mirror of
https://github.com/bsdhw/SMART.git
synced 2025-05-31 16:21:41 +05:30
Update of reports (new: 0, modified: 1434)
This commit is contained in:
@@ -1,5 +1,5 @@
|
||||
smartctl 7.0 2018-12-30 r4883 [NetBSD 9.0_STABLE amd64] (local build)
|
||||
Copyright (C) 2002-18, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p10 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: SAMSUNG SpinPoint F1 DT
|
||||
@@ -11,9 +11,16 @@ User Capacity: 1,000,204,886,016 bytes [1.00 TB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA/ATAPI-7, ATA8-ACS T13/1699-D revision 3b
|
||||
Local Time is: Fri Oct 2 16:59:49 2020 EEST
|
||||
Local Time is: Thu Oct 15 18:38:15 2020 EEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
APM level is: 254 (maximum performance)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
@@ -54,36 +61,191 @@ SCT capabilities: (0x003f) SCT Status supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
|
||||
1 Raw_Read_Error_Rate 0x000f 100 100 051 Pre-fail Always - 0
|
||||
3 Spin_Up_Time 0x0007 077 077 011 Pre-fail Always - 7810
|
||||
4 Start_Stop_Count 0x0032 097 097 000 Old_age Always - 3532
|
||||
5 Reallocated_Sector_Ct 0x0033 100 100 010 Pre-fail Always - 0
|
||||
7 Seek_Error_Rate 0x000f 100 100 051 Pre-fail Always - 0
|
||||
8 Seek_Time_Performance 0x0025 100 100 015 Pre-fail Offline - 0
|
||||
9 Power_On_Hours 0x0032 098 098 000 Old_age Always - 11990
|
||||
10 Spin_Retry_Count 0x0033 100 100 051 Pre-fail Always - 0
|
||||
11 Calibration_Retry_Count 0x0012 100 100 000 Old_age Always - 0
|
||||
12 Power_Cycle_Count 0x0032 097 097 000 Old_age Always - 3531
|
||||
13 Read_Soft_Error_Rate 0x000e 100 100 000 Old_age Always - 0
|
||||
183 Runtime_Bad_Block 0x0032 100 100 000 Old_age Always - 34
|
||||
184 End-to-End_Error 0x0033 100 100 000 Pre-fail Always - 0
|
||||
187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0
|
||||
188 Command_Timeout 0x0032 100 100 000 Old_age Always - 0
|
||||
190 Airflow_Temperature_Cel 0x0022 075 056 000 Old_age Always - 25 (Min/Max 24/25)
|
||||
194 Temperature_Celsius 0x0022 072 055 000 Old_age Always - 28 (Min/Max 24/28)
|
||||
195 Hardware_ECC_Recovered 0x001a 100 100 000 Old_age Always - 83650
|
||||
196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 0
|
||||
197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0
|
||||
198 Offline_Uncorrectable 0x0030 100 100 000 Old_age Offline - 0
|
||||
199 UDMA_CRC_Error_Count 0x003e 100 100 000 Old_age Always - 55
|
||||
200 Multi_Zone_Error_Rate 0x000a 100 100 000 Old_age Always - 0
|
||||
201 Soft_Read_Error_Rate 0x000a 253 253 000 Old_age Always - 0
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 100 100 051 - 0
|
||||
3 Spin_Up_Time POS--- 076 076 011 - 8070
|
||||
4 Start_Stop_Count -O--CK 096 096 000 - 3536
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 100 100 051 - 0
|
||||
8 Seek_Time_Performance P-S--K 100 100 015 - 0
|
||||
9 Power_On_Hours -O--CK 098 098 000 - 11991
|
||||
10 Spin_Retry_Count PO--CK 100 100 051 - 0
|
||||
11 Calibration_Retry_Count -O--C- 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 097 097 000 - 3535
|
||||
13 Read_Soft_Error_Rate -OSR-- 100 100 000 - 0
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 34
|
||||
184 End-to-End_Error PO--CK 100 100 000 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 080 056 000 - 20 (Min/Max 13/20)
|
||||
194 Temperature_Celsius -O---K 073 055 000 - 27 (Min/Max 13/27)
|
||||
195 Hardware_ECC_Recovered -O-RC- 100 100 000 - 188962
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 100 100 000 - 55
|
||||
200 Multi_Zone_Error_Rate -O-R-- 100 100 000 - 0
|
||||
201 Soft_Read_Error_Rate -O-R-- 253 253 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
SMART Error Log Version: 1
|
||||
No Errors Logged
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 2 Comprehensive SMART error log
|
||||
0x03 GPL R/O 2 Ext. Comprehensive SMART error log
|
||||
0x04 GPL R/O 2 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 2 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 2 Write stream error log
|
||||
0x22 GPL R/O 2 Read stream error log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Self-test log structure revision number 1
|
||||
SMART Extended Comprehensive Error Log Version: 1 (2 sectors)
|
||||
Device Error Count: 55 (device log contains only the most recent 8 errors)
|
||||
CR = Command Register
|
||||
FEATR = Features Register
|
||||
COUNT = Count (was: Sector Count) Register
|
||||
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
|
||||
LH = LBA High (was: Cylinder High) Register ] LBA
|
||||
LM = LBA Mid (was: Cylinder Low) Register ] Register
|
||||
LL = LBA Low (was: Sector Number) Register ]
|
||||
DV = Device (was: Device/Head) Register
|
||||
DC = Device Control Register
|
||||
ER = Error register
|
||||
ST = Status register
|
||||
Powered_Up_Time is measured from power on, and printed as
|
||||
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
||||
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
||||
|
||||
Error 55 [6] occurred at disk power-on lifetime: 11978 hours (499 days + 2 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
84 -- 5b ff ff 00 00 3f 1c 38 3d 40 00 Error: ICRC, ABRT 65535 sectors at LBA = 0x3f1c383d = 1058814013
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
35 00 00 00 04 00 00 3f 1c 38 38 40 00 00:49:42.970 WRITE DMA EXT
|
||||
35 00 00 00 20 00 00 3f 1b c0 20 40 00 00:49:42.970 WRITE DMA EXT
|
||||
35 00 00 00 04 00 00 3f 1c 38 38 40 00 00:49:42.970 WRITE DMA EXT
|
||||
35 00 00 00 20 00 00 3f 1b c0 20 40 00 00:49:42.970 WRITE DMA EXT
|
||||
35 00 00 00 04 00 00 3f 1c 38 38 40 00 00:49:42.970 WRITE DMA EXT
|
||||
|
||||
Error 54 [5] occurred at disk power-on lifetime: 11446 hours (476 days + 22 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
00 -- 48 00 80 00 00 72 60 25 80 40 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
|
||||
Error 53 [4] occurred at disk power-on lifetime: 11446 hours (476 days + 22 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
00 -- 48 00 4c 00 00 72 60 25 34 40 00 at LBA = 0x72602534 = 1918903604
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
61 00 00 00 80 00 00 00 60 26 80 40 00 03:07:59.780 WRITE FPDMA QUEUED
|
||||
61 00 00 00 80 00 00 00 60 26 00 40 00 03:07:59.780 WRITE FPDMA QUEUED
|
||||
61 00 00 00 80 00 00 00 60 25 80 40 00 03:07:59.780 WRITE FPDMA QUEUED
|
||||
61 00 00 00 80 00 00 00 60 25 00 40 00 03:07:59.780 WRITE FPDMA QUEUED
|
||||
61 00 00 00 80 00 00 00 60 24 80 40 00 03:07:59.780 WRITE FPDMA QUEUED
|
||||
|
||||
Error 52 [3] occurred at disk power-on lifetime: 11446 hours (476 days + 22 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
00 -- 48 00 80 00 00 72 4d 70 00 40 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
|
||||
Error 51 [2] occurred at disk power-on lifetime: 11446 hours (476 days + 22 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
00 -- 48 00 06 00 00 72 4d 6f fa 40 00 at LBA = 0x724d6ffa = 1917677562
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
61 00 00 00 80 00 00 00 4d 72 80 40 00 02:46:41.170 WRITE FPDMA QUEUED
|
||||
61 00 00 00 80 00 00 00 4d 72 00 40 00 02:46:41.170 WRITE FPDMA QUEUED
|
||||
61 00 00 00 80 00 00 00 4d 71 80 40 00 02:46:41.170 WRITE FPDMA QUEUED
|
||||
61 00 00 00 80 00 00 00 4d 71 00 40 00 02:46:41.170 WRITE FPDMA QUEUED
|
||||
61 00 00 00 80 00 00 00 4d 70 80 40 00 02:46:41.170 WRITE FPDMA QUEUED
|
||||
|
||||
Error 50 [1] occurred at disk power-on lifetime: 11446 hours (476 days + 22 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
00 -- 48 00 80 00 00 72 4d 45 00 40 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
|
||||
Error 49 [0] occurred at disk power-on lifetime: 11446 hours (476 days + 22 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
00 -- 48 00 09 00 00 72 4d 44 f7 40 00 at LBA = 0x724d44f7 = 1917666551
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
61 00 00 00 80 00 00 00 4d 4e 80 40 00 02:46:16.360 WRITE FPDMA QUEUED
|
||||
61 00 00 00 80 00 00 00 4d 4e 00 40 00 02:46:16.360 WRITE FPDMA QUEUED
|
||||
61 00 00 00 80 00 00 00 4d 4d 80 40 00 02:46:16.360 WRITE FPDMA QUEUED
|
||||
61 00 00 00 80 00 00 00 4d 4d 00 40 00 02:46:16.360 WRITE FPDMA QUEUED
|
||||
61 00 00 00 80 00 00 00 4d 4c 80 40 00 02:46:16.360 WRITE FPDMA QUEUED
|
||||
|
||||
Error 48 [7] occurred at disk power-on lifetime: 11446 hours (476 days + 22 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
00 -- 48 00 80 00 00 72 4d 45 00 40 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (2 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
@@ -97,5 +259,47 @@ Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 27 Celsius
|
||||
Power Cycle Min/Max Temperature: --/27 Celsius
|
||||
Lifetime Min/Max Temperature: --/45 Celsius
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: -4/72 Celsius
|
||||
Min/Max Temperature Limit: -9/77 Celsius
|
||||
Temperature History Size (Index): 128 (73)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
ATA_READ_LOG_EXT (addr=0x04:0x00, page=0, n=1) failed: Input/output error
|
||||
Read Device Statistics page 0x00 failed
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 15 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 114 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0010 2 0 R_ERR response for host-to-device data FIS, non-CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x0013 2 0 R_ERR response for host-to-device non-data FIS, non-CRC
|
||||
|
||||
|
||||
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RC4 amd64] (local build)
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p2 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -14,7 +14,7 @@ Form Factor: 3.5 inches
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s
|
||||
Local Time is: Thu Apr 28 19:24:34 2022 CEST
|
||||
Local Time is: Tue Sep 27 20:53:44 2022 CEST
|
||||
|
||||
==> WARNING: Using smartmontools or hdparm with this
|
||||
drive may result in data loss due to a firmware bug.
|
||||
@@ -75,15 +75,15 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 051 - 135
|
||||
2 Throughput_Performance -OS--K 252 252 000 - 0
|
||||
3 Spin_Up_Time PO---K 067 043 025 - 10258
|
||||
4 Start_Stop_Count -O--CK 097 097 000 - 3949
|
||||
4 Start_Stop_Count -O--CK 096 096 000 - 4343
|
||||
5 Reallocated_Sector_Ct PO--CK 252 252 010 - 0
|
||||
7 Seek_Error_Rate -OSR-K 252 252 051 - 0
|
||||
8 Seek_Time_Performance --S--K 252 252 015 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 19447
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 20351
|
||||
10 Spin_Retry_Count -O--CK 252 252 051 - 0
|
||||
11 Calibration_Retry_Count -O--CK 252 252 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 2368
|
||||
181 Program_Fail_Cnt_Total -O---K 100 100 000 - 6794116
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 2646
|
||||
181 Program_Fail_Cnt_Total -O---K 100 100 000 - 6794324
|
||||
191 G-Sense_Error_Rate -O---K 001 001 000 - 28810582
|
||||
192 Power-Off_Retract_Count -O---K 252 252 000 - 0
|
||||
194 Temperature_Celsius -O---- 061 047 000 - 39 (Min/Max 14/53)
|
||||
@@ -94,7 +94,7 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
199 UDMA_CRC_Error_Count -OS-CK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate -O-R-K 001 001 000 - 106416
|
||||
223 Load_Retry_Count -O--CK 252 252 000 - 0
|
||||
225 Load_Cycle_Count -O--CK 100 100 000 - 4123
|
||||
225 Load_Cycle_Count -O--CK 100 100 000 - 4521
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -291,7 +291,7 @@ SCT Status Version: 2
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 39 Celsius
|
||||
Power Cycle Min/Max Temperature: 17/40 Celsius
|
||||
Power Cycle Min/Max Temperature: 18/39 Celsius
|
||||
Lifetime Min/Max Temperature: 9/66 Celsius
|
||||
Specified Max Operating Temperature: 80 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
@@ -301,7 +301,7 @@ Temperature Sampling Period: 5 minutes
|
||||
Temperature Logging Interval: 5 minutes
|
||||
Min/Max recommended Temperature: -5/80 Celsius
|
||||
Min/Max Temperature Limit: -10/85 Celsius
|
||||
Temperature History Size (Index): 128 (7)
|
||||
Temperature History Size (Index): 128 (119)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
|
@@ -1,5 +1,5 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RELEASE-p4 amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.0-RELEASE-p8 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: SAMSUNG SpinPoint F4 EG (AF)
|
||||
@@ -11,10 +11,10 @@ User Capacity: 2,000,398,934,016 bytes [2.00 TB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: 5400 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s
|
||||
Local Time is: Mon Sep 27 03:19:31 2021 CEST
|
||||
Local Time is: Thu Apr 7 02:12:18 2022 CEST
|
||||
|
||||
==> WARNING: Using smartmontools or hdparm with this
|
||||
drive may result in data loss due to a firmware bug.
|
||||
@@ -74,19 +74,19 @@ Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 051 - 1
|
||||
2 Throughput_Performance -OS--K 055 055 000 - 19172
|
||||
3 Spin_Up_Time PO---K 067 065 025 - 10281
|
||||
4 Start_Stop_Count -O--CK 096 096 000 - 4213
|
||||
3 Spin_Up_Time PO---K 066 065 025 - 10365
|
||||
4 Start_Stop_Count -O--CK 096 096 000 - 4461
|
||||
5 Reallocated_Sector_Ct PO--CK 252 252 010 - 0
|
||||
7 Seek_Error_Rate -OSR-K 252 252 051 - 0
|
||||
8 Seek_Time_Performance --S--K 252 252 015 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 50615
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 54207
|
||||
10 Spin_Retry_Count -O--CK 252 252 051 - 0
|
||||
11 Calibration_Retry_Count -O--CK 252 252 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 097 097 000 - 3766
|
||||
181 Program_Fail_Cnt_Total -O---K 099 099 000 - 32473619
|
||||
191 G-Sense_Error_Rate -O---K 100 100 000 - 142
|
||||
12 Power_Cycle_Count -O--CK 097 097 000 - 3930
|
||||
181 Program_Fail_Cnt_Total -O---K 099 099 000 - 32981274
|
||||
191 G-Sense_Error_Rate -O---K 100 100 000 - 148
|
||||
192 Power-Off_Retract_Count -O---K 252 252 000 - 0
|
||||
194 Temperature_Celsius -O---- 054 046 000 - 46 (Min/Max 8/54)
|
||||
194 Temperature_Celsius -O---- 057 046 000 - 43 (Min/Max 8/54)
|
||||
195 Hardware_ECC_Recovered -O-RCK 100 100 000 - 0
|
||||
196 Reallocated_Event_Count -O--CK 252 252 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 252 252 000 - 0
|
||||
@@ -94,7 +94,7 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
199 UDMA_CRC_Error_Count -OS-CK 100 100 000 - 2
|
||||
200 Multi_Zone_Error_Rate -O-R-K 100 100 000 - 22
|
||||
223 Load_Retry_Count -O--CK 252 252 000 - 0
|
||||
225 Load_Cycle_Count -O--CK 100 100 000 - 4270
|
||||
225 Load_Cycle_Count -O--CK 100 100 000 - 4518
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -172,8 +172,10 @@ Error 1 [0] occurred at disk power-on lifetime: 17542 hours (730 days + 22 hours
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (2 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Extended offline Completed without error 00% 21194 -
|
||||
# 2 Short offline Completed without error 00% 20835 -
|
||||
# 1 Short offline Completed without error 00% 50725 -
|
||||
# 2 Short offline Aborted by host 30% 50725 -
|
||||
# 3 Extended offline Completed without error 00% 21194 -
|
||||
# 4 Short offline Completed without error 00% 20835 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 0
|
||||
Note: revision number not 1 implies that no selective self-test has ever been run
|
||||
@@ -190,8 +192,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 46 Celsius
|
||||
Power Cycle Min/Max Temperature: 33/47 Celsius
|
||||
Current Temperature: 43 Celsius
|
||||
Power Cycle Min/Max Temperature: 23/44 Celsius
|
||||
Lifetime Min/Max Temperature: 8/60 Celsius
|
||||
Specified Max Operating Temperature: 80 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
@@ -201,7 +203,7 @@ Temperature Sampling Period: 5 minutes
|
||||
Temperature Logging Interval: 5 minutes
|
||||
Min/Max recommended Temperature: -5/80 Celsius
|
||||
Min/Max Temperature Limit: -10/85 Celsius
|
||||
Temperature History Size (Index): 128 (44)
|
||||
Temperature History Size (Index): 128 (27)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -221,8 +223,8 @@ ID Size Value Description
|
||||
0x0006 4 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 4 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 4 0 Device-to-host non-data FIS retries
|
||||
0x0009 4 21 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 4 20 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 4 9 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 4 8 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 4 0 CRC errors within host-to-device FIS
|
||||
0x000d 4 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 4 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|
@@ -1,5 +1,5 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: SAMSUNG SpinPoint F1 DT
|
||||
@@ -9,9 +9,9 @@ LU WWN Device Id: 5 0024e9 ...
|
||||
Firmware Version: 1AC01118
|
||||
User Capacity: 320,072,933,376 bytes [320 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ATA/ATAPI-7, ATA8-ACS T13/1699-D revision 3b
|
||||
Local Time is: Tue Mar 29 09:37:26 2022 EDT
|
||||
Local Time is: Wed Feb 8 14:50:38 2023 UTC
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
@@ -63,27 +63,27 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 100 100 051 - 0
|
||||
3 Spin_Up_Time POS--- 092 092 011 - 3450
|
||||
4 Start_Stop_Count -O--CK 096 096 000 - 3992
|
||||
3 Spin_Up_Time POS--- 092 092 011 - 3350
|
||||
4 Start_Stop_Count -O--CK 095 095 000 - 5251
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 100 100 051 - 0
|
||||
8 Seek_Time_Performance P-S--K 100 100 015 - 0
|
||||
9 Power_On_Hours -O--CK 098 098 000 - 8150
|
||||
8 Seek_Time_Performance P-S--K 100 100 015 - 10101
|
||||
9 Power_On_Hours -O--CK 098 098 000 - 11000
|
||||
10 Spin_Retry_Count PO--CK 100 100 051 - 0
|
||||
11 Calibration_Retry_Count -O--C- 100 100 000 - 37
|
||||
12 Power_Cycle_Count -O--CK 097 097 000 - 2686
|
||||
12 Power_Cycle_Count -O--CK 097 097 000 - 3216
|
||||
13 Read_Soft_Error_Rate -OSR-- 100 100 000 - 0
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 8
|
||||
184 End-to-End_Error PO--CK 100 100 000 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 067 057 000 - 33 (Min/Max 25/33)
|
||||
194 Temperature_Celsius -O---K 062 057 000 - 38 (Min/Max 25/38)
|
||||
195 Hardware_ECC_Recovered -O-RC- 100 100 000 - 88764
|
||||
190 Airflow_Temperature_Cel -O---K 071 057 000 - 29 (Min/Max 28/30)
|
||||
194 Temperature_Celsius -O---K 067 057 000 - 33 (Min/Max 27/33)
|
||||
195 Hardware_ECC_Recovered -O-RC- 100 100 000 - 2783
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 100 100 000 - 44
|
||||
199 UDMA_CRC_Error_Count -OSRCK 100 100 000 - 45
|
||||
200 Multi_Zone_Error_Rate -O-R-- 100 096 000 - 62
|
||||
201 Soft_Read_Error_Rate -O-R-- 253 253 000 - 0
|
||||
||||||_ K auto-keep
|
||||
@@ -114,7 +114,7 @@ Address Access R/W Size Description
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (2 sectors)
|
||||
Device Error Count: 44 (device log contains only the most recent 8 errors)
|
||||
Device Error Count: 45 (device log contains only the most recent 8 errors)
|
||||
CR = Command Register
|
||||
FEATR = Features Register
|
||||
COUNT = Count (was: Sector Count) Register
|
||||
@@ -130,6 +130,23 @@ Powered_Up_Time is measured from power on, and printed as
|
||||
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
||||
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
||||
|
||||
Error 45 [4] occurred at disk power-on lifetime: 9077 hours (378 days + 5 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
00 -- 80 00 01 00 00 00 00 00 01 a0 00 at LBA = 0x00000001 = 1
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
61 00 00 03 00 00 00 00 02 4a 40 40 00 03:25:22.650 WRITE FPDMA QUEUED
|
||||
ca 00 00 00 30 00 00 00 00 c1 90 45 08 03:25:22.630 WRITE DMA
|
||||
ca 00 00 00 30 00 00 00 00 c1 50 45 08 03:25:22.610 WRITE DMA
|
||||
ca 00 00 00 30 00 00 00 00 c1 10 45 08 03:25:22.590 WRITE DMA
|
||||
60 00 00 00 40 00 00 00 00 c0 c0 40 00 03:25:22.590 READ FPDMA QUEUED
|
||||
|
||||
Error 44 [3] occurred at disk power-on lifetime: 6759 hours (281 days + 15 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
@@ -249,25 +266,9 @@ Error 38 [5] occurred at disk power-on lifetime: 6747 hours (281 days + 3 hours)
|
||||
60 00 00 01 00 00 00 00 ab 86 f8 40 00 01:33:51.760 READ FPDMA QUEUED
|
||||
60 00 00 00 18 00 00 00 ab 86 e0 40 00 01:33:51.030 READ FPDMA QUEUED
|
||||
|
||||
Error 37 [4] occurred at disk power-on lifetime: 6747 hours (281 days + 3 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
00 -- 4a 00 6f 00 00 09 6b 6f 39 40 00 at LBA = 0x096b6f39 = 158035769
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 00 01 00 00 00 00 6b 6e a8 40 00 01:30:39.010 READ FPDMA QUEUED
|
||||
60 00 00 01 00 00 00 00 6b 6d a8 40 00 01:30:36.000 READ FPDMA QUEUED
|
||||
60 00 00 01 00 00 00 00 6b 6c a8 40 00 01:30:32.940 READ FPDMA QUEUED
|
||||
60 00 00 01 00 00 00 00 6b 6b a8 40 00 01:30:28.760 READ FPDMA QUEUED
|
||||
60 00 00 01 00 00 00 00 6b 6a a8 40 00 01:30:25.700 READ FPDMA QUEUED
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (2 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 9086 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
@@ -283,8 +284,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 38 Celsius
|
||||
Power Cycle Min/Max Temperature: --/38 Celsius
|
||||
Current Temperature: 32 Celsius
|
||||
Power Cycle Min/Max Temperature: --/33 Celsius
|
||||
Lifetime Min/Max Temperature: --/44 Celsius
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
@@ -292,7 +293,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: -4/72 Celsius
|
||||
Min/Max Temperature Limit: -9/77 Celsius
|
||||
Temperature History Size (Index): 128 (65)
|
||||
Temperature History Size (Index): 128 (36)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -305,7 +306,7 @@ Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 4 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000a 2 8 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
@@ -314,7 +315,7 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 4 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x0009 2 8 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|
@@ -1,5 +1,5 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RELEASE-p4 amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.0-RELEASE-p8 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: SAMSUNG SpinPoint F2 EG
|
||||
@@ -9,9 +9,9 @@ LU WWN Device Id: 5 0024e9 ...
|
||||
Firmware Version: 1AG01113
|
||||
User Capacity: 500,107,862,016 bytes [500 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ATA/ATAPI-7, ATA8-ACS T13/1699-D revision 3b
|
||||
Local Time is: Mon Sep 27 03:19:33 2021 CEST
|
||||
Local Time is: Thu Apr 7 02:12:19 2022 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
@@ -63,23 +63,23 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 100 100 051 - 0
|
||||
3 Spin_Up_Time POS--- 093 093 011 - 3180
|
||||
4 Start_Stop_Count -O--CK 093 093 000 - 6611
|
||||
3 Spin_Up_Time POS--- 093 093 011 - 3110
|
||||
4 Start_Stop_Count -O--CK 093 093 000 - 6843
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 100 100 051 - 0
|
||||
8 Seek_Time_Performance P-S--K 100 100 015 - 10036
|
||||
9 Power_On_Hours -O--CK 088 088 000 - 59033
|
||||
8 Seek_Time_Performance P-S--K 100 100 015 - 11392
|
||||
9 Power_On_Hours -O--CK 088 088 000 - 62433
|
||||
10 Spin_Retry_Count PO--CK 100 100 051 - 0
|
||||
11 Calibration_Retry_Count -O--C- 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 094 094 000 - 5845
|
||||
12 Power_Cycle_Count -O--CK 094 094 000 - 6009
|
||||
13 Read_Soft_Error_Rate -OSR-- 100 100 000 - 0
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error PO--CK 100 100 000 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 067 055 000 - 33 (Min/Max 28/33)
|
||||
194 Temperature_Celsius -O---K 067 053 000 - 33 (Min/Max 28/33)
|
||||
195 Hardware_ECC_Recovered -O-RC- 100 100 000 - 71499
|
||||
190 Airflow_Temperature_Cel -O---K 065 055 000 - 35 (Min/Max 19/35)
|
||||
194 Temperature_Celsius -O---K 065 053 000 - 35 (Min/Max 19/36)
|
||||
195 Hardware_ECC_Recovered -O-RC- 100 100 000 - 30730
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
@@ -149,11 +149,12 @@ Error 1 [0] occurred at disk power-on lifetime: 53076 hours (2211 days + 12 hour
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (2 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Extended offline Completed without error 00% 29603 -
|
||||
# 2 Extended offline Aborted by host 80% 1400 -
|
||||
# 3 Extended offline Aborted by host 90% 1400 -
|
||||
# 1 Short offline Completed without error 00% 59143 -
|
||||
# 2 Extended offline Completed without error 00% 29603 -
|
||||
# 3 Extended offline Aborted by host 80% 1400 -
|
||||
# 4 Extended offline Aborted by host 90% 1400 -
|
||||
# 5 Extended offline Aborted by host 90% 1400 -
|
||||
# 6 Extended offline Aborted by host 90% 1400 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
@@ -169,8 +170,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 33 Celsius
|
||||
Power Cycle Min/Max Temperature: --/33 Celsius
|
||||
Current Temperature: 35 Celsius
|
||||
Power Cycle Min/Max Temperature: --/36 Celsius
|
||||
Lifetime Min/Max Temperature: --/48 Celsius
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
@@ -178,7 +179,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: -4/72 Celsius
|
||||
Min/Max Temperature Limit: -9/77 Celsius
|
||||
Temperature History Size (Index): 128 (41)
|
||||
Temperature History Size (Index): 128 (26)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -191,7 +192,7 @@ Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 20 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000a 2 8 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
