smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RELEASE amd64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Crucial/Micron Client SSDs
Device Model: Micron 1100 SATA 256GB
Serial Number: --
LU WWN Device Id: 5 00a075 ...
Firmware Version: M0DL022
User Capacity: 256,060,514,304 bytes [256 GB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: Solid State Device
Form Factor: M.2
TRIM Command: Available, deterministic, zeroed
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-3 T13/2161-D revision 5
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Wed May 11 12:38:50 2022 EDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
See vendor-specific Attribute list for marginal Attributes.
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 678) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 4) minutes.
Conveyance self-test routine
recommended polling time: ( 3) minutes.
SCT capabilities: (0x0035) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocate_NAND_Blk_Cnt PO--CK 100 100 010 - 0
9 Power_On_Hours -O--CK 100 100 000 - 1225
12 Power_Cycle_Count PO--CK 100 100 001 - 2130
181 Program_Fail_Cnt_Total PO--CK 100 100 001 - 0
182 Erase_Fail_Count_Total PO--CK 100 100 001 - 0
177 Wear_Leveling_Count PO--CK 100 100 010 - 11
187 Reported_Uncorrect PO--CK 100 100 001 - 0
194 Temperature_Celsius -O---K 065 042 000 - 35 (Min/Max 5/58)
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0
238 Unknown_Attribute ----CK 100 100 000 - 0
175 Program_Fail_Count_Chip PO--CK 100 100 000 - 0
176 Erase_Fail_Count_Chip PO--CK 100 100 000 - 0
178 Used_Rsvd_Blk_Cnt_Chip PO--CK 100 100 000 - 0
180 Unused_Reserve_NAND_Blk PO--CK 000 000 000 - 2049
195 Cumulativ_Corrected_ECC POSR-K 100 000 050 Past 0
241 Total_LBAs_Written PO--CK 100 100 000 - 3561985907
242 Total_LBAs_Read PO--CK 100 100 000 - 1056837157
179 Used_Rsvd_Blk_Cnt_Tot PO--CK 100 100 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 51 Comprehensive SMART error log
0x03 GPL R/O 16383 Ext. Comprehensive SMART error log
0x04 GPL,SL R/O 8 Device Statistics log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x13 GPL R/O 1 SATA NCQ Send and Receive log
0x24 GPL R/O 8000 Current Device Internal Status Data log
0x25 GPL R/O 8000 Saved Device Internal Status Data log
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0 GPL VS 35328 Device vendor specific log
0xa1 GPL,SL VS 3 Device vendor specific log
0xa2 GPL,SL VS 1 Device vendor specific log
0xa3 GPL VS 13824 Device vendor specific log
0xa4 GPL VS 354 Device vendor specific log
0xa4 SL VS 98 Device vendor specific log
0xa5 GPL VS 8000 Device vendor specific log
0xa5 SL VS 64 Device vendor specific log
0xa6 GPL VS 8000 Device vendor specific log
0xa6 SL VS 64 Device vendor specific log
0xa7-0xdf GPL,SL VS 1 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (16383 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Vendor (0xff) Completed without error 00% 204 -
# 2 Vendor (0xff) Completed without error 00% 156 -
# 3 Short offline Completed without error 00% 0 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 1 (0x0001)
Device State: Active (0)
Current Temperature: 35 Celsius
Power Cycle Min/Max Temperature: 26/35 Celsius
Lifetime Min/Max Temperature: 5/58 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: -5/75 Celsius
Temperature History Size (Index): 478 (465)
SCT Error Recovery Control command not supported
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 1) ==
0x01 0x008 4 2130 --- Lifetime Power-On Resets
0x01 0x010 4 1225 --- Power-on Hours
0x01 0x018 6 3561985907 --- Logical Sectors Written
0x01 0x020 6 16472294 --- Number of Write Commands
0x01 0x028 6 1056837157 --- Logical Sectors Read
0x01 0x030 6 9405162 --- Number of Read Commands
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 3546 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 35 --- Current Temperature
0x05 0x010 1 37 --- Average Short Term Temperature
0x05 0x018 1 - --- Average Long Term Temperature
0x05 0x020 1 58 --- Highest Temperature
0x05 0x028 1 5 --- Lowest Temperature
0x05 0x030 1 42 --- Highest Average Short Term Temperature
0x05 0x038 1 33 --- Lowest Average Short Term Temperature
0x05 0x040 1 - --- Highest Average Long Term Temperature
0x05 0x048 1 - --- Lowest Average Long Term Temperature
0x05 0x050 4 0 --- Time in Over-Temperature
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
0x05 0x060 4 0 --- Time in Under-Temperature
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 6030 --- Number of Hardware Resets
0x06 0x010 4 133 --- Number of ASR Events
0x06 0x018 4 0 --- Number of Interface CRC Errors
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
0x07 0x008 1 0 N-- Percentage Used Endurance Indicator
|||_ C monitored condition met
||__ D supports DSN
|___ N normalized value
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 4 0 Command failed due to ICRC error
0x000a 4 6 Device-to-host register FISes sent due to a COMRESET

View File

@@ -0,0 +1,371 @@
smartctl 7.2 2021-09-14 r5236 [FreeBSD 12.1-RELEASE-p22-HBSD amd64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Crucial/Micron Client SSDs
Device Model: Micron 1100 SATA 256GB
Serial Number: --
LU WWN Device Id: 5 00a075 ...
Firmware Version: M0DL003
User Capacity: 256,060,514,304 bytes [256 GB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: Solid State Device
Form Factor: M.2
TRIM Command: Available, deterministic, zeroed
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-3 T13/2161-D revision 5
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Wed Apr 13 18:56:59 2022 HKT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
See vendor-specific Attribute list for marginal Attributes.
General SMART Values:
Offline data collection status: (0x04) Offline data collection activity
was suspended by an interrupting command from host.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 425) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 4) minutes.
Conveyance self-test routine
recommended polling time: ( 3) minutes.
