mirror of
https://github.com/bsdhw/SMART.git
synced 2025-05-31 16:21:41 +05:30
Update of reports (new: 0, modified: 1434)
This commit is contained in:
@@ -1,5 +1,5 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.2-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Western Digital Red
|
||||
@@ -13,7 +13,7 @@ Rotation Rate: 5400 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Fri Feb 26 07:59:18 2021 EST
|
||||
Local Time is: Thu Nov 25 18:58:46 2021 EST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,22 +65,22 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 136 134 021 - 4200
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 180
|
||||
3 Spin_Up_Time POS--K 135 134 021 - 4216
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 269
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 089 089 000 - 8719
|
||||
9 Power_On_Hours -O--CK 081 081 000 - 14336
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 177
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 106
|
||||
193 Load_Cycle_Count -O--CK 197 197 000 - 11638
|
||||
194 Temperature_Celsius -O---K 113 091 000 - 30
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 266
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 150
|
||||
193 Load_Cycle_Count -O--CK 195 195 000 - 16493
|
||||
194 Temperature_Celsius -O---K 108 091 000 - 35
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 253 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate ---R-- 100 253 000 - 0
|
||||
200 Multi_Zone_Error_Rate ---R-- 200 200 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -115,7 +115,8 @@ SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Extended offline Completed without error 00% 8844 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
@@ -131,8 +132,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 30 Celsius
|
||||
Power Cycle Min/Max Temperature: 28/30 Celsius
|
||||
Current Temperature: 35 Celsius
|
||||
Power Cycle Min/Max Temperature: 33/35 Celsius
|
||||
Lifetime Min/Max Temperature: 16/52 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
@@ -144,7 +145,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (185)
|
||||
Temperature History Size (Index): 478 (237)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 70 (7.0 seconds)
|
||||
@@ -164,12 +165,12 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 3 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 5 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 21 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 23 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 707 Vendor specific
|
||||
0x8000 4 23624 Vendor specific
|
||||
|
||||
|
||||
|
||||
|
@@ -1,5 +1,5 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.2-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Western Digital Red
|
||||
@@ -13,7 +13,7 @@ Rotation Rate: 5400 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Fri Feb 26 07:59:17 2021 EST
|
||||
Local Time is: Thu Nov 25 18:58:46 2021 EST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,22 +65,22 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 137 136 021 - 4116
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 176
|
||||
3 Spin_Up_Time POS--K 137 136 021 - 4133
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 270
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 089 089 000 - 8718
|
||||
9 Power_On_Hours -O--CK 081 081 000 - 14357
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 173
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 103
|
||||
193 Load_Cycle_Count -O--CK 197 197 000 - 11656
|
||||
194 Temperature_Celsius -O---K 114 093 000 - 29
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 267
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 152
|
||||
193 Load_Cycle_Count -O--CK 195 195 000 - 16541
|
||||
194 Temperature_Celsius -O---K 109 093 000 - 34
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 253 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate ---R-- 100 253 000 - 0
|
||||
200 Multi_Zone_Error_Rate ---R-- 200 200 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -112,10 +112,59 @@ Address Access R/W Size Description
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
|
||||
No Errors Logged
|
||||
Device Error Count: 2
|
||||
CR = Command Register
|
||||
FEATR = Features Register
|
||||
COUNT = Count (was: Sector Count) Register
|
||||
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
|
||||
LH = LBA High (was: Cylinder High) Register ] LBA
|
||||
LM = LBA Mid (was: Cylinder Low) Register ] Register
|
||||
LL = LBA Low (was: Sector Number) Register ]
|
||||
DV = Device (was: Device/Head) Register
|
||||
DC = Device Control Register
|
||||
ER = Error register
|
||||
ST = Status register
|
||||
Powered_Up_Time is measured from power on, and printed as
|
||||
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
||||
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
||||
|
||||
Error 2 [1] occurred at disk power-on lifetime: 12858 hours (535 days + 18 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 00 00 00 74 70 5c 20 40 00 Error: UNC at LBA = 0x74705c20 = 1953520672
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 e0 00 48 00 00 74 70 5e 20 40 08 00:19:43.353 READ FPDMA QUEUED
|
||||
60 00 e0 00 40 00 00 74 70 5c 20 40 08 00:19:43.352 READ FPDMA QUEUED
|
||||
60 00 e0 00 38 00 00 3e 80 12 20 40 08 00:19:43.352 READ FPDMA QUEUED
|
||||
60 00 e0 00 30 00 00 3e 80 10 20 40 08 00:19:43.352 READ FPDMA QUEUED
|
||||
60 00 01 00 28 00 00 3e 80 10 00 40 08 00:19:40.720 READ FPDMA QUEUED
|
||||
|
||||
Error 1 [0] occurred at disk power-on lifetime: 10710 hours (446 days + 6 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 00 00 00 01 8a 70 38 40 00 Error: UNC at LBA = 0x018a7038 = 25849912
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 08 00 a8 00 00 01 8a 70 38 40 08 00:00:33.767 READ FPDMA QUEUED
|
||||
60 00 08 00 a0 00 00 54 00 30 18 40 08 00:00:33.724 READ FPDMA QUEUED
|
||||
60 00 08 00 98 00 00 54 00 30 00 40 08 00:00:33.710 READ FPDMA QUEUED
|
||||
60 00 08 00 90 00 00 54 00 30 10 40 08 00:00:33.709 READ FPDMA QUEUED
|
||||
60 00 08 00 88 00 00 21 05 d8 00 40 08 00:00:33.673 READ FPDMA QUEUED
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Extended offline Completed without error 00% 8842 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
@@ -131,8 +180,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 29 Celsius
|
||||
Power Cycle Min/Max Temperature: 29/29 Celsius
