smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p7 i386] (local build)
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.2-RELEASE i386] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -10,7 +10,7 @@ User Capacity: 40,007,761,920 bytes [40.0 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA/ATAPI-6 T13/1410D revision 3a
|
||||
Local Time is: Thu Jul 9 18:42:21 2020 JST
|
||||
Local Time is: Sat Nov 14 02:57:20 2020 JST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM level is: 64 (unknown/retired), recommended: 0
|
||||
@@ -58,26 +58,26 @@ recommended polling time: ( 2) minutes.
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 100 100 046 - 30254
|
||||
1 Raw_Read_Error_Rate POSR-- 100 100 046 - 237067
|
||||
2 Throughput_Performance P-S--- 100 100 030 - 0
|
||||
3 Spin_Up_Time PO---- 097 076 025 - 24832
|
||||
4 Start_Stop_Count -O--CK 034 034 000 - 39602
|
||||
3 Spin_Up_Time PO---- 095 076 025 - 24064
|
||||
4 Start_Stop_Count -O--CK 034 034 000 - 39605
|
||||
5 Reallocated_Sector_Ct PO--CK 099 099 024 - 26
|
||||
7 Seek_Error_Rate POSR-- 100 081 047 - 2566
|
||||
7 Seek_Error_Rate POSR-- 100 081 047 - 3204
|
||||
8 Seek_Time_Performance P-S--- 100 100 019 - 0
|
||||
9 Power_On_Seconds -O--CK 001 001 000 - 32035h+36m+20s
|
||||
9 Power_On_Seconds -O--CK 001 001 000 - 32042h+13m+52s
|
||||
10 Spin_Retry_Count PO--C- 100 010 020 Past 0
|
||||
12 Power_Cycle_Count -O--CK 001 001 000 - 35055
|
||||
192 Emerg_Retract_Cycle_Ct -O--CK 098 098 000 - 399
|
||||
193 Load_Cycle_Count -O--CK 001 001 000 - 1480265
|
||||
194 Temperature_Celsius -O---K 100 040 000 - 42 (Min/Max 9/67)
|
||||
195 Hardware_ECC_Recovered -O-RC- 100 100 000 - 191
|
||||
12 Power_Cycle_Count -O--CK 001 001 000 - 35057
|
||||
192 Emerg_Retract_Cycle_Ct -O--CK 098 098 000 - 400
|
||||
193 Load_Cycle_Count -O--CK 001 001 000 - 1480596
|
||||
194 Temperature_Celsius -O---K 100 040 000 - 43 (Min/Max 9/67)
|
||||
195 Hardware_ECC_Recovered -O-RC- 100 100 000 - 3915
|
||||
196 Reallocated_Event_Count -O--CK 099 099 000 - 7
|
||||
197 Current_Pending_Sector -O--C- 100 090 000 - 0
|
||||
198 Offline_Scan_UNC_SectCt ----C- 097 097 000 - 6
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
200 Write_Error_Count POSR-- 100 100 060 - 23565
|
||||
203 Run_Out_Cancel -O---- 097 097 000 - 2619842430041
|
||||
200 Write_Error_Count POSR-- 100 100 060 - 2621
|
||||
203 Run_Out_Cancel -O---- 097 097 000 - 2619836072594
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p13-HBSD amd64] (local build)
|
||||
smartctl 7.2 2021-09-14 r5236 [FreeBSD 12.1-RELEASE-p21-HBSD amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -10,7 +10,7 @@ User Capacity: 79,925,045,760 bytes [79.9 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA/ATAPI-7 T13/1532D revision 1
|
||||
Local Time is: Thu Feb 25 22:57:03 2021 MSK
|
||||
Local Time is: Thu Dec 9 18:17:45 2021 MSK
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM level is: 254 (maximum performance), recommended: 254
|
||||
@@ -57,26 +57,26 @@ recommended polling time: ( 2) minutes.
