mirror of
https://github.com/bsdhw/SMART.git
synced 2025-05-31 16:21:41 +05:30
Update of reports (new: 3633, modified: 0)
This commit is contained in:
153
SSD/OCZ/VERTEX2/VERTEX2 120GB/7F5135749425
Normal file
153
SSD/OCZ/VERTEX2/VERTEX2 120GB/7F5135749425
Normal file
@@ -0,0 +1,153 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RELEASE-p11 amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: SandForce Driven SSDs
|
||||
Device Model: OCZ-VERTEX2
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 e83a97 ...
|
||||
Firmware Version: 1.23
|
||||
User Capacity: 120,034,123,776 bytes [120 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
TRIM Command: Available, deterministic
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s
|
||||
Local Time is: Thu Jun 16 10:40:40 2022 EDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Unknown (0x100)
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7f) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Abort Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 48) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x003d) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 120 120 050 - 0/0
|
||||
5 Retired_Block_Count PO--CK 100 100 003 - 0
|
||||
9 Power_On_Hours_and_Msec -O--CK 100 100 000 - 1813h+56m+15.460s
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 729
|
||||
171 Program_Fail_Count -O--CK 000 000 000 - 0
|
||||
172 Erase_Fail_Count -O--CK 000 000 000 - 0
|
||||
174 Unexpect_Power_Loss_Ct ----CK 000 000 000 - 32
|
||||
177 Wear_Range_Delta ------ 000 000 000 - 0
|
||||
181 Program_Fail_Count -O--CK 000 000 000 - 0
|
||||
182 Erase_Fail_Count -O--CK 000 000 000 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
194 Temperature_Celsius -O---K 001 129 000 - 1 (0 127 0 129 0)
|
||||
195 ECC_Uncorr_Error_Count --SRC- 120 120 000 - 0/0
|
||||
196 Reallocated_Event_Count PO--CK 100 100 000 - 0
|
||||
231 SSD_Life_Left PO--C- 100 100 010 - 0
|
||||
233 SandForce_Internal ------ 000 000 000 - 1664
|
||||
234 SandForce_Internal -O--CK 000 000 000 - 3072
|
||||
241 Lifetime_Writes_GiB -O--CK 000 000 000 - 3072
|
||||
242 Lifetime_Reads_GiB -O--CK 000 000 000 - 5376
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL,SL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xb7 GPL,SL VS 16 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
|
||||
|
||||
SMART Error Log not supported
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 0 (0x0000)
|
||||
Device State: Active (0)
|
||||
Current Temperature: ? Celsius
|
||||
Power Cycle Min/Max Temperature: 127/-127 Celsius
|
||||
Lifetime Min/Max Temperature: 127/-127 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: ?/ ? Celsius
|
||||
Min/Max Temperature Limit: ?/ ? Celsius
|
||||
Temperature History Size (Index): 478 (479)
|
||||
Invalid Temperature History Size or Index
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 256 (25.6 seconds)
|
||||
Write: 256 (25.6 seconds)
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x000a 2 0 Device-to-host register FISes sent due to a COMRESET
|
||||
|
153
SSD/OCZ/VERTEX2/VERTEX2 80GB/FF7BBCFFEB62
Normal file
153
SSD/OCZ/VERTEX2/VERTEX2 80GB/FF7BBCFFEB62
Normal file
@@ -0,0 +1,153 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.0-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: SandForce Driven SSDs
|
||||
Device Model: OCZ-VERTEX2
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 e83a97 ...
|
||||
Firmware Version: 1.35
|
||||
User Capacity: 80,026,361,856 bytes [80.0 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
TRIM Command: Available, deterministic
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s
|
||||
Local Time is: Fri May 20 21:12:18 2022 EDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Unknown (0x100)
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7f) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Abort Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 5) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x003d) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 109 109 050 - 0/23182297
|
||||
5 Retired_Block_Count PO--CK 100 100 003 - 0
|
||||
9 Power_On_Hours_and_Msec -O--CK 100 100 000 - 878h+54m+54.740s
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 71
|
||||
171 Program_Fail_Count -O--CK 000 000 000 - 0
|
||||
172 Erase_Fail_Count -O--CK 000 000 000 - 0
|
||||
174 Unexpect_Power_Loss_Ct ----CK 000 000 000 - 40
|
||||
177 Wear_Range_Delta ------ 000 000 000 - 2
|
||||
181 Program_Fail_Count -O--CK 000 000 000 - 0
|
||||
182 Erase_Fail_Count -O--CK 000 000 000 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
194 Temperature_Celsius -O---K 030 030 000 - 30 (Min/Max 30/30)
|
||||
195 ECC_Uncorr_Error_Count --SRC- 109 109 000 - 0/23182297
|
||||
196 Reallocated_Event_Count PO--CK 100 100 000 - 0
|
||||
231 SSD_Life_Left PO--C- 100 100 010 - 0
|
||||
233 SandForce_Internal ------ 000 000 000 - 4160
|
||||
234 SandForce_Internal -O--CK 000 000 000 - 5120
|
||||
241 Lifetime_Writes_GiB -O--CK 000 000 000 - 5120
|
||||
242 Lifetime_Reads_GiB -O--CK 000 000 000 - 640
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL,SL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xb7 GPL,SL VS 16 Device vendor specific log
|
||||
0xc0-0xc1 GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
|
||||
|
||||
SMART Error Log not supported
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 0 (0x0000)
|
||||
Device State: Active (0)
|
||||
Current Temperature: ? Celsius
|
||||
Power Cycle Min/Max Temperature: 127/-127 Celsius
|
||||
Lifetime Min/Max Temperature: 127/-127 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: ?/ ? Celsius
|
||||
Min/Max Temperature Limit: ?/ ? Celsius
|
||||
Temperature History Size (Index): 478 (138)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 256 (25.6 seconds)
|
||||
Write: 256 (25.6 seconds)
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
|
||||
|
Reference in New Issue