|
||||
Current Temperature: 34 Celsius
|
||||
Power Cycle Min/Max Temperature: 33/35 Celsius
|
||||
Lifetime Min/Max Temperature: 16/50 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
@@ -144,7 +193,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (85)
|
||||
Temperature History Size (Index): 478 (101)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 70 (7.0 seconds)
|
||||
@@ -164,12 +213,12 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 3 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 5 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 21 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 23 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 707 Vendor specific
|
||||
0x8000 4 23624 Vendor specific
|
||||
|
||||
|
||||
|
||||
|
@@ -12,7 +12,7 @@ Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat Dec 18 06:56:30 2021 UTC
|
||||
Local Time is: Thu Dec 23 01:47:17 2021 UTC
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -64,17 +64,17 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 145 138 021 - 3725
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 17
|
||||
3 Spin_Up_Time POS--K 144 138 021 - 3758
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 18
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 099 099 000 - 925
|
||||
9 Power_On_Hours -O--CK 099 099 000 - 1036
|
||||
10 Spin_Retry_Count -O--CK 100 253 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 253 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 16
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 17
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 13
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 3
|
||||
194 Temperature_Celsius -O---K 112 111 000 - 31
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 4
|
||||
194 Temperature_Celsius -O---K 114 111 000 - 29
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 253 000 - 0
|
||||
@@ -131,9 +131,9 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 31 Celsius
|
||||
Power Cycle Min/Max Temperature: 23/31 Celsius
|
||||
Lifetime Min/Max Temperature: 21/32 Celsius
|
||||
Current Temperature: 29 Celsius
|
||||
Power Cycle Min/Max Temperature: 22/29 Celsius
|
||||
Lifetime Min/Max Temperature: 22/32 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
@@ -144,7 +144,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (82)
|
||||
Temperature History Size (Index): 478 (62)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 70 (7.0 seconds)
|
||||
@@ -164,10 +164,10 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 38 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 18 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 6 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 6680 Vendor specific
|
||||
0x8000 4 10570 Vendor specific
|
||||
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.2-RELEASE-p6 amd64] (local build)
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.2-RELEASE-p9 amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -12,8 +12,8 @@ Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5400 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Wed Jul 21 18:58:57 2021 EDT
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sun Oct 17 02:29:43 2021 EDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -64,17 +64,17 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 141 134 021 - 3941
|
||||
4 Start_Stop_Count -O--CK 092 092 000 - 8811
|
||||
3 Spin_Up_Time POS--K 140 134 021 - 3991
|
||||
4 Start_Stop_Count -O--CK 092 092 000 - 8848
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 065 065 000 - 25695
|
||||
9 Power_On_Hours -O--CK 063 063 000 - 27692
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 161
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 128
|
||||
193 Load_Cycle_Count -O--CK 198 198 000 - 8719
|
||||
194 Temperature_Celsius -O---K 112 084 000 - 31
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 198
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 159
|
||||
193 Load_Cycle_Count -O--CK 198 198 000 - 8726
|
||||
194 Temperature_Celsius -O---K 111 084 000 - 32
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 253 000 - 0
|
||||
@@ -115,24 +115,24 @@ No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 25676 -
|
||||
# 2 Short offline Completed without error 00% 25652 -
|
||||
# 3 Short offline Completed without error 00% 25628 -
|
||||
# 4 Short offline Completed without error 00% 25604 -
|
||||
# 5 Short offline Completed without error 00% 25580 -
|
||||
# 6 Short offline Completed without error 00% 25556 -
|
||||
# 7 Short offline Completed without error 00% 25532 -
|
||||
# 8 Short offline Completed without error 00% 25508 -
|
||||
# 9 Short offline Completed without error 00% 25484 -
|
||||
#10 Short offline Completed without error 00% 25460 -
|
||||
#11 Short offline Completed without error 00% 25436 -
|
||||
#12 Short offline Completed without error 00% 25412 -
|
||||
#13 Short offline Completed without error 00% 25388 -
|
||||
#14 Short offline Completed without error 00% 25364 -
|
||||
#15 Short offline Completed without error 00% 25340 -
|
||||
#16 Short offline Completed without error 00% 25316 -
|
||||
#17 Short offline Completed without error 00% 25292 -
|
||||
#18 Short offline Completed without error 00% 25268 -
|
||||
# 1 Short offline Completed without error 00% 27689 -
|
||||
# 2 Short offline Completed without error 00% 27665 -
|
||||
# 3 Short offline Completed without error 00% 27642 -
|
||||
# 4 Short offline Completed without error 00% 27618 -
|
||||
# 5 Short offline Completed without error 00% 27594 -
|
||||
# 6 Short offline Completed without error 00% 27570 -
|
||||
# 7 Short offline Completed without error 00% 27546 -
|
||||
# 8 Short offline Completed without error 00% 27522 -
|
||||
# 9 Short offline Completed without error 00% 27498 -
|
||||
#10 Short offline Completed without error 00% 27474 -
|
||||
#11 Short offline Completed without error 00% 27450 -
|
||||
#12 Short offline Completed without error 00% 27426 -
|
||||
#13 Short offline Completed without error 00% 27402 -
|
||||
#14 Short offline Completed without error 00% 27378 -
|
||||
#15 Short offline Completed without error 00% 27354 -
|
||||
#16 Short offline Completed without error 00% 27330 -
|
||||
#17 Short offline Completed without error 00% 27306 -
|
||||
#18 Short offline Completed without error 00% 27282 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