SCT capabilities: (0x0035) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocate_NAND_Blk_Cnt PO--CK 099 099 010 - 35
9 Power_On_Hours -O--CK 100 100 000 - 2427
12 Power_Cycle_Count PO--CK 100 100 001 - 2879
181 Program_Fail_Cnt_Total PO--CK 100 100 001 - 0
182 Erase_Fail_Count_Total PO--CK 100 100 001 - 0
177 Wear_Leveling_Count PO--CK 092 092 010 - 134
187 Reported_Uncorrect PO--CK 100 100 001 - 12174
194 Temperature_Celsius -O---K 046 038 000 - 54 (Min/Max 6/62)
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0
238 Unknown_Attribute ----CK 092 092 000 - 8
175 Program_Fail_Count_Chip PO--CK 100 100 000 - 0
176 Erase_Fail_Count_Chip PO--CK 100 100 000 - 0
178 Used_Rsvd_Blk_Cnt_Chip PO--CK 100 100 000 - 9
180 Unused_Reserve_NAND_Blk PO--CK 000 000 000 - 2014
195 Cumulativ_Corrected_ECC POSR-K 100 000 050 Past 0
241 Total_LBAs_Written PO--CK 100 100 000 - 30818117320
242 Total_LBAs_Read PO--CK 100 100 000 - 46013985142
179 Used_Rsvd_Blk_Cnt_Tot PO--CK 099 099 000 - 35
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 51 Comprehensive SMART error log
0x03 GPL R/O 16383 Ext. Comprehensive SMART error log
0x04 GPL,SL R/O 8 Device Statistics log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x13 GPL R/O 1 SATA NCQ Send and Receive log
0x24 GPL R/O 8000 Current Device Internal Status Data log
0x25 GPL R/O 8000 Saved Device Internal Status Data log
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0 GPL VS 35328 Device vendor specific log
0xa1 GPL,SL VS 3 Device vendor specific log
0xa2 GPL,SL VS 1 Device vendor specific log
0xa3 GPL VS 13824 Device vendor specific log
0xa4 GPL VS 354 Device vendor specific log
0xa4 SL VS 98 Device vendor specific log
0xa5 GPL VS 8000 Device vendor specific log
0xa5 SL VS 64 Device vendor specific log
0xa6 GPL VS 8000 Device vendor specific log
0xa6 SL VS 64 Device vendor specific log
0xa7-0xdf GPL,SL VS 1 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (16383 sectors)
Device Error Count: 12173
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 12173 [12172] occurred at disk power-on lifetime: 533 hours (22 days + 5 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 04 00 00 00 01 2a 46 e0 00 Error: UNC at LBA = 0x00012a46 = 76358
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
42 00 00 00 04 00 00 00 01 2a 46 e0 00 22d+05:20:00.000 READ VERIFY SECTOR(S) EXT
42 00 00 00 04 00 00 00 01 2a 46 e0 00 22d+05:20:00.000 READ VERIFY SECTOR(S) EXT
42 00 00 00 04 00 00 00 01 2a 46 e0 00 22d+05:20:00.000 READ VERIFY SECTOR(S) EXT
42 00 00 00 04 00 00 00 01 2a 46 e0 00 22d+05:20:00.000 READ VERIFY SECTOR(S) EXT
42 00 00 00 04 00 00 00 01 2a 46 e0 00 22d+05:20:00.000 READ VERIFY SECTOR(S) EXT
Error 12172 [12171] occurred at disk power-on lifetime: 533 hours (22 days + 5 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 03 00 00 00 01 2a 43 e0 00 Error: UNC at LBA = 0x00012a43 = 76355
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
42 00 00 00 03 00 00 00 01 2a 43 e0 00 22d+05:20:00.000 READ VERIFY SECTOR(S) EXT
42 00 00 00 03 00 00 00 01 2a 43 e0 00 22d+05:20:00.000 READ VERIFY SECTOR(S) EXT
42 00 00 00 03 00 00 00 01 2a 43 e0 00 22d+05:20:00.000 READ VERIFY SECTOR(S) EXT
42 00 00 00 03 00 00 00 01 2a 43 e0 00 22d+05:20:00.000 READ VERIFY SECTOR(S) EXT
42 00 00 00 03 00 00 00 01 2a 43 e0 00 22d+05:20:00.000 READ VERIFY SECTOR(S) EXT
Error 12171 [12170] occurred at disk power-on lifetime: 533 hours (22 days + 5 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 03 00 00 00 01 2a 40 e0 00 Error: UNC at LBA = 0x00012a40 = 76352
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
42 00 00 00 03 00 00 00 01 2a 40 e0 00 22d+05:20:00.000 READ VERIFY SECTOR(S) EXT
42 00 00 00 03 00 00 00 01 2a 40 e0 00 22d+05:20:00.000 READ VERIFY SECTOR(S) EXT
42 00 00 00 03 00 00 00 01 2a 40 e0 00 22d+05:20:00.000 READ VERIFY SECTOR(S) EXT
42 00 00 00 03 00 00 00 01 2a 40 e0 00 22d+05:20:00.000 READ VERIFY SECTOR(S) EXT
42 00 00 00 03 00 00 00 01 2a 40 e0 00 22d+05:20:00.000 READ VERIFY SECTOR(S) EXT
Error 12170 [12169] occurred at disk power-on lifetime: 533 hours (22 days + 5 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 03 00 00 00 01 2a 3d e0 00 Error: UNC at LBA = 0x00012a3d = 76349
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
42 00 00 00 03 00 00 00 01 2a 3d e0 00 22d+05:20:00.000 READ VERIFY SECTOR(S) EXT
42 00 00 00 03 00 00 00 01 2a 3d e0 00 22d+05:20:00.000 READ VERIFY SECTOR(S) EXT
42 00 00 00 03 00 00 00 01 2a 3d e0 00 22d+05:20:00.000 READ VERIFY SECTOR(S) EXT
42 00 00 00 03 00 00 00 01 2a 3d e0 00 22d+05:20:00.000 READ VERIFY SECTOR(S) EXT
42 00 00 00 03 00 00 00 01 2a 3d e0 00 22d+05:20:00.000 READ VERIFY SECTOR(S) EXT
Error 12169 [12168] occurred at disk power-on lifetime: 533 hours (22 days + 5 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 04 00 00 00 01 2a 39 e0 00 Error: UNC at LBA = 0x00012a39 = 76345
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
42 00 00 00 04 00 00 00 01 2a 39 e0 00 22d+05:20:00.000 READ VERIFY SECTOR(S) EXT
42 00 00 00 04 00 00 00 01 2a 39 e0 00 22d+05:20:00.000 READ VERIFY SECTOR(S) EXT
42 00 00 00 04 00 00 00 01 2a 39 e0 00 22d+05:20:00.000 READ VERIFY SECTOR(S) EXT
42 00 00 00 04 00 00 00 01 2a 39 e0 00 22d+05:20:00.000 READ VERIFY SECTOR(S) EXT
42 00 00 00 04 00 00 00 01 2a 39 e0 00 22d+05:20:00.000 READ VERIFY SECTOR(S) EXT
Error 12168 [12167] occurred at disk power-on lifetime: 533 hours (22 days + 5 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 03 00 00 00 01 2a 36 e0 00 Error: UNC at LBA = 0x00012a36 = 76342
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
42 00 00 00 03 00 00 00 01 2a 36 e0 00 22d+05:20:00.000 READ VERIFY SECTOR(S) EXT
42 00 00 00 03 00 00 00 01 2a 36 e0 00 22d+05:20:00.000 READ VERIFY SECTOR(S) EXT
42 00 00 00 03 00 00 00 01 2a 36 e0 00 22d+05:20:00.000 READ VERIFY SECTOR(S) EXT
42 00 00 00 03 00 00 00 01 2a 36 e0 00 22d+05:20:00.000 READ VERIFY SECTOR(S) EXT
42 00 00 00 03 00 00 00 01 2a 36 e0 00 22d+05:20:00.000 READ VERIFY SECTOR(S) EXT
Error 12167 [12166] occurred at disk power-on lifetime: 533 hours (22 days + 5 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 03 00 00 00 01 2a 33 e0 00 Error: UNC at LBA = 0x00012a33 = 76339
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
42 00 00 00 03 00 00 00 01 2a 33 e0 00 22d+05:20:00.000 READ VERIFY SECTOR(S) EXT
42 00 00 00 03 00 00 00 01 2a 33 e0 00 22d+05:20:00.000 READ VERIFY SECTOR(S) EXT
42 00 00 00 03 00 00 00 01 2a 33 e0 00 22d+05:20:00.000 READ VERIFY SECTOR(S) EXT
42 00 00 00 03 00 00 00 01 2a 33 e0 00 22d+05:20:00.000 READ VERIFY SECTOR(S) EXT
42 00 00 00 03 00 00 00 01 2a 33 e0 00 22d+05:20:00.000 READ VERIFY SECTOR(S) EXT
Error 12166 [12165] occurred at disk power-on lifetime: 533 hours (22 days + 5 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 03 00 00 00 01 2a 30 e0 00 Error: UNC at LBA = 0x00012a30 = 76336
