mirror of
https://github.com/bsdhw/SMART.git
synced 2025-05-31 16:21:41 +05:30
Update of reports (new: 3633, modified: 0)
This commit is contained in:
65
NVMe/SSSTC/CL1/CL1-3D256-Q11 NVMe 256GB/75D6B65DD614
Normal file
65
NVMe/SSSTC/CL1/CL1-3D256-Q11 NVMe 256GB/75D6B65DD614
Normal file
@@ -0,0 +1,65 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Number: CL1-3D256-Q11 NVMe SSSTC 256GB
|
||||
Serial Number: --
|
||||
Firmware Version: 22301116
|
||||
PCI Vendor ID: 0x1e95
|
||||
PCI Vendor Subsystem ID: 0x126f
|
||||
IEEE OUI Identifier: 0x38f601
|
||||
Total NVM Capacity: 256,060,514,304 [256 GB]
|
||||
Unallocated NVM Capacity: 0
|
||||
Controller ID: 1
|
||||
NVMe Version: 1.3
|
||||
Number of Namespaces: 1
|
||||
Namespace 1 Size/Capacity: 256,060,514,304 [256 GB]
|
||||
Namespace 1 Formatted LBA Size: 512
|
||||
Namespace 1 IEEE EUI-64: 38f601 ...
|
||||
Local Time is: Fri Jul 1 11:45:28 2022 PDT
|
||||
Firmware Updates (0x14): 2 Slots, no Reset required
|
||||
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
|
||||
Optional NVM Commands (0x001f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat
|
||||
Log Page Attributes (0x07): S/H_per_NS Cmd_Eff_Lg Ext_Get_Lg
|
||||
Maximum Data Transfer Size: 32 Pages
|
||||
Warning Comp. Temp. Threshold: 83 Celsius
|
||||
Critical Comp. Temp. Threshold: 85 Celsius
|
||||
|
||||
Supported Power States
|
||||
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
|
||||
0 + 3.50W - - 0 0 0 0 0 0
|
||||
1 + 2.10W - - 1 1 1 1 0 0
|
||||
2 + 1.65W - - 2 2 2 2 0 0
|
||||
3 - 0.0500W - - 3 3 3 3 5000 5000
|
||||
4 - 0.0050W - - 4 4 4 4 5000 20000
|
||||
|
||||
Supported LBA Sizes (NSID 0x1)
|
||||
Id Fmt Data Metadt Rel_Perf
|
||||
0 + 512 0 0
|
||||
|
||||
=== START OF SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
SMART/Health Information (NVMe Log 0x02)
|
||||
Critical Warning: 0x00
|
||||
Temperature: 23 Celsius
|
||||
Available Spare: 100%
|
||||
Available Spare Threshold: 50%
|
||||
Percentage Used: 12%
|
||||
Data Units Read: 11,009,575 [5.63 TB]
|
||||
Data Units Written: 20,804,450 [10.6 TB]
|
||||
Host Read Commands: 97,998,129
|
||||
Host Write Commands: 308,807,472
|
||||
Controller Busy Time: 2,369
|
||||
Power Cycles: 267
|
||||
Power On Hours: 10,231
|
||||
Unsafe Shutdowns: 196
|
||||
Media and Data Integrity Errors: 0
|
||||
Error Information Log Entries: 0
|
||||
Warning Comp. Temperature Time: 0
|
||||
Critical Comp. Temperature Time: 0
|
||||
Temperature Sensor 1: 23 Celsius
|
||||
|
||||
Error Information (NVMe Log 0x01, 16 of 64 entries)
|
||||
No Errors Logged
|
||||
|
65
NVMe/SSSTC/CL1/CL1-4D128/8495096ADE22
Normal file
65
NVMe/SSSTC/CL1/CL1-4D128/8495096ADE22
Normal file
@@ -0,0 +1,65 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Number: SSSTC CL1-4D128
|
||||
Serial Number: --
|
||||
Firmware Version: 1S262
|
||||
PCI Vendor ID: 0x1e95
|
||||
PCI Vendor Subsystem ID: 0x126f
|
||||
IEEE OUI Identifier: 0x38f601
|
||||
Total NVM Capacity: 128,035,676,160 [128 GB]
|
||||
Unallocated NVM Capacity: 0
|
||||
Controller ID: 1
|
||||
NVMe Version: 1.3
|
||||
Number of Namespaces: 1
|
||||
Namespace 1 Size/Capacity: 128,035,676,160 [128 GB]
|
||||
Namespace 1 Formatted LBA Size: 512
|
||||
Namespace 1 IEEE EUI-64: 38f601 ...
