% 36461 -
|
||||
# 4 Conveyance offline Aborted by host 90% 36461 -
|
||||
# 5 Short offline Completed: read failure 10% 36329 2400685
|
||||
# 6 Extended offline Completed without error 00% 32311 -
|
||||
# 7 Short offline Completed without error 00% 32311 -
|
||||
# 8 Extended offline Completed without error 00% 32311 -
|
||||
# 9 Short offline Completed without error 00% 32310 -
|
||||
#10 Extended offline Interrupted (host reset) 50% 0 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: SMART Off-line Data Collection executing in background (4)
|
||||
Current Temperature: 33 Celsius
|
||||
Power Cycle Min/Max Temperature: --/34 Celsius
|
||||
Lifetime Min/Max Temperature: --/62 Celsius
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 5/65 Celsius
|
||||
Min/Max Temperature Limit: 1/70 Celsius
|
||||
Temperature History Size (Index): 128 (106)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 75 (7.5 seconds)
|
||||
Write: 75 (7.5 seconds)
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x8000 4 73369 Vendor specific
|
||||
|
295
HDD/WDC/WD800/WD800JD-75MSA3/E4AB6C42EE6C
Normal file
295
HDD/WDC/WD800/WD800JD-75MSA3/E4AB6C42EE6C
Normal file
@@ -0,0 +1,295 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p2 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Western Digital Caviar SE Serial ATA
|
||||
Device Model: WDC WD800JD-75MSA3
|
||||
Serial Number: --
|
||||
Firmware Version: 10.01E04
|
||||
User Capacity: 80,000,000,000 bytes [80.0 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ATA/ATAPI-7 (minor revision not indicated)
|
||||
Local Time is: Thu Sep 15 23:42:13 2022 -03
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM level is: 254 (maximum performance), recommended: 128
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
See vendor-specific Attribute list for marginal Attributes.
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 2460) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 33) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 6) minutes.
|
||||
SCT capabilities: (0x103f) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 200 200 051 - 113
|
||||
3 Spin_Up_Time PO---- 184 158 021 - 1783
|
||||
4 Start_Stop_Count -O--CK 095 095 000 - 5502
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate POSR-- 100 253 051 - 0
|
||||
9 Power_On_Hours -O--CK 046 046 000 - 39678
|
||||
10 Spin_Retry_Count PO--C- 100 100 051 - 0
|
||||
11 Calibration_Retry_Count -O--C- 100 100 051 - 0
|
||||
12 Power_Cycle_Count -O--CK 095 095 000 - 5065
|
||||
190 Airflow_Temperature_Cel -O---K 054 033 045 Past 46
|
||||
194 Temperature_Celsius -O---K 097 076 000 - 46
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--C- 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 200 200 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate P--R-- 200 200 051 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 6 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
|
||||
0xa8-0xb7 GPL,SL VS 1 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
|
||||
Device Error Count: 113 (device log contains only the most recent 24 errors)
|
||||
CR = Command Register
|
||||
FEATR = Features Register
|
||||
COUNT = Count (was: Sector Count) Register
|
||||
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
|
||||
LH = LBA High (was: Cylinder High) Register ] LBA
|
||||
LM = LBA Mid (was: Cylinder Low) Register ] Register
|
||||
LL = LBA Low (was: Sector Number) Register ]
|
||||
DV = Device (was: Device/Head) Register
|
||||
DC = Device Control Register
|
||||
ER = Error register
|
||||
ST = Status register
|
||||
Powered_Up_Time is measured from power on, and printed as
|
||||
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
||||
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
||||
|
||||
Error 113 [16] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
|
||||
When the command that caused the error occurred, the device was in an unknown state.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 00 01 00 00 51 00 00 e0 01 00 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
00 99 c8 02 db 00 00 00 00 00 00 00 00 00:00:00.000 NOP [Reserved subcommand] [OBS-ACS-2]
|
||||
00 80 00 00 a0 02 3a 00 d4 c8 00 00 00 00:00:41.088 NOP [Abort queued commands]
|
||||
00 d3 c8 02 cc 00 80 00 20 00 00 00 00 00:03:05.402 NOP [Reserved subcommand] [OBS-ACS-2]
|
||||
00 00 00 00 20 02 39 00 c5 c8 00 00 00 00:00:08.192 NOP [Abort queued commands]
|
||||
|
||||
Error 112 [15] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
|
||||
When the command that caused the error occurred, the device was in an unknown state.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 00 01 00 00 51 00 00 e0 01 00 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
00 3a c8 02 d4 00 00 00 00 00 00 00 00 00:00:00.000 NOP [Reserved subcommand] [OBS-ACS-2]
|
||||
00 80 00 00 20 02 3a 00 d4 c8 00 00 00 00:00:41.088 NOP [Abort queued commands]