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
42 00 00 00 03 00 00 00 01 2a 30 e0 00 22d+05:20:00.000 READ VERIFY SECTOR(S) EXT
42 00 00 00 03 00 00 00 01 2a 30 e0 00 22d+05:20:00.000 READ VERIFY SECTOR(S) EXT
42 00 00 00 03 00 00 00 01 2a 30 e0 00 22d+05:20:00.000 READ VERIFY SECTOR(S) EXT
42 00 00 00 03 00 00 00 01 2a 30 e0 00 22d+05:20:00.000 READ VERIFY SECTOR(S) EXT
42 00 00 00 03 00 00 00 01 2a 30 e0 00 22d+05:20:00.000 READ VERIFY SECTOR(S) EXT
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Vendor (0xff) Completed without error 00% 2426 -
# 2 Vendor (0xff) Completed without error 00% 2365 -
# 3 Vendor (0xff) Completed without error 00% 2227 -
# 4 Vendor (0xff) Completed without error 00% 2065 -
# 5 Vendor (0xff) Completed without error 00% 1917 -
# 6 Vendor (0xff) Completed without error 00% 1801 -
# 7 Vendor (0xff) Completed without error 00% 1738 -
# 8 Vendor (0xff) Completed without error 00% 1590 -
# 9 Vendor (0xff) Completed without error 00% 1432 -
#10 Extended offline Completed without error 00% 1276 -
#11 Vendor (0xff) Completed without error 00% 1269 -
#12 Vendor (0xff) Completed without error 00% 1099 -
#13 Extended offline Completed without error 00% 950 -
#14 Short offline Completed without error 00% 950 -
#15 Vendor (0xff) Completed without error 00% 929 -
#16 Vendor (0xff) Completed without error 00% 767 -
#17 Short offline Interrupted (host reset) 00% 535 -
#18 Short offline Aborted by host 00% 535 -
#19 Short offline Completed without error 00% 535 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 1 (0x0001)
Device State: SMART Off-line Data Collection executing in background (4)
Current Temperature: 54 Celsius
Power Cycle Min/Max Temperature: 33/62 Celsius
Lifetime Min/Max Temperature: 6/62 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: -5/75 Celsius
Temperature History Size (Index): 478 (452)
SCT Error Recovery Control command not supported
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 1) ==
0x01 0x008 4 2879 --- Lifetime Power-On Resets
0x01 0x010 4 2427 --- Power-on Hours
0x01 0x018 6 30818117320 --- Logical Sectors Written
0x01 0x020 6 475017319 --- Number of Write Commands
0x01 0x028 6 46013985142 --- Logical Sectors Read
0x01 0x030 6 625483146 --- Number of Read Commands
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 12174 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 2882 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 54 --- Current Temperature
0x05 0x010 1 46 --- Average Short Term Temperature
0x05 0x018 1 - --- Average Long Term Temperature
0x05 0x020 1 62 --- Highest Temperature
0x05 0x028 1 6 --- Lowest Temperature
0x05 0x030 1 46 --- Highest Average Short Term Temperature
0x05 0x038 1 32 --- Lowest Average Short Term Temperature
0x05 0x040 1 - --- Highest Average Long Term Temperature
0x05 0x048 1 - --- Lowest Average Long Term Temperature
0x05 0x050 4 0 --- Time in Over-Temperature
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
0x05 0x060 4 0 --- Time in Under-Temperature
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 9181 --- Number of Hardware Resets
0x06 0x010 4 64 --- Number of ASR Events
0x06 0x018 4 0 --- Number of Interface CRC Errors
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
0x07 0x008 1 8 N-- Percentage Used Endurance Indicator
|||_ C monitored condition met
||__ D supports DSN
|___ N normalized value
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 4 0 Command failed due to ICRC error
0x000a 4 3 Device-to-host register FISes sent due to a COMRESET

View File

@@ -0,0 +1,354 @@
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p5 amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Crucial/Micron Client SSDs
Device Model: Micron 1100 SATA 256GB
Serial Number: --
LU WWN Device Id: 5 00a075 ...
Firmware Version: M0DL003
User Capacity: 256,060,514,304 bytes [256 GB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: Solid State Device
Form Factor: M.2
TRIM Command: Available, deterministic, zeroed
Device is: In smartctl database 7.3/5319
ATA Version is: ACS-3 T13/2161-D revision 5
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Mon Dec 12 13:47:13 2022 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
See vendor-specific Attribute list for marginal Attributes.
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 678) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 4) minutes.
Conveyance self-test routine
recommended polling time: ( 3) minutes.
SCT capabilities: (0x0035) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocate_NAND_Blk_Cnt PO--CK 099 099 010 - 23
9 Power_On_Hours -O--CK 100 100 000 - 336
12 Power_Cycle_Count PO--CK 100 100 001 - 974
181 Program_Fail_Cnt_Total PO--CK 100 100 001 - 0
182 Erase_Fail_Count_Total PO--CK 100 100 001 - 0
177 Wear_Leveling_Count PO--CK 096 096 010 - 60
187 Reported_Uncorrect PO--CK 100 100 001 - 60
194 Temperature_Celsius -O---K 057 035 000 - 43 (Min/Max 9/65)
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0
238 Unknown_Attribute ----CK 096 096 000 - 4
175 Program_Fail_Count_Chip PO--CK 100 100 000 - 0
176 Erase_Fail_Count_Chip PO--CK 100 100 000 - 0
178 Used_Rsvd_Blk_Cnt_Chip PO--CK 100 100 000 - 7
180 Unused_Reserve_NAND_Blk PO--CK 000 000 000 - 2022
195 Cumulativ_Corrected_ECC POSR-K 100 000 050 Past 0
241 Total_LBAs_Written PO--CK 100 100 000 - 14996803171
242 Total_LBAs_Read PO--CK 100 100 000 - 10988590613
179 Used_Rsvd_Blk_Cnt_Tot PO--CK 099 099 000 - 23
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 51 Comprehensive SMART error log
0x03 GPL R/O 16383 Ext. Comprehensive SMART error log
0x04 GPL,SL R/O 8 Device Statistics log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x13 GPL R/O 1 SATA NCQ Send and Receive log
0x24 GPL R/O 8000 Current Device Internal Status Data log
0x25 GPL R/O 8000 Saved Device Internal Status Data log
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0 GPL VS 35328 Device vendor specific log
0xa1 GPL,SL VS 3 Device vendor specific log
0xa2 GPL,SL VS 1 Device vendor specific log
0xa3 GPL VS 13824 Device vendor specific log
0xa4 GPL VS 354 Device vendor specific log
0xa4 SL VS 98 Device vendor specific log
0xa5 GPL VS 8000 Device vendor specific log
0xa5 SL VS 64 Device vendor specific log
0xa6 GPL VS 8000 Device vendor specific log
0xa6 SL VS 64 Device vendor specific log
0xa7-0xdf GPL,SL VS 1 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (16383 sectors)
Device Error Count: 60
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 60 [59] occurred at disk power-on lifetime: 335 hours (13 days + 23 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 10 00 00 1d aa f0 80 40 08 Error: UNC at LBA = 0x1daaf080 = 497741952
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 00 00 10 00 00 1d aa f0 80 40 08 13d+23:37:00.000 READ FPDMA QUEUED
2f 00 00 00 01 00 00 00 00 00 10 e0 08 13d+23:37:00.000 READ LOG EXT
