smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.0-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Crucial/Micron Client SSDs
|
||||
Device Model: Crucial_CT275MX300SSD1
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 00a075 ...
|
||||
Firmware Version: M0CR040
|
||||
User Capacity: 275,064,201,216 bytes [275 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
Form Factor: 2.5 inches
|
||||
TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Mon May 30 14:51:06 2022 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 254 (maximum performance)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x03) Offline data collection activity
|
||||
is in progress.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 692) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 5) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 3) minutes.
|
||||
SCT capabilities: (0x0035) SCT Status supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 000 - 0
|
||||
5 Reallocate_NAND_Blk_Cnt -O--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 41374
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 54
|
||||
171 Program_Fail_Count -O--CK 100 100 000 - 0
|
||||
172 Erase_Fail_Count -O--CK 100 100 000 - 0
|
||||
173 Ave_Block-Erase_Count -O--CK 053 053 000 - 707
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 38
|
||||
183 SATA_Interfac_Downshift -O--CK 100 100 000 - 0
|
||||
184 Error_Correction_Count -O--CK 100 100 000 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
194 Temperature_Celsius -O---K 048 032 000 - 52 (Min/Max 19/68)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_ECC_Cnt -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0
|
||||
202 Percent_Lifetime_Remain ----CK 053 053 001 - 47
|
||||
206 Write_Error_Rate -OSR-- 100 100 000 - 0
|
||||
246 Total_LBAs_Written -O--CK 100 100 000 - 192368826458
|
||||
247 Host_Program_Page_Count -O--CK 100 100 000 - 6049081823
|
||||
248 FTL_Program_Page_Count -O--CK 100 100 000 - 3809010569
|
||||
180 Unused_Reserve_NAND_Blk PO--CK 000 000 000 - 1253
|
||||
210 Success_RAIN_Recov_Cnt -O--CK 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 51 Comprehensive SMART error log
|
||||
0x03 GPL R/O 16383 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x13 GPL R/O 1 SATA NCQ Send and Receive log
|
||||
0x24 GPL R/O 8000 Current Device Internal Status Data log
|
||||
0x25 GPL R/O 8000 Saved Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa0 GPL VS 35328 Device vendor specific log
|
||||
0xa1 GPL,SL VS 3 Device vendor specific log
|
||||
0xa2 GPL,SL VS 1 Device vendor specific log
|
||||
0xa3 GPL VS 13824 Device vendor specific log
|
||||
0xa4 GPL VS 354 Device vendor specific log
|
||||
0xa4 SL VS 98 Device vendor specific log
|
||||
0xa5 GPL VS 8000 Device vendor specific log
|
||||
0xa5 SL VS 64 Device vendor specific log
|
||||
0xa6 GPL VS 8000 Device vendor specific log
|
||||
0xa6 SL VS 64 Device vendor specific log
|
||||
0xa7-0xdf GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (16383 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Vendor (0xff) Completed without error 00% 41373 -
|
||||
# 2 Vendor (0xff) Completed without error 00% 41296 -
|
||||
# 3 Vendor (0xff) Completed without error 00% 41213 -
|
||||
# 4 Vendor (0xff) Completed without error 00% 41101 -
|
||||
# 5 Vendor (0xff) Completed without error 00% 40981 -
|
||||
# 6 Vendor (0xff) Completed without error 00% 40861 -
|
||||
# 7 Vendor (0xff) Completed without error 00% 40741 -
|
||||
# 8 Vendor (0xff) Completed without error 00% 40621 -
|
||||
# 9 Vendor (0xff) Completed without error 00% 40501 -
|
||||
#10 Vendor (0xff) Completed without error 00% 40381 -
|
||||
#11 Vendor (0xff) Completed without error 00% 40261 -
|
||||
#12 Vendor (0xff) Completed without error 00% 40141 -
|
||||
#13 Vendor (0xff) Completed without error 00% 40021 -
|
||||
#14 Vendor (0xff) Completed without error 00% 39901 -
|
||||
#15 Vendor (0xff) Completed without error 00% 39781 -
|
||||
#16 Vendor (0xff) Completed without error 00% 39661 -
|
||||
#17 Vendor (0xff) Completed without error 00% 39541 -
|
||||
#18 Vendor (0xff) Completed without error 00% 39421 -
|
||||
#19 Vendor (0xff) Completed without error 00% 39301 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: SMART Off-line Data Collection executing in background (4)
|
||||
Current Temperature: 52 Celsius
|