@@ -148,8 +148,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 31 Celsius
|
||||
Power Cycle Min/Max Temperature: 29/48 Celsius
|
||||
Current Temperature: 32 Celsius
|
||||
Power Cycle Min/Max Temperature: 25/46 Celsius
|
||||
Lifetime Min/Max Temperature: 2/59 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
@@ -161,7 +161,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (109)
|
||||
Temperature History Size (Index): 478 (321)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -179,12 +179,12 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 5 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 5 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 8 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 9 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 1935421 Vendor specific
|
||||
0x8000 4 5095917 Vendor specific
|
||||
|
||||
|
||||
|
||||
|
@@ -12,7 +12,7 @@ Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Mon Aug 8 14:36:37 2022 CEST
|
||||
Local Time is: Wed Aug 17 10:34:31 2022 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -63,16 +63,16 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 175 171 021 - 2208
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 102
|
||||
3 Spin_Up_Time POS--K 176 171 021 - 2191
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 113
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 076 076 000 - 18067
|
||||
9 Power_On_Hours -O--CK 076 076 000 - 18190
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 102
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 69
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 32
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 113
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 71
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 41
|
||||
194 Temperature_Celsius -O---K 107 101 000 - 36
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
@@ -131,8 +131,8 @@ SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 36 Celsius
|
||||
Power Cycle Min/Max Temperature: 24/36 Celsius
|
||||
Lifetime Min/Max Temperature: 24/42 Celsius
|
||||
Power Cycle Min/Max Temperature: 25/36 Celsius
|
||||
Lifetime Min/Max Temperature: 25/42 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
@@ -143,7 +143,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (90)
|
||||
Temperature History Size (Index): 478 (307)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -161,10 +161,10 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 4 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 10 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 4 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 15936 Vendor specific
|
||||
0x8000 4 6132 Vendor specific
|
||||
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.2-RELEASE-p4 amd64] (local build)
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RC2 amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -14,7 +14,7 @@ Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 3b
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat Mar 13 18:26:15 2021 CET
|
||||
Local Time is: Tue Mar 16 22:02:07 2021 CET
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,17 +65,17 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 171 167 021 - 2433
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 883
|
||||
3 Spin_Up_Time POS--K 171 167 021 - 2425
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 894
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 097 097 000 - 2399
|
||||
9 Power_On_Hours -O--CK 097 097 000 - 2413
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 883
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 894
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 76
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 1038
|
||||
194 Temperature_Celsius -O---K 112 106 000 - 31
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 1062
|
||||
194 Temperature_Celsius -O---K 111 106 000 - 32
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
@@ -132,8 +132,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 31 Celsius
|
||||
Power Cycle Min/Max Temperature: 20/31 Celsius
|
||||
Current Temperature: 32 Celsius
|
||||
Power Cycle Min/Max Temperature: 22/32 Celsius
|
||||
Lifetime Min/Max Temperature: 11/36 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
@@ -145,7 +145,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (385)
|
||||
Temperature History Size (Index): 478 (238)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -163,13 +163,13 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 4 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 5 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 5 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 6 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 4815 Vendor specific
|
||||
0x8000 4 3175 Vendor specific
|
||||
|
||||
|
||||
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p13-HBSD amd64] (local build)
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p15-HBSD amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -13,8 +13,8 @@ Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 3b
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Tue Mar 2 00:11:05 2021 PST
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Tue Apr 6 17:42:38 2021 PDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,17 +65,17 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 171 170 021 - 2433
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 908
|
||||
3 Spin_Up_Time POS--K 172 170 021 - 2383
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 956
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 094 094 000 - 4866
|
||||
9 Power_On_Hours -O--CK 093 093 000 - 5124
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 745
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 140
|
||||
193 Load_Cycle_Count -O--CK 199 199 000 - 3416
|
||||
194 Temperature_Celsius -O---K 108 103 000 - 35
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 791
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 146
|
||||
193 Load_Cycle_Count -O--CK 199 199 000 - 3507
|
||||
194 Temperature_Celsius -O---K 112 103 000 - 31
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
@@ -132,8 +132,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 35 Celsius
|
||||
Power Cycle Min/Max Temperature: 21/36 Celsius
|
||||
Current Temperature: 31 Celsius
|
||||
Power Cycle Min/Max Temperature: 29/32 Celsius
|
||||
