mirror of
https://github.com/bsdhw/SMART.git
synced 2025-05-31 16:21:41 +05:30
Update of reports (new: 3633, modified: 0)
This commit is contained in:
66
NVMe/Plextor/PX-256/PX-256M9PeY/86FAEE1ACC09
Normal file
66
NVMe/Plextor/PX-256/PX-256M9PeY/86FAEE1ACC09
Normal file
@@ -0,0 +1,66 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.0-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Number: PLEXTOR PX-256M9PeY
|
||||
Serial Number: --
|
||||
Firmware Version: 1.05
|
||||
PCI Vendor ID: 0x14a4
|
||||
PCI Vendor Subsystem ID: 0x1b4b
|
||||
IEEE OUI Identifier: 0x002303
|
||||
Total NVM Capacity: 256,060,514,304 [256 GB]
|
||||
Unallocated NVM Capacity: 0
|
||||
Controller ID: 1
|
||||
NVMe Version: 1.2
|
||||
Number of Namespaces: 1
|
||||
Namespace 1 Size/Capacity: 256,060,514,304 [256 GB]
|
||||
Namespace 1 Formatted LBA Size: 512
|
||||
Namespace 1 IEEE EUI-64: 002303 ...
|
||||
Local Time is: Mon Jul 11 17:46:24 2022 CST
|
||||
Firmware Updates (0x14): 2 Slots, no Reset required
|
||||
Optional Admin Commands (0x001f): Security Format Frmw_DL NS_Mngmt Self_Test
|
||||
Optional NVM Commands (0x001f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat
|
||||
Log Page Attributes (0x03): S/H_per_NS Cmd_Eff_Lg
|
||||
Maximum Data Transfer Size: 32 Pages
|
||||
Warning Comp. Temp. Threshold: 83 Celsius
|
||||
Critical Comp. Temp. Threshold: 85 Celsius
|
||||
|
||||
Supported Power States
|
||||
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
|
||||
0 + 8.00W - - 0 0 0 0 0 0
|
||||
1 + 4.50W - - 1 1 1 1 5 5
|
||||
2 + 3.00W - - 2 2 2 2 5 5
|
||||
3 - 0.0700W - - 3 3 3 3 1000 5000
|
||||
4 - 0.0100W - - 4 4 4 4 5000 50000
|
||||
|
||||
Supported LBA Sizes (NSID 0x1)
|
||||
Id Fmt Data Metadt Rel_Perf
|
||||
0 - 512 0 1
|
||||
1 - 4096 0 0
|
||||
|
||||
=== START OF SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
SMART/Health Information (NVMe Log 0x02)
|
||||
Critical Warning: 0x00
|
||||
Temperature: 70 Celsius
|
||||
Available Spare: 100%
|
||||
Available Spare Threshold: 0%
|
||||
Percentage Used: 2%
|
||||
Data Units Read: 24,369,416 [12.4 TB]
|
||||
Data Units Written: 24,640,836 [12.6 TB]
|
||||
Host Read Commands: 431,069,049
|
||||
Host Write Commands: 372,542,077
|
||||
Controller Busy Time: 154,295
|
||||
Power Cycles: 1,646
|
||||
Power On Hours: 5,886
|
||||
Unsafe Shutdowns: 313
|
||||
Media and Data Integrity Errors: 0
|
||||
Error Information Log Entries: 0
|
||||
Warning Comp. Temperature Time: 0
|
||||
Critical Comp. Temperature Time: 0
|
||||
Temperature Sensor 1: 70 Celsius
|
||||
|
||||
Error Information (NVMe Log 0x01, 16 of 64 entries)
|
||||
No Errors Logged
|
||||
|
Reference in New Issue