mirror of
https://github.com/bsdhw/SMART.git
synced 2025-05-31 16:21:41 +05:30
Update of reports (new: 3633, modified: 0)
This commit is contained in:
234
SSD/Micron/1300/1300_MTFDDAK256TDL/0F2C03BBF8C8
Normal file
234
SSD/Micron/1300/1300_MTFDDAK256TDL/0F2C03BBF8C8
Normal file
@@ -0,0 +1,234 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.0-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Crucial/Micron Client SSDs
|
||||
Device Model: Micron_1300_MTFDDAK256TDL
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 00a075 ...
|
||||
Firmware Version: M5MU030
|
||||
User Capacity: 256,060,514,304 bytes [256 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
Form Factor: 2.5 inches
|
||||
TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
|
||||
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Wed Jun 1 06:51:14 2022 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 992) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 6) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 3) minutes.
|
||||
SCT capabilities: (0x0035) SCT Status supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 000 - 0
|
||||
5 Reallocate_NAND_Blk_Cnt -O--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 13639
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 78
|
||||
171 Program_Fail_Count -O--CK 100 100 000 - 0
|
||||
172 Erase_Fail_Count -O--CK 100 100 000 - 0
|
||||
173 Ave_Block-Erase_Count -O--CK 098 098 000 - 50
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 40
|
||||
183 SATA_Interfac_Downshift -O--CK 100 100 000 - 0
|
||||
184 Error_Correction_Count -O--CK 100 100 000 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
194 Temperature_Celsius -O---K 067 057 000 - 33 (Min/Max 17/43)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_ECC_Cnt -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0
|
||||
202 Percent_Lifetime_Remain ----CK 098 098 001 - 2
|
||||
206 Write_Error_Rate -OSR-- 100 100 000 - 0
|
||||
246 Total_LBAs_Written -O--CK 100 100 000 - 4582590471
|
||||
247 Host_Program_Page_Count -O--CK 100 100 000 - 144931212
|
||||
248 FTL_Program_Page_Count -O--CK 100 100 000 - 412029360
|
||||
180 Unused_Reserve_NAND_Blk PO--CK 000 000 000 - 308
|
||||
210 Success_RAIN_Recov_Cnt -O--CK 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 51 Comprehensive SMART error log
|
||||
0x03 GPL R/O 16383 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x13 GPL R/O 1 SATA NCQ Send and Receive log
|
||||
0x24 GPL R/O 8000 Current Device Internal Status Data log
|
||||
0x25 GPL R/O 8000 Saved Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa0 GPL VS 35328 Device vendor specific log
|
||||
0xa0 SL VS 255 Device vendor specific log
|
||||
0xa1 GPL,SL VS 4 Device vendor specific log
|
||||
0xa2 GPL,SL VS 1 Device vendor specific log
|
||||
0xa3 GPL VS 38400 Device vendor specific log
|
||||
0xa3 SL VS 255 Device vendor specific log
|
||||
0xa4 GPL VS 16477 Device vendor specific log
|
||||
0xa4 SL VS 255 Device vendor specific log
|
||||
0xa5 GPL VS 8000 Device vendor specific log
|
||||
0xa5 SL VS 255 Device vendor specific log
|
||||
0xa6 GPL VS 8000 Device vendor specific log
|
||||
0xa6 SL VS 255 Device vendor specific log
|
||||
0xa7 GPL VS 32768 Device vendor specific log
|
||||
0xa7 SL VS 255 Device vendor specific log
|
||||
0xa8-0xdf GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (16383 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Vendor (0xff) Completed without error 00% 13627 -
|
||||
# 2 Vendor (0xff) Completed without error 00% 13501 -
|
||||
# 3 Vendor (0xff) Completed without error 00% 13364 -
|
||||
# 4 Vendor (0xff) Completed without error 00% 13220 -
|
||||
# 5 Vendor (0xff) Completed without error 00% 13107 -
|
||||
# 6 Vendor (0xff) Completed without error 00% 12804 -
|
||||
# 7 Vendor (0xff) Completed without error 00% 12668 -
|
||||
# 8 Vendor (0xff) Completed without error 00% 12482 -
|
||||
# 9 Vendor (0xff) Completed without error 00% 12288 -
|
||||
#10 Vendor (0xff) Completed without error 00% 12058 -
|
||||
#11 Vendor (0xff) Completed without error 00% 11834 -
|
||||
#12 Short offline Completed without error 00% 11708 -
|
||||
#13 Vendor (0xff) Completed without error 00% 11629 -
|
||||
#14 Vendor (0xff) Completed without error 00% 11431 -
|
||||
#15 Vendor (0xff) Completed without error 00% 11267 -