60 00 00 00 10 00 00 1d aa f0 80 40 08 13d+23:37:00.000 READ FPDMA QUEUED
2f 00 00 00 01 00 00 00 00 00 10 e0 08 13d+23:37:00.000 READ LOG EXT
60 00 00 00 10 00 00 1d aa f0 80 40 08 13d+23:37:00.000 READ FPDMA QUEUED
Error 59 [58] occurred at disk power-on lifetime: 335 hours (13 days + 23 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 10 00 00 1d aa f0 80 40 08 Error: UNC at LBA = 0x1daaf080 = 497741952
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 00 00 10 00 00 1d aa f0 80 40 08 13d+23:37:00.000 READ FPDMA QUEUED
2f 00 00 00 01 00 00 00 00 00 10 e0 08 13d+23:37:00.000 READ LOG EXT
60 00 00 00 10 00 00 1d aa f0 80 40 08 13d+23:37:00.000 READ FPDMA QUEUED
2f 00 00 00 01 00 00 00 00 00 10 e0 08 13d+23:37:00.000 READ LOG EXT
60 00 00 00 10 00 00 1d aa f0 80 40 08 13d+23:37:00.000 READ FPDMA QUEUED
Error 58 [57] occurred at disk power-on lifetime: 335 hours (13 days + 23 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 10 00 00 1d aa f0 80 40 08 Error: UNC at LBA = 0x1daaf080 = 497741952
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 00 00 10 00 00 1d aa f0 80 40 08 13d+23:37:00.000 READ FPDMA QUEUED
2f 00 00 00 01 00 00 00 00 00 10 e0 08 13d+23:37:00.000 READ LOG EXT
60 00 00 00 10 00 00 1d aa f0 80 40 08 13d+23:37:00.000 READ FPDMA QUEUED
2f 00 00 00 01 00 00 00 00 00 10 e0 08 13d+23:37:00.000 READ LOG EXT
60 00 00 00 10 00 00 1d aa f0 80 40 08 13d+23:37:00.000 READ FPDMA QUEUED
Error 57 [56] occurred at disk power-on lifetime: 335 hours (13 days + 23 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 10 00 00 1d aa f0 80 40 08 Error: UNC at LBA = 0x1daaf080 = 497741952
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 00 00 10 00 00 1d aa f0 80 40 08 13d+23:37:00.000 READ FPDMA QUEUED
2f 00 00 00 01 00 00 00 00 00 10 e0 08 13d+23:37:00.000 READ LOG EXT
60 00 aa 00 10 00 00 1d aa f0 80 40 08 13d+23:37:00.000 READ FPDMA QUEUED
60 00 00 00 10 00 00 1d aa f2 00 40 08 13d+23:37:00.000 READ FPDMA QUEUED
60 00 10 00 10 00 00 1d aa f0 00 40 08 13d+23:37:00.000 READ FPDMA QUEUED
Error 56 [55] occurred at disk power-on lifetime: 335 hours (13 days + 23 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 10 00 00 1d aa f0 80 40 08 Error: UNC at LBA = 0x1daaf080 = 497741952
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 aa 00 10 00 00 1d aa f0 80 40 08 13d+23:37:00.000 READ FPDMA QUEUED
60 00 00 00 10 00 00 1d aa f2 00 40 08 13d+23:37:00.000 READ FPDMA QUEUED
60 00 10 00 10 00 00 1d aa f0 00 40 08 13d+23:37:00.000 READ FPDMA QUEUED
60 00 00 00 10 00 00 1d aa f0 10 40 08 13d+23:37:00.000 READ FPDMA QUEUED
2f 00 00 00 01 00 00 00 00 00 10 e0 08 13d+23:37:00.000 READ LOG EXT
Error 55 [54] occurred at disk power-on lifetime: 335 hours (13 days + 23 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 10 00 00 1d aa f0 80 40 08 Error: UNC at LBA = 0x1daaf080 = 497741952
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 00 00 10 00 00 1d aa f0 80 40 08 13d+23:37:00.000 READ FPDMA QUEUED
2f 00 00 00 01 00 00 00 00 00 10 e0 08 13d+23:37:00.000 READ LOG EXT
60 00 00 00 10 00 00 1d aa f0 80 40 08 13d+23:37:00.000 READ FPDMA QUEUED
2f 00 00 00 01 00 00 00 00 00 10 e0 08 13d+23:37:00.000 READ LOG EXT
60 00 00 00 10 00 00 1d aa f0 80 40 08 13d+23:37:00.000 READ FPDMA QUEUED
Error 54 [53] occurred at disk power-on lifetime: 335 hours (13 days + 23 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 10 00 00 1d aa f0 80 40 08 Error: UNC at LBA = 0x1daaf080 = 497741952
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 00 00 10 00 00 1d aa f0 80 40 08 13d+23:37:00.000 READ FPDMA QUEUED
2f 00 00 00 01 00 00 00 00 00 10 e0 08 13d+23:37:00.000 READ LOG EXT
60 00 00 00 10 00 00 1d aa f0 80 40 08 13d+23:37:00.000 READ FPDMA QUEUED
2f 00 00 00 01 00 00 00 00 00 10 e0 08 13d+23:37:00.000 READ LOG EXT
60 00 00 00 10 00 00 1d aa f0 80 40 08 13d+23:37:00.000 READ FPDMA QUEUED
Error 53 [52] occurred at disk power-on lifetime: 335 hours (13 days + 23 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 10 00 00 1d aa f0 80 40 08 Error: UNC at LBA = 0x1daaf080 = 497741952
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 00 00 10 00 00 1d aa f0 80 40 08 13d+23:37:00.000 READ FPDMA QUEUED
2f 00 00 00 01 00 00 00 00 00 10 e0 08 13d+23:37:00.000 READ LOG EXT
60 00 00 00 10 00 00 1d aa f0 80 40 08 13d+23:37:00.000 READ FPDMA QUEUED
2f 00 00 00 01 00 00 00 00 00 10 e0 08 13d+23:37:00.000 READ LOG EXT
60 00 00 00 10 00 00 1d aa f0 80 40 08 13d+23:37:00.000 READ FPDMA QUEUED
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Self-test routine in progress 90% 334 -
# 2 Short offline Completed without error 00% 0 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 1 (0x0001)
Device State: Active (0)
Current Temperature: 43 Celsius
Power Cycle Min/Max Temperature: 21/48 Celsius
Lifetime Min/Max Temperature: 9/65 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: -5/75 Celsius
Temperature History Size (Index): 478 (389)
SCT Error Recovery Control command not supported
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 1) ==
0x01 0x008 4 974 --- Lifetime Power-On Resets
0x01 0x010 4 336 --- Power-on Hours
0x01 0x018 6 14996803174 --- Logical Sectors Written
0x01 0x020 6 248170902 --- Number of Write Commands
0x01 0x028 6 10988590613 --- Logical Sectors Read
0x01 0x030 6 152618459 --- Number of Read Commands
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 60 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 976 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 43 --- Current Temperature
0x05 0x010 1 33 --- Average Short Term Temperature
0x05 0x018 1 - --- Average Long Term Temperature
0x05 0x020 1 65 --- Highest Temperature
0x05 0x028 1 9 --- Lowest Temperature
0x05 0x030 1 33 --- Highest Average Short Term Temperature
0x05 0x038 1 33 --- Lowest Average Short Term Temperature
0x05 0x040 1 - --- Highest Average Long Term Temperature
0x05 0x048 1 - --- Lowest Average Long Term Temperature
0x05 0x050 4 0 --- Time in Over-Temperature
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
0x05 0x060 4 0 --- Time in Under-Temperature
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 1913 --- Number of Hardware Resets
0x06 0x010 4 44 --- Number of ASR Events
0x06 0x018 4 0 --- Number of Interface CRC Errors
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
0x07 0x008 1 4 N-- Percentage Used Endurance Indicator
|||_ C monitored condition met
||__ D supports DSN
|___ N normalized value
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 4 0 Command failed due to ICRC error
0x000a 4 26 Device-to-host register FISes sent due to a COMRESET

View File

@@ -0,0 +1,224 @@
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.0-STABLE amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Crucial/Micron Client SSDs
Device Model: Micron_1100_MTFDDAK256TBN
Serial Number: --
LU WWN Device Id: 5 00a075 ...