Lifetime Min/Max Temperature: 20/40 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
@@ -145,7 +145,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (385)
|
||||
Temperature History Size (Index): 478 (88)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -163,13 +163,11 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 8 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x0009 2 18 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 22 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 50438 Vendor specific
|
||||
|
||||
|
||||
0x8000 4 6560 Vendor specific
|
||||
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-CURRENT amd64] (local build)
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -14,7 +14,7 @@ Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 3b
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Wed Feb 17 11:18:22 2021 EST
|
||||
Local Time is: Thu Oct 7 19:31:09 2021 EDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,25 +65,25 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 173 173 021 - 2308
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 336
|
||||
3 Spin_Up_Time POS--K 174 170 021 - 2300
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 848
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 098 098 000 - 1797
|
||||
9 Power_On_Hours -O--CK 093 093 000 - 5116
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 336
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 8
|
||||
193 Load_Cycle_Count -O--CK 185 185 000 - 45062
|
||||
194 Temperature_Celsius -O---K 104 097 000 - 39
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 806
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 57
|
||||
193 Load_Cycle_Count -O--CK 134 134 000 - 198282
|
||||
194 Temperature_Celsius -O---K 103 097 000 - 40
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate ---R-- 200 200 000 - 0
|
||||
240 Head_Flying_Hours -O--CK 098 098 000 - 1552
|
||||
241 Total_LBAs_Written -O--CK 200 200 000 - 14059109351
|
||||
242 Total_LBAs_Read -O--CK 200 200 000 - 10329679496
|
||||
240 Head_Flying_Hours -O--CK 095 095 000 - 3656
|
||||
241 Total_LBAs_Written -O--CK 200 200 000 - 40711702885
|
||||
242 Total_LBAs_Read -O--CK 200 200 000 - 24650381021
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -119,8 +119,9 @@ No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 1710 -
|
||||
# 2 Short offline Completed without error 00% 1697 -
|
||||
# 1 Short offline Completed without error 00% 3904 -
|
||||
# 2 Short offline Completed without error 00% 1710 -
|
||||
# 3 Short offline Completed without error 00% 1697 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
@@ -136,9 +137,9 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 39 Celsius
|
||||
Power Cycle Min/Max Temperature: 27/41 Celsius
|
||||
Lifetime Min/Max Temperature: 23/46 Celsius
|
||||
Current Temperature: 41 Celsius
|
||||
Power Cycle Min/Max Temperature: 33/41 Celsius
|
||||
Lifetime Min/Max Temperature: 18/47 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
@@ -149,7 +150,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (421)
|
||||
Temperature History Size (Index): 478 (454)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -167,11 +168,11 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 7 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 9 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 3 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 5 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 14077 Vendor specific
|
||||
0x8000 4 8751 Vendor specific
|
||||
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-STABLE amd64] (local build)
|
||||
smartctl 7.2 2021-09-14 r5236 [FreeBSD 13.0-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -13,7 +13,7 @@ Rotation Rate: 5400 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Fri Mar 26 20:32:55 2021 CET
|
||||
Local Time is: Thu Dec 9 18:28:00 2021 CET
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -64,16 +64,16 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 140 138 021 - 3966
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 364
|
||||
3 Spin_Up_Time POS--K 140 138 021 - 4000
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 380
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 059 059 000 - 30641
|
||||
9 Power_On_Hours -O--CK 051 051 000 - 35816
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 357
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 319
|
||||
193 Load_Cycle_Count -O--CK 106 106 000 - 283311
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 373
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 328
|
||||
193 Load_Cycle_Count -O--CK 104 104 000 - 288331
|
||||
194 Temperature_Celsius -O---K 115 096 000 - 28
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
@@ -113,24 +113,24 @@ No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 30432 -
|
||||
# 2 Short offline Completed without error 00% 29761 -
|
||||
# 3 Short offline Completed without error 00% 29258 -
|
||||
# 4 Short offline Completed without error 00% 26572 -
|
||||
# 5 Short offline Completed without error 00% 24345 -
|
||||
# 6 Short offline Completed without error 00% 23841 -
|
||||
# 7 Short offline Completed without error 00% 19509 -
|
||||
# 8 Short offline Completed without error 00% 15031 -
|
||||
# 9 Short offline Completed without error 00% 14529 -
|
||||
#10 Short offline Completed without error 00% 14009 -
|
||||
#11 Short offline Completed without error 00% 11404 -
|
||||
#12 Short offline Completed without error 00% 10900 -
|
||||
#13 Short offline Completed without error 00% 9014 -
|
||||
#14 Short offline Completed without error 00% 6364 -
|
||||
#15 Short offline Completed without error 00% 5709 -
|
||||
#16 Extended offline Completed without error 00% 5462 -
|
||||
#17 Short offline Completed without error 00% 5435 -
|
||||
#18 Conveyance offline Completed without error 00% 5435 -
|
||||
# 1 Short offline Completed without error 00% 35298 -
|
||||
# 2 Short offline Completed without error 00% 34793 -
|
||||
# 3 Short offline Completed without error 00% 30935 -
|
||||
# 4 Short offline Completed without error 00% 30432 -
|
||||
# 5 Short offline Completed without error 00% 29761 -
|
||||
# 6 Short offline Completed without error 00% 29258 -
|
||||
# 7 Short offline Completed without error 00% 26572 -
|
||||
# 8 Short offline Completed without error 00% 24345 -
|
||||
# 9 Short offline Completed without error 00% 23841 -
|