|
||||
#16 Vendor (0xff) Completed without error 00% 11162 -
|
||||
#17 Short offline Completed without error 00% 10964 -
|
||||
#18 Vendor (0xff) Completed without error 00% 10917 -
|
||||
#19 Vendor (0xff) Completed without error 00% 10727 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Completed [00% left] (12615-78150)
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 33 Celsius
|
||||
Power Cycle Min/Max Temperature: 25/39 Celsius
|
||||
Lifetime Min/Max Temperature: 17/43 Celsius
|
||||
Specified Max Operating Temperature: 70 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
SMART Status: 0xc24f (PASSED)
|
||||
Minimum supported ERC Time Limit: 50 (5.0 seconds)
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -1/71 Celsius
|
||||
Temperature History Size (Index): 478 (49)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 3) ==
|
||||
0x01 0x008 4 78 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 13639 --- Power-on Hours
|
||||
0x01 0x018 6 4582590471 --- Logical Sectors Written
|
||||
0x01 0x020 6 137183005 --- Number of Write Commands
|
||||
0x01 0x028 6 2770832791 --- Logical Sectors Read
|
||||
0x01 0x030 6 44014501 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 108 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 33 --- Current Temperature
|
||||
0x05 0x010 1 36 --- Average Short Term Temperature
|
||||
0x05 0x018 1 34 --- Average Long Term Temperature
|
||||
0x05 0x020 1 43 --- Highest Temperature
|
||||
0x05 0x028 1 17 --- Lowest Temperature
|
||||
0x05 0x030 1 40 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 28 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 34 --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 31 --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 369 --- Number of Hardware Resets
|
||||
0x06 0x010 4 108 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 2 --- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x000a 4 9 Device-to-host register FISes sent due to a COMRESET
|
||||
|
||||
|
||||
|
234
SSD/Micron/1300/1300_MTFDDAK256TDL/618C693479A1
Normal file
234
SSD/Micron/1300/1300_MTFDDAK256TDL/618C693479A1
Normal file
@@ -0,0 +1,234 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.0-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Crucial/Micron Client SSDs
|
||||
Device Model: Micron_1300_MTFDDAK256TDL
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 00a075 ...
|
||||
Firmware Version: M5MU030
|
||||
User Capacity: 256,060,514,304 bytes [256 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
Form Factor: 2.5 inches
|
||||
TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
|
||||
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Wed Jun 1 06:51:14 2022 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 990) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 6) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 3) minutes.
|
||||
SCT capabilities: (0x0035) SCT Status supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 000 - 0
|
||||
5 Reallocate_NAND_Blk_Cnt -O--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 13641
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 78
|
||||
171 Program_Fail_Count -O--CK 100 100 000 - 0
|
||||
172 Erase_Fail_Count -O--CK 100 100 000 - 0
|
||||
173 Ave_Block-Erase_Count -O--CK 098 098 000 - 51
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 40
|
||||
183 SATA_Interfac_Downshift -O--CK 100 100 000 - 0
|
||||
184 Error_Correction_Count -O--CK 100 100 000 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
194 Temperature_Celsius -O---K 067 052 000 - 33 (Min/Max 16/48)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_ECC_Cnt -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0
|
||||
202 Percent_Lifetime_Remain ----CK 098 098 001 - 2
|
||||
206 Write_Error_Rate -OSR-- 100 100 000 - 0
|
||||
246 Total_LBAs_Written -O--CK 100 100 000 - 4533600302
|
||||
247 Host_Program_Page_Count -O--CK 100 100 000 - 143400212
|
||||
248 FTL_Program_Page_Count -O--CK 100 100 000 - 423075800
|
||||
180 Unused_Reserve_NAND_Blk PO--CK 000 000 000 - 308
|
||||
210 Success_RAIN_Recov_Cnt -O--CK 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 51 Comprehensive SMART error log
|
||||
0x03 GPL R/O 16383 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x13 GPL R/O 1 SATA NCQ Send and Receive log