|
||||
Local Time is: Sun May 29 23:04:11 2022 EDT
|
||||
Firmware Updates (0x14): 2 Slots, no Reset required
|
||||
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
|
||||
Optional NVM Commands (0x001f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat
|
||||
Log Page Attributes (0x0f): S/H_per_NS Cmd_Eff_Lg Ext_Get_Lg Telmtry_Lg
|
||||
Maximum Data Transfer Size: 32 Pages
|
||||
Warning Comp. Temp. Threshold: 84 Celsius
|
||||
Critical Comp. Temp. Threshold: 85 Celsius
|
||||
|
||||
Supported Power States
|
||||
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
|
||||
0 + 3.50W - - 0 0 0 0 0 0
|
||||
1 + 2.10W - - 1 1 1 1 0 0
|
||||
2 + 1.65W - - 2 2 2 2 0 0
|
||||
3 - 0.0500W - - 3 3 3 3 5000 5000
|
||||
4 - 0.0050W - - 4 4 4 4 5000 20000
|
||||
|
||||
Supported LBA Sizes (NSID 0x1)
|
||||
Id Fmt Data Metadt Rel_Perf
|
||||
0 + 512 0 0
|
||||
|
||||
=== START OF SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
SMART/Health Information (NVMe Log 0x02)
|
||||
Critical Warning: 0x00
|
||||
Temperature: 25 Celsius
|
||||
Available Spare: 100%
|
||||
Available Spare Threshold: 10%
|
||||
Percentage Used: 1%
|
||||
Data Units Read: 2,311,182 [1.18 TB]
|
||||
Data Units Written: 1,365,775 [699 GB]
|
||||
Host Read Commands: 35,352,358
|
||||
Host Write Commands: 14,711,481
|
||||
Controller Busy Time: 446
|
||||
Power Cycles: 145
|
||||
Power On Hours: 88
|
||||
Unsafe Shutdowns: 47
|
||||
Media and Data Integrity Errors: 0
|
||||
Error Information Log Entries: 0
|
||||
Warning Comp. Temperature Time: 0
|
||||
Critical Comp. Temperature Time: 0
|
||||
Temperature Sensor 1: 25 Celsius
|
||||
|
||||
Error Information (NVMe Log 0x01, 16 of 64 entries)
|
||||
No Errors Logged
|
||||
|
65
NVMe/SSSTC/CL1/CL1-4D256/94696A5957CB
Normal file
65
NVMe/SSSTC/CL1/CL1-4D256/94696A5957CB
Normal file
@@ -0,0 +1,65 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Number: SSSTC CL1-4D256
|
||||
Serial Number: --
|
||||
Firmware Version: 1S262
|
||||
PCI Vendor ID: 0x1e95
|
||||
PCI Vendor Subsystem ID: 0x126f
|
||||
IEEE OUI Identifier: 0x38f601
|
||||
Total NVM Capacity: 256,060,514,304 [256 GB]
|
||||
Unallocated NVM Capacity: 0
|
||||
Controller ID: 1
|
||||
NVMe Version: 1.3
|
||||
Number of Namespaces: 1
|
||||
Namespace 1 Size/Capacity: 256,060,514,304 [256 GB]
|
||||
Namespace 1 Formatted LBA Size: 512
|
||||
Namespace 1 IEEE EUI-64: 38f601 ...
