mirror of
https://github.com/bsdhw/SMART.git
synced 2025-05-31 16:21:41 +05:30
Update of reports (new: 0, modified: 1434)
This commit is contained in:
@@ -12,7 +12,7 @@ Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 2.5, 3.0 Gb/s
|
||||
Local Time is: Sun Aug 22 11:28:54 2021 BST
|
||||
Local Time is: Thu Aug 26 10:35:23 2021 BST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
@@ -64,16 +64,16 @@ Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 164 159 021 - 4791
|
||||
4 Start_Stop_Count -O--CK 098 098 000 - 2230
|
||||
4 Start_Stop_Count -O--CK 098 098 000 - 2236
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 100 253 000 - 0
|
||||
9 Power_On_Hours -O--CK 001 001 000 - 76400
|
||||
9 Power_On_Hours -O--CK 001 001 000 - 76434
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 2221
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 2227
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 276
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 2230
|
||||
194 Temperature_Celsius -O---K 104 102 000 - 43
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 2236
|
||||
194 Temperature_Celsius -O---K 112 102 000 - 35
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
@@ -131,9 +131,9 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 43 Celsius
|
||||
Power Cycle Min/Max Temperature: 22/44 Celsius
|
||||
Lifetime Min/Max Temperature: ?/45 Celsius
|
||||
Current Temperature: 35 Celsius
|
||||
Power Cycle Min/Max Temperature: 34/35 Celsius
|
||||
Lifetime Min/Max Temperature: 21/45 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
@@ -141,7 +141,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 128 (72)
|
||||
Temperature History Size (Index): 128 (73)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -159,5 +159,5 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
|
||||
0x8000 4 11729 Vendor specific
|
||||
0x8000 4 1907 Vendor specific
|
||||
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p16-HBSD amd64] (local build)
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p20-HBSD amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -11,7 +11,7 @@ User Capacity: 500,106,780,160 bytes [500 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA/ATAPI-7 (minor revision not indicated)
|
||||
Local Time is: Wed Aug 11 20:39:36 2021 MDT
|
||||
Local Time is: Mon Nov 8 18:19:44 2021 CST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM level is: 254 (maximum performance), recommended: 128
|
||||
@@ -63,17 +63,17 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 200 200 051 - 0
|
||||
3 Spin_Up_Time PO---- 175 168 021 - 6208
|
||||
4 Start_Stop_Count -O--CK 086 086 000 - 14826
|
||||
3 Spin_Up_Time PO---- 172 168 021 - 6400
|
||||
4 Start_Stop_Count -O--CK 086 086 000 - 14832
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-- 200 200 051 - 0
|
||||
9 Power_On_Hours -O--CK 048 048 000 - 38668
|
||||
9 Power_On_Hours -O--CK 045 045 000 - 40795
|
||||
10 Spin_Retry_Count -O--C- 100 100 051 - 0
|
||||
11 Calibration_Retry_Count -O--C- 100 100 051 - 0
|
||||
12 Power_Cycle_Count -O--CK 097 097 000 - 3725
|
||||
12 Power_Cycle_Count -O--CK 097 097 000 - 3731
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 112
|
||||
193 Load_Cycle_Count -O--CK 196 196 000 - 14827
|
||||
194 Temperature_Celsius -O---K 113 084 000 - 37
|
||||
193 Load_Cycle_Count -O--CK 196 196 000 - 14833
|
||||
194 Temperature_Celsius -O---K 114 084 000 - 36
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--C- 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 200 200 000 - 0
|
||||
@@ -126,8 +126,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 37 Celsius
|
||||
Power Cycle Min/Max Temperature: --/41 Celsius
|
||||
Current Temperature: 36 Celsius
|
||||
Power Cycle Min/Max Temperature: --/38 Celsius
|
||||
Lifetime Min/Max Temperature: --/66 Celsius
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
@@ -135,7 +135,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -40/85 Celsius
|
||||
Temperature History Size (Index): 128 (8)
|
||||
Temperature History Size (Index): 128 (79)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -154,6 +154,6 @@ ID Size Value Description
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000a 2 6 Device-to-host register FISes sent due to a COMRESET
|
||||
0x8000 4 3458057 Vendor specific
|
||||
0x000a 2 346 Device-to-host register FISes sent due to a COMRESET
|
||||
0x8000 4 123785 Vendor specific
|
||||
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p18-HBSD amd64] (local build)
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p19-HBSD amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -12,7 +12,7 @@ Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s
|
||||
Local Time is: Mon Jul 19 11:48:24 2021 CDT
|
||||
Local Time is: Wed Aug 18 17:11:40 2021 CDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
@@ -64,16 +64,16 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 81
|
||||
3 Spin_Up_Time POS--K 141 139 021 - 3916
|
||||
4 Start_Stop_Count -O--CK 098 098 000 - 2804
|
||||
3 Spin_Up_Time POS--K 141 139 021 - 3933
|
||||
4 Start_Stop_Count -O--CK 098 098 000 - 2805
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 063 063 000 - 27336
|
||||
9 Power_On_Hours -O--CK 062 062 000 - 28061
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 1723
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 1724
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 254
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 2549
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 2550
|
||||
194 Temperature_Celsius -O---K 102 092 000 - 41
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
@@ -178,7 +178,7 @@ SCT Status Version: 2
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 41 Celsius
|
||||
Power Cycle Min/Max Temperature: 28/42 Celsius
|
||||
Power Cycle Min/Max Temperature: 41/41 Celsius
|
||||
Lifetime Min/Max Temperature: 24/51 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
@@ -187,7 +187,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (163)
|
||||
Temperature History Size (Index): 478 (142)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -206,7 +206,7 @@ ID Size Value Description
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000a 2 14 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000a 2 8 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x8000 4 8949441 Vendor specific
|
||||
0x8000 4 325701 Vendor specific
|
||||
|
||||
|
@@ -12,7 +12,7 @@ Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Wed Mar 31 08:57:17 2021 CDT
|
||||
Local Time is: Sun Apr 4 20:08:11 2021 CDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -64,16 +64,16 @@ Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 4
|
||||
3 Spin_Up_Time POS--K 141 140 021 - 3950
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 442
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 443
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 012 012 000 - 64327
|
||||
9 Power_On_Hours -O--CK 012 012 000 - 64434
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 440
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 441
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 213
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 228
|
||||
194 Temperature_Celsius -O---K 094 091 000 - 49
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 229
|
||||
194 Temperature_Celsius -O---K 088 088 000 - 55
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
@@ -196,24 +196,24 @@ Error 1 [0] occurred at disk power-on lifetime: 59005 hours (2458 days + 13 hour
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Extended offline Completed without error 00% 10478 -
|
||||
# 2 Extended offline Completed without error 00% 10313 -
|
||||
# 3 Extended offline Completed without error 00% 10145 -
|
||||
# 4 Extended offline Completed without error 00% 9978 -
|
||||
# 5 Extended offline Completed without error 00% 9810 -
|
||||
# 6 Extended offline Completed without error 00% 9643 -
|
||||
# 7 Extended offline Completed without error 00% 9475 -
|
||||
# 8 Extended offline Completed without error 00% 9308 -
|
||||
# 9 Extended offline Completed without error 00% 9146 -
|
||||
#10 Extended offline Completed without error 00% 8979 -
|
||||
#11 Extended offline Completed without error 00% 8812 -
|
||||
#12 Extended offline Completed without error 00% 8645 -
|
||||
#13 Extended offline Completed without error 00% 8484 -
|
||||
#14 Extended offline Completed without error 00% 8316 -
|
||||
#15 Extended offline Completed without error 00% 8148 -
|
||||
#16 Extended offline Completed without error 00% 7981 -
|
||||
#17 Extended offline Completed without error 00% 7814 -
|
||||
#18 Extended offline Completed without error 00% 7646 -
|
||||
# 1 Short offline Completed without error 00% 64327 -
|
||||
# 2 Extended offline Completed without error 00% 10478 -
|
||||
# 3 Extended offline Completed without error 00% 10313 -
|
||||
# 4 Extended offline Completed without error 00% 10145 -
|
||||
# 5 Extended offline Completed without error 00% 9978 -
|
||||
# 6 Extended offline Completed without error 00% 9810 -
|
||||
# 7 Extended offline Completed without error 00% 9643 -
|
||||
# 8 Extended offline Completed without error 00% 9475 -
|
||||
# 9 Extended offline Completed without error 00% 9308 -
|
||||
#10 Extended offline Completed without error 00% 9146 -
|
||||
#11 Extended offline Completed without error 00% 8979 -
|
||||
#12 Extended offline Completed without error 00% 8812 -
|
||||
#13 Extended offline Completed without error 00% 8645 -
|
||||
#14 Extended offline Completed without error 00% 8484 -
|
||||
#15 Extended offline Completed without error 00% 8316 -
|
||||
#16 Extended offline Completed without error 00% 8148 -
|
||||
#17 Extended offline Completed without error 00% 7981 -
|
||||
#18 Extended offline Completed without error 00% 7814 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
@@ -229,9 +229,9 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 49 Celsius
|
||||
Power Cycle Min/Max Temperature: 41/50 Celsius
|
||||
Lifetime Min/Max Temperature: 0/52 Celsius
|
||||
Current Temperature: 55 Celsius
|
||||
Power Cycle Min/Max Temperature: 51/55 Celsius
|
||||
Lifetime Min/Max Temperature: 0/55 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
@@ -239,7 +239,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (165)
|
||||
Temperature History Size (Index): 478 (320)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -256,7 +256,7 @@ ID Size Value Description
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000a 2 6 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x8000 4 58275 Vendor specific
|
||||
0x8000 4 21634 Vendor specific
|
||||
|
||||
|
@@ -13,7 +13,7 @@ Rotation Rate: 7200 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Thu Feb 10 01:04:56 2022 PST
|
||||
Local Time is: Thu Feb 10 03:15:47 2022 PST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,24 +65,24 @@ Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 141 140 021 - 3908
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 87
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 88
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 097 097 000 - 2697
|
||||
9 Power_On_Hours -O--CK 097 097 000 - 2700
|
||||
10 Spin_Retry_Count -O--CK 100 253 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 253 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 87
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 88
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 39
|
||||
193 Load_Cycle_Count -O--CK 176 176 000 - 74544
|
||||
194 Temperature_Celsius -O---K 116 104 000 - 27
|
||||
193 Load_Cycle_Count -O--CK 176 176 000 - 74572
|
||||
194 Temperature_Celsius -O---K 114 104 000 - 29
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate ---R-- 200 200 000 - 0
|
||||
240 Head_Flying_Hours -O--CK 098 098 000 - 2058
|
||||
241 Total_LBAs_Written -O--CK 200 200 000 - 63570358798
|
||||
242 Total_LBAs_Read -O--CK 200 200 000 - 3370795702
|
||||
240 Head_Flying_Hours -O--CK 098 098 000 - 2060
|
||||
241 Total_LBAs_Written -O--CK 200 200 000 - 63575023590
|
||||
242 Total_LBAs_Read -O--CK 200 200 000 - 3372029569
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -133,8 +133,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 27 Celsius
|
||||
Power Cycle Min/Max Temperature: 23/30 Celsius
|
||||
Current Temperature: 29 Celsius
|
||||
Power Cycle Min/Max Temperature: 27/29 Celsius
|
||||
Lifetime Min/Max Temperature: 0/39 Celsius
|
||||
Specified Max Operating Temperature: 27 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
@@ -144,7 +144,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (177)
|
||||
Temperature History Size (Index): 478 (306)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -161,7 +161,7 @@ ID Size Value Description
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000a 2 6 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x8000 4 458458 Vendor specific
|
||||
0x8000 4 6768 Vendor specific
|
||||
|
||||
|
@@ -14,7 +14,7 @@ Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Wed Feb 9 14:02:30 2022 IST
|
||||
Local Time is: Fri Feb 18 17:01:39 2022 IST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -63,22 +63,22 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 177 173 021 - 2150
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 92
|
||||
3 Spin_Up_Time POS--K 177 173 021 - 2141
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 93
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate POSR-K 200 200 051 - 0
|
||||
9 Power_On_Hours -O--CK 080 080 000 - 14645
|
||||
9 Power_On_Hours -O--CK 080 080 000 - 14863
|
||||
10 Spin_Retry_Count PO--CK 100 253 051 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 253 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 92
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 93
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error PO--CK 100 100 097 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 062 055 040 - 38 (Min/Max 23/38)
|
||||
190 Airflow_Temperature_Cel -O---K 060 055 040 - 40 (Min/Max 34/40)
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 31
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 96
|
||||
194 Temperature_Celsius -O---K 106 098 000 - 37
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 317
|
||||
194 Temperature_Celsius -O---K 103 098 000 - 40
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
@@ -110,7 +110,7 @@ Address Access R/W Size Description
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
|
||||
0xa8-0xb5 GPL,SL VS 1 Device vendor specific log
|
||||
0xb6 GPL VS 1832 Device vendor specific log
|
||||
0xb6 GPL VS 1859 Device vendor specific log
|
||||
0xb6 SL VS 1 Device vendor specific log
|
||||
0xb7 GPL,SL VS 48 Device vendor specific log
|
||||
0xbd GPL,SL VS 1 Device vendor specific log
|
||||
@@ -120,7 +120,7 @@ Address Access R/W Size Description
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
|
||||
Device Error Count: 132 (device log contains only the most recent 24 errors)
|
||||
Device Error Count: 135 (device log contains only the most recent 24 errors)
|
||||
CR = Command Register
|
||||
FEATR = Features Register
|
||||
COUNT = Count (was: Sector Count) Register
|
||||
@@ -136,6 +136,57 @@ Powered_Up_Time is measured from power on, and printed as
|
||||
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
||||
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
||||
|
||||
Error 135 [14] occurred at disk power-on lifetime: 14863 hours (619 days + 7 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
04 -- 51 00 00 00 00 00 00 00 02 e0 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
b4 00 20 00 00 00 00 46 72 4c 6b e0 00 9d+02:00:30.088 SANITIZE DEVICE
|
||||
f5 00 00 00 00 00 00 00 00 00 00 e0 00 9d+02:00:30.088 SECURITY FREEZE LOCK
|
||||
25 00 00 00 01 00 00 00 00 00 21 e0 00 9d+02:00:29.780 READ DMA EXT
|
||||
25 00 00 00 01 00 00 00 00 00 20 e0 00 9d+02:00:29.780 READ DMA EXT
|
||||
25 00 00 00 01 00 00 00 00 00 1f e0 00 9d+02:00:29.779 READ DMA EXT
|
||||
|
||||
Error 134 [13] occurred at disk power-on lifetime: 14650 hours (610 days + 10 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
04 -- 51 00 00 00 00 00 00 00 02 e0 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
b4 00 20 00 00 00 00 46 72 4c 6b e0 00 04:32:54.650 SANITIZE DEVICE
|
||||
f5 00 00 00 00 00 00 00 00 00 00 e0 00 04:32:54.649 SECURITY FREEZE LOCK
|
||||
25 00 00 00 01 00 00 00 00 00 21 e0 00 04:32:54.341 READ DMA EXT
|
||||
25 00 00 00 01 00 00 00 00 00 20 e0 00 04:32:54.340 READ DMA EXT
|
||||
25 00 00 00 01 00 00 00 00 00 1f e0 00 04:32:54.340 READ DMA EXT
|
||||
|
||||
Error 133 [12] occurred at disk power-on lifetime: 14645 hours (610 days + 5 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
04 -- 51 00 00 00 00 00 00 00 02 e0 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
b4 00 20 00 00 00 00 46 72 4c 6b e0 00 00:00:02.728 SANITIZE DEVICE
|
||||
f5 00 00 00 00 00 00 00 00 00 00 e0 00 00:00:02.728 SECURITY FREEZE LOCK
|
||||
ec 00 00 00 00 00 00 00 00 00 00 e0 00 00:00:02.667 IDENTIFY DEVICE
|
||||
25 00 00 00 01 00 00 00 00 00 21 e0 00 00:00:02.374 READ DMA EXT
|
||||
25 00 00 00 01 00 00 00 00 00 20 e0 00 00:00:02.374 READ DMA EXT
|
||||
|
||||
Error 132 [11] occurred at disk power-on lifetime: 14643 hours (610 days + 3 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
@@ -221,57 +272,6 @@ Error 128 [7] occurred at disk power-on lifetime: 14642 hours (610 days + 2 hour
|
||||
25 00 00 00 01 00 00 00 00 00 21 e0 00 00:00:02.374 READ DMA EXT
|
||||
25 00 00 00 01 00 00 00 00 00 20 e0 00 00:00:02.374 READ DMA EXT
|
||||
|
||||
Error 127 [6] occurred at disk power-on lifetime: 14622 hours (609 days + 6 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
04 -- 51 00 00 00 00 00 00 00 02 e0 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
b4 00 20 00 00 00 00 46 72 4c 6b e0 00 00:00:03.023 SANITIZE DEVICE
|
||||
f5 00 00 00 00 00 00 00 00 00 00 e0 00 00:00:03.023 SECURITY FREEZE LOCK
|
||||
ec 00 00 00 00 00 00 00 00 00 00 e0 00 00:00:02.958 IDENTIFY DEVICE
|
||||
25 00 00 00 01 00 00 00 00 00 21 e0 00 00:00:02.665 READ DMA EXT
|
||||
25 00 00 00 01 00 00 00 00 00 20 e0 00 00:00:02.665 READ DMA EXT
|
||||
|
||||
Error 126 [5] occurred at disk power-on lifetime: 14620 hours (609 days + 4 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
04 -- 51 00 00 00 00 00 00 00 02 e0 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
b4 00 20 00 00 00 00 46 72 4c 6b e0 00 00:12:03.802 SANITIZE DEVICE
|
||||
f5 00 00 00 00 00 00 00 00 00 00 e0 00 00:12:03.801 SECURITY FREEZE LOCK
|
||||
25 00 00 00 01 00 00 00 00 00 21 e0 00 00:12:03.491 READ DMA EXT
|
||||
25 00 00 00 01 00 00 00 00 00 20 e0 00 00:12:03.490 READ DMA EXT
|
||||
25 00 00 00 01 00 00 00 00 00 1f e0 00 00:12:03.490 READ DMA EXT
|
||||
|
||||
Error 125 [4] occurred at disk power-on lifetime: 14620 hours (609 days + 4 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
04 -- 51 00 00 00 00 00 00 00 02 e0 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
b4 00 20 00 00 00 00 46 72 4c 6b e0 00 00:04:02.768 SANITIZE DEVICE
|
||||
f5 00 00 00 00 00 00 00 00 00 00 e0 00 00:04:02.768 SECURITY FREEZE LOCK
|
||||
25 00 00 00 01 00 00 00 00 00 21 e0 00 00:04:02.458 READ DMA EXT
|
||||
25 00 00 00 01 00 00 00 00 00 20 e0 00 00:04:02.458 READ DMA EXT
|
||||
25 00 00 00 01 00 00 00 00 00 1f e0 00 00:04:02.458 READ DMA EXT
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Aborted by host 90% 14617 -
|
||||
@@ -291,8 +291,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 37 Celsius
|
||||
Power Cycle Min/Max Temperature: 23/38 Celsius
|
||||
Current Temperature: 40 Celsius
|
||||
Power Cycle Min/Max Temperature: 34/41 Celsius
|
||||
Lifetime Min/Max Temperature: 20/45 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
@@ -304,7 +304,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 128 (33)
|
||||
Temperature History Size (Index): 128 (81)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 85 (8.5 seconds)
|
||||
@@ -313,17 +313,17 @@ SCT Error Recovery Control:
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 92 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 14645 --- Power-on Hours
|
||||
0x01 0x018 6 21752763596 --- Logical Sectors Written
|
||||
0x01 0x008 4 93 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 14863 --- Power-on Hours
|
||||
0x01 0x018 6 21752763600 --- Logical Sectors Written
|
||||
0x01 0x020 6 601074140 --- Number of Write Commands
|
||||
0x01 0x028 6 41879941519 --- Logical Sectors Read
|
||||
0x01 0x030 6 394131490 --- Number of Read Commands
|
||||
0x01 0x038 6 1182392448 --- Date and Time TimeStamp
|
||||
0x01 0x028 6 41879943165 --- Logical Sectors Read
|
||||
0x01 0x030 6 394131962 --- Number of Read Commands
|
||||
0x01 0x038 6 1967192448 --- Date and Time TimeStamp
|
||||
0x03 ===== = = === == Rotating Media Statistics (rev 1) ==
|
||||
0x03 0x008 4 13907 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 13881 --- Head Flying Hours
|
||||
0x03 0x018 4 128 --- Head Load Events
|
||||
0x03 0x008 4 14125 --- Spindle Motor Power-on Hours
|
||||
0x03 0x010 4 13900 --- Head Flying Hours
|
||||
0x03 0x018 4 349 --- Head Load Events
|
||||
0x03 0x020 4 0 --- Number of Reallocated Logical Sectors
|
||||
0x03 0x028 4 0 --- Read Recovery Attempts
|
||||
0x03 0x030 4 0 --- Number of Mechanical Start Failures
|
||||
@@ -333,9 +333,9 @@ Page Offset Size Value Flags Description
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 37 --- Current Temperature
|
||||
0x05 0x010 1 32 --- Average Short Term Temperature
|
||||
0x05 0x018 1 36 --- Average Long Term Temperature
|
||||
0x05 0x008 1 40 --- Current Temperature
|
||||
0x05 0x010 1 39 --- Average Short Term Temperature
|
||||
0x05 0x018 1 37 --- Average Long Term Temperature
|
||||
0x05 0x020 1 45 --- Highest Temperature
|
||||
0x05 0x028 1 25 --- Lowest Temperature
|
||||
0x05 0x030 1 42 --- Highest Average Short Term Temperature
|
||||
@@ -347,8 +347,8 @@ Page Offset Size Value Flags Description
|
||||
0x05 0x060 4 0 --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 347 --- Number of Hardware Resets
|
||||
0x06 0x010 4 222 --- Number of ASR Events
|
||||
0x06 0x008 4 358 --- Number of Hardware Resets
|
||||
0x06 0x010 4 229 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
@@ -366,13 +366,13 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 18 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 19 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 10 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 11 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 7858 Vendor specific
|
||||
0x8000 4 785219 Vendor specific
|
||||
|
||||
|
||||
|
||||
|
@@ -13,7 +13,7 @@ Rotation Rate: 7200 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s
|
||||
Local Time is: Thu Dec 30 16:25:41 2021 AEDT
|
||||
Local Time is: Wed Jan 26 12:33:32 2022 AEDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -68,13 +68,13 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
4 Start_Stop_Count -O--CK 098 098 000 - 2102
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 034 034 000 - 48605
|
||||
9 Power_On_Hours -O--CK 033 033 000 - 49249
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 168
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 25
|
||||
193 Load_Cycle_Count -O--CK 001 001 000 - 1545185
|
||||
194 Temperature_Celsius -O---K 118 100 000 - 29
|
||||
193 Load_Cycle_Count -O--CK 001 001 000 - 1600787
|
||||
194 Temperature_Celsius -O---K 116 100 000 - 31
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 253 000 - 0
|
||||
@@ -146,7 +146,7 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 29 Celsius
|
||||
Current Temperature: 31 Celsius
|
||||
Power Cycle Min/Max Temperature: 27/35 Celsius
|
||||
Lifetime Min/Max Temperature: 27/47 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
@@ -159,7 +159,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 128 (17)
|
||||
Temperature History Size (Index): 128 (98)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -178,7 +178,7 @@ ID Size Value Description
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x8000 4 164385 Vendor specific
|
||||
0x8000 4 2480960 Vendor specific
|
||||
|
||||
|
||||
|
||||
|
@@ -13,7 +13,7 @@ Rotation Rate: 7200 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s
|
||||
Local Time is: Thu Dec 30 16:25:41 2021 AEDT
|
||||
Local Time is: Wed Jan 26 12:33:32 2022 AEDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -68,13 +68,13 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
4 Start_Stop_Count -O--CK 098 098 000 - 2149
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 034 034 000 - 48221
|
||||
9 Power_On_Hours -O--CK 034 034 000 - 48865
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 176
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 37
|
||||
193 Load_Cycle_Count -O--CK 001 001 000 - 1456494
|
||||
194 Temperature_Celsius -O---K 118 100 000 - 29
|
||||
193 Load_Cycle_Count -O--CK 001 001 000 - 1508717
|
||||
194 Temperature_Celsius -O---K 116 100 000 - 31
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 253 000 - 0
|
||||
@@ -146,9 +146,9 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 30 Celsius
|
||||
Power Cycle Min/Max Temperature: 28/35 Celsius
|
||||
Lifetime Min/Max Temperature: 28/47 Celsius
|
||||
Current Temperature: 32 Celsius
|
||||
Power Cycle Min/Max Temperature: 27/35 Celsius
|
||||
Lifetime Min/Max Temperature: 27/47 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
@@ -159,7 +159,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 128 (85)
|
||||
Temperature History Size (Index): 128 (37)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -178,7 +178,7 @@ ID Size Value Description
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000a 2 10 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x8000 4 164382 Vendor specific
|
||||
0x8000 4 2480917 Vendor specific
|
||||
|
||||
|
||||
|
||||
|
@@ -13,7 +13,7 @@ Rotation Rate: 5400 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Sat May 9 06:24:52 2020 CET
|
||||
Local Time is: Thu May 21 13:12:29 2020 MSK
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -64,17 +64,17 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 176 174 021 - 2175
|
||||
4 Start_Stop_Count -O--CK 097 097 000 - 3190
|
||||
3 Spin_Up_Time POS--K 177 174 021 - 2108
|
||||
4 Start_Stop_Count -O--CK 097 097 000 - 3201
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 086 086 000 - 10314
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 2607
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 131
|
||||
193 Load_Cycle_Count -O--CK 180 180 000 - 62472
|
||||
194 Temperature_Celsius -O---K 115 096 000 - 32
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 2618
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 137
|
||||
193 Load_Cycle_Count -O--CK 180 180 000 - 62491
|
||||
194 Temperature_Celsius -O---K 122 096 000 - 25
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
@@ -130,8 +130,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 32 Celsius
|
||||
Power Cycle Min/Max Temperature: 31/32 Celsius
|
||||
Current Temperature: 25 Celsius
|
||||
Power Cycle Min/Max Temperature: 24/25 Celsius
|
||||
Lifetime Min/Max Temperature: 13/52 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
@@ -143,7 +143,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 128 (8)
|
||||
Temperature History Size (Index): 128 (63)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -161,12 +161,10 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 11 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 7 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 5 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 415 Vendor specific
|
||||
|
||||
|
||||
0x8000 4 249 Vendor specific
|
||||
|
||||
|
@@ -1,5 +1,5 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.2-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p2 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Western Digital Blue Mobile
|
||||
@@ -11,10 +11,10 @@ User Capacity: 500,107,862,016 bytes [500 GB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5400 rpm
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Thu Oct 21 05:29:14 2021 EDT
|
||||
Local Time is: Sat Sep 17 12:09:03 2022 CST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -29,8 +29,8 @@ Wt Cache Reorder: Enabled
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x80) Offline data collection activity
|
||||
was never started.
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
@@ -65,22 +65,22 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 152 148 021 - 1391
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 147
|
||||
3 Spin_Up_Time POS--K 148 143 021 - 1566
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 566
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 568
|
||||
9 Power_On_Hours -O--CK 099 099 000 - 1366
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 144
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 41
|
||||
193 Load_Cycle_Count -O--CK 199 199 000 - 5352
|
||||
194 Temperature_Celsius -O---K 111 095 000 - 32
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 518
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 85
|
||||
193 Load_Cycle_Count -O--CK 198 198 000 - 7293
|
||||
194 Temperature_Celsius -O---K 102 095 000 - 41
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 253 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate ---R-- 100 253 000 - 0
|
||||
200 Multi_Zone_Error_Rate ---R-- 200 200 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -131,9 +131,9 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 32 Celsius
|
||||
Power Cycle Min/Max Temperature: 32/34 Celsius
|
||||
Lifetime Min/Max Temperature: 26/48 Celsius
|
||||
Current Temperature: 41 Celsius
|
||||
Power Cycle Min/Max Temperature: 41/41 Celsius
|
||||
Lifetime Min/Max Temperature: 17/48 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
@@ -144,7 +144,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 128 (34)
|
||||
Temperature History Size (Index): 128 (57)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -162,12 +162,12 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 4 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 5 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 2 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 874 Vendor specific
|
||||
0x8000 4 442 Vendor specific
|
||||
|
||||
|
||||
|
||||
|
@@ -14,7 +14,7 @@ Form Factor: 2.5 inches
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-3 T13/2161-D revision 5
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Sat Sep 10 11:19:29 2022 EDT
|
||||
Local Time is: Sat Sep 10 13:50:33 2022 EDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -64,23 +64,23 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 188 051 - 0
|
||||
3 Spin_Up_Time POS--K 148 144 021 - 1583
|
||||
4 Start_Stop_Count -O--CK 067 067 000 - 33848
|
||||
3 Spin_Up_Time POS--K 150 144 021 - 1483
|
||||
4 Start_Stop_Count -O--CK 067 067 000 - 33855
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate POSR-K 200 200 051 - 0
|
||||
9 Power_On_Hours -O--CK 088 088 000 - 9148
|
||||
10 Spin_Retry_Count PO--CK 100 100 051 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 096 096 000 - 4235
|
||||
12 Power_Cycle_Count -O--CK 096 096 000 - 4242
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error PO--CK 100 100 097 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 001 000 - 882
|
||||
188 Command_Timeout -O--CK 100 001 000 - 4295492134
|
||||
190 Airflow_Temperature_Cel -O---K 076 053 040 - 24 (Min/Max 22/24)
|
||||
190 Airflow_Temperature_Cel -O---K 073 053 040 - 27 (Min/Max 27/27)
|
||||
191 G-Sense_Error_Rate -O--CK 001 001 000 - 667
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 142
|
||||
193 Load_Cycle_Count -O--CK 183 183 000 - 51403
|
||||
194 Temperature_Celsius -O---K 119 096 000 - 24
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 144
|
||||
193 Load_Cycle_Count -O--CK 183 183 000 - 51424
|
||||
194 Temperature_Celsius -O---K 116 096 000 - 27
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 253 000 - 0
|
||||
@@ -289,8 +289,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 24 Celsius
|
||||
Power Cycle Min/Max Temperature: 22/24 Celsius
|
||||
Current Temperature: 27 Celsius
|
||||
Power Cycle Min/Max Temperature: 27/27 Celsius
|
||||
Lifetime Min/Max Temperature: 9/48 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
@@ -302,7 +302,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 128 (87)
|
||||