||||
#10 Short offline Completed without error 00% 19509 -
|
||||
#11 Short offline Completed without error 00% 15031 -
|
||||
#12 Short offline Completed without error 00% 14529 -
|
||||
#13 Short offline Completed without error 00% 14009 -
|
||||
#14 Short offline Completed without error 00% 11404 -
|
||||
#15 Short offline Completed without error 00% 10900 -
|
||||
#16 Short offline Completed without error 00% 9014 -
|
||||
#17 Short offline Completed without error 00% 6364 -
|
||||
#18 Short offline Completed without error 00% 5709 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
@@ -147,7 +147,7 @@ SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 28 Celsius
|
||||
Power Cycle Min/Max Temperature: 21/28 Celsius
|
||||
Power Cycle Min/Max Temperature: 23/36 Celsius
|
||||
Lifetime Min/Max Temperature: 17/47 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
@@ -159,7 +159,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (115)
|
||||
Temperature History Size (Index): 478 (177)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -177,12 +177,12 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 34 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 34 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 24 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 24 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 3107384 Vendor specific
|
||||
0x8000 4 8510626 Vendor specific
|
||||
|
||||
|
||||
|
||||
|
@@ -12,7 +12,7 @@ Rotation Rate: 5400 rpm
|
||||
Device is: Not in smartctl database 7.3/5319
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sun Jan 8 19:59:44 2023 CET
|
||||
Local Time is: Sun Jan 8 20:19:48 2023 CET
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
|
||||
@@ -58,17 +58,17 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
|
||||
1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always - 0
|
||||
3 Spin_Up_Time 0x0027 181 178 021 Pre-fail Always - 1916
|
||||
4 Start_Stop_Count 0x0032 001 001 000 Old_age Always - 190434
|
||||
3 Spin_Up_Time 0x0027 182 178 021 Pre-fail Always - 1900
|
||||
4 Start_Stop_Count 0x0032 001 001 000 Old_age Always - 190439
|
||||
5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0
|
||||
7 Seek_Error_Rate 0x002f 200 200 051 Pre-fail Always - 0
|
||||
9 Power_On_Hours 0x0032 086 086 000 Old_age Always - 10446
|
||||
10 Spin_Retry_Count 0x0032 100 100 000 Old_age Always - 0
|
||||
11 Calibration_Retry_Count 0x0032 100 100 000 Old_age Always - 0
|
||||
12 Power_Cycle_Count 0x0032 097 097 000 Old_age Always - 3189
|
||||
192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 133
|
||||
193 Load_Cycle_Count 0x0032 109 109 000 Old_age Always - 275132
|
||||
194 Temperature_Celsius 0x0022 128 101 000 Old_age Always - 19
|
||||
12 Power_Cycle_Count 0x0032 097 097 000 Old_age Always - 3190
|
||||
192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 134
|
||||
193 Load_Cycle_Count 0x0032 109 109 000 Old_age Always - 275136
|
||||
194 Temperature_Celsius 0x0022 123 101 000 Old_age Always - 24
|
||||
196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
|
||||
197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 0
|
||||
198 Offline_Uncorrectable 0x0030 100 253 000 Old_age Offline - 0
|
||||
|
@@ -1,5 +1,5 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [x86_64-unknown-openbsd6.9] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
smartctl 7.2 2020-12-30 r5155 [OpenBSD 7.0 amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Western Digital Black Mobile
|
||||
@@ -14,7 +14,7 @@ Form Factor: 2.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Mon May 17 18:00:02 2021 EDT
|
||||
Local Time is: Mon Oct 18 01:41:20 2021 EDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
|
||||
@@ -59,17 +59,17 @@ Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
|
||||
1 Raw_Read_Error_Rate 0x000b 100 100 062 Pre-fail Always - 0
|
||||
2 Throughput_Performance 0x0005 100 100 040 Pre-fail Offline - 0
|
||||
3 Spin_Up_Time 0x0007 225 225 033 Pre-fail Always - 0
|
||||
4 Start_Stop_Count 0x0012 100 100 000 Old_age Always - 545
|
||||
3 Spin_Up_Time 0x0007 253 253 033 Pre-fail Always - 0
|
||||
4 Start_Stop_Count 0x0012 100 100 000 Old_age Always - 706
|
||||
5 Reallocated_Sector_Ct 0x0033 100 100 005 Pre-fail Always - 0
|
||||
7 Seek_Error_Rate 0x000b 100 100 067 Pre-fail Always - 0
|
||||
8 Seek_Time_Performance 0x0005 100 100 040 Pre-fail Offline - 0
|
||||
9 Power_On_Hours 0x0012 100 100 000 Old_age Always - 166
|
||||
9 Power_On_Hours 0x0012 100 100 000 Old_age Always - 228
|
||||
10 Spin_Retry_Count 0x0013 100 100 060 Pre-fail Always - 0
|
||||
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 95
|
||||
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 118
|
||||
191 G-Sense_Error_Rate 0x000a 100 100 000 Old_age Always - 0
|
||||
192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 8
|
||||
193 Load_Cycle_Count 0x0012 100 100 000 Old_age Always - 3154
|
||||
193 Load_Cycle_Count 0x0012 100 100 000 Old_age Always - 3758
|
||||
194 Temperature_Celsius 0x0002 139 139 000 Old_age Always - 43 (Min/Max 22/58)
|
||||
196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 0
|
||||
197 Current_Pending_Sector 0x0022 100 100 000 Old_age Always - 0
|
||||
|
@@ -1,5 +1,5 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RELEASE-p4 amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Western Digital Blue Mobile
|
||||
@@ -10,10 +10,10 @@ Firmware Version: 01.01A01
|
||||
User Capacity: 1,000,204,886,016 bytes [1.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5400 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Tue Nov 23 22:30:08 2021 CAT
|
||||
Local Time is: Fri Jul 29 12:43:58 2022 CAT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -64,18 +64,18 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 182 176 021 - 1866
|
||||
4 Start_Stop_Count -O--CK 028 028 000 - 72086
|
||||
3 Spin_Up_Time POS--K 182 176 021 - 1875
|
||||
4 Start_Stop_Count -O--CK 001 001 000 - 145543
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 087 087 000 - 9785
|
||||
9 Power_On_Hours -O--CK 080 080 000 - 14744
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 1281
|
||||
191 G-Sense_Error_Rate -O--CK 017 017 000 - 83
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 91
|
||||
193 Load_Cycle_Count -O--CK 080 080 000 - 361480
|
||||
194 Temperature_Celsius -O---K 110 094 000 - 37
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 1461
|
||||