|
||||
0x24 GPL R/O 8000 Current Device Internal Status Data log
|
||||
0x25 GPL R/O 8000 Saved Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa0 GPL VS 35328 Device vendor specific log
|
||||
0xa0 SL VS 255 Device vendor specific log
|
||||
0xa1 GPL,SL VS 4 Device vendor specific log
|
||||
0xa2 GPL,SL VS 1 Device vendor specific log
|
||||
0xa3 GPL VS 38400 Device vendor specific log
|
||||
0xa3 SL VS 255 Device vendor specific log
|
||||
0xa4 GPL VS 16477 Device vendor specific log
|
||||
0xa4 SL VS 255 Device vendor specific log
|
||||
0xa5 GPL VS 8000 Device vendor specific log
|
||||
0xa5 SL VS 255 Device vendor specific log
|
||||
0xa6 GPL VS 8000 Device vendor specific log
|
||||
0xa6 SL VS 255 Device vendor specific log
|
||||
0xa7 GPL VS 32768 Device vendor specific log
|
||||
0xa7 SL VS 255 Device vendor specific log
|
||||
0xa8-0xdf GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (16383 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Vendor (0xff) Completed without error 00% 13627 -
|
||||
# 2 Vendor (0xff) Completed without error 00% 13502 -
|
||||
# 3 Vendor (0xff) Completed without error 00% 13365 -
|
||||
# 4 Vendor (0xff) Completed without error 00% 13221 -
|
||||
# 5 Vendor (0xff) Completed without error 00% 13108 -
|
||||
# 6 Vendor (0xff) Completed without error 00% 12802 -
|
||||
# 7 Vendor (0xff) Completed without error 00% 12666 -
|
||||
# 8 Vendor (0xff) Completed without error 00% 12483 -
|
||||
# 9 Vendor (0xff) Completed without error 00% 12342 -
|
||||
#10 Vendor (0xff) Completed without error 00% 12165 -
|
||||
#11 Vendor (0xff) Completed without error 00% 11943 -
|
||||
#12 Short offline Completed without error 00% 11708 -
|
||||
#13 Vendor (0xff) Completed without error 00% 11700 -
|
||||
#14 Vendor (0xff) Completed without error 00% 11465 -
|
||||
#15 Vendor (0xff) Completed without error 00% 11269 -
|
||||
#16 Vendor (0xff) Completed without error 00% 11171 -
|
||||
#17 Short offline Completed without error 00% 10964 -
|
||||
#18 Vendor (0xff) Completed without error 00% 10940 -
|
||||
#19 Vendor (0xff) Completed without error 00% 10728 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Completed [00% left] (12627-78162)
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 33 Celsius
|
||||
Power Cycle Min/Max Temperature: 26/39 Celsius
|
||||
Lifetime Min/Max Temperature: 16/48 Celsius
|
||||
Specified Max Operating Temperature: 70 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
SMART Status: 0xc24f (PASSED)
|
||||
Minimum supported ERC Time Limit: 50 (5.0 seconds)
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -1/71 Celsius
|
||||
Temperature History Size (Index): 478 (28)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 3) ==
|
||||
0x01 0x008 4 78 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 13641 --- Power-on Hours
|
||||
0x01 0x018 6 4533600302 --- Logical Sectors Written
|
||||
0x01 0x020 6 138144254 --- Number of Write Commands
|
||||
0x01 0x028 6 2799015561 --- Logical Sectors Read
|
||||
0x01 0x030 6 57540860 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 108 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 33 --- Current Temperature
|
||||
0x05 0x010 1 35 --- Average Short Term Temperature
|
||||
0x05 0x018 1 34 --- Average Long Term Temperature
|
||||
0x05 0x020 1 48 --- Highest Temperature
|
||||
0x05 0x028 1 16 --- Lowest Temperature
|
||||
0x05 0x030 1 39 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 28 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 35 --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 31 --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 369 --- Number of Hardware Resets
|
||||
0x06 0x010 4 107 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 2 --- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x000a 4 9 Device-to-host register FISes sent due to a COMRESET
|
||||
|
||||
|
||||
|
234
SSD/Micron/1300/1300_MTFDDAK256TDL/CF9FE2B89D79
Normal file
234
SSD/Micron/1300/1300_MTFDDAK256TDL/CF9FE2B89D79
Normal file
@@ -0,0 +1,234 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.0-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Crucial/Micron Client SSDs
|
||||
Device Model: Micron_1300_MTFDDAK256TDL
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 00a075 ...
