smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p5 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Crucial/Micron Client SSDs
|
||||
Device Model: MTFDDAV256MBF-1AN15ABHA
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 00a075 ...
|
||||
Firmware Version: M6T3
|
||||
User Capacity: 256,060,514,304 bytes [256 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
Form Factor: < 1.8 inches
|
||||
TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-3 T13/2161-D revision 4
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Fri Dec 30 03:01:01 2022 UTC
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 254 (maximum performance)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x80) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 814) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 15) minutes.
|
||||
SCT capabilities: (0x0035) SCT Status supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 32
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 050 - 0
|
||||
5 Reallocate_NAND_Blk_Cnt PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 18934
|
||||
11 Unknown_SSD_Attribute -O---K 100 100 000 - 462
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 1915
|
||||
171 Program_Fail_Count -O---K 100 100 000 - 0
|
||||
172 Erase_Fail_Count -O--CK 100 100 000 - 0
|
||||
173 Ave_Block-Erase_Count PO--CK 090 090 010 - 312
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 462
|
||||
181 Program_Fail_Cnt_Total -O---K 100 100 000 - 10359530194254
|
||||
183 SATA_Interfac_Downshift -O--CK 100 100 000 - 0
|
||||
184 Error_Correction_Count PO--CK 100 100 097 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 1547
|
||||
194 Temperature_Celsius -O---K 049 029 000 - 51 (Min/Max 11/71)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O---K 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 51 Comprehensive SMART error log
|
||||
0x03 GPL R/O 16383 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x13 GPL R/O 1 SATA NCQ Send and Receive log
|
||||
0x24 GPL R/O 16000 Current Device Internal Status Data log
|
||||
0x25 GPL R/O 16000 Saved Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa0 GPL VS 2000 Device vendor specific log
|
||||
0xa0 SL VS 208 Device vendor specific log
|
||||
0xa1-0xb5 GPL,SL VS 1 Device vendor specific log
|
||||
0xb6 GPL VS 8193 Device vendor specific log
|
||||
0xb7-0xbf GPL,SL VS 1 Device vendor specific log
|
||||
0xc0 GPL,SL VS 80 Device vendor specific log
|
||||
0xc1-0xdf GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (16383 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Vendor (0xff) Completed without error 00% 9410 -
|
||||
# 2 Vendor (0xff) Completed without error 00% 9396 -
|
||||
# 3 Vendor (0xff) Completed without error 00% 9277 -
|
||||
# 4 Vendor (0xff) Completed without error 00% 9102 -
|
||||
# 5 Vendor (0xff) Completed without error 00% 9050 -
|
||||
# 6 Vendor (0xff) Completed without error 00% 9014 -
|
||||
# 7 Vendor (0xff) Completed without error 00% 8972 -
|
||||
# 8 Vendor (0xff) Completed without error 00% 8930 -
|
||||
# 9 Vendor (0xff) Completed without error 00% 8903 -
|
||||
#10 Vendor (0xff) Completed without error 00% 8861 -
|
||||
#11 Vendor (0xff) Completed without error 00% 8819 -
|
||||
#12 Vendor (0xff) Completed without error 00% 871 -
|
||||
#13 Vendor (0xff) Completed without error 00% 722 -
|
||||
#14 Short offline Completed without error 00% 1 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 51 Celsius
|
||||
Power Cycle Min/Max Temperature: 50/59 Celsius
|
||||
Lifetime Min/Max Temperature: 11/71 Celsius
|
||||
Specified Max Operating Temperature: 70 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (162)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 1915 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 18934 --- Power-on Hours
|
||||
0x01 0x018 6 46256469857 --- Logical Sectors Written
|
||||
0x01 0x020 6 723505803 --- Number of Write Commands
|
||||
0x01 0x028 6 18821321386 --- Logical Sectors Read
|
||||
0x01 0x030 6 278762466 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 1547 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 51 --- Current Temperature
|
||||
0x05 0x010 1 49 --- Average Short Term Temperature
|
||||
0x05 0x018 1 49 --- Average Long Term Temperature
|
||||
0x05 0x020 1 71 --- Highest Temperature
|
||||
0x05 0x028 1 11 --- Lowest Temperature
|
||||
0x05 0x030 1 55 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 36 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 50 --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 44 --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 0 --- Time in Over-Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 7357 --- Number of Hardware Resets
|
||||
0x06 0x010 4 1723 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 10 N-- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x000a 4 19 Device-to-host register FISes sent due to a COMRESET
|
||||
|
Reference in New Issue
Block a user