160
SSD/Transcend/TS32/TS32ASTME0000A/C1D071CD1CBD
Normal file
160
SSD/Transcend/TS32/TS32ASTME0000A/C1D071CD1CBD
Normal file
@@ -0,0 +1,160 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p2 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Device Model: TS32ASTME0000A
|
||||
Serial Number: --
|
||||
Firmware Version: N1114A
|
||||
User Capacity: 32,017,047,552 bytes [32.0 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
TRIM Command: Available, deterministic, zeroed
|
||||
Device is: Not in smartctl database 7.3/5319
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Tue Nov 1 23:29:46 2022 CST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x71) SMART execute Offline immediate.
|
||||
No Auto Offline data collection support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0002) Does not save SMART data before
|
||||
entering power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 10) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
|
||||
SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate ------ 100 100 000 - 0
|
||||
5 Reallocated_Sector_Ct ------ 100 100 000 - 0
|
||||
9 Power_On_Hours ------ 100 100 000 - 2634
|
||||
12 Power_Cycle_Count ------ 100 100 000 - 136
|
||||
160 Unknown_Attribute ------ 100 100 000 - 0
|
||||
161 Unknown_Attribute ------ 100 100 000 - 53
|
||||
163 Unknown_Attribute ------ 100 100 000 - 15
|
||||
164 Unknown_Attribute ------ 100 100 000 - 102788
|
||||
165 Unknown_Attribute ------ 100 100 000 - 145
|
||||
166 Unknown_Attribute ------ 100 100 000 - 45
|
||||
167 Unknown_Attribute ------ 100 100 000 - 100
|
||||
168 Unknown_Attribute ------ 100 100 000 - 3000
|
||||
169 Unknown_Attribute ------ 100 100 000 - 97
|
||||
175 Program_Fail_Count_Chip ------ 100 100 000 - 0
|
||||
176 Erase_Fail_Count_Chip ------ 100 100 000 - 0
|
||||
177 Wear_Leveling_Count ------ 100 100 050 - 479
|
||||
178 Used_Rsvd_Blk_Cnt_Chip ------ 100 100 000 - 0
|
||||
181 Program_Fail_Cnt_Total ------ 100 100 000 - 0
|
||||
182 Erase_Fail_Count_Total ------ 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count ------ 100 100 000 - 78
|
||||
194 Temperature_Celsius ------ 100 100 000 - 39
|
||||
195 Hardware_ECC_Recovered ------ 100 100 000 - 3
|
||||
196 Reallocated_Event_Count ------ 100 100 016 - 0
|
||||
197 Current_Pending_Sector ------ 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ------ 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count ------ 100 100 050 - 0
|
||||
232 Available_Reservd_Space ------ 100 100 000 - 100
|
||||
241 Total_LBAs_Written ------ 100 100 000 - 51040
|
||||
242 Total_LBAs_Read ------ 100 100 000 - 3900
|
||||
245 Unknown_Attribute ------ 100 100 000 - 102788
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 GPL,SL R/O 1 Summary SMART error log
|
||||
0x02 GPL,SL R/O 1 Comprehensive SMART error log
|
||||
0x03 GPL,SL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 GPL,SL R/O 1 SMART self-test log
|
||||
0x07 GPL,SL R/O 1 Extended self-test log
|
||||
0x09 GPL,SL R/W 1 Selective self-test log
|
||||
0x10 GPL,SL R/O 1 NCQ Command Error log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Commands not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 136 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 2634 --- Power-on Hours
|
||||
0x01 0x018 6 3344985640 --- Logical Sectors Written
|
||||
0x01 0x020 6 147507324 --- Number of Write Commands
|
||||
0x01 0x028 6 255649806 --- Logical Sectors Read
|
||||
0x01 0x030 6 4479873 --- Number of Read Commands
|
||||
0x02 ===== = = === == Free-Fall Statistics (empty) ==
|
||||
0x03 ===== = = === == Rotating Media Statistics (empty) ==
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 78 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (empty) ==
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 268 --- Number of Hardware Resets
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 3 --- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11) not supported
|
||||
|
162
SSD/Transcend/TS32/TS32GMSA370/05272EF16F1A
Normal file
162
SSD/Transcend/TS32/TS32GMSA370/05272EF16F1A
Normal file
@@ -0,0 +1,162 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p2 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Silicon Motion based SSDs
|
||||
Device Model: TS32GMSA370
|
||||
Serial Number: --
|
||||
Firmware Version: P1225CE
|
||||
User Capacity: 32,017,047,552 bytes [32.0 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat Sep 3 17:52:32 2022 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x71) SMART execute Offline immediate.
|
||||
No Auto Offline data collection support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0002) Does not save SMART data before
|
||||
entering power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
|
||||
SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate ------ 100 100 000 - 0
|
||||
5 Reallocated_Sector_Ct ------ 100 100 000 - 0
|
||||
9 Power_On_Hours ------ 100 100 000 - 459
|
||||
12 Power_Cycle_Count ------ 100 100 000 - 13
|
||||
160 Uncorrectable_Error_Cnt ------ 100 100 000 - 0
|
||||
161 Valid_Spare_Block_Cnt ------ 100 100 000 - 75
|
||||
163 Initial_Bad_Block_Count ------ 100 100 000 - 7
|
||||
164 Total_Erase_Count ------ 100 100 000 - 97802
|
||||
165 Max_Erase_Count ------ 100 100 000 - 142
|
||||
166 Min_Erase_Count ------ 100 100 000 - 42
|
||||
167 Average_Erase_Count ------ 100 100 000 - 93
|
||||
168 Max_Erase_Count_of_Spec ------ 100 100 000 - 3000
|
||||
169 Remaining_Lifetime_Perc ------ 100 100 000 - 97
|
||||
175 Program_Fail_Count_Chip ------ 100 100 000 - 0
|
||||
176 Erase_Fail_Count_Chip ------ 100 100 000 - 0
|
||||
177 Wear_Leveling_Count ------ 100 100 050 - 43
|
||||
178 Runtime_Invalid_Blk_Cnt ------ 100 100 000 - 0
|
||||
181 Program_Fail_Cnt_Total ------ 100 100 000 - 0
|
||||
182 Erase_Fail_Count_Total ------ 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count ------ 100 100 000 - 3
|
||||
194 Temperature_Celsius ------ 100 100 000 - 67
|
||||
195 Hardware_ECC_Recovered ------ 100 100 000 - 0
|
||||
196 Reallocated_Event_Count ------ 100 100 016 - 0
|
||||
197 Current_Pending_Sector ------ 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ------ 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count ------ 100 100 050 - 0
|
||||
232 Available_Reservd_Space ------ 100 100 000 - 100
|
||||
241 Host_Writes_32MiB ------ 100 100 000 - 37525
|
||||
242 Host_Reads_32MiB ------ 100 100 000 - 328
|
||||
245 TLC_Writes_32MiB ------ 100 100 000 - 97802
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 GPL,SL R/O 1 Summary SMART error log
|
||||
0x02 GPL,SL R/O 1 Comprehensive SMART error log
|
||||
0x03 GPL,SL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 GPL,SL R/O 1 SMART self-test log
|
||||
0x07 GPL,SL R/O 1 Extended self-test log
|
||||
0x09 GPL,SL R/W 1 Selective self-test log
|
||||
0x10 GPL,SL R/O 1 NCQ Command Error log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
6 0 65535 Read_scanning was never started
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Commands not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 13 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 459 --- Power-on Hours
|
||||
0x01 0x018 6 2459295331 --- Logical Sectors Written
|
||||
0x01 0x020 6 38288193 --- Number of Write Commands
|
||||
0x01 0x028 6 21510331 --- Logical Sectors Read
|
||||
0x01 0x030 6 754731 --- Number of Read Commands
|
||||
0x02 ===== = = === == Free-Fall Statistics (empty) ==
|
||||
0x03 ===== = = === == Rotating Media Statistics (empty) ==
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 3 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (empty) ==
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 3016 --- Number of Hardware Resets
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 3 --- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11) not supported
|
||||
|
161
SSD/Transcend/TS32/TS32GMSA370/EEFCA4199A0A
Normal file
161
SSD/Transcend/TS32/TS32GMSA370/EEFCA4199A0A
Normal file
@@ -0,0 +1,161 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p2 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Silicon Motion based SSDs
|
||||
Device Model: TS32GMSA370
|
||||
Serial Number: --
|
||||
Firmware Version: N1114B
|
||||
User Capacity: 32,017,047,552 bytes [32.0 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Tue Oct 18 10:10:16 2022 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x71) SMART execute Offline immediate.
