smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.2-RELEASE-p7 amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p2 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Western Digital Red
|
||||
@@ -10,10 +10,10 @@ Firmware Version: 82.00A82
|
||||
User Capacity: 3,000,592,982,016 bytes [3.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5400 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Sun Jul 4 00:51:30 2021 EEST
|
||||
Local Time is: Wed Oct 12 09:56:17 2022 EEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,17 +65,17 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 180 174 021 - 5991
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 502
|
||||
3 Spin_Up_Time POS--K 178 174 021 - 6083
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 547
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 053 053 000 - 34353
|
||||
9 Power_On_Hours -O--CK 042 042 000 - 42378
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 399
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 98
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 2197
|
||||
194 Temperature_Celsius -O---K 115 113 000 - 35
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 444
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 117
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 2924
|
||||
194 Temperature_Celsius -O---K 122 113 000 - 28
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 253 000 - 0
|
||||
@@ -131,8 +131,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 35 Celsius
|
||||
Power Cycle Min/Max Temperature: 23/36 Celsius
|
||||
Current Temperature: 28 Celsius
|
||||
Power Cycle Min/Max Temperature: 19/30 Celsius
|
||||
Lifetime Min/Max Temperature: 2/37 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
@@ -144,7 +144,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (239)
|
||||
Temperature History Size (Index): 478 (11)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 70 (7.0 seconds)
|
||||
@@ -169,7 +169,5 @@ ID Size Value Description
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 111779 Vendor specific
|
||||
|
||||
|
||||
0x8000 4 1336264 Vendor specific
|
||||
|
||||
|
@@ -1,5 +1,5 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.2-RELEASE-p7 amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p2 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Western Digital Red
|
||||
@@ -10,10 +10,10 @@ Firmware Version: 82.00A82
|
||||
User Capacity: 3,000,592,982,016 bytes [3.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5400 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sun Jul 4 00:51:30 2021 EEST
|
||||
Local Time is: Wed Oct 12 09:56:17 2022 EEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,17 +65,17 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 43
|
||||
3 Spin_Up_Time POS--K 177 173 021 - 6108
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 672
|
||||
3 Spin_Up_Time POS--K 176 173 021 - 6175
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 717
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 048 048 000 - 38055
|
||||
9 Power_On_Hours -O--CK 037 037 000 - 46080
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 569
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 154
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 2495
|
||||
194 Temperature_Celsius -O---K 115 111 000 - 35
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 614
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 173
|
||||
193 Load_Cycle_Count -O--CK 199 199 000 - 3209
|
||||
194 Temperature_Celsius -O---K 122 111 000 - 28
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 253 000 - 0
|
||||
@@ -132,8 +132,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 35 Celsius
|
||||
Power Cycle Min/Max Temperature: 24/36 Celsius
|
||||
Current Temperature: 28 Celsius
|
||||
Power Cycle Min/Max Temperature: 19/31 Celsius
|
||||
Lifetime Min/Max Temperature: 2/40 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
@@ -145,7 +145,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (467)
|
||||
Temperature History Size (Index): 478 (188)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 70 (7.0 seconds)
|
||||
@@ -170,7 +170,7 @@ ID Size Value Description
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 111779 Vendor specific
|
||||
0x8000 4 1336263 Vendor specific
|
||||
|
||||
|
||||
|
||||
|
@@ -1,5 +1,5 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.2-RELEASE-p7 amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p2 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Western Digital Red
|
||||
@@ -10,10 +10,10 @@ Firmware Version: 82.00A82
|
||||
User Capacity: 3,000,592,982,016 bytes [3.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5400 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sun Jul 4 00:51:30 2021 EEST
|
||||
Local Time is: Wed Oct 12 09:56:17 2022 EEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,17 +65,17 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 179 176 021 - 6025
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 671
|
||||
3 Spin_Up_Time POS--K 179 176 021 - 6050
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 716
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 048 048 000 - 38056
|
||||
9 Power_On_Hours -O--CK 037 037 000 - 46081
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 567
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 151
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 2493
|
||||
194 Temperature_Celsius -O---K 114 108 000 - 36
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 612
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 170
|
||||
193 Load_Cycle_Count -O--CK 199 199 000 - 3207
|
||||
194 Temperature_Celsius -O---K 121 108 000 - 29
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 253 000 - 0
|
||||
@@ -132,8 +132,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 36 Celsius
|
||||
Power Cycle Min/Max Temperature: 24/36 Celsius
|
||||
Current Temperature: 29 Celsius
|
||||
Power Cycle Min/Max Temperature: 19/32 Celsius
|
||||
Lifetime Min/Max Temperature: 2/42 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
@@ -145,7 +145,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (63)
|
||||
Temperature History Size (Index): 478 (261)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 70 (7.0 seconds)
|
||||
@@ -170,7 +170,7 @@ ID Size Value Description
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 111778 Vendor specific
|
||||
0x8000 4 1336258 Vendor specific
|
||||
|
||||
|
||||
|
||||
|
@@ -1,5 +1,5 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.0-RELEASE-p11 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Western Digital Green
|
||||
@@ -10,10 +10,10 @@ Firmware Version: 80.00A80
|
||||
User Capacity: 3,000,592,982,016 bytes [3.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5400 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Thu May 27 09:09:59 2021 CEST
|
||||
Local Time is: Mon Apr 25 07:31:25 2022 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -28,8 +28,8 @@ Wt Cache Reorder: Enabled
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x84) Offline data collection activity
|
||||
was suspended by an interrupting command from host.
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
@@ -64,17 +64,17 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 243 241 021 - 9816
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 329
|
||||
3 Spin_Up_Time POS--K 242 241 021 - 9891
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 387
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 021 021 000 - 58339
|
||||
9 Power_On_Hours -O--CK 011 011 000 - 65390
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 324
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 111
|
||||
193 Load_Cycle_Count -O--CK 001 001 000 - 1132140
|
||||
194 Temperature_Celsius -O---K 120 106 000 - 32
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 382
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 113
|
||||
193 Load_Cycle_Count -O--CK 001 001 000 - 1294542
|
||||
194 Temperature_Celsius -O---K 121 106 000 - 31
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
@@ -130,8 +130,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 32 Celsius
|
||||
Power Cycle Min/Max Temperature: 16/33 Celsius
|
||||
Current Temperature: 31 Celsius
|
||||
Power Cycle Min/Max Temperature: 20/39 Celsius
|
||||
Lifetime Min/Max Temperature: 0/46 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
@@ -140,7 +140,8 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (151)
|
||||
Temperature History Size (Index): 478 (65535)
|
||||
Invalid Temperature History Size or Index
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -158,12 +159,12 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 2 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 17 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 12 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 90316 Vendor specific
|
||||
0x8000 4 9138964 Vendor specific
|
||||
|
||||
|
||||
|
||||
|
@@ -1,5 +1,5 @@
|
||||
smartctl 6.6 2017-11-05 r4594 [FreeBSD 11.2-RELEASE-p2 amd64] (local build)
|
||||
Copyright (C) 2002-17, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p10 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Western Digital Green
|
||||
@@ -12,7 +12,7 @@ Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Wed Aug 19 20:26:30 2020 CEST
|
||||
Local Time is: Thu Oct 1 08:21:29 2020 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -27,8 +27,8 @@ Wt Cache Reorder: Enabled
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x84) Offline data collection activity
|
||||
was suspended by an interrupting command from host.
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
@@ -63,17 +63,17 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 200 172 021 - 4975
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 70
|
||||
3 Spin_Up_Time POS--K 184 172 021 - 5791
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 80
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 057 057 000 - 32001
|
||||
9 Power_On_Hours -O--CK 055 055 000 - 33014
|
||||
10 Spin_Retry_Count -O--CK 100 253 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 253 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 70
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 32
|
||||
193 Load_Cycle_Count -O--CK 012 012 000 - 566441
|
||||
194 Temperature_Celsius -O---K 110 102 000 - 40
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 80
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 39
|
||||
193 Load_Cycle_Count -O--CK 007 007 000 - 579192
|
||||
194 Temperature_Celsius -O---K 115 102 000 - 35
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
@@ -126,10 +126,9 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
SCT Support Level: 1
|
||||
Device State: Active (0)
|
||||
Current Temperature: 40 Celsius
|
||||
Power Cycle Min/Max Temperature: 37/47 Celsius
|
||||
Current Temperature: 35 Celsius
|
||||
Power Cycle Min/Max Temperature: 29/38 Celsius
|
||||
Lifetime Min/Max Temperature: 2/48 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
@@ -141,7 +140,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (460)
|
||||
Temperature History Size (Index): 478 (18)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -164,7 +163,5 @@ ID Size Value Description
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 957097 Vendor specific
|
||||
|
||||
|
||||
0x8000 4 224818 Vendor specific
|
||||
|
||||
|
@@ -1,5 +1,5 @@
|
||||
smartctl 6.6 2017-11-05 r4594 [FreeBSD 11.2-RELEASE-p2 amd64] (local build)
|
||||
Copyright (C) 2002-17, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-RELEASE-p10 amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Western Digital Green
|
||||
@@ -12,7 +12,7 @@ Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Wed Aug 19 20:26:31 2020 CEST
|
||||
Local Time is: Thu Oct 1 08:21:29 2020 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -27,8 +27,8 @@ Wt Cache Reorder: Enabled
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x84) Offline data collection activity
|
||||
was suspended by an interrupting command from host.
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
@@ -63,17 +63,17 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 192 173 021 - 5358
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 75
|
||||
3 Spin_Up_Time POS--K 185 173 021 - 5708
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 86
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 056 056 000 - 32129
|
||||
9 Power_On_Hours -O--CK 055 055 000 - 33142
|
||||
10 Spin_Retry_Count -O--CK 100 253 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 253 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 74
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 35
|
||||
193 Load_Cycle_Count -O--CK 009 009 000 - 573581
|
||||
194 Temperature_Celsius -O---K 113 102 000 - 37
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 85
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 43
|
||||
193 Load_Cycle_Count -O--CK 005 005 000 - 586302
|
||||
194 Temperature_Celsius -O---K 114 102 000 - 36
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
@@ -126,10 +126,9 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
SCT Support Level: 1
|
||||
Device State: Active (0)
|
||||
Current Temperature: 37 Celsius
|
||||
Power Cycle Min/Max Temperature: 35/46 Celsius
|
||||
Current Temperature: 36 Celsius
|
||||
Power Cycle Min/Max Temperature: 30/39 Celsius
|
||||
Lifetime Min/Max Temperature: 10/48 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
@@ -141,7 +140,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (33)
|
||||
Temperature History Size (Index): 478 (68)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -164,5 +163,7 @@ ID Size Value Description
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 957088 Vendor specific
|
||||
0x8000 4 224815 Vendor specific
|
||||
|
||||
|
||||
|
||||
|
@@ -1,5 +1,5 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [FreeBSD 12.1-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.0-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Western Digital Green
|
||||
@@ -12,8 +12,8 @@ Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5400 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sun May 31 13:46:26 2020 +04
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Tue Mar 9 08:51:42 2021 +04
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -21,7 +21,7 @@ APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
@@ -64,17 +64,17 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 213 180 021 - 6341
|
||||
4 Start_Stop_Count -O--CK 094 094 000 - 6471
|
||||
3 Spin_Up_Time POS--K 232 180 021 - 5383
|
||||
4 Start_Stop_Count -O--CK 094 094 000 - 6531
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 034 034 000 - 48581
|
||||
9 Power_On_Hours -O--CK 025 025 000 - 55155
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 636
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 358
|
||||
193 Load_Cycle_Count -O--CK 186 186 000 - 43194
|
||||
194 Temperature_Celsius -O---K 118 102 000 - 34
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 689
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 392
|
||||
193 Load_Cycle_Count -O--CK 186 186 000 - 44224
|
||||
194 Temperature_Celsius -O---K 116 102 000 - 36
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
@@ -130,8 +130,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 34 Celsius
|
||||
Power Cycle Min/Max Temperature: 34/35 Celsius
|
||||
Current Temperature: 36 Celsius
|
||||
Power Cycle Min/Max Temperature: 28/41 Celsius
|
||||
Lifetime Min/Max Temperature: 3/50 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
@@ -143,7 +143,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (133)
|
||||
Temperature History Size (Index): 478 (407)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -161,12 +161,12 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 97 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 97 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 73 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 73 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 58555 Vendor specific
|
||||
0x8000 4 6784268 Vendor specific
|
||||
|
||||
|
||||
|
||||
|
@@ -1,5 +1,5 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.2-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p2 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Western Digital Blue
|
||||
@@ -10,10 +10,10 @@ Firmware Version: 80.00A80
|
||||
User Capacity: 3,000,592,982,016 bytes [3.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5400 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Thu Oct 21 05:29:14 2021 EDT
|
||||
Local Time is: Sat Sep 17 12:09:02 2022 CST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -64,21 +64,21 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 225 176 021 - 5716
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 171
|
||||
3 Spin_Up_Time POS--K 177 169 021 - 8108
|
||||
4 Start_Stop_Count -O--CK 098 098 000 - 2145
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 568
|
||||
9 Power_On_Hours -O--CK 096 096 000 - 2964
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 152
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 49
|
||||
193 Load_Cycle_Count -O--CK 189 189 000 - 34631
|
||||
194 Temperature_Celsius -O---K 116 104 000 - 36
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 1586
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 616
|
||||
193 Load_Cycle_Count -O--CK 162 162 000 - 115030
|
||||
194 Temperature_Celsius -O---K 108 103 000 - 44
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 589
|
||||
200 Multi_Zone_Error_Rate ---R-- 200 200 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
@@ -129,9 +129,9 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 37 Celsius
|
||||
Power Cycle Min/Max Temperature: 37/37 Celsius
|
||||
Lifetime Min/Max Temperature: 3/48 Celsius
|
||||
Current Temperature: 44 Celsius
|
||||
Power Cycle Min/Max Temperature: 44/44 Celsius
|
||||
Lifetime Min/Max Temperature: 3/49 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
@@ -142,7 +142,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (351)
|
||||
Temperature History Size (Index): 478 (272)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -160,12 +160,12 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 4 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 5 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 2 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 870 Vendor specific
|
||||
0x8000 4 433 Vendor specific
|
||||
|
||||
|
||||
|
||||
|
Reference in New Issue