|
||||
Local Time is: Sat Jul 23 09:56:36 2022 EDT
|
||||
Firmware Updates (0x14): 2 Slots, no Reset required
|
||||
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
|
||||
Optional NVM Commands (0x001f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat
|
||||
Log Page Attributes (0x0f): S/H_per_NS Cmd_Eff_Lg Ext_Get_Lg Telmtry_Lg
|
||||
Maximum Data Transfer Size: 32 Pages
|
||||
Warning Comp. Temp. Threshold: 84 Celsius
|
||||
Critical Comp. Temp. Threshold: 85 Celsius
|
||||
|
||||
Supported Power States
|
||||
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
|
||||
0 + 3.50W - - 0 0 0 0 0 0
|
||||
1 + 2.10W - - 1 1 1 1 0 0
|
||||
2 + 1.65W - - 2 2 2 2 0 0
|
||||
3 - 0.0500W - - 3 3 3 3 5000 5000
|
||||
4 - 0.0050W - - 4 4 4 4 5000 20000
|
||||
|
||||
Supported LBA Sizes (NSID 0x1)
|
||||
Id Fmt Data Metadt Rel_Perf
|
||||
0 + 512 0 0
|
||||
|
||||
=== START OF SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
SMART/Health Information (NVMe Log 0x02)
|
||||
Critical Warning: 0x00
|
||||
Temperature: 29 Celsius
|
||||
Available Spare: 100%
|
||||
Available Spare Threshold: 10%
|
||||
Percentage Used: 15%
|
||||
Data Units Read: 26,298,047 [13.4 TB]
|
||||
Data Units Written: 19,434,437 [9.95 TB]
|
||||
Host Read Commands: 314,986,844
|
||||
Host Write Commands: 336,750,566
|
||||
Controller Busy Time: 5,228
|
||||
Power Cycles: 1,349
|
||||
Power On Hours: 8,486
|
||||
Unsafe Shutdowns: 389
|
||||
Media and Data Integrity Errors: 0
|
||||
Error Information Log Entries: 0
|
||||
Warning Comp. Temperature Time: 0
|
||||
Critical Comp. Temperature Time: 0
|
||||
Temperature Sensor 1: 29 Celsius
|
||||
|
||||
Error Information (NVMe Log 0x01, 16 of 64 entries)
|
||||
No Errors Logged
|
||||
|
65
NVMe/SSSTC/CL1/CL1-4D256/C1A16F4D6EA5
Normal file
65
NVMe/SSSTC/CL1/CL1-4D256/C1A16F4D6EA5
Normal file
@@ -0,0 +1,65 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Number: SSSTC CL1-4D256
|
||||
Serial Number: --
|
||||
Firmware Version: BS262
|
||||
PCI Vendor ID: 0x1e95
|
||||
PCI Vendor Subsystem ID: 0x126f
|
||||
IEEE OUI Identifier: 0x38f601
|
||||
Total NVM Capacity: 256,060,514,304 [256 GB]
|
||||
Unallocated NVM Capacity: 0
|
||||
Controller ID: 1
|
||||
NVMe Version: 1.3
|
||||
Number of Namespaces: 1
|
||||
Namespace 1 Size/Capacity: 256,060,514,304 [256 GB]
|
||||
Namespace 1 Formatted LBA Size: 512
|
||||
Namespace 1 IEEE EUI-64: 38f601 ...