|
||||
No Auto Offline data collection support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0002) Does not save SMART data before
|
||||
entering power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 10) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
|
||||
SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate ------ 100 100 000 - 0
|
||||
5 Reallocated_Sector_Ct ------ 100 100 000 - 0
|
||||
9 Power_On_Hours ------ 100 100 000 - 3220
|
||||
12 Power_Cycle_Count ------ 100 100 000 - 146
|
||||
160 Uncorrectable_Error_Cnt ------ 100 100 000 - 0
|
||||
161 Valid_Spare_Block_Cnt ------ 100 100 000 - 49
|
||||
163 Initial_Bad_Block_Count ------ 100 100 000 - 19
|
||||
164 Total_Erase_Count ------ 100 100 000 - 4987586
|
||||
165 Max_Erase_Count ------ 100 100 000 - 4923
|
||||
166 Min_Erase_Count ------ 100 100 000 - 4822
|
||||
167 Average_Erase_Count ------ 100 100 000 - 4880
|
||||
168 Max_Erase_Count_of_Spec ------ 100 100 000 - 3000
|
||||
169 Remaining_Lifetime_Perc ------ 100 100 000 - 0
|
||||
175 Program_Fail_Count_Chip ------ 100 100 000 - 0
|
||||
176 Erase_Fail_Count_Chip ------ 100 100 000 - 0
|
||||
177 Wear_Leveling_Count ------ 100 100 050 - 33056
|
||||
178 Runtime_Invalid_Blk_Cnt ------ 100 100 000 - 0
|
||||
181 Program_Fail_Cnt_Total ------ 100 100 000 - 0
|
||||
182 Erase_Fail_Count_Total ------ 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count ------ 100 100 000 - 29
|
||||
194 Temperature_Celsius ------ 100 100 000 - 50
|
||||
195 Hardware_ECC_Recovered ------ 100 100 000 - 149
|
||||
196 Reallocated_Event_Count ------ 100 100 016 - 0
|
||||
197 Current_Pending_Sector ------ 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ------ 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count ------ 100 100 050 - 0
|
||||
232 Available_Reservd_Space ------ 100 100 000 - 100
|
||||
241 Host_Writes_32MiB ------ 100 100 000 - 986032
|
||||
242 Host_Reads_32MiB ------ 100 100 000 - 117718
|
||||
245 TLC_Writes_32MiB ------ 100 100 000 - 4987586
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 GPL,SL R/O 1 Summary SMART error log
|
||||
0x02 GPL,SL R/O 1 Comprehensive SMART error log
|
||||
0x03 GPL,SL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 GPL,SL R/O 1 SMART self-test log
|
||||
0x07 GPL,SL R/O 1 Extended self-test log
|
||||
0x09 GPL,SL R/W 1 Selective self-test log
|
||||
0x10 GPL,SL R/O 1 NCQ Command Error log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Commands not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 146 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 3220 --- Power-on Hours
|
||||
0x01 0x018 6 196134722 --- Logical Sectors Written
|
||||
0x01 0x020 6 2022432312 --- Number of Write Commands
|
||||
0x01 0x028 6 3419821892 --- Logical Sectors Read
|
||||
0x01 0x030 6 297872886 --- Number of Read Commands
|
||||
0x02 ===== = = === == Free-Fall Statistics (empty) ==
|
||||
0x03 ===== = = === == Rotating Media Statistics (empty) ==
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 29 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (empty) ==
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 3225 --- Number of Hardware Resets
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 162 --- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11) not supported
|
||||
|
162
SSD/Transcend/TS32/TS32GMSA370/FB5A33770259
Normal file
162
SSD/Transcend/TS32/TS32GMSA370/FB5A33770259
Normal file
@@ -0,0 +1,162 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p5 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Silicon Motion based SSDs
|
||||
Device Model: TS32GMSA370
|
||||
Serial Number: --
|
||||
Firmware Version: O0918B
|
||||
User Capacity: 32,017,047,552 bytes [32.0 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Thu Dec 29 00:21:54 2022 CET
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x71) SMART execute Offline immediate.