||||
Power Cycle Min/Max Temperature: 38/55 Celsius
|
||||
Lifetime Min/Max Temperature: 19/68 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (305)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 54 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 41374 --- Power-on Hours
|
||||
0x01 0x018 6 192368826458 --- Logical Sectors Written
|
||||
0x01 0x020 6 2468535587 --- Number of Write Commands
|
||||
0x01 0x028 6 714893892040 --- Logical Sectors Read
|
||||
0x01 0x030 6 12281303279 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 65 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 52 --- Current Temperature
|
||||
0x05 0x010 1 45 --- Average Short Term Temperature
|
||||
0x05 0x018 1 32 --- Average Long Term Temperature
|
||||
0x05 0x020 1 68 --- Highest Temperature
|
||||
0x05 0x028 1 19 --- Lowest Temperature
|
||||
0x05 0x030 1 58 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 29 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 32 --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 32 --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 368 --- Number of Hardware Resets
|
||||
0x06 0x010 4 110 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 47 N-- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x000a 4 42 Device-to-host register FISes sent due to a COMRESET
|
||||
|
229
SSD/Crucial/CT275/CT275MX300SSD1/655550D3D3F1
Normal file
229
SSD/Crucial/CT275/CT275MX300SSD1/655550D3D3F1
Normal file
@@ -0,0 +1,229 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p2 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Crucial/Micron Client SSDs
|
||||
Device Model: Crucial_CT275MX300SSD1
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 00a075 ...
|
||||
Firmware Version: M0CR040
|
||||
User Capacity: 275,064,201,216 bytes [275 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
Form Factor: 2.5 inches
|
||||
TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Fri Oct 28 01:12:13 2022 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 254 (maximum performance)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 728) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 5) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 3) minutes.
|
||||
SCT capabilities: (0x0035) SCT Status supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 000 - 20
|
||||
5 Reallocate_NAND_Blk_Cnt -O--CK 099 099 010 - 20
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 537
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 411
|
||||
171 Program_Fail_Count -O--CK 100 100 000 - 2
|
||||
172 Erase_Fail_Count -O--CK 100 100 000 - 0
|
||||
173 Ave_Block-Erase_Count -O--CK 099 099 000 - 22
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 96
|
||||
183 SATA_Interfac_Downshift -O--CK 100 100 000 - 0
|
||||
184 Error_Correction_Count -O--CK 100 100 000 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 1113
|
||||
194 Temperature_Celsius -O---K 065 055 000 - 35 (Min/Max 14/45)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 20
|
||||
197 Current_Pending_ECC_Cnt -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0
|
||||
202 Percent_Lifetime_Remain ----CK 099 099 001 - 1
|
||||
206 Write_Error_Rate -OSR-- 100 100 000 - 2
|
||||
246 Total_LBAs_Written -O--CK 100 100 000 - 6347834465
|
||||
247 Host_Program_Page_Count -O--CK 100 100 000 - 198946649
|
||||
248 FTL_Program_Page_Count -O--CK 100 100 000 - 98202768
|
||||
180 Unused_Reserve_NAND_Blk PO--CK 000 000 000 - 1236
|
||||
210 Success_RAIN_Recov_Cnt -O--CK 100 100 000 - 78
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 51 Comprehensive SMART error log
|
||||
0x03 GPL R/O 16383 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x13 GPL R/O 1 SATA NCQ Send and Receive log
|
||||
0x24 GPL R/O 8000 Current Device Internal Status Data log
|
||||
0x25 GPL R/O 8000 Saved Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa0 GPL VS 35328 Device vendor specific log
|
||||
0xa1 GPL,SL VS 3 Device vendor specific log
|
||||
0xa2 GPL,SL VS 1 Device vendor specific log
|
||||
0xa3 GPL VS 13824 Device vendor specific log
|
||||
0xa4 GPL VS 354 Device vendor specific log
|
||||
0xa4 SL VS 98 Device vendor specific log
|
||||
0xa5 GPL VS 8000 Device vendor specific log
|
||||
0xa5 SL VS 64 Device vendor specific log
|
||||
0xa6 GPL VS 8000 Device vendor specific log
|
||||
0xa6 SL VS 64 Device vendor specific log