191 G-Sense_Error_Rate -O--CK 001 001 000 - 128
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 151
|
||||
193 Load_Cycle_Count -O--CK 006 006 000 - 583120
|
||||
194 Temperature_Celsius -O---K 116 094 000 - 31
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 253 000 - 0
|
||||
@@ -115,24 +115,24 @@ No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 4580 -
|
||||
# 2 Short offline Completed without error 00% 4556 -
|
||||
# 3 Short offline Completed without error 00% 4533 -
|
||||
# 4 Short offline Completed without error 00% 4509 -
|
||||
# 5 Short offline Completed without error 00% 4486 -
|
||||
# 6 Short offline Completed without error 00% 4462 -
|
||||
# 7 Short offline Completed without error 00% 4438 -
|
||||
# 8 Short offline Completed without error 00% 4414 -
|
||||
# 9 Short offline Completed without error 00% 4390 -
|
||||
#10 Short offline Completed without error 00% 4367 -
|
||||
#11 Short offline Completed without error 00% 4343 -
|
||||
#12 Short offline Completed without error 00% 4319 -
|
||||
#13 Short offline Completed without error 00% 4295 -
|
||||
#14 Short offline Completed without error 00% 4271 -
|
||||
#15 Short offline Completed without error 00% 4247 -
|
||||
#16 Short offline Completed without error 00% 4234 -
|
||||
#17 Short offline Completed without error 00% 4223 -
|
||||
#18 Short offline Completed without error 00% 4212 -
|
||||
# 1 Short offline Completed without error 00% 13720 -
|
||||
# 2 Short offline Completed without error 00% 13696 -
|
||||
# 3 Short offline Completed without error 00% 13672 -
|
||||
# 4 Short offline Completed without error 00% 13648 -
|
||||
# 5 Short offline Completed without error 00% 13624 -
|
||||
# 6 Short offline Completed without error 00% 13600 -
|
||||
# 7 Short offline Completed without error 00% 13576 -
|
||||
# 8 Short offline Completed without error 00% 13552 -
|
||||
# 9 Extended offline Completed without error 00% 13529 -
|
||||
#10 Short offline Completed without error 00% 13504 -
|
||||
#11 Short offline Completed without error 00% 13480 -
|
||||
#12 Short offline Completed without error 00% 13457 -
|
||||
#13 Short offline Completed without error 00% 13435 -
|
||||
#14 Short offline Completed without error 00% 13411 -
|
||||
#15 Short offline Completed without error 00% 13387 -
|
||||
#16 Short offline Completed without error 00% 13363 -
|
||||
#17 Short offline Completed without error 00% 13339 -
|
||||
#18 Short offline Completed without error 00% 13315 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
@@ -148,8 +148,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 37 Celsius
|
||||
Power Cycle Min/Max Temperature: 24/42 Celsius
|
||||
Current Temperature: 31 Celsius
|
||||
Power Cycle Min/Max Temperature: 27/40 Celsius
|
||||
Lifetime Min/Max Temperature: 12/53 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
@@ -161,7 +161,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 128 (86)
|
||||
Temperature History Size (Index): 128 (75)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -179,10 +179,10 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 34 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 31 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 35 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 35 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 304258 Vendor specific
|
||||
0x8000 4 68460 Vendor specific
|
||||
|
||||
|
@@ -14,7 +14,7 @@ Form Factor: 2.5 inches
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Mon Apr 11 17:10:40 2022 AEST
|
||||
Local Time is: Tue Apr 19 11:35:24 2022 AEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -67,7 +67,7 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
4 Start_Stop_Count -O--CK 099 099 000 - 1101
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate POSR-K 200 200 051 - 0
|
||||
9 Power_On_Hours -O--CK 089 089 000 - 8117
|
||||
9 Power_On_Hours -O--CK 089 089 000 - 8304
|
||||
10 Spin_Retry_Count PO--CK 100 100 051 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 1097
|
||||
@@ -75,11 +75,11 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
184 End-to-End_Error PO--CK 100 100 097 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 099 000 - 1
|
||||
190 Airflow_Temperature_Cel -O---K 069 056 040 - 31 (Min/Max 28/36)
|
||||
190 Airflow_Temperature_Cel -O---K 071 056 040 - 29 (Min/Max 28/36)
|
||||
191 G-Sense_Error_Rate -O--CK 001 001 000 - 118
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 336
|
||||
193 Load_Cycle_Count -O--CK 001 001 000 - 1037282
|
||||
194 Temperature_Celsius -O---K 116 103 000 - 31
|
||||
193 Load_Cycle_Count -O--CK 001 001 000 - 1050626
|
||||
194 Temperature_Celsius -O---K 118 103 000 - 29
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 253 000 - 0
|
||||
@@ -136,7 +136,7 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 31 Celsius
|
||||
Current Temperature: 29 Celsius
|
||||
Power Cycle Min/Max Temperature: 28/36 Celsius
|
||||
Lifetime Min/Max Temperature: 13/44 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
@@ -149,7 +149,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 128 (74)
|
||||
Temperature History Size (Index): 128 (107)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 85 (8.5 seconds)
|
||||
@@ -169,10 +169,10 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 35 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 35 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 43 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 43 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 2323018 Vendor specific
|
||||
0x8000 4 2993435 Vendor specific
|
||||
|
||||
|
@@ -13,7 +13,7 @@ Rotation Rate: 5400 rpm
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 3.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Wed Jul 13 17:08:51 2022 EDT
|
||||
Local Time is: Thu Jul 14 21:34:39 2022 EDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -67,16 +67,16 @@ Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 189 182 021 - 1541
|
||||
4 Start_Stop_Count -O--CK 075 075 000 - 25780
|
||||
4 Start_Stop_Count -O--CK 075 075 000 - 25790
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 073 073 000 - 20265
|
||||
9 Power_On_Hours -O--CK 073 073 000 - 20266
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 075 075 000 - 25677
|
||||
12 Power_Cycle_Count -O--CK 075 075 000 - 25680
|
||||
191 G-Sense_Error_Rate -O--CK 095 095 000 - 5
|
||||
192 Power-Off_Retract_Count -O--CK 166 166 000 - 25634
