smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Samsung based SSDs
Device Model: SAMSUNG SSD PM810 2.5" 128GB
Serial Number: --
LU WWN Device Id: 5 0000f0 ...
Firmware Version: AXM06D1Q
User Capacity: 128,035,676,160 bytes [128 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
TRIM Command: Available
Device is: In smartctl database 7.3/5319
ATA Version is: ATA8-ACS, ATA/ATAPI-7 T13/1532D revision 1
SATA Version is: SATA 2.6, 3.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Wed Jul 6 18:12:27 2022 EDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Disabled
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 840) seconds.
Offline data collection
capabilities: (0x53) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 14) minutes.
SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocated_Sector_Ct PO--CK 099 099 --- - 28
9 Power_On_Hours -O--CK 097 097 --- - 14971
12 Power_Cycle_Count -O--CK 099 099 --- - 908
175 Program_Fail_Count_Chip -O--CK 098 098 --- - 21
176 Erase_Fail_Count_Chip -O--CK 100 100 --- - 0
177 Wear_Leveling_Count PO--C- 098 098 --- - 59
178 Used_Rsvd_Blk_Cnt_Chip PO--C- 078 078 --- - 428
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 080 080 --- - 800
180 Unused_Rsvd_Blk_Cnt_Tot PO--C- 080 080 --- - 3232
181 Program_Fail_Cnt_Total -O--CK 099 099 --- - 28
182 Erase_Fail_Count_Total -O--CK 100 100 --- - 0
183 Runtime_Bad_Block PO--C- 099 099 --- - 28
187 Uncorrectable_Error_Cnt -O--CK 100 100 --- - 0
195 ECC_Error_Rate -O-RC- 200 200 --- - 0
198 Offline_Uncorrectable ----CK 100 100 --- - 0
199 CRC_Error_Count -OSRCK 253 253 --- - 0
232 Available_Reservd_Space PO--C- 078 078 --- - 1588
241 Total_LBAs_Written -O--CK 014 014 --- - 3689731944
242 Total_LBAs_Read -O--CK 028 028 --- - 3122911613
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 0
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 GPL,SL R/O 1 Summary SMART error log
0x02 GPL,SL R/O 1 Comprehensive SMART error log
0x03 GPL,SL R/O 1 Ext. Comprehensive SMART error log
0x06 GPL,SL R/O 1 SMART self-test log
0x07 GPL,SL R/O 1 Extended self-test log
0x09 GPL,SL R/W 1 Selective self-test log
0x10 GPL,SL R/O 1 NCQ Command Error log
0x11 GPL,SL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 1 Host vendor specific log
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
No Errors Logged
Warning! SMART Extended Self-test Log Structure error: invalid SMART checksum.
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 0 -
# 2 Short offline Completed without error 00% 0 -
# 3 Short offline Completed without error 00% 0 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Commands not supported
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 3 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC

View File

@@ -0,0 +1,144 @@
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p2 amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Samsung based SSDs
Device Model: SAMSUNG SSD PM810 2.5" 256GB
Serial Number: --
LU WWN Device Id: 5 0000f0 ...
Firmware Version: AXM08D1Q
User Capacity: 256,060,514,304 bytes [256 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
TRIM Command: Available
Device is: In smartctl database 7.3/5319
ATA Version is: ATA8-ACS, ATA/ATAPI-7 T13/1532D revision 1
SATA Version is: SATA 2.6, 3.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Mon Sep 19 12:50:51 2022 EDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM level is: 128 (quiet), recommended: 128
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 41) The self-test routine was interrupted
by the host with a hard or soft reset.
Total time to complete Offline
data collection: ( 1680) seconds.
Offline data collection
capabilities: (0x53) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 28) minutes.
SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocated_Sector_Ct PO--CK 100 100 --- - 0
9 Power_On_Hours -O--CK 099 099 --- - 1612
12 Power_Cycle_Count -O--CK 099 099 --- - 935
175 Program_Fail_Count_Chip -O--CK 100 100 --- - 0
176 Erase_Fail_Count_Chip -O--CK 100 100 --- - 0
177 Wear_Leveling_Count PO--C- 099 099 --- - 15
178 Used_Rsvd_Blk_Cnt_Chip PO--C- 075 075 --- - 986
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 076 076 --- - 1898
180 Unused_Rsvd_Blk_Cnt_Tot PO--C- 076 076 --- - 6166
181 Program_Fail_Cnt_Total -O--CK 100 100 --- - 0
182 Erase_Fail_Count_Total -O--CK 100 100 --- - 0
183 Runtime_Bad_Block PO--C- 100 100 --- - 0
187 Uncorrectable_Error_Cnt -O--CK 100 100 --- - 0
195 ECC_Error_Rate -O-RC- 200 200 --- - 0
198 Offline_Uncorrectable ----CK 100 100 --- - 0
199 CRC_Error_Count -OSRCK 253 253 --- - 5
232 Available_Reservd_Space PO--C- 075 075 --- - 3046
241 Total_LBAs_Written -O--CK 006 006 --- - 4067332688
242 Total_LBAs_Read -O--CK 077 077 --- - 972610514
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 0
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 GPL,SL R/O 1 Summary SMART error log
0x02 GPL,SL R/O 1 Comprehensive SMART error log
0x03 GPL,SL R/O 1 Ext. Comprehensive SMART error log
0x06 GPL,SL R/O 1 SMART self-test log
0x07 GPL,SL R/O 1 Extended self-test log
0x09 GPL,SL R/W 1 Selective self-test log
0x10 GPL,SL R/O 1 NCQ Command Error log
0x11 GPL,SL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 1 Host vendor specific log
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
No Errors Logged
Warning! SMART Extended Self-test Log Structure error: invalid SMART checksum.
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended offline Interrupted (host reset) 90% 471 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Commands not supported
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 8 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 7 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC

View File

@@ -0,0 +1,228 @@
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p2 amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Samsung based SSDs
Device Model: SAMSUNG SSD PM810 2.5" 256GB
Serial Number: --
LU WWN Device Id: 5 0000f0 ...
Firmware Version: AXM08D1Q
User Capacity: 256,060,514,304 bytes [256 GB]
Sector Size: 512 bytes logical/physical
Rotation Rate: Solid State Device
TRIM Command: Available
Device is: In smartctl database 7.3/5319
ATA Version is: ATA8-ACS, ATA/ATAPI-7 T13/1532D revision 1
SATA Version is: SATA 2.6, 3.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Sat Oct 22 00:55:02 2022 EDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM level is: 254 (maximum performance), recommended: 128
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 1680) seconds.
Offline data collection
capabilities: (0x53) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
No Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 28) minutes.
SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocated_Sector_Ct PO--CK 099 099 --- - 7
9 Power_On_Hours -O--CK 092 092 --- - 35680
12 Power_Cycle_Count -O--CK 097 097 --- - 2030
175 Program_Fail_Count_Chip -O--CK 099 099 --- - 5
176 Erase_Fail_Count_Chip -O--CK 100 100 --- - 0
177 Wear_Leveling_Count PO--C- 089 089 --- - 395
178 Used_Rsvd_Blk_Cnt_Chip PO--C- 081 081 --- - 746
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 081 081 --- - 1492
180 Unused_Rsvd_Blk_Cnt_Tot PO--C- 081 081 --- - 6572
181 Program_Fail_Cnt_Total -O--CK 099 099 --- - 7
182 Erase_Fail_Count_Total -O--CK 100 100 --- - 0
183 Runtime_Bad_Block PO--C- 099 099 --- - 7
187 Uncorrectable_Error_Cnt -O--CK 099 099 --- - 6
195 ECC_Error_Rate -O-RC- 199 199 --- - 6
198 Offline_Uncorrectable ----CK 100 100 --- - 0
199 CRC_Error_Count -OSRCK 253 253 --- - 0
232 Available_Reservd_Space PO--C- 081 081 --- - 3286
241 Total_LBAs_Written -O--CK 044 044 --- - 2406504234
242 Total_LBAs_Read -O--CK 063 063 --- - 1590330469
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 0
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 GPL,SL R/O 1 Summary SMART error log
0x02 GPL,SL R/O 1 Comprehensive SMART error log
0x03 GPL,SL R/O 1 Ext. Comprehensive SMART error log
0x06 GPL,SL R/O 1 SMART self-test log
0x07 GPL,SL R/O 1 Extended self-test log
0x09 GPL,SL R/W 1 Selective self-test log
0x10 GPL,SL R/O 1 NCQ Command Error log
0x11 GPL,SL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 1 Host vendor specific log
Warning! SMART Extended Comprehensive Error Log Structure error: invalid SMART checksum.