|
||||
0xa7-0xdf GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (16383 sectors)
|
||||
Device Error Count: 1113
|
||||
CR = Command Register
|
||||
FEATR = Features Register
|
||||
COUNT = Count (was: Sector Count) Register
|
||||
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
|
||||
LH = LBA High (was: Cylinder High) Register ] LBA
|
||||
LM = LBA Mid (was: Cylinder Low) Register ] Register
|
||||
LL = LBA Low (was: Sector Number) Register ]
|
||||
DV = Device (was: Device/Head) Register
|
||||
DC = Device Control Register
|
||||
ER = Error register
|
||||
ST = Status register
|
||||
Powered_Up_Time is measured from power on, and printed as
|
||||
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
||||
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
||||
|
||||
Error 1113 [1112] log entry is empty
|
||||
Error 1112 [1111] log entry is empty
|
||||
Error 1111 [1110] log entry is empty
|
||||
Error 1110 [1109] log entry is empty
|
||||
Error 1109 [1108] log entry is empty
|
||||
Error 1108 [1107] log entry is empty
|
||||
Error 1107 [1106] log entry is empty
|
||||
Error 1106 [1105] log entry is empty
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Vendor (0xff) Completed without error 00% 524 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 35 Celsius
|
||||
Power Cycle Min/Max Temperature: 35/38 Celsius
|
||||
Lifetime Min/Max Temperature: 14/45 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (306)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 411 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 537 --- Power-on Hours
|
||||
0x01 0x018 6 6347834465 --- Logical Sectors Written
|
||||
0x01 0x020 6 67229073 --- Number of Write Commands
|
||||
0x01 0x028 6 11128033039 --- Logical Sectors Read
|
||||
0x01 0x030 6 128500338 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 1113 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 550 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 35 --- Current Temperature
|
||||
0x05 0x010 1 35 --- Average Short Term Temperature
|
||||
0x05 0x018 1 - --- Average Long Term Temperature
|
||||
0x05 0x020 1 45 --- Highest Temperature
|
||||
0x05 0x028 1 14 --- Lowest Temperature
|
||||
0x05 0x030 1 35 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 26 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 - --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 - --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 1977 --- Number of Hardware Resets
|
||||
0x06 0x010 4 709 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 1 N-- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x000a 4 3 Device-to-host register FISes sent due to a COMRESET
|
||||
|
208
SSD/Crucial/CT275/CT275MX300SSD1/A7D6843337EB
Normal file
208
SSD/Crucial/CT275/CT275MX300SSD1/A7D6843337EB
Normal file
@@ -0,0 +1,208 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Crucial/Micron Client SSDs
|
||||
Device Model: Crucial_CT275MX300SSD1
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 00a075 ...
|
||||
Firmware Version: M0CR060
|
||||
User Capacity: 275,064,201,216 bytes [275 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
Form Factor: 2.5 inches
|
||||
TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Mon Apr 25 14:29:24 2022 EDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Unavailable
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 728) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 5) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 3) minutes.
|
||||
SCT capabilities: (0x0035) SCT Status supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 000 - 0
|
||||
5 Reallocate_NAND_Blk_Cnt -O--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 287
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 410
|
||||
171 Program_Fail_Count -O--CK 100 100 000 - 0
|
||||
172 Erase_Fail_Count -O--CK 100 100 000 - 0
|
||||
173 Ave_Block-Erase_Count -O--CK 100 100 000 - 14
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 167
|
||||
183 SATA_Interfac_Downshift -O--CK 100 100 000 - 0
|
||||
184 Error_Correction_Count -O--CK 100 100 000 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
194 Temperature_Celsius -O---K 074 057 000 - 26 (Min/Max 22/43)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_ECC_Cnt -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0
|
||||
202 Percent_Lifetime_Remain ----CK 100 100 001 - 0