|
||||
00 39 c8 02 c5 00 00 00 20 00 00 00 00 00:03:03.507 NOP [Reserved subcommand] [OBS-ACS-2]
|
||||
00 00 00 00 20 02 39 00 c5 c8 00 00 00 00:00:08.192 NOP [Abort queued commands]
|
||||
|
||||
Error 111 [14] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
|
||||
When the command that caused the error occurred, the device was in an unknown state.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 00 01 00 00 51 00 00 e0 01 00 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
00 d3 c8 02 cc 00 00 00 00 00 00 00 00 00:00:00.000 NOP [Reserved subcommand] [OBS-ACS-2]
|
||||
00 00 00 00 20 02 39 00 c5 c8 00 00 00 00:00:08.192 NOP [Abort queued commands]
|
||||
00 0b c8 02 bd 00 00 00 20 00 00 00 00 00:03:01.561 NOP [Reserved subcommand] [OBS-ACS-2]
|
||||
00 00 00 00 20 02 0b 00 bd c8 00 00 00 00:00:08.192 NOP [Abort queued commands]
|
||||
|
||||
Error 110 [13] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
|
||||
When the command that caused the error occurred, the device was in an unknown state.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 00 01 00 00 51 00 00 e0 01 00 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
00 39 c8 02 c5 00 00 00 00 00 00 00 00 00:00:00.000 NOP [Reserved subcommand] [OBS-ACS-2]
|
||||
00 00 00 00 20 02 39 00 c5 c8 00 00 00 00:00:08.192 NOP [Abort queued commands]
|
||||
00 0b c8 02 bd 00 00 00 20 00 00 00 00 00:02:59.467 NOP [Reserved subcommand] [OBS-ACS-2]
|
||||
00 00 00 00 20 02 73 00 b5 c8 00 00 00 00:00:08.192 NOP [Abort queued commands]
|
||||
|
||||
Error 109 [12] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
|
||||
When the command that caused the error occurred, the device was in an unknown state.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 00 01 00 00 51 00 00 e0 01 00 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
00 0b c8 02 bd 00 00 00 00 00 00 00 00 00:00:00.000 NOP [Reserved subcommand] [OBS-ACS-2]
|
||||
00 00 00 00 20 02 0b 00 bd c8 00 00 00 00:00:08.192 NOP [Abort queued commands]
|
||||
00 72 c8 02 b5 00 00 00 20 00 00 00 00 00:02:57.523 NOP [Reserved subcommand] [OBS-ACS-2]
|
||||
00 00 00 00 20 02 71 00 b5 c8 00 00 00 00:00:08.192 NOP [Abort queued commands]
|
||||
|
||||
Error 108 [11] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
|
||||
When the command that caused the error occurred, the device was in an unknown state.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 00 01 00 00 51 00 00 e0 01 00 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
00 73 c8 02 b5 00 00 00 00 00 00 00 00 00:00:00.000 NOP [Reserved subcommand] [OBS-ACS-2]
|
||||
00 00 00 00 20 02 72 00 b5 c8 00 00 00 00:00:08.192 NOP [Abort queued commands]
|
||||
00 71 c8 02 b5 00 00 00 20 00 00 00 00 00:02:57.521 NOP [Reserved subcommand] [OBS-ACS-2]
|
||||
00 00 00 00 20 02 e9 00 ad c8 00 00 00 00:00:08.192 NOP [Abort queued commands]
|
||||
|
||||
Error 107 [10] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
|
||||
When the command that caused the error occurred, the device was in an unknown state.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 00 01 00 00 51 00 00 e0 01 00 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
00 e9 c8 02 ad 00 00 00 00 00 00 00 00 00:00:00.000 NOP [Reserved subcommand] [OBS-ACS-2]
|
||||
00 00 00 00 20 02 e8 00 ad c8 00 00 00 00:00:08.192 NOP [Abort queued commands]
|
||||
00 e7 c8 02 ad 00 00 00 20 00 00 00 00 00:02:55.591 NOP [Reserved subcommand] [OBS-ACS-2]
|
||||
00 00 00 00 20 02 b1 00 a5 c8 00 00 00 00:00:08.192 NOP [Abort queued commands]
|
||||
|
||||
Error 106 [9] occurred at disk power-on lifetime: 0 hours (0 days + 0 hours)
|
||||
When the command that caused the error occurred, the device was in an unknown state.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 00 01 00 00 51 00 00 e0 01 00 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
00 b1 c8 02 a5 00 00 00 00 00 00 00 00 00:00:00.000 NOP [Reserved subcommand] [OBS-ACS-2]
|
||||
00 00 00 00 20 02 b1 00 a5 c8 00 00 00 00:00:08.192 NOP [Abort queued commands]
|
||||
00 af c8 02 a5 00 00 00 20 00 00 00 00 00:02:53.488 NOP [Reserved subcommand] [OBS-ACS-2]
|
||||
00 00 00 00 20 02 af 00 a5 c8 00 00 00 00:00:08.192 NOP [Abort queued commands]
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Extended offline Completed without error 00% 24653 -
|
||||
# 2 Short offline Completed without error 00% 0 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 46 Celsius
|
||||
Power Cycle Min/Max Temperature: --/53 Celsius
|
||||
Lifetime Min/Max Temperature: --/68 Celsius
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 5/65 Celsius
|
||||
Min/Max Temperature Limit: 1/70 Celsius
|
||||
Temperature History Size (Index): 128 (44)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x000a 2 1 Device-to-host register FISes sent due to a COMRESET
|
||||
0x8000 4 55447 Vendor specific
|
||||
|
Reference in New Issue
Block a user