|
||||
No Auto Offline data collection support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0002) Does not save SMART data before
|
||||
entering power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
|
||||
SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate ------ 100 100 000 - 0
|
||||
5 Reallocated_Sector_Ct ------ 100 100 000 - 0
|
||||
9 Power_On_Hours ------ 100 100 000 - 1617
|
||||
12 Power_Cycle_Count ------ 100 100 000 - 180
|
||||
160 Uncorrectable_Error_Cnt ------ 100 100 000 - 0
|
||||
161 Valid_Spare_Block_Cnt ------ 100 100 000 - 55
|
||||
163 Initial_Bad_Block_Count ------ 100 100 000 - 13
|
||||
164 Total_Erase_Count ------ 100 100 000 - 783951
|
||||
165 Max_Erase_Count ------ 100 100 000 - 806
|
||||
166 Min_Erase_Count ------ 100 100 000 - 705
|
||||
167 Average_Erase_Count ------ 100 100 000 - 762
|
||||
168 Max_Erase_Count_of_Spec ------ 100 100 000 - 3000
|
||||
169 Remaining_Lifetime_Perc ------ 100 100 000 - 75
|
||||
175 Program_Fail_Count_Chip ------ 100 100 000 - 0
|
||||
176 Erase_Fail_Count_Chip ------ 100 100 000 - 0
|
||||
177 Wear_Leveling_Count ------ 100 100 050 - 1304
|
||||
178 Runtime_Invalid_Blk_Cnt ------ 100 100 000 - 0
|
||||
181 Program_Fail_Cnt_Total ------ 100 100 000 - 0
|
||||
182 Erase_Fail_Count_Total ------ 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count ------ 100 100 000 - 49
|
||||
194 Temperature_Celsius ------ 100 100 000 - 42
|
||||
195 Hardware_ECC_Recovered ------ 100 100 000 - 44
|
||||
196 Reallocated_Event_Count ------ 100 100 016 - 0
|
||||
197 Current_Pending_Sector ------ 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ------ 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count ------ 100 100 050 - 0
|
||||
232 Available_Reservd_Space ------ 100 100 000 - 100
|
||||
241 Host_Writes_32MiB ------ 100 100 000 - 378716
|
||||
242 Host_Reads_32MiB ------ 100 100 000 - 2715
|
||||
245 TLC_Writes_32MiB ------ 100 100 000 - 783951
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 GPL,SL R/O 1 Summary SMART error log
|
||||
0x02 GPL,SL R/O 1 Comprehensive SMART error log
|
||||
0x03 GPL,SL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 GPL,SL R/O 1 SMART self-test log
|
||||
0x07 GPL,SL R/O 1 Extended self-test log
|
||||
0x09 GPL,SL R/W 1 Selective self-test log
|
||||
0x10 GPL,SL R/O 1 NCQ Command Error log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
6 0 65535 Read_scanning was never started
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Commands not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 180 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 1617 --- Power-on Hours
|
||||
0x01 0x018 6 3344726241 --- Logical Sectors Written
|
||||
0x01 0x020 6 443470539 --- Number of Write Commands
|
||||
0x01 0x028 6 177964357 --- Logical Sectors Read
|
||||
0x01 0x030 6 5589057 --- Number of Read Commands
|
||||
0x02 ===== = = === == Free-Fall Statistics (empty) ==
|
||||
0x03 ===== = = === == Rotating Media Statistics (empty) ==
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 49 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (empty) ==
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 15111 --- Number of Hardware Resets
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 25 --- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11) not supported
|
||||
|
176
SSD/Transcend/TS32/TS32GMSA740/613B7F084954
Normal file
176
SSD/Transcend/TS32/TS32GMSA740/613B7F084954
Normal file
@@ -0,0 +1,176 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: JMicron/Maxiotek based SSDs
|
||||
Device Model: TS32GMSA740
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000000 ...
|
||||
Firmware Version: SVN167d
|
||||
User Capacity: 32,017,047,552 bytes [32.0 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
Form Factor: < 1.8 inches
|
||||
TRIM Command: Available
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Thu Aug 11 17:15:00 2022 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 254 (maximum performance)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x02) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 32) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
SCT capabilities: (0x0039) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate -O-R-- 100 100 000 - 0
|
||||
2 Throughput_Performance P-S--- 100 100 050 - 0
|
||||
3 Unknown_JMF_Attribute POS--- 100 100 050 - 0
|
||||
5 Reallocated_Sector_Ct PO--C- 100 100 050 - 0
|
||||
7 Unknown_JMF_Attribute PO-R-- 100 100 050 - 0
|
||||
8 Unknown_JMF_Attribute P-S--- 100 100 050 - 0
|
||||
9 Power_On_Hours -O--C- 100 100 000 - 41458
|
||||
10 Unknown_JMF_Attribute PO--C- 100 100 050 - 0
|
||||
12 Power_Cycle_Count -O--C- 100 100 000 - 70
|
||||
167 Unknown_JMF_Attribute -O---K 100 100 000 - 0
|
||||
168 SATA_Phy_Error_Count -O--C- 100 100 000 - 211
|
||||
169 Unknown_JMF_Attribute PO--C- 100 100 010 - 0
|
||||
170 Bad_Block_Count PO--C- 100 100 010 - 0 0 0
|
||||
173 Erase_Count -O--C- 176 176 000 - 0 0 0
|
||||
175 Bad_Cluster_Table_Count PO--C- 100 100 010 - 0
|
||||
192 Unexpect_Power_Loss_Ct -O--C- 100 100 000 - 28
|
||||
194 Temperature_Celsius -O---K 059 059 030 - 41 (Min/Max 29/42)
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
240 Unknown_JMF_Attribute PO--C- 100 100 050 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 51 Comprehensive SMART error log
|
||||
0x03 GPL R/O 64 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (64 sectors)
|
||||
Invalid Error Log index = 0x0000 (reserved = 0x00)
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 0 Celsius
|
||||
Power Cycle Min/Max Temperature: --/ 0 Celsius
|
||||
Lifetime Min/Max Temperature: --/ 0 Celsius
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: -127/127 Celsius
|
||||
Min/Max Temperature Limit: -127/127 Celsius
|
||||
Temperature History Size (Index): 478 (50)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 70 (7.0 seconds)
|
||||
Write: 70 (7.0 seconds)
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 70 --- Lifetime Power-On Resets
|
||||
0x01 0x018 6 20876177231 --- Logical Sectors Written
|
||||
0x01 0x020 6 340169537 --- Number of Write Commands
|
||||
0x01 0x028 6 954692456 --- Logical Sectors Read
|
||||
0x01 0x030 6 25253510 --- Number of Read Commands
|
||||
0x01 0x038 6 149248800000 --- Date and Time TimeStamp
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 23 N-- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 211 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 4 0 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 4 61 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC
|
||||
|
162
SSD/Transcend/TS32/TS32GMTS400S/190B8135FE3B
Normal file
162
SSD/Transcend/TS32/TS32GMTS400S/190B8135FE3B
Normal file
@@ -0,0 +1,162 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p3 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Silicon Motion based SSDs
|
||||
Device Model: TS32GMTS400S
|
||||
Serial Number: --
|
||||
Firmware Version: P1225CH1
|
||||
User Capacity: 32,017,047,552 bytes [32.0 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Sat Nov 19 04:53:39 2022 UTC
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x80) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 249) Self-test routine in progress...
|
||||
90% of test remaining.
|
||||
Total time to complete Offline
|
||||
data collection: ( 60) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x71) SMART execute Offline immediate.