|
||||
206 Write_Error_Rate -OSR-- 100 100 000 - 0
|
||||
246 Total_LBAs_Written -O--CK 100 100 000 - 3943270954
|
||||
247 Host_Program_Page_Count -O--CK 100 100 000 - 123898627
|
||||
248 FTL_Program_Page_Count -O--CK 100 100 000 - 17075363
|
||||
180 Unused_Reserve_NAND_Blk PO--CK 000 000 000 - 1255
|
||||
210 Success_RAIN_Recov_Cnt -O--CK 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 51 Comprehensive SMART error log
|
||||
0x03 GPL R/O 16383 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x13 GPL R/O 1 SATA NCQ Send and Receive log
|
||||
0x24 GPL R/O 8000 Current Device Internal Status Data log
|
||||
0x25 GPL R/O 8000 Saved Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa0 GPL VS 35328 Device vendor specific log
|
||||
0xa1 GPL,SL VS 3 Device vendor specific log
|
||||
0xa2 GPL,SL VS 1 Device vendor specific log
|
||||
0xa3 GPL VS 13824 Device vendor specific log
|
||||
0xa4 GPL VS 354 Device vendor specific log
|
||||
0xa4 SL VS 98 Device vendor specific log
|
||||
0xa5 GPL VS 8000 Device vendor specific log
|
||||
0xa5 SL VS 64 Device vendor specific log
|
||||
0xa6 GPL VS 8000 Device vendor specific log
|
||||
0xa6 SL VS 64 Device vendor specific log
|
||||
0xa7-0xdf GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (16383 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Vendor (0xff) Completed without error 00% 196 -
|
||||
# 2 Vendor (0xff) Completed without error 00% 121 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 26 Celsius
|
||||
Power Cycle Min/Max Temperature: 23/26 Celsius
|
||||
Lifetime Min/Max Temperature: 22/43 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (417)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 410 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 287 --- Power-on Hours
|
||||
0x01 0x018 6 3943270954 --- Logical Sectors Written
|
||||
0x01 0x020 6 49983944 --- Number of Write Commands
|
||||
0x01 0x028 6 2422131447 --- Logical Sectors Read
|
||||
0x01 0x030 6 35737300 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 389 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 26 --- Current Temperature
|
||||
0x05 0x010 1 36 --- Average Short Term Temperature
|
||||
0x05 0x018 1 - --- Average Long Term Temperature
|
||||
0x05 0x020 1 43 --- Highest Temperature
|
||||
0x05 0x028 1 22 --- Lowest Temperature
|
||||
0x05 0x030 1 36 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 32 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 - --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 - --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 1616 --- Number of Hardware Resets
|
||||
0x06 0x010 4 295 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 0 N-- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x000a 4 3 Device-to-host register FISes sent due to a COMRESET
|
||||
|
217
SSD/Crucial/CT275/CT275MX300SSD1/F3286459AB2E
Normal file
217
SSD/Crucial/CT275/CT275MX300SSD1/F3286459AB2E
Normal file
@@ -0,0 +1,217 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Crucial/Micron Client SSDs
|
||||
Device Model: Crucial_CT275MX300SSD1
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 00a075 ...
|
||||
Firmware Version: M0CR060
|
||||
User Capacity: 275,064,201,216 bytes [275 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
Form Factor: 2.5 inches
|
||||
TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sun Jun 19 21:10:36 2022 EDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Unavailable
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 728) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 5) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 3) minutes.
|
||||
SCT capabilities: (0x0035) SCT Status supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 000 - 0
|
||||
5 Reallocate_NAND_Blk_Cnt -O--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 7964
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 2162
|
||||
171 Program_Fail_Count -O--CK 100 100 000 - 0
|
||||
172 Erase_Fail_Count -O--CK 100 100 000 - 0
|
||||
173 Ave_Block-Erase_Count -O--CK 086 086 000 - 217
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 376
|
||||
183 SATA_Interfac_Downshift -O--CK 100 100 000 - 0
|
||||
184 Error_Correction_Count -O--CK 100 100 000 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