Firmware Version: M0MA020
User Capacity: 256,060,514,304 bytes [256 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Form Factor: 2.5 inches
TRIM Command: Available, deterministic, zeroed
Device is: In smartctl database 7.3/5319
ATA Version is: ACS-3 T13/2161-D revision 5
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Mon Jul 11 17:18:37 2022 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 254 (maximum performance)
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x04) Offline data collection activity
was suspended by an interrupting command from host.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 104) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 4) minutes.
Conveyance self-test routine
recommended polling time: ( 3) minutes.
SCT capabilities: (0x0035) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 100 100 000 - 0
5 Reallocate_NAND_Blk_Cnt -O--CK 100 100 010 - 0
9 Power_On_Hours -O--CK 100 100 000 - 6222
12 Power_Cycle_Count -O--CK 100 100 000 - 1537
171 Program_Fail_Count -O--CK 100 100 000 - 0
172 Erase_Fail_Count -O--CK 100 100 000 - 0
173 Ave_Block-Erase_Count -O--CK 092 092 000 - 125
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 61
183 SATA_Interfac_Downshift -O--CK 100 100 000 - 0
184 Error_Correction_Count -O--CK 100 100 000 - 0
187 Reported_Uncorrect -O--CK 100 100 000 - 0
194 Temperature_Celsius -O---K 059 048 000 - 41 (Min/Max 14/52)
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
197 Current_Pending_ECC_Cnt -O--CK 100 100 000 - 0
198 Offline_Uncorrectable ----CK 100 100 000 - 0
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0
202 Percent_Lifetime_Remain ----CK 092 092 001 - 8
206 Write_Error_Rate -OSR-- 100 100 000 - 0
246 Total_LBAs_Written -O--CK 100 100 000 - 24732563777
247 Host_Program_Page_Count -O--CK 100 100 000 - 778941209
248 FTL_Program_Page_Count -O--CK 100 100 000 - 497858781
180 Unused_Reserve_NAND_Blk PO--CK 000 000 000 - 2041
210 Success_RAIN_Recov_Cnt -O--CK 100 100 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 51 Comprehensive SMART error log
0x03 GPL R/O 16383 Ext. Comprehensive SMART error log
0x04 GPL,SL R/O 8 Device Statistics log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x13 GPL R/O 1 SATA NCQ Send and Receive log
0x24 GPL R/O 8000 Current Device Internal Status Data log
0x25 GPL R/O 8000 Saved Device Internal Status Data log
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0 GPL VS 35328 Device vendor specific log
0xa1 GPL,SL VS 3 Device vendor specific log
0xa2 GPL,SL VS 1 Device vendor specific log
0xa3 GPL VS 13824 Device vendor specific log
0xa4 GPL VS 354 Device vendor specific log
0xa4 SL VS 98 Device vendor specific log
0xa5 GPL VS 8000 Device vendor specific log
0xa5 SL VS 64 Device vendor specific log
0xa6 GPL VS 8000 Device vendor specific log
0xa6 SL VS 64 Device vendor specific log
0xa7-0xdf GPL,SL VS 1 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (16383 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Vendor (0xff) Completed without error 00% 5770 -
# 2 Vendor (0xff) Completed without error 00% 5694 -
# 3 Vendor (0xff) Completed without error 00% 5102 -
# 4 Vendor (0xff) Completed without error 00% 3952 -
# 5 Vendor (0xff) Completed without error 00% 3878 -
# 6 Vendor (0xff) Completed without error 00% 3579 -
# 7 Vendor (0xff) Completed without error 00% 3318 -
# 8 Vendor (0xff) Completed without error 00% 3061 -
# 9 Vendor (0xff) Completed without error 00% 2790 -
#10 Vendor (0xff) Completed without error 00% 2558 -
#11 Vendor (0xff) Completed without error 00% 2356 -
#12 Vendor (0xff) Completed without error 00% 2250 -
#13 Vendor (0xff) Completed without error 00% 2155 -
#14 Vendor (0xff) Completed without error 00% 1914 -
#15 Vendor (0xff) Completed without error 00% 1670 -
#16 Vendor (0xff) Completed without error 00% 1430 -
#17 Vendor (0xff) Completed without error 00% 1188 -
#18 Vendor (0xff) Completed without error 00% 952 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 1 (0x0001)
Device State: SMART Off-line Data Collection executing in background (4)
Current Temperature: 41 Celsius
Power Cycle Min/Max Temperature: 35/45 Celsius
Lifetime Min/Max Temperature: 14/52 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: -5/75 Celsius
Temperature History Size (Index): 478 (328)
SCT Error Recovery Control command not supported
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 1) ==
0x01 0x008 4 1537 --- Lifetime Power-On Resets
0x01 0x010 4 6222 --- Power-on Hours
0x01 0x018 6 24732563777 --- Logical Sectors Written
0x01 0x020 6 345817549 --- Number of Write Commands
0x01 0x028 6 12358584268 --- Logical Sectors Read
0x01 0x030 6 205376720 --- Number of Read Commands
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 1558 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 41 --- Current Temperature
0x05 0x010 1 38 --- Average Short Term Temperature
0x05 0x018 1 - --- Average Long Term Temperature
0x05 0x020 1 52 --- Highest Temperature
0x05 0x028 1 14 --- Lowest Temperature
0x05 0x030 1 38 --- Highest Average Short Term Temperature
0x05 0x038 1 27 --- Lowest Average Short Term Temperature
0x05 0x040 1 - --- Highest Average Long Term Temperature
0x05 0x048 1 - --- Lowest Average Long Term Temperature
0x05 0x050 4 0 --- Time in Over-Temperature
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
0x05 0x060 4 0 --- Time in Under-Temperature
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 4350 --- Number of Hardware Resets
0x06 0x010 4 973 --- Number of ASR Events
0x06 0x018 4 0 --- Number of Interface CRC Errors
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
0x07 0x008 1 8 N-- Percentage Used Endurance Indicator
|||_ C monitored condition met
||__ D supports DSN
|___ N normalized value
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 4 0 Command failed due to ICRC error
0x000a 4 296 Device-to-host register FISes sent due to a COMRESET

View File

@@ -0,0 +1,215 @@
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Crucial/Micron Client SSDs
Device Model: Micron_1100_MTFDDAK512TBN
Serial Number: --
LU WWN Device Id: 5 00a075 ...
Firmware Version: M0MU031
User Capacity: 512,110,190,592 bytes [512 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Form Factor: 2.5 inches
TRIM Command: Available, deterministic, zeroed
Device is: In smartctl database 7.3/5319
ATA Version is: ACS-3 T13/2161-D revision 5
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Sat May 14 21:02:06 2022 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x03) Offline data collection activity
is in progress.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 198) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 6) minutes.
Conveyance self-test routine
recommended polling time: ( 3) minutes.
SCT capabilities: (0x0035) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 100 100 000 - 2
5 Reallocate_NAND_Blk_Cnt -O--CK 100 100 010 - 1
9 Power_On_Hours -O--CK 100 100 000 - 1300
12 Power_Cycle_Count -O--CK 100 100 000 - 6
171 Program_Fail_Count -O--CK 100 100 000 - 1
172 Erase_Fail_Count -O--CK 100 100 000 - 0
173 Ave_Block-Erase_Count -O--CK 085 085 000 - 229
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 2
183 SATA_Interfac_Downshift -O--CK 100 100 000 - 0
184 Error_Correction_Count -O--CK 100 100 000 - 0
187 Reported_Uncorrect -O--CK 100 100 000 - 0
194 Temperature_Celsius -O---K 067 054 000 - 33 (Min/Max 23/46)
196 Reallocated_Event_Count -O--CK 100 100 000 - 1
197 Current_Pending_ECC_Cnt -O--CK 100 100 000 - 0
198 Offline_Uncorrectable ----CK 100 100 000 - 0
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0
202 Percent_Lifetime_Remain ----CK 085 085 001 - 15
206 Write_Error_Rate -OSR-- 100 100 000 - 1
246 Total_LBAs_Written -O--CK 100 100 000 - 109143028606
247 Host_Program_Page_Count -O--CK 100 100 000 - 3410719905
248 FTL_Program_Page_Count -O--CK 100 100 000 - 4954797075
180 Unused_Reserve_NAND_Blk PO--CK 000 000 000 - 2452
210 Success_RAIN_Recov_Cnt -O--CK 100 100 000 - 4
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 51 Comprehensive SMART error log
0x03 GPL R/O 16383 Ext. Comprehensive SMART error log
0x04 GPL,SL R/O 8 Device Statistics log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x13 GPL R/O 1 SATA NCQ Send and Receive log
0x24 GPL R/O 8000 Current Device Internal Status Data log
0x25 GPL R/O 8000 Saved Device Internal Status Data log
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0 GPL VS 35328 Device vendor specific log
0xa1 GPL,SL VS 3 Device vendor specific log
0xa2 GPL,SL VS 1 Device vendor specific log
0xa3 GPL VS 13824 Device vendor specific log
0xa4 GPL VS 354 Device vendor specific log
0xa4 SL VS 98 Device vendor specific log
0xa5 GPL VS 8000 Device vendor specific log
0xa5 SL VS 64 Device vendor specific log
0xa6 GPL VS 8000 Device vendor specific log
0xa6 SL VS 64 Device vendor specific log
0xa7-0xdf GPL,SL VS 1 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (16383 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Vendor (0xff) Completed without error 00% 1299 -
# 2 Vendor (0xff) Completed without error 00% 1103 -
# 3 Vendor (0xff) Completed without error 00% 960 -
# 4 Vendor (0xff) Completed without error 00% 818 -
# 5 Vendor (0xff) Completed without error 00% 661 -
# 6 Extended offline Completed without error 00% 545 -
# 7 Extended offline Completed without error 00% 532 -
# 8 Vendor (0xff) Completed without error 00% 439 -
# 9 Vendor (0xff) Completed without error 00% 195 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 1 (0x0001)
Device State: SMART Off-line Data Collection executing in background (4)
Current Temperature: 33 Celsius
Power Cycle Min/Max Temperature: 23/40 Celsius
Lifetime Min/Max Temperature: 23/46 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: -5/75 Celsius
Temperature History Size (Index): 478 (318)
SCT Error Recovery Control command not supported
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 1) ==
0x01 0x008 4 6 --- Lifetime Power-On Resets
0x01 0x010 4 1300 --- Power-on Hours
0x01 0x018 6 109143028606 --- Logical Sectors Written
0x01 0x020 6 190976231 --- Number of Write Commands
0x01 0x028 6 80600917668 --- Logical Sectors Read
0x01 0x030 6 156903548 --- Number of Read Commands
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 11 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 33 --- Current Temperature
0x05 0x010 1 32 --- Average Short Term Temperature
0x05 0x018 1 - --- Average Long Term Temperature
0x05 0x020 1 46 --- Highest Temperature
0x05 0x028 1 23 --- Lowest Temperature
0x05 0x030 1 34 --- Highest Average Short Term Temperature
0x05 0x038 1 32 --- Lowest Average Short Term Temperature
0x05 0x040 1 - --- Highest Average Long Term Temperature
0x05 0x048 1 - --- Lowest Average Long Term Temperature
0x05 0x050 4 0 --- Time in Over-Temperature
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
0x05 0x060 4 0 --- Time in Under-Temperature
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 331 --- Number of Hardware Resets
0x06 0x010 4 106 --- Number of ASR Events
0x06 0x018 4 0 --- Number of Interface CRC Errors
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
0x07 0x008 1 15 N-- Percentage Used Endurance Indicator
|||_ C monitored condition met
||__ D supports DSN
|___ N normalized value
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 4 0 Command failed due to ICRC error
0x000a 4 285 Device-to-host register FISes sent due to a COMRESET

View File

@@ -0,0 +1,227 @@
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Crucial/Micron Client SSDs
Device Model: Micron_1100_MTFDDAK512TBN
Serial Number: --
LU WWN Device Id: 5 00a075 ...
Firmware Version: M0MU031
User Capacity: 512,110,190,592 bytes [512 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Form Factor: 2.5 inches
TRIM Command: Available, deterministic, zeroed
Device is: In smartctl database 7.3/5319
ATA Version is: ACS-3 T13/2161-D revision 5
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Wed Jul 13 10:52:57 2022 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 1357) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 7) minutes.
Conveyance self-test routine
recommended polling time: ( 3) minutes.
SCT capabilities: (0x0035) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 100 100 000 - 2
5 Reallocate_NAND_Blk_Cnt -O--CK 100 100 010 - 1
9 Power_On_Hours -O--CK 100 100 000 - 40692
12 Power_Cycle_Count -O--CK 100 100 000 - 18
171 Program_Fail_Count -O--CK 100 100 000 - 1
172 Erase_Fail_Count -O--CK 100 100 000 - 0
173 Ave_Block-Erase_Count -O--CK 021 021 000 - 1190
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 7
183 SATA_Interfac_Downshift -O--CK 100 100 000 - 0
184 Error_Correction_Count -O--CK 100 100 000 - 0
187 Reported_Uncorrect -O--CK 100 100 000 - 0
194 Temperature_Celsius -O---K 066 044 000 - 34 (Min/Max 18/56)
196 Reallocated_Event_Count -O--CK 100 100 000 - 1
197 Current_Pending_ECC_Cnt -O--CK 100 100 000 - 0
198 Offline_Uncorrectable ----CK 100 100 000 - 0
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0
202 Percent_Lifetime_Remain ----CK 021 021 001 - 79
206 Write_Error_Rate -OSR-- 100 100 000 - 1
246 Total_LBAs_Written -O--CK 100 100 000 - 506397052595
247 Host_Program_Page_Count -O--CK 100 100 000 - 15938122746
248 FTL_Program_Page_Count -O--CK 100 100 000 - 99148140301
180 Unused_Reserve_NAND_Blk PO--CK 000 000 000 - 2467
210 Success_RAIN_Recov_Cnt -O--CK 100 100 000 - 4
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 51 Comprehensive SMART error log
0x03 GPL R/O 16383 Ext. Comprehensive SMART error log
0x04 GPL,SL R/O 8 Device Statistics log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x13 GPL R/O 1 SATA NCQ Send and Receive log
0x24 GPL R/O 8000 Current Device Internal Status Data log
0x25 GPL R/O 8000 Saved Device Internal Status Data log
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0 GPL VS 35328 Device vendor specific log
0xa1 GPL,SL VS 3 Device vendor specific log
0xa2 GPL,SL VS 1 Device vendor specific log
0xa3 GPL VS 13824 Device vendor specific log
0xa4 GPL VS 354 Device vendor specific log
0xa4 SL VS 98 Device vendor specific log
0xa5 GPL VS 8000 Device vendor specific log
0xa5 SL VS 64 Device vendor specific log
0xa6 GPL VS 8000 Device vendor specific log
0xa6 SL VS 64 Device vendor specific log
0xa7-0xdf GPL,SL VS 1 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (16383 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended offline Completed without error 00% 40691 -
# 2 Extended offline Completed without error 00% 40678 -
# 3 Vendor (0xff) Completed without error 00% 40678 -
# 4 Vendor (0xff) Completed without error 00% 40334 -
# 5 Extended offline Completed without error 00% 40216 -
# 6 Extended offline Completed without error 00% 40204 -
# 7 Vendor (0xff) Completed without error 00% 32797 -
# 8 Vendor (0xff) Completed without error 00% 32736 -
# 9 Vendor (0xff) Completed without error 00% 27920 -
#10 Vendor (0xff) Completed without error 00% 26827 -
#11 Vendor (0xff) Completed without error 00% 24329 -
#12 Vendor (0xff) Completed without error 00% 22077 -
#13 Vendor (0xff) Completed without error 00% 20750 -