|
||||
No Auto Offline data collection support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0002) Does not save SMART data before
|
||||
entering power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
|
||||
SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate ------ 100 100 000 - 0
|
||||
5 Reallocated_Sector_Ct ------ 100 100 000 - 0
|
||||
9 Power_On_Hours ------ 100 100 000 - 19599
|
||||
12 Power_Cycle_Count ------ 100 100 000 - 52
|
||||
160 Uncorrectable_Error_Cnt ------ 100 100 000 - 0
|
||||
161 Valid_Spare_Block_Cnt ------ 100 100 000 - 44
|
||||
163 Initial_Bad_Block_Count ------ 100 100 000 - 24
|
||||
164 Total_Erase_Count ------ 100 100 000 - 7455948
|
||||
165 Max_Erase_Count ------ 100 100 000 - 7387
|
||||
166 Min_Erase_Count ------ 100 100 000 - 7285
|
||||
167 Average_Erase_Count ------ 100 100 000 - 7331
|
||||
168 Max_Erase_Count_of_Spec ------ 100 100 000 - 3000
|
||||
169 Remaining_Lifetime_Perc ------ 100 100 000 - 0
|
||||
175 Program_Fail_Count_Chip ------ 100 100 000 - 0
|
||||
176 Erase_Fail_Count_Chip ------ 100 100 000 - 0
|
||||
177 Wear_Leveling_Count ------ 100 100 050 - 51086
|
||||
178 Runtime_Invalid_Blk_Cnt ------ 100 100 000 - 0
|
||||
181 Program_Fail_Cnt_Total ------ 100 100 000 - 0
|
||||
182 Erase_Fail_Count_Total ------ 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count ------ 100 100 000 - 25
|
||||
194 Temperature_Celsius ------ 100 100 000 - 49
|
||||
195 Hardware_ECC_Recovered ------ 100 100 000 - 0
|
||||
196 Reallocated_Event_Count ------ 100 100 016 - 0
|
||||
197 Current_Pending_Sector ------ 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ------ 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count ------ 100 100 050 - 0
|
||||
232 Available_Reservd_Space ------ 100 100 000 - 100
|
||||
241 Host_Writes_32MiB ------ 100 100 000 - 6458831
|
||||
242 Host_Reads_32MiB ------ 100 100 000 - 11586810
|
||||
245 TLC_Writes_32MiB ------ 100 100 000 - 7455948
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 GPL,SL R/O 1 Summary SMART error log
|
||||
0x02 GPL,SL R/O 1 Comprehensive SMART error log
|
||||
0x03 GPL,SL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 GPL,SL R/O 1 SMART self-test log
|
||||
0x07 GPL,SL R/O 1 Extended self-test log
|
||||
0x09 GPL,SL R/W 1 Selective self-test log
|
||||
0x10 GPL,SL R/O 1 NCQ Command Error log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Abort offline test Completed without error 00% 0 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
6 0 65535 Read_scanning was never started
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Commands not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 52 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 19599 --- Power-on Hours
|
||||
0x01 0x018 6 423285954548 --- Logical Sectors Written
|
||||
0x01 0x020 6 12225540077 --- Number of Write Commands
|
||||
0x01 0x028 6 759353235842 --- Logical Sectors Read
|
||||
0x01 0x030 6 60989791430 --- Number of Read Commands
|
||||
0x02 ===== = = === == Free-Fall Statistics (empty) ==
|
||||
0x03 ===== = = === == Rotating Media Statistics (empty) ==
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 25 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (empty) ==
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 590 --- Number of Hardware Resets
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 244 --- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11) not supported
|
||||
|
163
SSD/Transcend/TS32/TS32GMTS400S/B9E53F2EC57B
Normal file
163
SSD/Transcend/TS32/TS32GMTS400S/B9E53F2EC57B
Normal file
@@ -0,0 +1,163 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p5 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Silicon Motion based SSDs
|
||||
Device Model: TS32GMTS400S
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 7c3548 ...
|
||||
Firmware Version: S0903D
|
||||
User Capacity: 32,017,047,552 bytes [32.0 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Wed Jan 11 09:35:56 2023 CET
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x71) SMART execute Offline immediate.
|
||||
No Auto Offline data collection support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0002) Does not save SMART data before
|
||||
entering power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
|
||||
SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate ------ 100 100 000 - 0
|
||||
5 Reallocated_Sector_Ct ------ 100 100 010 - 0
|
||||
9 Power_On_Hours ------ 100 100 000 - 412
|
||||
12 Power_Cycle_Count ------ 100 100 000 - 100
|
||||
160 Uncorrectable_Error_Cnt ------ 100 100 000 - 0
|
||||
161 Valid_Spare_Block_Cnt ------ 100 100 012 - 27
|
||||
163 Initial_Bad_Block_Count ------ 100 100 000 - 5
|
||||
164 Total_Erase_Count ------ 100 100 000 - 75356
|
||||
165 Max_Erase_Count ------ 100 100 000 - 160
|
||||
166 Min_Erase_Count ------ 100 100 000 - 60
|
||||
167 Average_Erase_Count ------ 100 100 027 - 114
|
||||
168 Max_Erase_Count_of_Spec ------ 100 100 000 - 3000
|
||||
169 Remaining_Lifetime_Perc ------ 100 100 000 - 97
|
||||
175 Program_Fail_Count_Chip ------ 100 100 000 - 0
|
||||
176 Erase_Fail_Count_Chip ------ 100 100 000 - 0
|
||||
177 Wear_Leveling_Count ------ 100 100 000 - 33
|
||||
178 Runtime_Invalid_Blk_Cnt ------ 100 100 000 - 0
|
||||
181 Program_Fail_Cnt_Total ------ 100 100 000 - 0
|
||||
182 Erase_Fail_Count_Total ------ 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count ------ 100 100 000 - 62
|
||||
194 Temperature_Celsius ------ 100 100 000 - 19
|
||||
195 Hardware_ECC_Recovered ------ 100 100 000 - 1036490
|
||||
196 Reallocated_Event_Count ------ 100 100 000 - 0
|
||||
197 Current_Pending_Sector ------ 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ------ 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count ------ 100 100 000 - 0
|
||||
232 Available_Reservd_Space ------ 100 100 000 - 100
|
||||
241 Host_Writes_32MiB ------ 100 100 000 - 102360
|
||||
242 Host_Reads_32MiB ------ 100 100 000 - 1719
|
||||
245 TLC_Writes_32MiB ------ 100 100 000 - 116566
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 GPL,SL R/O 1 Summary SMART error log
|
||||
0x02 GPL,SL R/O 1 Comprehensive SMART error log
|
||||
0x03 GPL,SL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 GPL,SL R/O 1 SMART self-test log
|
||||
0x07 GPL,SL R/O 1 Extended self-test log
|
||||
0x09 GPL,SL R/W 1 Selective self-test log
|
||||
0x10 GPL,SL R/O 1 NCQ Command Error log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
6 0 65535 Read_scanning was never started
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Commands not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 100 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 412 --- Power-on Hours
|
||||
0x01 0x018 6 6708318062 --- Logical Sectors Written
|
||||
0x01 0x020 6 83460985 --- Number of Write Commands
|
||||
0x01 0x028 6 112705114 --- Logical Sectors Read
|
||||
0x01 0x030 6 1691906 --- Number of Read Commands
|
||||
0x02 ===== = = === == Free-Fall Statistics (empty) ==
|
||||
0x03 ===== = = === == Rotating Media Statistics (empty) ==
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 62 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (empty) ==
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 5328 --- Number of Hardware Resets
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 3 --- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11) not supported
|
||||
|
161
SSD/Transcend/TS32/TS32GMTS600/8431EA08E912
Normal file
161
SSD/Transcend/TS32/TS32GMTS600/8431EA08E912
Normal file
@@ -0,0 +1,161 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.0-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Device Model: TS32GMTS600
|
||||
Serial Number: --
|
||||
Firmware Version: O0918B
|
||||
User Capacity: 32,017,047,552 bytes [32.0 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
TRIM Command: Available, deterministic, zeroed
|
||||
Device is: Not in smartctl database 7.3/5319
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sun Apr 10 11:56:35 2022 EDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x71) SMART execute Offline immediate.
|
||||
No Auto Offline data collection support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0002) Does not save SMART data before
|
||||
entering power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
|
||||
SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate ------ 100 100 000 - 0
|
||||
5 Reallocated_Sector_Ct ------ 100 100 000 - 0
|
||||
9 Power_On_Hours ------ 100 100 000 - 3
|
||||
12 Power_Cycle_Count ------ 100 100 000 - 38
|
||||
160 Unknown_Attribute ------ 100 100 000 - 0
|
||||
161 Unknown_Attribute ------ 100 100 000 - 43
|
||||
163 Unknown_Attribute ------ 100 100 000 - 25
|
||||
164 Unknown_Attribute ------ 100 100 000 - 892
|
||||
165 Unknown_Attribute ------ 100 100 000 - 6
|
||||
166 Unknown_Attribute ------ 100 100 000 - 0
|
||||
167 Unknown_Attribute ------ 100 100 000 - 0
|
||||
168 Unknown_Attribute ------ 100 100 000 - 3000
|
||||
169 Unknown_Attribute ------ 100 100 000 - 100
|
||||
175 Program_Fail_Count_Chip ------ 100 100 000 - 0
|
||||
176 Erase_Fail_Count_Chip ------ 100 100 000 - 0
|
||||
177 Wear_Leveling_Count ------ 100 100 050 - 0
|
||||
178 Used_Rsvd_Blk_Cnt_Chip ------ 100 100 000 - 0
|
||||
181 Program_Fail_Cnt_Total ------ 100 100 000 - 0
|
||||
182 Erase_Fail_Count_Total ------ 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count ------ 100 100 000 - 4
|
||||
194 Temperature_Celsius ------ 100 100 000 - 42
|
||||
195 Hardware_ECC_Recovered ------ 100 100 000 - 82
|
||||
196 Reallocated_Event_Count ------ 100 100 016 - 0
|
||||
197 Current_Pending_Sector ------ 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ------ 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count ------ 100 100 050 - 0
|
||||
232 Available_Reservd_Space ------ 100 100 000 - 100
|
||||
241 Total_LBAs_Written ------ 100 100 000 - 593
|
||||
242 Total_LBAs_Read ------ 100 100 000 - 620
|
||||
245 Unknown_Attribute ------ 100 100 000 - 892
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 GPL,SL R/O 1 Summary SMART error log
|
||||
0x02 GPL,SL R/O 1 Comprehensive SMART error log
|
||||
0x03 GPL,SL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 GPL,SL R/O 1 SMART self-test log
|
||||
0x07 GPL,SL R/O 1 Extended self-test log
|
||||
0x09 GPL,SL R/W 1 Selective self-test log
|
||||
0x10 GPL,SL R/O 1 NCQ Command Error log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
6 0 65535 Read_scanning was never started
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Commands not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 38 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 3 --- Power-on Hours
|
||||
0x01 0x018 6 38923716 --- Logical Sectors Written
|
||||
0x01 0x020 6 455473 --- Number of Write Commands
|
||||
0x01 0x028 6 40659571 --- Logical Sectors Read
|
||||
0x01 0x030 6 396036 --- Number of Read Commands
|
||||
0x02 ===== = = === == Free-Fall Statistics (empty) ==
|
||||
0x03 ===== = = === == Rotating Media Statistics (empty) ==
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 4 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (empty) ==
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 54 --- Number of Hardware Resets
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 0 --- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11) not supported
|
||||
|
165
SSD/Transcend/TS32/TS32GMTS800/B6CA50E8C683
Normal file
165
SSD/Transcend/TS32/TS32GMTS800/B6CA50E8C683
Normal file
@@ -0,0 +1,165 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p3 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Silicon Motion based SSDs
|
||||
Device Model: TS32GMTS800
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 7c3548 ...
|
||||
Firmware Version: O0918B
|
||||
User Capacity: 32,017,047,552 bytes [32.0 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sun Nov 6 16:16:01 2022 MST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x71) SMART execute Offline immediate.
|
||||
No Auto Offline data collection support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0002) Does not save SMART data before
|
||||
entering power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
|
||||
SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate ------ 100 100 000 - 0
|
||||
5 Reallocated_Sector_Ct ------ 100 100 000 - 0
|
||||
9 Power_On_Hours ------ 100 100 000 - 193
|
||||
12 Power_Cycle_Count ------ 100 100 000 - 88
|
||||
160 Uncorrectable_Error_Cnt ------ 100 100 000 - 0
|
||||
161 Valid_Spare_Block_Cnt ------ 100 100 000 - 53
|
||||
163 Initial_Bad_Block_Count ------ 100 100 000 - 15
|
||||
164 Total_Erase_Count ------ 100 100 000 - 10322
|
||||
165 Max_Erase_Count ------ 100 100 000 - 30
|
||||
166 Min_Erase_Count ------ 100 100 000 - 0
|
||||
167 Average_Erase_Count ------ 100 100 000 - 10
|
||||
168 Max_Erase_Count_of_Spec ------ 100 100 000 - 3000
|
||||
169 Remaining_Lifetime_Perc ------ 100 100 000 - 100
|
||||
175 Program_Fail_Count_Chip ------ 100 100 000 - 0
|
||||
176 Erase_Fail_Count_Chip ------ 100 100 000 - 0
|
||||
177 Wear_Leveling_Count ------ 100 100 050 - 0
|
||||
178 Runtime_Invalid_Blk_Cnt ------ 100 100 000 - 0
|
||||
181 Program_Fail_Cnt_Total ------ 100 100 000 - 0
|
||||
182 Erase_Fail_Count_Total ------ 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count ------ 100 100 000 - 18
|
||||
194 Temperature_Celsius ------ 100 100 000 - 14
|
||||
195 Hardware_ECC_Recovered ------ 100 100 000 - 32
|
||||
196 Reallocated_Event_Count ------ 100 100 016 - 0
|
||||
197 Current_Pending_Sector ------ 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ------ 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count ------ 100 100 050 - 0
|
||||
232 Available_Reservd_Space ------ 100 100 000 - 100
|
||||
241 Host_Writes_32MiB ------ 100 100 000 - 3809
|
||||
242 Host_Reads_32MiB ------ 100 100 000 - 1439
|
||||
245 TLC_Writes_32MiB ------ 100 100 000 - 10322
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 GPL,SL R/O 1 Summary SMART error log
|
||||
0x02 GPL,SL R/O 1 Comprehensive SMART error log
|
||||
0x03 GPL,SL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 GPL,SL R/O 1 SMART self-test log
|
||||
0x07 GPL,SL R/O 1 Extended self-test log
|
||||
0x09 GPL,SL R/W 1 Selective self-test log
|
||||
0x10 GPL,SL R/O 1 NCQ Command Error log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
6 0 65535 Read_scanning was never started
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Commands not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 88 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 193 --- Power-on Hours
|
||||
0x01 0x018 6 249680636 --- Logical Sectors Written
|
||||
0x01 0x020 6 5889203 --- Number of Write Commands
|
||||
0x01 0x028 6 94356387 --- Logical Sectors Read
|
||||
0x01 0x030 6 1796205 --- Number of Read Commands
|
||||
0x02 ===== = = === == Free-Fall Statistics (empty) ==
|
||||
0x03 ===== = = === == Rotating Media Statistics (empty) ==
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 18 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (empty) ==
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 297 --- Number of Hardware Resets
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 0 --- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11) not supported
|
||||
|
||||
|
||||
|
165
SSD/Transcend/TS32/TS32GMTS800/CFE2823A3C90
Normal file
165
SSD/Transcend/TS32/TS32GMTS800/CFE2823A3C90
Normal file
@@ -0,0 +1,165 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p3 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Silicon Motion based SSDs
|
||||
Device Model: TS32GMTS800
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 7c3548 ...
|
||||
Firmware Version: P1225CH1
|
||||
User Capacity: 32,017,047,552 bytes [32.0 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sun Nov 6 16:16:01 2022 MST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x05) Offline data collection activity
|
||||
was aborted by an interrupting command from host.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 16) The self-test routine was aborted by
|
||||
the host.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x71) SMART execute Offline immediate.
|
||||
No Auto Offline data collection support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0002) Does not save SMART data before
|
||||
entering power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
|
||||
SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate ------ 100 100 000 - 0
|
||||
5 Reallocated_Sector_Ct ------ 100 100 000 - 0
|
||||
9 Power_On_Hours ------ 100 100 000 - 191
|
||||
12 Power_Cycle_Count ------ 100 100 000 - 75
|
||||
160 Uncorrectable_Error_Cnt ------ 100 100 000 - 0
|
||||
161 Valid_Spare_Block_Cnt ------ 100 100 000 - 160
|
||||
163 Initial_Bad_Block_Count ------ 100 100 000 - 4
|
||||
164 Total_Erase_Count ------ 100 100 000 - 15942
|
||||
165 Max_Erase_Count ------ 100 100 000 - 24
|
||||
166 Min_Erase_Count ------ 100 100 000 - 0
|
||||
167 Average_Erase_Count ------ 100 100 000 - 7
|
||||
168 Max_Erase_Count_of_Spec ------ 100 100 000 - 3000
|
||||
169 Remaining_Lifetime_Perc ------ 100 100 000 - 100
|
||||
175 Program_Fail_Count_Chip ------ 100 100 000 - 0
|
||||
176 Erase_Fail_Count_Chip ------ 100 100 000 - 0
|
||||
177 Wear_Leveling_Count ------ 100 100 050 - 0
|
||||
178 Runtime_Invalid_Blk_Cnt ------ 100 100 000 - 0
|
||||
181 Program_Fail_Cnt_Total ------ 100 100 000 - 0
|
||||
182 Erase_Fail_Count_Total ------ 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count ------ 100 100 000 - 16
|
||||
194 Temperature_Celsius ------ 100 100 000 - 14
|
||||
195 Hardware_ECC_Recovered ------ 100 100 000 - 0
|
||||
196 Reallocated_Event_Count ------ 100 100 016 - 0
|
||||
197 Current_Pending_Sector ------ 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ------ 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count ------ 100 100 050 - 0
|
||||
232 Available_Reservd_Space ------ 100 100 000 - 100
|
||||
241 Host_Writes_32MiB ------ 100 100 000 - 2685
|
||||
242 Host_Reads_32MiB ------ 100 100 000 - 92
|
||||
245 TLC_Writes_32MiB ------ 100 100 000 - 7971
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 GPL,SL R/O 1 Summary SMART error log
|
||||
0x02 GPL,SL R/O 1 Comprehensive SMART error log
|
||||
0x03 GPL,SL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 GPL,SL R/O 1 SMART self-test log
|
||||
0x07 GPL,SL R/O 1 Extended self-test log
|
||||
0x09 GPL,SL R/W 1 Selective self-test log
|
||||
0x10 GPL,SL R/O 1 NCQ Command Error log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Abort offline test Completed without error 00% 139 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
6 0 65535 Read_scanning was aborted by an interrupting command from host
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Commands not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 75 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 191 --- Power-on Hours
|
||||
0x01 0x018 6 175988926 --- Logical Sectors Written
|
||||
0x01 0x020 6 5366703 --- Number of Write Commands
|
||||
0x01 0x028 6 6064392 --- Logical Sectors Read
|
||||
0x01 0x030 6 127115 --- Number of Read Commands
|
||||
0x02 ===== = = === == Free-Fall Statistics (empty) ==
|
||||
0x03 ===== = = === == Rotating Media Statistics (empty) ==
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 16 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (empty) ==
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 272 --- Number of Hardware Resets
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 0 --- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11) not supported
|
||||
|
||||
|
||||
|
163
SSD/Transcend/TS32/TS32GMTS800/D64E0537CDAD
Normal file
163
SSD/Transcend/TS32/TS32GMTS800/D64E0537CDAD
Normal file
@@ -0,0 +1,163 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p3 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Silicon Motion based SSDs
|
||||
Device Model: TS32GMTS800
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 7c3548 ...
|
||||
Firmware Version: O0918B
|
||||
User Capacity: 32,017,047,552 bytes [32.0 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sun Nov 6 16:16:01 2022 MST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x71) SMART execute Offline immediate.
|
||||
No Auto Offline data collection support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0002) Does not save SMART data before
|
||||
entering power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
|
||||
SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate ------ 100 100 000 - 0
|
||||
5 Reallocated_Sector_Ct ------ 100 100 000 - 0
|
||||
9 Power_On_Hours ------ 100 100 000 - 193
|
||||
12 Power_Cycle_Count ------ 100 100 000 - 97
|
||||
160 Uncorrectable_Error_Cnt ------ 100 100 000 - 0
|
||||
161 Valid_Spare_Block_Cnt ------ 100 100 000 - 48
|
||||
163 Initial_Bad_Block_Count ------ 100 100 000 - 20
|
||||
164 Total_Erase_Count ------ 100 100 000 - 10264
|
||||
165 Max_Erase_Count ------ 100 100 000 - 32
|
||||
166 Min_Erase_Count ------ 100 100 000 - 0
|
||||
167 Average_Erase_Count ------ 100 100 000 - 10
|
||||
168 Max_Erase_Count_of_Spec ------ 100 100 000 - 3000
|
||||
169 Remaining_Lifetime_Perc ------ 100 100 000 - 100
|
||||
175 Program_Fail_Count_Chip ------ 100 100 000 - 0
|
||||
176 Erase_Fail_Count_Chip ------ 100 100 000 - 0
|
||||
177 Wear_Leveling_Count ------ 100 100 050 - 0
|
||||
178 Runtime_Invalid_Blk_Cnt ------ 100 100 000 - 0
|
||||
181 Program_Fail_Cnt_Total ------ 100 100 000 - 0
|
||||
182 Erase_Fail_Count_Total ------ 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count ------ 100 100 000 - 18
|
||||
194 Temperature_Celsius ------ 100 100 000 - 14
|
||||
195 Hardware_ECC_Recovered ------ 100 100 000 - 29
|
||||
196 Reallocated_Event_Count ------ 100 100 016 - 0
|
||||
197 Current_Pending_Sector ------ 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ------ 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count ------ 100 100 050 - 0
|
||||
232 Available_Reservd_Space ------ 100 100 000 - 100
|
||||
241 Host_Writes_32MiB ------ 100 100 000 - 3809
|
||||
242 Host_Reads_32MiB ------ 100 100 000 - 1442
|
||||
245 TLC_Writes_32MiB ------ 100 100 000 - 10264
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 GPL,SL R/O 1 Summary SMART error log
|
||||
0x02 GPL,SL R/O 1 Comprehensive SMART error log
|
||||
0x03 GPL,SL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 GPL,SL R/O 1 SMART self-test log
|
||||
0x07 GPL,SL R/O 1 Extended self-test log
|
||||
0x09 GPL,SL R/W 1 Selective self-test log
|
||||
0x10 GPL,SL R/O 1 NCQ Command Error log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
6 0 65535 Read_scanning was never started
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Commands not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 97 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 193 --- Power-on Hours
|
||||
0x01 0x018 6 249648858 --- Logical Sectors Written
|
||||
0x01 0x020 6 5868436 --- Number of Write Commands
|
||||
0x01 0x028 6 94564109 --- Logical Sectors Read
|
||||
0x01 0x030 6 1796908 --- Number of Read Commands
|
||||
0x02 ===== = = === == Free-Fall Statistics (empty) ==
|
||||
0x03 ===== = = === == Rotating Media Statistics (empty) ==
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 18 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (empty) ==
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 302 --- Number of Hardware Resets
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 0 --- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11) not supported
|
||||
|
167
SSD/Transcend/TS32/TS32GSSD370S/2F037890F1A7
Normal file
167
SSD/Transcend/TS32/TS32GSSD370S/2F037890F1A7
Normal file
@@ -0,0 +1,167 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p5 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Silicon Motion based SSDs
|
||||
Device Model: TS32GSSD370S
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 7c3548 ...
|
||||
Firmware Version: S0903D
|
||||
User Capacity: 32,017,047,552 bytes [32.0 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Tue Dec 27 22:57:43 2022 CET
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: FAILED!
|
||||
Drive failure expected in less than 24 hours. SAVE ALL DATA.
|
||||
No failed Attributes found.
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x02) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x71) SMART execute Offline immediate.
|
||||
No Auto Offline data collection support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0002) Does not save SMART data before
|
||||
entering power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
|
||||
SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate ------ 100 100 000 - 0
|
||||
5 Reallocated_Sector_Ct ------ 100 100 010 - 0
|
||||
9 Power_On_Hours ------ 100 100 000 - 2273
|
||||
12 Power_Cycle_Count ------ 100 100 000 - 54
|
||||
160 Uncorrectable_Error_Cnt ------ 100 100 000 - 0
|
||||
161 Valid_Spare_Block_Cnt ------ 100 100 012 - 23
|
||||
163 Initial_Bad_Block_Count ------ 100 100 000 - 9
|
||||
164 Total_Erase_Count ------ 100 100 000 - 2307528
|
||||
165 Max_Erase_Count ------ 100 100 000 - 3564
|
||||
166 Min_Erase_Count ------ 100 100 000 - 3463
|
||||
167 Average_Erase_Count ------ 100 100 027 - 3512
|
||||
168 Max_Erase_Count_of_Spec ------ 100 100 000 - 3000
|
||||
169 Remaining_Lifetime_Perc ------ 100 100 000 - 0
|
||||
175 Program_Fail_Count_Chip ------ 100 100 000 - 0
|
||||
176 Erase_Fail_Count_Chip ------ 100 100 000 - 0
|
||||
177 Wear_Leveling_Count ------ 100 100 000 - 9711
|
||||
178 Runtime_Invalid_Blk_Cnt ------ 100 100 000 - 0
|
||||
181 Program_Fail_Cnt_Total ------ 100 100 000 - 0
|
||||
182 Erase_Fail_Count_Total ------ 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count ------ 100 100 000 - 6
|
||||
194 Temperature_Celsius ------ 100 100 000 - 46
|
||||
195 Hardware_ECC_Recovered ------ 100 100 000 - 4647
|
||||
196 Reallocated_Event_Count ------ 100 100 000 - 0
|
||||
197 Current_Pending_Sector ------ 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ------ 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count ------ 100 100 000 - 0
|
||||
232 Available_Reservd_Space ------ 100 100 000 - 100
|
||||
241 Host_Writes_32MiB ------ 100 100 000 - 2707369
|
||||
242 Host_Reads_32MiB ------ 100 100 000 - 33343
|
||||
245 TLC_Writes_32MiB ------ 100 100 000 - 3569457
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 GPL,SL R/O 1 Summary SMART error log
|
||||
0x02 GPL,SL R/O 1 Comprehensive SMART error log
|
||||
0x03 GPL,SL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 GPL,SL R/O 1 SMART self-test log
|
||||
0x07 GPL,SL R/O 1 Extended self-test log
|
||||
0x09 GPL,SL R/W 1 Selective self-test log
|
||||
0x10 GPL,SL R/O 1 NCQ Command Error log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 0 -
|
||||
# 2 Short offline Completed without error 00% 0 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
7 0 65535 Read_scanning was completed without error
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Commands not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 54 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 2273 --- Power-on Hours
|
||||
0x01 0x018 6 177430154247 --- Logical Sectors Written
|
||||
0x01 0x020 6 2090892188 --- Number of Write Commands
|
||||
0x01 0x028 6 2185211650 --- Logical Sectors Read
|
||||
0x01 0x030 6 27527472 --- Number of Read Commands
|
||||
0x02 ===== = = === == Free-Fall Statistics (empty) ==
|
||||
0x03 ===== = = === == Rotating Media Statistics (empty) ==
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 6 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (empty) ==
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 284 --- Number of Hardware Resets
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 117 --- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11) not supported
|
||||
|
165
SSD/Transcend/TS32/TS32GSSD370S/55ED61FA82CC
Normal file
165
SSD/Transcend/TS32/TS32GSSD370S/55ED61FA82CC
Normal file
@@ -0,0 +1,165 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p2 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Silicon Motion based SSDs
|
||||
Device Model: TS32GSSD370S
|
||||
Serial Number: --
|
||||
Firmware Version: O0918B
|
||||
User Capacity: 32,017,047,552 bytes [32.0 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Mon Sep 19 14:34:13 2022 MST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x02) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 57) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x71) SMART execute Offline immediate.
|
||||
No Auto Offline data collection support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0002) Does not save SMART data before
|
||||
entering power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
|
||||
SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate ------ 100 100 000 - 0
|
||||
5 Reallocated_Sector_Ct ------ 100 100 000 - 0
|
||||
9 Power_On_Hours ------ 100 100 000 - 824
|
||||
12 Power_Cycle_Count ------ 100 100 000 - 275
|
||||
160 Uncorrectable_Error_Cnt ------ 100 100 000 - 0
|
||||
161 Valid_Spare_Block_Cnt ------ 100 100 000 - 55
|
||||
163 Initial_Bad_Block_Count ------ 100 100 000 - 13
|
||||
164 Total_Erase_Count ------ 100 100 000 - 1482070
|
||||
165 Max_Erase_Count ------ 100 100 000 - 1494
|
||||
166 Min_Erase_Count ------ 100 100 000 - 1392
|
||||
167 Average_Erase_Count ------ 100 100 000 - 1441
|
||||
168 Max_Erase_Count_of_Spec ------ 100 100 000 - 3000
|
||||
169 Remaining_Lifetime_Perc ------ 100 100 000 - 52
|
||||
175 Program_Fail_Count_Chip ------ 100 100 000 - 0
|
||||
176 Erase_Fail_Count_Chip ------ 100 100 000 - 0
|
||||
177 Wear_Leveling_Count ------ 100 100 050 - 7799
|
||||
178 Runtime_Invalid_Blk_Cnt ------ 100 100 000 - 0
|
||||
181 Program_Fail_Cnt_Total ------ 100 100 000 - 0
|
||||
182 Erase_Fail_Count_Total ------ 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count ------ 100 100 000 - 18
|
||||
194 Temperature_Celsius ------ 100 100 000 - 39
|
||||
195 Hardware_ECC_Recovered ------ 100 100 000 - 0
|
||||
196 Reallocated_Event_Count ------ 100 100 016 - 0
|
||||
197 Current_Pending_Sector ------ 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ------ 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count ------ 100 100 050 - 0
|
||||
232 Available_Reservd_Space ------ 100 100 000 - 100
|
||||
241 Host_Writes_32MiB ------ 100 100 000 - 251710
|
||||
242 Host_Reads_32MiB ------ 100 100 000 - 18421
|
||||
245 TLC_Writes_32MiB ------ 100 100 000 - 1482070
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 GPL,SL R/O 1 Summary SMART error log
|
||||
0x02 GPL,SL R/O 1 Comprehensive SMART error log
|
||||
0x03 GPL,SL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 GPL,SL R/O 1 SMART self-test log
|
||||
0x07 GPL,SL R/O 1 Extended self-test log
|
||||
0x09 GPL,SL R/W 1 Selective self-test log
|
||||
0x10 GPL,SL R/O 1 NCQ Command Error log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 0 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
7 0 65535 Read_scanning was completed without error
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Commands not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 275 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 824 --- Power-on Hours
|
||||
0x01 0x018 6 3611210549 --- Logical Sectors Written
|
||||
0x01 0x020 6 366673410 --- Number of Write Commands
|
||||
0x01 0x028 6 1207269206 --- Logical Sectors Read
|
||||
0x01 0x030 6 14920690 --- Number of Read Commands
|
||||
0x02 ===== = = === == Free-Fall Statistics (empty) ==
|
||||
0x03 ===== = = === == Rotating Media Statistics (empty) ==
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 18 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (empty) ==
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 2798 --- Number of Hardware Resets
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 48 --- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11) not supported
|
||||
|
||||
|
||||
|
163
SSD/Transcend/TS32/TS32GSSD370S/F83DFFC8A8A0
Normal file
163
SSD/Transcend/TS32/TS32GSSD370S/F83DFFC8A8A0
Normal file
@@ -0,0 +1,163 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p2 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Silicon Motion based SSDs
|
||||
Device Model: TS32GSSD370S
|
||||
Serial Number: --
|
||||
Firmware Version: O0918B
|
||||
User Capacity: 32,017,047,552 bytes [32.0 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Mon Sep 19 14:34:13 2022 MST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x02) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 57) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x71) SMART execute Offline immediate.
|
||||
No Auto Offline data collection support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0002) Does not save SMART data before
|
||||
entering power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
|
||||
SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate ------ 100 100 000 - 0
|
||||
5 Reallocated_Sector_Ct ------ 100 100 000 - 0
|
||||
9 Power_On_Hours ------ 100 100 000 - 1072
|
||||
12 Power_Cycle_Count ------ 100 100 000 - 651
|
||||
160 Uncorrectable_Error_Cnt ------ 100 100 000 - 0
|
||||
161 Valid_Spare_Block_Cnt ------ 100 100 000 - 53
|
||||
163 Initial_Bad_Block_Count ------ 100 100 000 - 15
|
||||
164 Total_Erase_Count ------ 100 100 000 - 1557113
|
||||
165 Max_Erase_Count ------ 100 100 000 - 1569
|
||||
166 Min_Erase_Count ------ 100 100 000 - 1467
|
||||
167 Average_Erase_Count ------ 100 100 000 - 1517
|
||||
168 Max_Erase_Count_of_Spec ------ 100 100 000 - 3000
|
||||
169 Remaining_Lifetime_Perc ------ 100 100 000 - 50
|
||||
175 Program_Fail_Count_Chip ------ 100 100 000 - 0
|
||||
176 Erase_Fail_Count_Chip ------ 100 100 000 - 0
|
||||
177 Wear_Leveling_Count ------ 100 100 050 - 7819
|
||||
178 Runtime_Invalid_Blk_Cnt ------ 100 100 000 - 0
|
||||
181 Program_Fail_Cnt_Total ------ 100 100 000 - 0
|
||||
182 Erase_Fail_Count_Total ------ 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count ------ 100 100 000 - 150
|
||||
194 Temperature_Celsius ------ 100 100 000 - 42
|
||||
195 Hardware_ECC_Recovered ------ 100 100 000 - 30
|
||||
196 Reallocated_Event_Count ------ 100 100 016 - 0
|
||||
197 Current_Pending_Sector ------ 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ------ 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count ------ 100 100 050 - 0
|
||||
232 Available_Reservd_Space ------ 100 100 000 - 100
|
||||
241 Host_Writes_32MiB ------ 100 100 000 - 256487
|
||||
242 Host_Reads_32MiB ------ 100 100 000 - 24568
|
||||
245 TLC_Writes_32MiB ------ 100 100 000 - 1557113
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 GPL,SL R/O 1 Summary SMART error log
|
||||
0x02 GPL,SL R/O 1 Comprehensive SMART error log
|
||||
0x03 GPL,SL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 GPL,SL R/O 1 SMART self-test log
|
||||
0x07 GPL,SL R/O 1 Extended self-test log
|
||||
0x09 GPL,SL R/W 1 Selective self-test log
|
||||
0x10 GPL,SL R/O 1 NCQ Command Error log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 315 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
7 0 65535 Read_scanning was completed without error
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Commands not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 651 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 1072 --- Power-on Hours
|
||||
0x01 0x018 6 3924241445 --- Logical Sectors Written
|
||||
0x01 0x020 6 371830272 --- Number of Write Commands
|
||||
0x01 0x028 6 1610119344 --- Logical Sectors Read
|
||||
0x01 0x030 6 24260782 --- Number of Read Commands
|
||||
0x02 ===== = = === == Free-Fall Statistics (empty) ==
|
||||
0x03 ===== = = === == Rotating Media Statistics (empty) ==
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 150 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (empty) ==
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 5852 --- Number of Hardware Resets
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 50 --- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11) not supported
|
||||
|
Reference in New Issue