194 Temperature_Celsius -O---K 065 037 000 - 35 (Min/Max 8/63)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_ECC_Cnt -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 53
|
||||
202 Percent_Lifetime_Remain ----CK 086 086 001 - 14
|
||||
206 Write_Error_Rate -OSR-- 100 100 000 - 0
|
||||
246 Total_LBAs_Written -O--CK 100 100 000 - 55373421207
|
||||
247 Host_Program_Page_Count -O--CK 100 100 000 - 1735816231
|
||||
248 FTL_Program_Page_Count -O--CK 100 100 000 - 799969657
|
||||
180 Unused_Reserve_NAND_Blk PO--CK 000 000 000 - 1251
|
||||
210 Success_RAIN_Recov_Cnt -O--CK 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 51 Comprehensive SMART error log
|
||||
0x03 GPL R/O 16383 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x13 GPL R/O 1 SATA NCQ Send and Receive log
|
||||
0x24 GPL R/O 8000 Current Device Internal Status Data log
|
||||
0x25 GPL R/O 8000 Saved Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa0 GPL VS 35328 Device vendor specific log
|
||||
0xa1 GPL,SL VS 3 Device vendor specific log
|
||||
0xa2 GPL,SL VS 1 Device vendor specific log
|
||||
0xa3 GPL VS 13824 Device vendor specific log
|
||||
0xa4 GPL VS 354 Device vendor specific log
|
||||
0xa4 SL VS 98 Device vendor specific log
|
||||
0xa5 GPL VS 8000 Device vendor specific log
|
||||
0xa5 SL VS 64 Device vendor specific log
|
||||
0xa6 GPL VS 8000 Device vendor specific log
|
||||
0xa6 SL VS 64 Device vendor specific log
|
||||
0xa7-0xdf GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (16383 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Vendor (0xff) Completed without error 00% 3250 -
|
||||
# 2 Vendor (0xff) Completed without error 00% 3200 -
|
||||
# 3 Vendor (0xff) Completed without error 00% 2023 -
|
||||
# 4 Vendor (0xff) Completed without error 00% 832 -
|
||||
# 5 Vendor (0xff) Completed without error 00% 532 -
|
||||
# 6 Vendor (0xff) Completed without error 00% 381 -
|
||||
# 7 Vendor (0xff) Completed without error 00% 276 -
|
||||
# 8 Vendor (0xff) Completed without error 00% 248 -
|
||||
# 9 Vendor (0xff) Completed without error 00% 193 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 35 Celsius
|
||||
Power Cycle Min/Max Temperature: 35/38 Celsius
|
||||
Lifetime Min/Max Temperature: 8/63 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (73)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 2162 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 7964 --- Power-on Hours
|
||||
0x01 0x018 6 55373421207 --- Logical Sectors Written
|
||||
0x01 0x020 6 651871745 --- Number of Write Commands
|
||||
0x01 0x028 6 71533408397 --- Logical Sectors Read
|
||||
0x01 0x030 6 1398521309 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 5763 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 35 --- Current Temperature
|
||||
0x05 0x010 1 34 --- Average Short Term Temperature
|
||||
0x05 0x018 1 32 --- Average Long Term Temperature
|
||||
0x05 0x020 1 63 --- Highest Temperature
|
||||
0x05 0x028 1 8 --- Lowest Temperature
|
||||
0x05 0x030 1 49 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 21 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 47 --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 32 --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 22487 --- Number of Hardware Resets
|
||||
0x06 0x010 4 9351 --- Number of ASR Events
|
||||
0x06 0x018 4 53 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 14 N-- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x000a 4 42 Device-to-host register FISes sent due to a COMRESET
|
||||
|
||||
|
||||
|
225
SSD/Crucial/CT275/CT275MX300SSD4/ECFEB3989534
Normal file
225
SSD/Crucial/CT275/CT275MX300SSD4/ECFEB3989534
Normal file
@@ -0,0 +1,225 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p1 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Crucial/Micron Client SSDs
|
||||
Device Model: Crucial_CT275MX300SSD4
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 00a075 ...
|
||||
Firmware Version: M0CR031
|
||||
User Capacity: 275,064,201,216 bytes [275 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
Form Factor: < 1.8 inches
|
||||
TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Mon Aug 22 18:43:06 2022 BST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 254 (maximum performance)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 934) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 5) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 3) minutes.