#14 Vendor (0xff) Completed without error 00% 19509 -
#15 Vendor (0xff) Completed without error 00% 18245 -
#16 Vendor (0xff) Completed without error 00% 16952 -
#17 Vendor (0xff) Completed without error 00% 15354 -
#18 Vendor (0xff) Completed without error 00% 13939 -
#19 Vendor (0xff) Completed without error 00% 12324 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 1 (0x0001)
Device State: Active (0)
Current Temperature: 34 Celsius
Power Cycle Min/Max Temperature: 31/35 Celsius
Lifetime Min/Max Temperature: 18/56 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: -5/75 Celsius
Temperature History Size (Index): 478 (83)
SCT Error Recovery Control command not supported
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 1) ==
0x01 0x008 4 18 --- Lifetime Power-On Resets
0x01 0x010 4 40692 --- Power-on Hours
0x01 0x018 6 506397052595 --- Logical Sectors Written
0x01 0x020 6 11804301492 --- Number of Write Commands
0x01 0x028 6 478040337066 --- Logical Sectors Read
0x01 0x030 6 10435827862 --- Number of Read Commands
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 24 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 34 --- Current Temperature
0x05 0x010 1 29 --- Average Short Term Temperature
0x05 0x018 1 - --- Average Long Term Temperature
0x05 0x020 1 56 --- Highest Temperature
0x05 0x028 1 18 --- Lowest Temperature
0x05 0x030 1 33 --- Highest Average Short Term Temperature
0x05 0x038 1 24 --- Lowest Average Short Term Temperature
0x05 0x040 1 - --- Highest Average Long Term Temperature
0x05 0x048 1 - --- Lowest Average Long Term Temperature
0x05 0x050 4 0 --- Time in Over-Temperature
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
0x05 0x060 4 0 --- Time in Under-Temperature
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 169 --- Number of Hardware Resets
0x06 0x010 4 47 --- Number of ASR Events
0x06 0x018 4 0 --- Number of Interface CRC Errors
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
0x07 0x008 1 79 N-- Percentage Used Endurance Indicator
|||_ C monitored condition met
||__ D supports DSN
|___ N normalized value
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 4 0 Command failed due to ICRC error
0x000a 4 15 Device-to-host register FISes sent due to a COMRESET

View File

@@ -0,0 +1,225 @@
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Crucial/Micron Client SSDs
Device Model: Micron_1100_MTFDDAK512TBN
Serial Number: --
LU WWN Device Id: 5 00a075 ...
Firmware Version: M0MU031
User Capacity: 512,110,190,592 bytes [512 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Form Factor: 2.5 inches
TRIM Command: Available, deterministic, zeroed
Device is: In smartctl database 7.3/5319
ATA Version is: ACS-3 T13/2161-D revision 5
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Wed Jul 13 10:52:57 2022 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 1357) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 7) minutes.
Conveyance self-test routine
recommended polling time: ( 3) minutes.
SCT capabilities: (0x0035) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 100 100 000 - 0
5 Reallocate_NAND_Blk_Cnt -O--CK 100 100 010 - 0
9 Power_On_Hours -O--CK 100 100 000 - 40691
12 Power_Cycle_Count -O--CK 100 100 000 - 18
171 Program_Fail_Count -O--CK 100 100 000 - 0
172 Erase_Fail_Count -O--CK 100 100 000 - 0
173 Ave_Block-Erase_Count -O--CK 020 020 000 - 1213
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 7
183 SATA_Interfac_Downshift -O--CK 100 100 000 - 0
184 Error_Correction_Count -O--CK 100 100 000 - 0
187 Reported_Uncorrect -O--CK 100 100 000 - 0
194 Temperature_Celsius -O---K 066 045 000 - 34 (Min/Max 18/55)
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
197 Current_Pending_ECC_Cnt -O--CK 100 100 000 - 0
198 Offline_Uncorrectable ----CK 100 100 000 - 0
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0
202 Percent_Lifetime_Remain ----CK 020 020 001 - 80
206 Write_Error_Rate -OSR-- 100 100 000 - 0
246 Total_LBAs_Written -O--CK 100 100 000 - 506900081522
247 Host_Program_Page_Count -O--CK 100 100 000 - 15953842396
248 FTL_Program_Page_Count -O--CK 100 100 000 - 100239685800
180 Unused_Reserve_NAND_Blk PO--CK 000 000 000 - 2459
210 Success_RAIN_Recov_Cnt -O--CK 100 100 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 51 Comprehensive SMART error log
0x03 GPL R/O 16383 Ext. Comprehensive SMART error log
0x04 GPL,SL R/O 8 Device Statistics log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x13 GPL R/O 1 SATA NCQ Send and Receive log
0x24 GPL R/O 8000 Current Device Internal Status Data log
0x25 GPL R/O 8000 Saved Device Internal Status Data log
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0 GPL VS 35328 Device vendor specific log
0xa1 GPL,SL VS 3 Device vendor specific log
0xa2 GPL,SL VS 1 Device vendor specific log
0xa3 GPL VS 13824 Device vendor specific log
0xa4 GPL VS 354 Device vendor specific log
0xa4 SL VS 98 Device vendor specific log
0xa5 GPL VS 8000 Device vendor specific log
0xa5 SL VS 64 Device vendor specific log
0xa6 GPL VS 8000 Device vendor specific log
0xa6 SL VS 64 Device vendor specific log
0xa7-0xdf GPL,SL VS 1 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (16383 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended offline Completed without error 00% 40691 -
# 2 Extended offline Completed without error 00% 40678 -
# 3 Vendor (0xff) Completed without error 00% 40678 -
# 4 Vendor (0xff) Completed without error 00% 40333 -
# 5 Extended offline Completed without error 00% 40216 -
# 6 Extended offline Completed without error 00% 40204 -
# 7 Vendor (0xff) Completed without error 00% 32701 -
# 8 Vendor (0xff) Completed without error 00% 32619 -
# 9 Vendor (0xff) Completed without error 00% 27916 -
#10 Vendor (0xff) Completed without error 00% 26553 -
#11 Vendor (0xff) Completed without error 00% 23696 -
#12 Vendor (0xff) Completed without error 00% 21990 -
#13 Vendor (0xff) Completed without error 00% 20721 -
#14 Vendor (0xff) Completed without error 00% 19515 -
#15 Vendor (0xff) Completed without error 00% 18260 -
#16 Vendor (0xff) Completed without error 00% 16978 -
#17 Vendor (0xff) Completed without error 00% 15468 -
#18 Vendor (0xff) Completed without error 00% 14112 -
#19 Vendor (0xff) Completed without error 00% 12669 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 1 (0x0001)
Device State: Active (0)
Current Temperature: 34 Celsius
Power Cycle Min/Max Temperature: 31/34 Celsius
Lifetime Min/Max Temperature: 18/55 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: -5/75 Celsius
Temperature History Size (Index): 478 (372)
SCT Error Recovery Control command not supported
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 1) ==
0x01 0x008 4 18 --- Lifetime Power-On Resets
0x01 0x010 4 40691 --- Power-on Hours
0x01 0x018 6 506900081522 --- Logical Sectors Written
0x01 0x020 6 11790825275 --- Number of Write Commands
0x01 0x028 6 166244592064 --- Logical Sectors Read
0x01 0x030 6 3615106507 --- Number of Read Commands
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 26 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 34 --- Current Temperature
0x05 0x010 1 35 --- Average Short Term Temperature
0x05 0x018 1 - --- Average Long Term Temperature
0x05 0x020 1 55 --- Highest Temperature
0x05 0x028 1 18 --- Lowest Temperature
0x05 0x030 1 39 --- Highest Average Short Term Temperature
0x05 0x038 1 29 --- Lowest Average Short Term Temperature
0x05 0x040 1 - --- Highest Average Long Term Temperature
0x05 0x048 1 - --- Lowest Average Long Term Temperature
0x05 0x050 4 0 --- Time in Over-Temperature
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
0x05 0x060 4 0 --- Time in Under-Temperature
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 167 --- Number of Hardware Resets
0x06 0x010 4 47 --- Number of ASR Events
0x06 0x018 4 0 --- Number of Interface CRC Errors
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
0x07 0x008 1 80 N-- Percentage Used Endurance Indicator
|||_ C monitored condition met
||__ D supports DSN
|___ N normalized value
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 4 0 Command failed due to ICRC error
0x000a 4 15 Device-to-host register FISes sent due to a COMRESET

View File

@@ -0,0 +1,221 @@
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Crucial/Micron Client SSDs
Device Model: Micron_1100_MTFDDAK512TBN
Serial Number: --
LU WWN Device Id: 5 00a075 ...