|
||||
Local Time is: Mon Feb 6 18:07:18 2023 UTC
|
||||
Firmware Updates (0x14): 2 Slots, no Reset required
|
||||
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
|
||||
Optional NVM Commands (0x001f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat
|
||||
Log Page Attributes (0x0f): S/H_per_NS Cmd_Eff_Lg Ext_Get_Lg Telmtry_Lg
|
||||
Maximum Data Transfer Size: 32 Pages
|
||||
Warning Comp. Temp. Threshold: 84 Celsius
|
||||
Critical Comp. Temp. Threshold: 85 Celsius
|
||||
|
||||
Supported Power States
|
||||
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
|
||||
0 + 3.50W - - 0 0 0 0 0 0
|
||||
1 + 2.10W - - 1 1 1 1 0 0
|
||||
2 + 1.65W - - 2 2 2 2 0 0
|
||||
3 - 0.0500W - - 3 3 3 3 5000 5000
|
||||
4 - 0.0050W - - 4 4 4 4 5000 20000
|
||||
|
||||
Supported LBA Sizes (NSID 0x1)
|
||||
Id Fmt Data Metadt Rel_Perf
|
||||
0 + 512 0 0
|
||||
|
||||
=== START OF SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
SMART/Health Information (NVMe Log 0x02)
|
||||
Critical Warning: 0x00
|
||||
Temperature: 30 Celsius
|
||||
Available Spare: 100%
|
||||
Available Spare Threshold: 10%
|
||||
Percentage Used: 0%
|
||||
Data Units Read: 953,065 [487 GB]
|
||||
Data Units Written: 2,581,037 [1.32 TB]
|
||||
Host Read Commands: 13,513,376
|
||||
Host Write Commands: 34,973,612
|
||||
Controller Busy Time: 208
|
||||
Power Cycles: 332
|
||||
Power On Hours: 297
|
||||
Unsafe Shutdowns: 96
|
||||
Media and Data Integrity Errors: 0
|
||||
Error Information Log Entries: 0
|
||||
Warning Comp. Temperature Time: 0
|
||||
Critical Comp. Temperature Time: 0
|
||||
Temperature Sensor 1: 30 Celsius
|
||||
|
||||
Error Information (NVMe Log 0x01, 16 of 64 entries)
|
||||
No Errors Logged
|
||||
|
65
NVMe/SSSTC/CL1/CL1-8D256-HP/241C94823B59
Normal file
65
NVMe/SSSTC/CL1/CL1-8D256-HP/241C94823B59
Normal file
@@ -0,0 +1,65 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Number: SSSTC CL1-8D256-HP
|
||||
Serial Number: --
|
||||
Firmware Version: L183
|
||||
PCI Vendor ID: 0x1e95
|
||||
PCI Vendor Subsystem ID: 0x126f
|
||||
IEEE OUI Identifier: 0x38f601
|
||||
Total NVM Capacity: 256,060,514,304 [256 GB]
|
||||
Unallocated NVM Capacity: 0
|
||||
Controller ID: 1
|
||||
NVMe Version: 1.3
|
||||
Number of Namespaces: 1
|
||||
Namespace 1 Size/Capacity: 256,060,514,304 [256 GB]
|
||||
Namespace 1 Formatted LBA Size: 512
|
||||
Namespace 1 IEEE EUI-64: 38f601 ...
|
||||
Local Time is: Tue Dec 13 22:52:45 2022 MSK
|
||||
Firmware Updates (0x14): 2 Slots, no Reset required
|
||||
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
|
||||
Optional NVM Commands (0x001f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat
|
||||
Log Page Attributes (0x07): S/H_per_NS Cmd_Eff_Lg Ext_Get_Lg
|
||||
Maximum Data Transfer Size: 64 Pages
|
||||
Warning Comp. Temp. Threshold: 84 Celsius
|
||||
Critical Comp. Temp. Threshold: 85 Celsius
|
||||
|
||||
Supported Power States
|
||||
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
|
||||
0 + 3.50W - - 0 0 0 0 0 0
|
||||
1 + 2.10W - - 1 1 1 1 0 0
|
||||
2 + 1.65W - - 2 2 2 2 0 0
|
||||
3 - 0.0500W - - 3 3 3 3 5000 5000
|
||||
4 - 0.0050W - - 4 4 4 4 5000 20000
|
||||
|
||||
Supported LBA Sizes (NSID 0x1)
|
||||
Id Fmt Data Metadt Rel_Perf
|
||||
0 + 512 0 0
|
||||
|
||||