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 100 100 046 - 157784
|
||||
1 Raw_Read_Error_Rate POSR-- 100 100 046 - 4295113924
|
||||
2 Throughput_Performance P-S--- 100 100 030 - 23789568
|
||||
3 Spin_Up_Time PO---- 100 100 025 - 1
|
||||
4 Start_Stop_Count -O--CK 098 098 000 - 5777
|
||||
4 Start_Stop_Count -O--CK 098 098 000 - 5793
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 024 - 0 (2000 0)
|
||||
7 Seek_Error_Rate POSR-- 100 100 047 - 1079
|
||||
7 Seek_Error_Rate POSR-- 100 100 047 - 409
|
||||
8 Seek_Time_Performance P-S--- 100 100 019 - 0
|
||||
9 Power_On_Seconds -O--CK 089 089 000 - 5796h+09m+25s
|
||||
9 Power_On_Seconds -O--CK 075 075 000 - 12606h+28m+00s
|
||||
10 Spin_Retry_Count PO--C- 100 100 020 - 0
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 5088
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 67
|
||||
193 Load_Cycle_Count -O--CK 091 091 000 - 90106
|
||||
194 Temperature_Celsius -O---K 100 100 000 - 34 (Min/Max 14/56)
|
||||
195 Hardware_ECC_Recovered -O-RC- 100 100 000 - 2418
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 5102
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 72
|
||||
193 Load_Cycle_Count -O--CK 058 058 000 - 429232
|
||||
194 Temperature_Celsius -O---K 100 100 000 - 26 (Min/Max 14/56)
|
||||
195 Hardware_ECC_Recovered -O-RC- 100 100 000 - 10262
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0 (0 6894)
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate POSR-- 100 100 060 - 26096
|
||||
203 Run_Out_Cancel -O---- 100 100 000 - 433730157478
|
||||
200 Multi_Zone_Error_Rate POSR-- 100 100 060 - 17868
|
||||
203 Run_Out_Cancel -O---- 100 100 000 - 433718491948
|
||||
240 Head_Flying_Hours -OSRCK 200 200 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
|
@@ -1,5 +1,5 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.2-RELEASE-p3 amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Fujitsu MJA BH
|
||||
@@ -12,7 +12,7 @@ Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 3f
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s
|
||||
Local Time is: Fri Jan 22 20:05:24 2021 EST
|
||||
Local Time is: Sun Jan 31 15:00:54 2021 GMT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM level is: 254 (maximum performance), recommended: 254
|
||||
@@ -63,26 +63,26 @@ SCT capabilities: (0x003d) SCT Status supported.
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 100 100 046 - 197277
|
||||
1 Raw_Read_Error_Rate POSR-- 100 100 046 - 203418
|
||||
2 Throughput_Performance P-S--- 100 100 030 - 47382528
|
||||
3 Spin_Up_Time PO---- 100 100 025 - 1
|
||||
4 Start_Stop_Count -O--CK 099 099 000 - 931
|
||||
3 Spin_Up_Time PO---- 100 100 025 - 0
|
||||
4 Start_Stop_Count -O--CK 099 099 000 - 949
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 024 - 0 (2100 0)
|
||||
7 Seek_Error_Rate POSR-- 100 100 047 - 2004
|
||||
7 Seek_Error_Rate POSR-- 100 100 047 - 3482
|
||||
8 Seek_Time_Performance P-S--- 100 100 019 - 0
|
||||
9 Power_On_Hours -O--CK 091 091 000 - 4507
|
||||
9 Power_On_Hours -O--CK 091 091 000 - 4668
|
||||
10 Spin_Retry_Count PO--C- 100 100 020 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 927
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 30
|
||||
193 Load_Cycle_Count -O--CK 097 097 000 - 71111
|
||||
194 Temperature_Celsius -O---K 100 100 000 - 30 (Min/Max 14/50)
|
||||
195 Hardware_ECC_Recovered -O-RC- 100 100 000 - 2571
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 945
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 33
|
||||
193 Load_Cycle_Count -O--CK 097 097 000 - 71179
|
||||
194 Temperature_Celsius -O---K 100 100 000 - 35 (Min/Max 14/50)
|
||||
195 Hardware_ECC_Recovered -O-RC- 100 100 000 - 2603
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0 (0 16094)
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 253 000 - 0
|
||||
200 Multi_Zone_Error_Rate POSR-- 100 100 060 - 19766
|
||||
203 Run_Out_Cancel -O---- 100 100 000 - 2628551967380
|
||||
200 Multi_Zone_Error_Rate POSR-- 100 100 060 - 1649
|
||||
203 Run_Out_Cancel -O---- 100 100 000 - 1529015238051
|
||||
240 Head_Flying_Hours -OSRCK 200 200 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
@@ -128,8 +128,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 0 (0x0000)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 30 Celsius
|
||||
Power Cycle Min/Max Temperature: 16/30 Celsius
|
||||
Current Temperature: 35 Celsius
|
||||
Power Cycle Min/Max Temperature: 34/35 Celsius
|
||||
Lifetime Min/Max Temperature: 14/50 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
@@ -138,7 +138,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 5/60 Celsius
|
||||
Min/Max Temperature Limit: -40/65 Celsius
|
||||
Temperature History Size (Index): 478 (256)
|
||||
Temperature History Size (Index): 478 (106)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -157,8 +157,8 @@ ID Size Value Description
|
||||
0x0005 4 0 R_ERR response for non-data FIS
|
||||
0x0006 4 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0008 4 0 Device-to-host non-data FIS retries
|
||||
0x0009 4 12 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 4 10 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 4 5 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 4 4 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 4 0 CRC errors within host-to-device FIS
|
||||
0x000d 4 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 4 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|
Reference in New Issue