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
Device Error Count: 5 (device log contains only the most recent 4 errors)
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 5 [0] occurred at disk power-on lifetime: 10487 hours (436 days + 23 hours)
When the command that caused the error occurred, the device was sleeping.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 02 00 00 00 30 24 4e e1 00 Error:
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
ef 00 10 00 02 00 00 00 00 00 00 00 00 00:07:35.000 SET FEATURES [Enable SATA feature]
27 00 00 00 00 00 00 00 00 00 00 00 00 00:07:35.000 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
ec 00 00 00 01 00 00 00 00 00 00 00 00 00:07:35.000 IDENTIFY DEVICE
ef 00 03 00 46 00 00 00 00 00 00 00 00 00:07:35.000 SET FEATURES [Set transfer mode]
ef 00 10 00 02 00 00 00 00 00 00 00 00 00:07:35.000 SET FEATURES [Enable SATA feature]
Error 4 [3] occurred at disk power-on lifetime: 10487 hours (436 days + 23 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 02 00 00 01 30 24 4e 40 00 Error:
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
ef 00 10 00 02 00 00 00 00 00 00 00 00 00:07:35.000 SET FEATURES [Enable SATA feature]
27 00 00 00 00 00 00 00 00 00 00 00 00 00:07:35.000 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
ec 00 00 00 01 00 00 00 00 00 00 00 00 00:07:35.000 IDENTIFY DEVICE
ef 00 03 00 46 00 00 00 00 00 00 00 00 00:07:35.000 SET FEATURES [Set transfer mode]
ef 00 10 00 02 00 00 00 00 00 00 00 00 00:07:35.000 SET FEATURES [Enable SATA feature]
Error 3 [2] occurred at disk power-on lifetime: 10487 hours (436 days + 23 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 02 00 00 01 30 24 4e 40 00 Error:
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
ef 00 10 00 02 00 00 00 00 00 00 00 00 00:07:34.000 SET FEATURES [Enable SATA feature]
27 00 00 00 00 00 00 00 00 00 00 00 00 00:07:34.000 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
ec 00 00 00 01 00 00 00 00 00 00 00 00 00:07:34.000 IDENTIFY DEVICE
ef 00 03 00 46 00 00 00 00 00 00 00 00 00:07:34.000 SET FEATURES [Set transfer mode]
ef 00 10 00 02 00 00 00 00 00 00 00 00 00:07:34.000 SET FEATURES [Enable SATA feature]
Error 2 [1] occurred at disk power-on lifetime: 10487 hours (436 days + 23 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 02 00 00 01 30 24 4e 40 00 Error:
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
ef 00 10 00 02 00 00 00 00 00 00 00 00 00:07:34.000 SET FEATURES [Enable SATA feature]
27 00 00 00 00 00 00 00 00 00 00 00 00 00:07:34.000 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
ec 00 00 00 01 00 00 00 00 00 00 00 00 00:07:34.000 IDENTIFY DEVICE
ef 00 03 00 46 00 00 00 00 00 00 00 00 00:07:34.000 SET FEATURES [Set transfer mode]
ef 00 10 00 02 00 00 00 00 00 00 00 00 00:07:34.000 SET FEATURES [Enable SATA feature]
Warning! SMART Extended Self-test Log Structure error: invalid SMART checksum.
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 3083 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Commands not supported
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x0002 2 0 R_ERR response for data FIS
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 23 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 23 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC