@@ -14,7 +14,7 @@ Form Factor: 2.5 inches
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 2.6, 3.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Thu Jan 27 11:25:09 2022 EST
Local Time is: Fri Jan 28 12:21:49 2022 EST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -65,27 +65,27 @@ Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate PO-R-- 100 100 050 - 0
2 Throughput_Performance P-S--- 100 100 050 - 0
3 Spin_Up_Time POS--K 100 100 001 - 1076
4 Start_Stop_Count -O--CK 100 100 000 - 3126
3 Spin_Up_Time POS--K 100 100 001 - 1050
4 Start_Stop_Count -O--CK 100 100 000 - 3136
5 Reallocated_Sector_Ct PO--CK 100 100 050 - 0
7 Seek_Error_Rate PO-R-- 100 100 050 - 0
8 Seek_Time_Performance P-S--- 100 100 050 - 0
9 Power_On_Hours -O--CK 067 067 000 - 13229
9 Power_On_Hours -O--CK 067 067 000 - 13233
10 Spin_Retry_Count PO--CK 162 100 030 - 0
12 Power_Cycle_Count -O--CK 100 100 000 - 3076
12 Power_Cycle_Count -O--CK 100 100 000 - 3086
191 G-Sense_Error_Rate -O--CK 100 100 000 - 585
192 Power-Off_Retract_Count -O--CK 099 099 000 - 810
193 Load_Cycle_Count -O--CK 094 094 000 - 66616
194 Temperature_Celsius -O---K 100 100 000 - 31 (Min/Max 10/63)
192 Power-Off_Retract_Count -O--CK 099 099 000 - 812
193 Load_Cycle_Count -O--CK 094 094 000 - 66665
194 Temperature_Celsius -O---K 100 100 000 - 36 (Min/Max 10/63)
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
197 Current_Pending_Sector -O--CK 100 100 000 - 0
198 Offline_Uncorrectable ----CK 100 100 000 - 0
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
220 Disk_Shift -O---- 100 100 000 - 0
222 Loaded_Hours -O--CK 070 070 000 - 12073
222 Loaded_Hours -O--CK 070 070 000 - 12077
223 Load_Retry_Count -O--CK 100 100 000 - 0
224 Load_Friction -O---K 100 100 000 - 0
226 Load-in_Time -OS--K 100 100 000 - 265
226 Load-in_Time -OS--K 100 100 000 - 258
240 Head_Flying_Hours P----- 100 100 001 - 0
||||||_ K auto-keep
|||||__ C event count
@@ -132,8 +132,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 2
SCT Version (vendor specific): 1 (0x0001)
Device State: Active (0)
Current Temperature: 30 Celsius
Power Cycle Min/Max Temperature: 30/31 Celsius
Current Temperature: 36 Celsius
Power Cycle Min/Max Temperature: 33/37 Celsius
Lifetime Min/Max Temperature: 10/63 Celsius
Under/Over Temperature Limit Count: 0/9100
@@ -142,7 +142,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 5/55 Celsius
Min/Max Temperature Limit: 5/55 Celsius
Temperature History Size (Index): 478 (49)
Temperature History Size (Index): 478 (327)
SCT Error Recovery Control:
Read: Disabled
@@ -151,18 +151,18 @@ SCT Error Recovery Control:
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 2) ==
0x01 0x008 4 3076 --- Lifetime Power-On Resets
0x01 0x010 4 13229 --- Power-on Hours
0x01 0x018 6 42413564731 --- Logical Sectors Written
0x01 0x020 6 317585306 --- Number of Write Commands
0x01 0x028 6 50860642904 --- Logical Sectors Read
0x01 0x030 6 373444481 --- Number of Read Commands
0x01 0x008 4 3086 --- Lifetime Power-On Resets
0x01 0x010 4 13233 --- Power-on Hours
0x01 0x018 6 42480203509 --- Logical Sectors Written
0x01 0x020 6 317965679 --- Number of Write Commands
0x01 0x028 6 50879982708 --- Logical Sectors Read
0x01 0x030 6 373631286 --- Number of Read Commands
0x02 ===== = = === == Free-Fall Statistics (rev 1) ==
0x02 0x010 4 585 --- Overlimit Shock Events
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
0x03 0x008 4 13228 --- Spindle Motor Power-on Hours
0x03 0x010 4 12073 --- Head Flying Hours
0x03 0x018 4 66616 --- Head Load Events
0x03 0x008 4 13232 --- Spindle Motor Power-on Hours
0x03 0x010 4 12077 --- Head Flying Hours
0x03 0x018 4 66665 --- Head Load Events
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
0x03 0x028 4 0 --- Read Recovery Attempts
0x03 0x030 4 0 --- Number of Mechanical Start Failures
@@ -170,7 +170,7 @@ Page Offset Size Value Flags Description
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 5 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 30 --- Current Temperature
0x05 0x008 1 36 --- Current Temperature
0x05 0x010 1 30 N-- Average Short Term Temperature
0x05 0x018 1 30 N-- Average Long Term Temperature
0x05 0x020 1 63 --- Highest Temperature
@@ -184,7 +184,7 @@ Page Offset Size Value Flags Description
0x05 0x060 4 0 --- Time in Under-Temperature
0x05 0x068 1 5 --- Specified Minimum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 3535 --- Number of Hardware Resets
0x06 0x008 4 3561 --- Number of Hardware Resets
0x06 0x018 4 0 --- Number of Interface CRC Errors
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
0x07 0x008 1 22 N-- Percentage Used Endurance Indicator
@@ -204,8 +204,8 @@ ID Size Value Description
0x0006 4 0 R_ERR response for device-to-host non-data FIS
0x0007 4 0 R_ERR response for host-to-device non-data FIS
0x0008 4 0 Device-to-host non-data FIS retries
0x0009 4 2 Transition from drive PhyRdy to drive PhyNRdy
0x000a 4 2 Device-to-host register FISes sent due to a COMRESET
0x0009 4 6 Transition from drive PhyRdy to drive PhyNRdy
0x000a 4 6 Device-to-host register FISes sent due to a COMRESET
0x000b 4 0 CRC errors within host-to-device FIS
0x000d 4 0 Non-CRC errors within host-to-device FIS
0x000f 4 0 R_ERR response for host-to-device data FIS, CRC