|
||||
Firmware Version: M5MU030
|
||||
User Capacity: 256,060,514,304 bytes [256 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
Form Factor: 2.5 inches
|
||||
TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
|
||||
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Wed Jun 1 06:51:14 2022 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 904) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 5) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 3) minutes.
|
||||
SCT capabilities: (0x0035) SCT Status supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 000 - 0
|
||||
5 Reallocate_NAND_Blk_Cnt -O--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 13640
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 78
|
||||
171 Program_Fail_Count -O--CK 100 100 000 - 0
|
||||
172 Erase_Fail_Count -O--CK 100 100 000 - 0
|
||||
173 Ave_Block-Erase_Count -O--CK 098 098 000 - 51
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 40
|
||||
183 SATA_Interfac_Downshift -O--CK 100 100 000 - 0
|
||||
184 Error_Correction_Count -O--CK 100 100 000 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
194 Temperature_Celsius -O---K 066 056 000 - 34 (Min/Max 16/44)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_ECC_Cnt -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0
|
||||
202 Percent_Lifetime_Remain ----CK 098 098 001 - 2
|
||||
206 Write_Error_Rate -OSR-- 100 100 000 - 0
|
||||
246 Total_LBAs_Written -O--CK 100 100 000 - 4670638674
|
||||
247 Host_Program_Page_Count -O--CK 100 100 000 - 147691647
|
||||
248 FTL_Program_Page_Count -O--CK 100 100 000 - 403104947
|
||||
180 Unused_Reserve_NAND_Blk PO--CK 000 000 000 - 308
|
||||
210 Success_RAIN_Recov_Cnt -O--CK 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 51 Comprehensive SMART error log
|
||||
0x03 GPL R/O 16383 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x13 GPL R/O 1 SATA NCQ Send and Receive log
|
||||
0x24 GPL R/O 8000 Current Device Internal Status Data log
|
||||
0x25 GPL R/O 8000 Saved Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa0 GPL VS 35328 Device vendor specific log
|
||||
0xa0 SL VS 255 Device vendor specific log
|
||||
0xa1 GPL,SL VS 4 Device vendor specific log
|
||||
0xa2 GPL,SL VS 1 Device vendor specific log
|
||||
0xa3 GPL VS 38400 Device vendor specific log
|
||||
0xa3 SL VS 255 Device vendor specific log
|
||||
0xa4 GPL VS 16477 Device vendor specific log
|
||||
0xa4 SL VS 255 Device vendor specific log
|
||||
0xa5 GPL VS 8000 Device vendor specific log
|
||||
0xa5 SL VS 255 Device vendor specific log
|
||||
0xa6 GPL VS 8000 Device vendor specific log
|
||||
0xa6 SL VS 255 Device vendor specific log
|
||||
0xa7 GPL VS 32768 Device vendor specific log
|
||||
0xa7 SL VS 255 Device vendor specific log
|
||||
0xa8-0xdf GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (16383 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Vendor (0xff) Completed without error 00% 13616 -
|
||||
# 2 Vendor (0xff) Completed without error 00% 13449 -
|
||||
# 3 Vendor (0xff) Completed without error 00% 13329 -
|
||||
# 4 Vendor (0xff) Completed without error 00% 13209 -
|
||||
# 5 Vendor (0xff) Completed without error 00% 13102 -
|
||||
# 6 Vendor (0xff) Completed without error 00% 12805 -
|
||||
# 7 Vendor (0xff) Completed without error 00% 12576 -
|
||||
# 8 Vendor (0xff) Completed without error 00% 12484 -
|
||||
# 9 Vendor (0xff) Completed without error 00% 12343 -
|
||||
#10 Vendor (0xff) Completed without error 00% 12146 -
|
||||
#11 Vendor (0xff) Completed without error 00% 11904 -
|
||||
#12 Short offline Completed without error 00% 11708 -
|
||||
#13 Vendor (0xff) Completed without error 00% 11706 -
|
||||
#14 Vendor (0xff) Completed without error 00% 11596 -
|
||||
#15 Vendor (0xff) Completed without error 00% 11409 -
|
||||
#16 Vendor (0xff) Completed without error 00% 11257 -
|
||||
#17 Vendor (0xff) Completed without error 00% 11187 -
|
||||
#18 Short offline Completed without error 00% 10964 -
|
||||
#19 Vendor (0xff) Completed without error 00% 10921 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Completed [00% left] (12741-78276)
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 34 Celsius
|
||||
Power Cycle Min/Max Temperature: 27/41 Celsius
|
||||
Lifetime Min/Max Temperature: 16/44 Celsius
|
||||
Specified Max Operating Temperature: 70 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
SMART Status: 0xc24f (PASSED)
|
||||
Minimum supported ERC Time Limit: 50 (5.0 seconds)
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -1/71 Celsius
|
||||
Temperature History Size (Index): 478 (456)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 3) ==
|
||||
0x01 0x008 4 78 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 13640 --- Power-on Hours
|
||||
0x01 0x018 6 4670638674 --- Logical Sectors Written
|
||||
0x01 0x020 6 139303916 --- Number of Write Commands
|
||||
0x01 0x028 6 2841541822 --- Logical Sectors Read
|
||||
0x01 0x030 6 44151749 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 108 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 34 --- Current Temperature
|
||||
0x05 0x010 1 36 --- Average Short Term Temperature
|
||||
0x05 0x018 1 35 --- Average Long Term Temperature
|
||||
0x05 0x020 1 44 --- Highest Temperature
|
||||
0x05 0x028 1 16 --- Lowest Temperature
|
||||
0x05 0x030 1 41 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 28 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 35 --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 31 --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 369 --- Number of Hardware Resets
|
||||
0x06 0x010 4 108 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 2 --- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x000a 4 9 Device-to-host register FISes sent due to a COMRESET
|
||||
|
||||
|
||||
|
234
SSD/Micron/1300/1300_MTFDDAK256TDL/E7F242D119A5
Normal file
234
SSD/Micron/1300/1300_MTFDDAK256TDL/E7F242D119A5
Normal file
@@ -0,0 +1,234 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.0-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Crucial/Micron Client SSDs
|
||||
Device Model: Micron_1300_MTFDDAK256TDL
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 00a075 ...
|
||||
Firmware Version: M5MU030
|
||||
User Capacity: 256,060,514,304 bytes [256 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
Form Factor: 2.5 inches
|
||||
TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
|
||||
SATA Version is: SATA 3.3, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Wed Jun 1 06:51:14 2022 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 1026) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 6) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 3) minutes.
|
||||
SCT capabilities: (0x0035) SCT Status supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 000 - 0
|
||||
5 Reallocate_NAND_Blk_Cnt -O--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 13625
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 88
|
||||
171 Program_Fail_Count -O--CK 100 100 000 - 0
|
||||
172 Erase_Fail_Count -O--CK 100 100 000 - 0
|
||||
173 Ave_Block-Erase_Count -O--CK 098 098 000 - 50
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 50
|
||||
183 SATA_Interfac_Downshift -O--CK 100 100 000 - 0
|
||||
184 Error_Correction_Count -O--CK 100 100 000 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
194 Temperature_Celsius -O---K 067 052 000 - 33 (Min/Max 17/48)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_ECC_Cnt -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0
|
||||
202 Percent_Lifetime_Remain ----CK 098 098 001 - 2
|
||||
206 Write_Error_Rate -OSR-- 100 100 000 - 0
|
||||
246 Total_LBAs_Written -O--CK 100 100 000 - 4572306408
|
||||
247 Host_Program_Page_Count -O--CK 100 100 000 - 144609774
|
||||
248 FTL_Program_Page_Count -O--CK 100 100 000 - 412864711
|
||||
180 Unused_Reserve_NAND_Blk PO--CK 000 000 000 - 308
|
||||
210 Success_RAIN_Recov_Cnt -O--CK 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 51 Comprehensive SMART error log
|
||||
0x03 GPL R/O 16383 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x13 GPL R/O 1 SATA NCQ Send and Receive log
|
||||
0x24 GPL R/O 8000 Current Device Internal Status Data log
|
||||
0x25 GPL R/O 8000 Saved Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa0 GPL VS 35328 Device vendor specific log
|
||||
0xa0 SL VS 255 Device vendor specific log
|
||||
0xa1 GPL,SL VS 4 Device vendor specific log
|
||||
0xa2 GPL,SL VS 1 Device vendor specific log
|
||||
0xa3 GPL VS 38400 Device vendor specific log
|
||||
0xa3 SL VS 255 Device vendor specific log
|
||||
0xa4 GPL VS 16477 Device vendor specific log
|
||||
0xa4 SL VS 255 Device vendor specific log
|
||||
0xa5 GPL VS 8000 Device vendor specific log
|
||||
0xa5 SL VS 255 Device vendor specific log
|
||||
0xa6 GPL VS 8000 Device vendor specific log
|
||||
0xa6 SL VS 255 Device vendor specific log
|
||||
0xa7 GPL VS 32768 Device vendor specific log
|
||||
0xa7 SL VS 255 Device vendor specific log
|
||||
0xa8-0xdf GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (16383 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Vendor (0xff) Completed without error 00% 13601 -
|
||||
# 2 Vendor (0xff) Completed without error 00% 13483 -
|
||||
# 3 Vendor (0xff) Completed without error 00% 13339 -
|
||||
# 4 Vendor (0xff) Completed without error 00% 13195 -
|
||||
# 5 Vendor (0xff) Completed without error 00% 13093 -
|
||||
# 6 Vendor (0xff) Completed without error 00% 12789 -
|
||||
# 7 Vendor (0xff) Completed without error 00% 12648 -
|
||||
# 8 Vendor (0xff) Completed without error 00% 12467 -
|
||||
# 9 Vendor (0xff) Completed without error 00% 12342 -
|
||||
#10 Vendor (0xff) Completed without error 00% 12160 -
|
||||
#11 Vendor (0xff) Completed without error 00% 11928 -
|
||||
#12 Short offline Completed without error 00% 11708 -
|
||||
#13 Vendor (0xff) Completed without error 00% 11653 -
|
||||
#14 Vendor (0xff) Completed without error 00% 11443 -
|
||||
#15 Vendor (0xff) Completed without error 00% 11264 -
|
||||
#16 Vendor (0xff) Completed without error 00% 11175 -
|
||||
#17 Short offline Completed without error 00% 10964 -
|
||||
#18 Vendor (0xff) Completed without error 00% 10938 -
|
||||
#19 Vendor (0xff) Completed without error 00% 10728 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Completed [00% left] (12188-77723)
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 33 Celsius
|
||||
Power Cycle Min/Max Temperature: 28/39 Celsius
|
||||
Lifetime Min/Max Temperature: 17/48 Celsius
|
||||
Specified Max Operating Temperature: 70 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
SMART Status: 0xc24f (PASSED)
|
||||
Minimum supported ERC Time Limit: 50 (5.0 seconds)
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -1/71 Celsius
|
||||
Temperature History Size (Index): 478 (366)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 3) ==
|
||||
0x01 0x008 4 88 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 13625 --- Power-on Hours
|
||||
0x01 0x018 6 4572306408 --- Logical Sectors Written
|
||||
0x01 0x020 6 137329425 --- Number of Write Commands
|
||||
0x01 0x028 6 2836134622 --- Logical Sectors Read
|
||||
0x01 0x030 6 54258009 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 108 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 33 --- Current Temperature
|
||||
0x05 0x010 1 36 --- Average Short Term Temperature
|
||||
0x05 0x018 1 35 --- Average Long Term Temperature
|
||||
0x05 0x020 1 48 --- Highest Temperature
|
||||
0x05 0x028 1 17 --- Lowest Temperature
|
||||
0x05 0x030 1 40 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 28 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 35 --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 31 --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 382 --- Number of Hardware Resets
|
||||
0x06 0x010 4 108 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 2 --- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x000a 4 9 Device-to-host register FISes sent due to a COMRESET
|
||||
|
||||
|
||||
|
Reference in New Issue
Block a user