@@ -200,7 +201,7 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 20 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x0009 2 8 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|
@@ -13,7 +13,7 @@ Form Factor: 2.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s
|
||||
Local Time is: Sat Apr 3 07:22:08 2021 -08
|
||||
Local Time is: Fri Apr 23 17:57:21 2021 -08
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
@@ -64,15 +64,15 @@ Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 051 - 9
|
||||
2 Throughput_Performance -OS--K 252 252 000 - 0
|
||||
3 Spin_Up_Time PO---K 087 077 025 - 4000
|
||||
4 Start_Stop_Count -O--CK 099 099 000 - 1156
|
||||
3 Spin_Up_Time PO---K 087 077 025 - 4040
|
||||
4 Start_Stop_Count -O--CK 099 099 000 - 1186
|
||||
5 Reallocated_Sector_Ct PO--CK 252 252 010 - 0
|
||||
7 Seek_Error_Rate -OSR-K 252 252 051 - 0
|
||||
8 Seek_Time_Performance --S--K 252 252 015 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 3663
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 3796
|
||||
10 Spin_Retry_Count -O--CK 252 252 051 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 470
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 1428
|
||||
11 Calibration_Retry_Count -O--CK 099 099 000 - 1028
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 1466
|
||||
191 G-Sense_Error_Rate -O---K 100 100 000 - 683
|
||||
192 Power-Off_Retract_Count -O---K 252 252 000 - 0
|
||||
194 Temperature_Celsius -O---- 064 039 000 - 32 (Min/Max 9/62)
|
||||
@@ -82,8 +82,8 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
198 Offline_Uncorrectable ----CK 252 252 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OS-CK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate -O-R-K 100 100 000 - 1406
|
||||
223 Load_Retry_Count -O--CK 100 100 000 - 470
|
||||
225 Load_Cycle_Count -O--CK 001 001 000 - 4785217
|
||||
223 Load_Retry_Count -O--CK 099 099 000 - 1028
|
||||
225 Load_Cycle_Count -O--CK 001 001 000 - 4872509
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -131,7 +131,7 @@ SCT Status Version: 2
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 32 Celsius
|
||||
Power Cycle Min/Max Temperature: 32/32 Celsius
|
||||
Power Cycle Min/Max Temperature: 28/32 Celsius
|
||||
Lifetime Min/Max Temperature: 12/62 Celsius
|
||||
Specified Max Operating Temperature: 80 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
@@ -141,7 +141,7 @@ Temperature Sampling Period: 5 minutes
|
||||
Temperature Logging Interval: 5 minutes
|
||||
Min/Max recommended Temperature: -5/80 Celsius
|
||||
Min/Max Temperature Limit: -10/85 Celsius
|
||||
Temperature History Size (Index): 128 (14)
|
||||
Temperature History Size (Index): 128 (73)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
|
@@ -14,7 +14,7 @@ Form Factor: 2.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s
|
||||
Local Time is: Sun Feb 6 17:51:07 2022 CET
|
||||
Local Time is: Sun Feb 13 11:09:58 2022 CET
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
|
||||
@@ -57,28 +57,28 @@ SCT capabilities: (0x003f) SCT Status supported.