Firmware Version: M0MU031
User Capacity: 512,110,190,592 bytes [512 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
Form Factor: 2.5 inches
TRIM Command: Available, deterministic, zeroed
Device is: In smartctl database 7.3/5319
ATA Version is: ACS-3 T13/2161-D revision 5
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Sat May 14 21:02:05 2022 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x03) Offline data collection activity
is in progress.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 202) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 6) minutes.
Conveyance self-test routine
recommended polling time: ( 3) minutes.
SCT capabilities: (0x0035) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 100 100 000 - 0
5 Reallocate_NAND_Blk_Cnt -O--CK 100 100 010 - 0
9 Power_On_Hours -O--CK 100 100 000 - 1422
12 Power_Cycle_Count -O--CK 100 100 000 - 9
171 Program_Fail_Count -O--CK 100 100 000 - 0
172 Erase_Fail_Count -O--CK 100 100 000 - 0
173 Ave_Block-Erase_Count -O--CK 085 085 000 - 228
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 5
183 SATA_Interfac_Downshift -O--CK 100 100 000 - 1
184 Error_Correction_Count -O--CK 100 100 000 - 0
187 Reported_Uncorrect -O--CK 100 100 000 - 0
194 Temperature_Celsius -O---K 064 050 000 - 36 (Min/Max 23/50)
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
197 Current_Pending_ECC_Cnt -O--CK 100 100 000 - 0
198 Offline_Uncorrectable ----CK 100 100 000 - 0
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0
202 Percent_Lifetime_Remain ----CK 085 085 001 - 15
206 Write_Error_Rate -OSR-- 100 100 000 - 0
246 Total_LBAs_Written -O--CK 100 100 000 - 109439248461
247 Host_Program_Page_Count -O--CK 100 100 000 - 3419976781
248 FTL_Program_Page_Count -O--CK 100 100 000 - 4933945684
180 Unused_Reserve_NAND_Blk PO--CK 000 000 000 - 2466
210 Success_RAIN_Recov_Cnt -O--CK 100 100 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 51 Comprehensive SMART error log
0x03 GPL R/O 16383 Ext. Comprehensive SMART error log
0x04 GPL,SL R/O 8 Device Statistics log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x13 GPL R/O 1 SATA NCQ Send and Receive log
0x24 GPL R/O 8000 Current Device Internal Status Data log
0x25 GPL R/O 8000 Saved Device Internal Status Data log
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0 GPL VS 35328 Device vendor specific log
0xa1 GPL,SL VS 3 Device vendor specific log
0xa2 GPL,SL VS 1 Device vendor specific log
0xa3 GPL VS 13824 Device vendor specific log
0xa4 GPL VS 354 Device vendor specific log
0xa4 SL VS 98 Device vendor specific log
0xa5 GPL VS 8000 Device vendor specific log
0xa5 SL VS 64 Device vendor specific log
0xa6 GPL VS 8000 Device vendor specific log
0xa6 SL VS 64 Device vendor specific log
0xa7-0xdf GPL,SL VS 1 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (16383 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Vendor (0xff) Completed without error 00% 1422 -
# 2 Vendor (0xff) Completed without error 00% 1227 -
# 3 Vendor (0xff) Completed without error 00% 1083 -
# 4 Vendor (0xff) Completed without error 00% 937 -
# 5 Vendor (0xff) Completed without error 00% 783 -
# 6 Extended offline Completed without error 00% 667 -
# 7 Extended offline Completed without error 00% 655 -
# 8 Vendor (0xff) Completed without error 00% 562 -
# 9 Vendor (0xff) Completed without error 00% 435 -
#10 Extended offline Completed without error 00% 107 -
#11 Short offline Completed without error 00% 103 -
#12 Vendor (0xff) Completed without error 00% 79 -
#13 Vendor (0xff) Completed without error 00% 26 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 1 (0x0001)
Device State: SMART Off-line Data Collection executing in background (4)
Current Temperature: 36 Celsius
Power Cycle Min/Max Temperature: 23/46 Celsius
Lifetime Min/Max Temperature: 23/50 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: -5/75 Celsius
Temperature History Size (Index): 478 (39)
SCT Error Recovery Control command not supported
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 1) ==
0x01 0x008 4 9 --- Lifetime Power-On Resets
0x01 0x010 4 1422 --- Power-on Hours
0x01 0x018 6 109439248461 --- Logical Sectors Written
0x01 0x020 6 193885926 --- Number of Write Commands
0x01 0x028 6 81264748347 --- Logical Sectors Read
0x01 0x030 6 156371387 --- Number of Read Commands
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 14 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 36 --- Current Temperature
0x05 0x010 1 28 --- Average Short Term Temperature
0x05 0x018 1 - --- Average Long Term Temperature
0x05 0x020 1 50 --- Highest Temperature
0x05 0x028 1 23 --- Lowest Temperature
0x05 0x030 1 37 --- Highest Average Short Term Temperature
0x05 0x038 1 28 --- Lowest Average Short Term Temperature
0x05 0x040 1 - --- Highest Average Long Term Temperature
0x05 0x048 1 - --- Lowest Average Long Term Temperature
0x05 0x050 4 0 --- Time in Over-Temperature
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
0x05 0x060 4 0 --- Time in Under-Temperature
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 368 --- Number of Hardware Resets
0x06 0x010 4 106 --- Number of ASR Events
0x06 0x018 4 0 --- Number of Interface CRC Errors
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
0x07 0x008 1 15 N-- Percentage Used Endurance Indicator
|||_ C monitored condition met
||__ D supports DSN
|___ N normalized value
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 4 0 Command failed due to ICRC error
0x000a 4 285 Device-to-host register FISes sent due to a COMRESET