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 2060
|
||||
192 Power-Off_Retract_Count -O--CK 166 166 000 - 25636
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 2068
|
||||
194 Temperature_Celsius -O---K 121 095 000 - 26
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
@@ -155,7 +155,7 @@ SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 26 Celsius
|
||||
Power Cycle Min/Max Temperature: 22/26 Celsius
|
||||
Power Cycle Min/Max Temperature: 23/26 Celsius
|
||||
Lifetime Min/Max Temperature: 11/52 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
@@ -167,23 +167,23 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/65 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (245)
|
||||
Temperature History Size (Index): 478 (352)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 25677 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 20265 --- Power-on Hours
|
||||
0x01 0x018 6 22091094383 --- Logical Sectors Written
|
||||
0x01 0x020 6 72366578 --- Number of Write Commands
|
||||
0x01 0x028 6 7047696172 --- Logical Sectors Read
|
||||
0x01 0x030 6 459732781 --- Number of Read Commands
|
||||
0x01 0x008 4 25680 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 20266 --- Power-on Hours
|
||||
0x01 0x018 6 22091103657 --- Logical Sectors Written
|
||||
0x01 0x020 6 72366685 --- Number of Write Commands
|
||||
0x01 0x028 6 7047774107 --- Logical Sectors Read
|
||||
0x01 0x030 6 459734513 --- Number of Read Commands
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 20142 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 3417 --- Head Flying Hours
|
||||
0x03 0x018 4 27695 --- Head Load Events
|
||||
0x03 0x008 4 20143 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 3419 --- Head Flying Hours
|
||||
0x03 0x018 4 27705 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 2 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
@@ -205,8 +205,8 @@ Page Offset Size Value Flags Description
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 26444 --- Number of Hardware Resets
|
||||
0x06 0x010 4 3235022 --- Number of ASR Events
|
||||
0x06 0x008 4 26461 --- Number of Hardware Resets
|
||||
0x06 0x010 4 3294904 --- Number of ASR Events
|
||||
0x06 0x018 4 1 --- Number of Interface CRC Errors
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
@@ -225,11 +225,11 @@ ID Size Value Description
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 5 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 6 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000a 2 5 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 568 Vendor specific
|
||||
0x8000 4 379 Vendor specific
|
||||
|
||||
|
||||
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.2-RELEASE-p4 amd64] (local build)
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RELEASE-p3 amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -14,7 +14,7 @@ TRIM Command: Available, deterministic
|
||||
Device is: Not in smartctl database [for details use: -P showall]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Wed Mar 3 14:18:01 2021 CET
|
||||
Local Time is: Mon Jul 12 09:16:19 2021 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -36,7 +36,7 @@ Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 480) seconds.
|
||||
data collection: ( 540) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x51) SMART execute Offline immediate.
|
||||
No Auto Offline data collection support.
|
||||
@@ -63,17 +63,17 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 253 051 - 0
|
||||
3 Spin_Up_Time POS--K 170 165 021 - 2458
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 32
|
||||
3 Spin_Up_Time POS--K 172 165 021 - 2391
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 72
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 097 097 000 - 2874
|
||||
9 Power_On_Hours -O--CK 094 094 000 - 5049
|
||||
10 Spin_Retry_Count -O--CK 100 253 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 253 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 6
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 1
|
||||
193 Load_Cycle_Count -O--CK 142 142 000 - 174185
|
||||
194 Temperature_Celsius -O---K 106 097 000 - 37
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 18
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 6
|
||||
193 Load_Cycle_Count -O--CK 108 108 000 - 277088
|
||||
194 Temperature_Celsius -O---K 097 091 000 - 46
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 253 000 - 0
|
||||
@@ -132,9 +132,9 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 37 Celsius
|
||||
Power Cycle Min/Max Temperature: 30/46 Celsius
|
||||
Lifetime Min/Max Temperature: 21/46 Celsius
|
||||
Current Temperature: 46 Celsius
|
||||
Power Cycle Min/Max Temperature: 35/52 Celsius
|
||||
Lifetime Min/Max Temperature: 21/52 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
@@ -145,7 +145,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 128 (115)
|
||||
Temperature History Size (Index): 128 (114)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -163,13 +163,11 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 8 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 10 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 41 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 42 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 706734 Vendor specific
|
||||
|
||||
|
||||
0x8000 4 4478155 Vendor specific
|
||||
|
||||
|
@@ -1,5 +1,5 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-ALPHA2 amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Western Digital Blue Mobile (SMR)
|
||||
@@ -12,10 +12,10 @@ Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5400 rpm
|
||||
Form Factor: 2.5 inches
|
||||
TRIM Command: Available, deterministic
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Thu Feb 4 13:13:01 2021 CET
|
||||
Local Time is: Tue May 31 10:29:24 2022 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -37,7 +37,7 @@ Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: (10800) seconds.
|
||||
data collection: (11400) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x71) SMART execute Offline immediate.
|
||||
No Auto Offline data collection support.
|
||||
@@ -55,7 +55,7 @@ Error logging capability: (0x01) Error logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 457) minutes.
|
||||
recommended polling time: ( 412) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
SCT capabilities: (0x3035) SCT Status supported.
|
||||
@@ -66,18 +66,18 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 196 189 021 - 1200
|
||||
4 Start_Stop_Count -O--CK 001 001 000 - 201960
|
||||
3 Spin_Up_Time POS--K 189 188 021 - 1508
|
||||
4 Start_Stop_Count -O--CK 001 001 000 - 219137
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 085 085 000 - 10950
|
||||
9 Power_On_Hours -O--CK 075 075 000 - 18496
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 922
|
||||
191 G-Sense_Error_Rate -O--CK 001 001 000 - 35064
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 158
|
||||
193 Load_Cycle_Count -O--CK 001 001 000 - 640573
|
||||
194 Temperature_Celsius -O---K 103 094 000 - 40
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 1277
|
||||
191 G-Sense_Error_Rate -O--CK 001 001 000 - 65068
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 208
|
||||
193 Load_Cycle_Count -O--CK 001 001 000 - 780462
|
||||
194 Temperature_Celsius -O---K 105 094 000 - 38
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
@@ -119,24 +119,24 @@ No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 10939 -
|
||||
# 2 Short offline Completed without error 00% 10915 -
|
||||
# 3 Short offline Completed without error 00% 10891 -
|
||||
# 4 Short offline Completed without error 00% 10867 -
|
||||
# 5 Short offline Completed without error 00% 10843 -
|
||||
# 6 Extended offline Completed without error 00% 10829 -
|
||||
# 7 Short offline Completed without error 00% 10819 -
|
||||
# 8 Short offline Completed without error 00% 10795 -
|
||||
# 9 Short offline Completed without error 00% 10772 -
|
||||
#10 Short offline Completed without error 00% 10747 -
|
||||
#11 Short offline Completed without error 00% 10723 -
|
||||
#12 Short offline Completed without error 00% 10700 -
|
||||
#13 Short offline Completed without error 00% 10676 -
|
||||
#14 Extended offline Interrupted (host reset) 10% 10659 -
|
||||
#15 Short offline Completed without error 00% 10651 -
|
||||
#16 Short offline Completed without error 00% 10618 -
|
||||
#17 Short offline Completed without error 00% 10594 -
|
||||
#18 Short offline Completed without error 00% 10570 -
|
||||
# 1 Extended offline Completed without error 00% 18458 -
|
||||
# 2 Short offline Completed without error 00% 18451 -
|
||||
# 3 Short offline Completed without error 00% 18427 -
|
||||
# 4 Short offline Completed without error 00% 18383 -
|
||||
# 5 Extended offline Completed without error 00% 18341 -
|
||||
# 6 Short offline Completed without error 00% 18334 -
|
||||
# 7 Short offline Completed without error 00% 18310 -
|
||||
# 8 Short offline Completed without error 00% 18264 -
|
||||
# 9 Short offline Completed without error 00% 18213 -
|
||||
#10 Short offline Completed without error 00% 18177 -
|
||||
#11 Extended offline Completed without error 00% 18122 -
|
||||
#12 Short offline Completed without error 00% 18114 -
|
||||
#13 Short offline Completed without error 00% 18090 -
|
||||
#14 Short offline Completed without error 00% 18066 -
|
||||
#15 Short offline Completed without error 00% 18042 -
|
||||
#16 Short offline Completed without error 00% 17992 -
|
||||
#17 Short offline Completed without error 00% 17953 -
|
||||
#18 Short offline Completed without error 00% 17940 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
@@ -152,9 +152,9 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 40 Celsius
|
||||
Power Cycle Min/Max Temperature: 30/41 Celsius
|
||||
Lifetime Min/Max Temperature: 20/49 Celsius
|
||||
Current Temperature: 38 Celsius
|
||||
Power Cycle Min/Max Temperature: 19/39 Celsius
|
||||
Lifetime Min/Max Temperature: 17/49 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
@@ -165,7 +165,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 128 (41)
|
||||
Temperature History Size (Index): 128 (118)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -183,13 +183,13 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 7 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 8 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 3 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 4 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 603394 Vendor specific
|
||||
0x8000 4 9512 Vendor specific
|
||||
|
||||
|
||||
|
||||
|
@@ -14,7 +14,7 @@ Form Factor: 2.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Thu Oct 29 08:35:56 2020 +0330
|
||||
Local Time is: Thu Oct 29 09:27:09 2020 +0330
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -66,18 +66,18 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 195 193 021 - 1208
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 375
|
||||
3 Spin_Up_Time POS--K 195 193 021 - 1250
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 388
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 94
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 95
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 171
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 31
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 920
|
||||
194 Temperature_Celsius -O---K 111 102 000 - 32 (Min/Max 16/41)
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 999
|
||||
194 Temperature_Celsius -O---K 109 102 000 - 34 (Min/Max 16/41)
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 253 000 - 0
|
||||
@@ -138,7 +138,7 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 32 Celsius
|
||||
Current Temperature: 34 Celsius
|
||||
Power Cycle Min/Max Temperature: 24/34 Celsius
|
||||
Lifetime Min/Max Temperature: 16/41 Celsius
|
||||
Specified Max Operating Temperature: 33 Celsius
|
||||
@@ -152,7 +152,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 128 (125)
|
||||
Temperature History Size (Index): 128 (72)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 150 (15.0 seconds)
|
||||
@@ -172,13 +172,13 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 6 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 7 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 18 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 19 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 3346 Vendor specific
|
||||
0x8000 4 6415 Vendor specific
|
||||
|
||||
|
||||
|
||||
|
Reference in New Issue