|
||||
SCT capabilities: (0x0035) SCT Status supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 000 - 0
|
||||
5 Reallocate_NAND_Blk_Cnt -O--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 11695
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 106
|
||||
171 Program_Fail_Count -O--CK 100 100 000 - 0
|
||||
172 Erase_Fail_Count -O--CK 100 100 000 - 0
|
||||
173 Ave_Block-Erase_Count -O--CK 099 099 000 - 26
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 97
|
||||
183 SATA_Interfac_Downshift -O--CK 100 100 000 - 0
|
||||
184 Error_Correction_Count -O--CK 100 100 000 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
194 Temperature_Celsius -O---K 041 026 000 - 59 (Min/Max 16/74)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_ECC_Cnt -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0
|
||||
202 Percent_Lifetime_Remain ----CK 099 099 001 - 1
|
||||
206 Write_Error_Rate -OSR-- 100 100 000 - 0
|
||||
246 Total_LBAs_Written -O--CK 100 100 000 - 6035805425
|
||||
247 Host_Program_Page_Count -O--CK 100 100 000 - 188619003
|
||||
248 FTL_Program_Page_Count -O--CK 100 100 000 - 78289626
|
||||
180 Unused_Reserve_NAND_Blk PO--CK 000 000 000 - 1247
|
||||
210 Success_RAIN_Recov_Cnt -O--CK 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 51 Comprehensive SMART error log
|
||||
0x03 GPL R/O 16383 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x13 GPL R/O 1 SATA NCQ Send and Receive log
|
||||
0x24 GPL R/O 8000 Current Device Internal Status Data log
|
||||
0x25 GPL R/O 8000 Saved Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa0 GPL VS 35328 Device vendor specific log
|
||||
0xa1 GPL,SL VS 3 Device vendor specific log
|
||||
0xa2 GPL,SL VS 1 Device vendor specific log
|
||||
0xa3 GPL VS 13824 Device vendor specific log
|
||||
0xa4 GPL VS 354 Device vendor specific log
|
||||
0xa4 SL VS 98 Device vendor specific log
|
||||
0xa5 GPL VS 8000 Device vendor specific log
|
||||
0xa5 SL VS 64 Device vendor specific log
|
||||
0xa6 GPL VS 8000 Device vendor specific log
|
||||
0xa6 SL VS 64 Device vendor specific log
|
||||
0xa7-0xdf GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (16383 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Vendor (0xff) Completed without error 00% 11644 -
|
||||
# 2 Vendor (0xff) Completed without error 00% 11500 -
|
||||
# 3 Vendor (0xff) Completed without error 00% 11354 -
|
||||
# 4 Vendor (0xff) Completed without error 00% 11212 -
|
||||
# 5 Vendor (0xff) Completed without error 00% 11065 -
|
||||
# 6 Vendor (0xff) Completed without error 00% 10921 -
|
||||
# 7 Vendor (0xff) Completed without error 00% 10777 -
|
||||
# 8 Vendor (0xff) Completed without error 00% 10636 -
|
||||
# 9 Vendor (0xff) Completed without error 00% 10491 -
|
||||
#10 Vendor (0xff) Completed without error 00% 10364 -
|
||||
#11 Vendor (0xff) Completed without error 00% 10220 -
|
||||
#12 Vendor (0xff) Completed without error 00% 10051 -
|
||||
#13 Vendor (0xff) Completed without error 00% 9870 -
|
||||
#14 Vendor (0xff) Completed without error 00% 9701 -
|
||||
#15 Vendor (0xff) Completed without error 00% 9556 -
|
||||
#16 Vendor (0xff) Completed without error 00% 9408 -
|
||||
#17 Vendor (0xff) Completed without error 00% 9268 -
|
||||
#18 Vendor (0xff) Completed without error 00% 9124 -
|
||||
#19 Vendor (0xff) Completed without error 00% 8986 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Completed [00% left] (4030-69565)
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 59 Celsius
|
||||
Power Cycle Min/Max Temperature: 39/74 Celsius
|
||||
Lifetime Min/Max Temperature: 16/74 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (275)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 106 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 11695 --- Power-on Hours
|
||||
0x01 0x018 6 6035805425 --- Logical Sectors Written
|
||||
0x01 0x020 6 64882611 --- Number of Write Commands
|
||||
0x01 0x028 6 515387567 --- Logical Sectors Read
|
||||
0x01 0x030 6 3190926 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 105 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 59 --- Current Temperature
|
||||
0x05 0x010 1 45 --- Average Short Term Temperature
|
||||
0x05 0x018 1 - --- Average Long Term Temperature
|
||||
0x05 0x020 1 74 --- Highest Temperature
|
||||
0x05 0x028 1 16 --- Lowest Temperature
|
||||
0x05 0x030 1 45 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 38 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 - --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 - --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 4046 --- Number of Hardware Resets
|
||||
0x06 0x010 4 62 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 1 N-- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x000a 4 108 Device-to-host register FISes sent due to a COMRESET
|
||||
|
Reference in New Issue