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
|
||||
1 Raw_Read_Error_Rate 0x002f 100 100 051 Pre-fail Always - 8
|
||||
1 Raw_Read_Error_Rate 0x002f 100 100 051 Pre-fail Always - 10
|
||||
2 Throughput_Performance 0x0026 252 252 000 Old_age Always - 0
|
||||
3 Spin_Up_Time 0x0023 089 089 025 Pre-fail Always - 3409
|
||||
4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 476
|
||||
3 Spin_Up_Time 0x0023 089 089 025 Pre-fail Always - 3404
|
||||
4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 542
|
||||
5 Reallocated_Sector_Ct 0x0033 252 252 010 Pre-fail Always - 0
|
||||
7 Seek_Error_Rate 0x002e 252 252 051 Old_age Always - 0
|
||||
8 Seek_Time_Performance 0x0024 252 252 015 Old_age Offline - 0
|
||||
9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 194
|
||||
9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 224
|
||||
10 Spin_Retry_Count 0x0032 252 252 051 Old_age Always - 0
|
||||
11 Calibration_Retry_Count 0x0032 100 100 000 Old_age Always - 596
|
||||
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 483
|
||||
191 G-Sense_Error_Rate 0x0022 100 100 000 Old_age Always - 631
|
||||
11 Calibration_Retry_Count 0x0032 100 100 000 Old_age Always - 608
|
||||
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 544
|
||||
191 G-Sense_Error_Rate 0x0022 100 100 000 Old_age Always - 684
|
||||
192 Power-Off_Retract_Count 0x0022 252 252 000 Old_age Always - 0
|
||||
194 Temperature_Celsius 0x0002 064 064 000 Old_age Always - 26 (Min/Max 14/38)
|
||||
194 Temperature_Celsius 0x0002 064 064 000 Old_age Always - 27 (Min/Max 12/38)
|
||||
195 Hardware_ECC_Recovered 0x003a 100 100 000 Old_age Always - 0
|
||||
196 Reallocated_Event_Count 0x0032 252 252 000 Old_age Always - 0
|
||||
197 Current_Pending_Sector 0x0032 252 252 000 Old_age Always - 0
|
||||
198 Offline_Uncorrectable 0x0030 252 252 000 Old_age Offline - 0
|
||||
199 UDMA_CRC_Error_Count 0x0036 100 100 000 Old_age Always - 11
|
||||
200 Multi_Zone_Error_Rate 0x002a 100 100 000 Old_age Always - 26
|
||||
223 Load_Retry_Count 0x0032 100 100 000 Old_age Always - 596
|
||||
225 Load_Cycle_Count 0x0032 099 099 000 Old_age Always - 12469
|
||||
200 Multi_Zone_Error_Rate 0x002a 100 100 000 Old_age Always - 29
|
||||
223 Load_Retry_Count 0x0032 100 100 000 Old_age Always - 608
|
||||
225 Load_Cycle_Count 0x0032 099 099 000 Old_age Always - 14836
|
||||
|
||||
SMART Error Log Version: 1
|
||||
No Errors Logged
|
||||
|
Reference in New Issue
Block a user