=== START OF SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
SMART/Health Information (NVMe Log 0x02)
|
||||
Critical Warning: 0x00
|
||||
Temperature: 29 Celsius
|
||||
Available Spare: 100%
|
||||
Available Spare Threshold: 5%
|
||||
Percentage Used: 4%
|
||||
Data Units Read: 3,764,933 [1.92 TB]
|
||||
Data Units Written: 21,273,953 [10.8 TB]
|
||||
Host Read Commands: 32,804,792
|
||||
Host Write Commands: 339,069,770
|
||||
Controller Busy Time: 2,472
|
||||
Power Cycles: 238
|
||||
Power On Hours: 2,126
|
||||
Unsafe Shutdowns: 129
|
||||
Media and Data Integrity Errors: 0
|
||||
Error Information Log Entries: 0
|
||||
Warning Comp. Temperature Time: 0
|
||||
Critical Comp. Temperature Time: 0
|
||||
Temperature Sensor 1: 29 Celsius
|
||||
|
||||
Error Information (NVMe Log 0x01, 16 of 64 entries)
|
||||
No Errors Logged
|
||||
|
65
NVMe/SSSTC/CL1/CL1-8D256/C5ECF1770C8E
Normal file
65
NVMe/SSSTC/CL1/CL1-8D256/C5ECF1770C8E
Normal file
@@ -0,0 +1,65 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p5 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Number: SSSTC CL1-8D256
|
||||
Serial Number: --
|
||||
Firmware Version: CT22102
|
||||
PCI Vendor ID: 0x1e95
|
||||
PCI Vendor Subsystem ID: 0x126f
|
||||
IEEE OUI Identifier: 0x38f601
|
||||
Total NVM Capacity: 256,060,514,304 [256 GB]
|
||||
Unallocated NVM Capacity: 0
|
||||
Controller ID: 1
|
||||
NVMe Version: 1.3
|
||||
Number of Namespaces: 1
|
||||
Namespace 1 Size/Capacity: 256,060,514,304 [256 GB]
|
||||
Namespace 1 Formatted LBA Size: 512
|
||||
Namespace 1 IEEE EUI-64: 002303 ...
|
||||
Local Time is: Tue Jan 17 22:26:35 2023 CET
|
||||
Firmware Updates (0x14): 2 Slots, no Reset required
|
||||
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
|
||||
Optional NVM Commands (0x001f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat
|
||||
Log Page Attributes (0x07): S/H_per_NS Cmd_Eff_Lg Ext_Get_Lg
|
||||
Maximum Data Transfer Size: 32 Pages
|
||||
Warning Comp. Temp. Threshold: 84 Celsius
|
||||
Critical Comp. Temp. Threshold: 85 Celsius
|
||||
|
||||
Supported Power States
|
||||
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
|
||||
0 + 3.50W - - 0 0 0 0 0 0
|
||||
1 + 2.10W - - 1 1 1 1 0 0
|
||||
2 + 1.65W - - 2 2 2 2 0 0
|
||||
3 - 0.0500W - - 3 3 3 3 5000 5000
|
||||
4 - 0.0050W - - 4 4 4 4 5000 20000
|
||||
|
||||
Supported LBA Sizes (NSID 0x1)
|
||||
Id Fmt Data Metadt Rel_Perf
|
||||
0 + 512 0 0
|
||||
|
||||
=== START OF SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
SMART/Health Information (NVMe Log 0x02)
|
||||
Critical Warning: 0x00
|
||||
Temperature: 49 Celsius
|
||||
Available Spare: 100%
|
||||
Available Spare Threshold: 10%
|
||||
Percentage Used: 0%
|
||||
Data Units Read: 11,215 [5.74 GB]
|
||||
Data Units Written: 97,652 [49.9 GB]
|
||||
Host Read Commands: 252,032
|
||||
Host Write Commands: 1,345,555
|
||||
Controller Busy Time: 14
|
||||
Power Cycles: 8
|
||||
Power On Hours: 60
|
||||
Unsafe Shutdowns: 6
|
||||
Media and Data Integrity Errors: 0
|
||||
Error Information Log Entries: 0
|
||||
Warning Comp. Temperature Time: 0
|
||||
Critical Comp. Temperature Time: 0
|
||||
Temperature Sensor 1: 49 Celsius
|
||||
|
||||
Error Information (NVMe Log 0x01, 16 of 64 entries)
|
||||
No Errors Logged
|
||||
|
Reference in New Issue
Block a user