Temperature History Size (Index): 128 (10)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 85 (8.5 seconds)
|
||||
@@ -323,9 +323,9 @@ ID Size Value Description
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 4 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000a 2 4 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 615 Vendor specific
|
||||
0x8000 4 270 Vendor specific
|
||||
|
||||
|
@@ -1,5 +1,5 @@
|
||||
smartctl 7.1 2019-12-30 r5022 [x86_64-unknown-openbsd6.9] (local build)
|
||||
Copyright (C) 2002-19, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
smartctl 7.2 2020-12-30 r5155 [OpenBSD 7.0 amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Western Digital Black Mobile
|
||||
@@ -13,7 +13,7 @@ Rotation Rate: 7200 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2, ACS-3 T13/2161-D revision 3b
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Mon May 17 13:27:14 2021 EDT
|
||||
Local Time is: Thu Oct 21 22:02:54 2021 EDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
|
||||
@@ -59,16 +59,16 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
|
||||
1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always - 0
|
||||
3 Spin_Up_Time 0x0027 144 143 021 Pre-fail Always - 1766
|
||||
4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 333
|
||||
3 Spin_Up_Time 0x0027 144 143 021 Pre-fail Always - 1775
|
||||
4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 355
|
||||
5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0
|
||||
7 Seek_Error_Rate 0x002e 200 200 000 Old_age Always - 0
|
||||
9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 678
|
||||
9 Power_On_Hours 0x0032 099 099 000 Old_age Always - 754
|
||||
10 Spin_Retry_Count 0x0032 100 100 000 Old_age Always - 0
|
||||
11 Calibration_Retry_Count 0x0032 100 100 000 Old_age Always - 0
|
||||
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 333
|
||||
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 355
|
||||
192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 5
|
||||
193 Load_Cycle_Count 0x0032 196 196 000 Old_age Always - 13303
|
||||
193 Load_Cycle_Count 0x0032 196 196 000 Old_age Always - 14279
|
||||
194 Temperature_Celsius 0x0022 103 095 000 Old_age Always - 40
|
||||
196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
|
||||
197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 0
|
||||
@@ -81,27 +81,27 @@ No Errors Logged
|
||||
|
||||
SMART Self-test log structure revision number 1
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Extended offline Interrupted (host reset) 50% 669 -
|
||||
# 2 Extended offline Interrupted (host reset) 50% 658 -
|
||||
# 3 Extended offline Interrupted (host reset) 80% 640 -
|
||||
# 4 Extended offline Interrupted (host reset) 90% 631 -
|
||||
# 5 Extended offline Interrupted (host reset) 60% 607 -
|
||||
# 6 Extended offline Interrupted (host reset) 90% 596 -
|
||||
# 7 Extended offline Interrupted (host reset) 10% 582 -
|
||||
# 8 Short offline Completed without error 00% 542 -
|
||||
# 9 Extended offline Interrupted (host reset) 10% 532 -
|
||||
#10 Short offline Completed without error 00% 524 -
|
||||
#11 Short offline Completed without error 00% 513 -
|
||||
#12 Short offline Aborted by host 10% 510 -
|
||||
#13 Extended offline Interrupted (host reset) 80% 508 -
|
||||
#14 Extended offline Interrupted (host reset) 90% 489 -
|
||||
#15 Extended offline Interrupted (host reset) 70% 485 -
|
||||
#16 Short offline Completed without error 00% 481 -
|
||||
#17 Short offline Completed without error 00% 473 -
|
||||
#18 Short offline Completed without error 00% 471 -
|
||||
#19 Short offline Completed without error 00% 467 -
|
||||
#20 Extended offline Interrupted (host reset) 60% 464 -
|
||||
#21 Short offline Aborted by host 70% 460 -
|
||||
# 1 Extended offline Interrupted (host reset) 10% 742 -
|
||||
# 2 Short offline Completed without error 00% 691 -
|
||||
# 3 Extended offline Interrupted (host reset) 90% 680 -
|
||||
# 4 Extended offline Interrupted (host reset) 50% 669 -
|
||||
# 5 Extended offline Interrupted (host reset) 50% 658 -
|
||||
# 6 Extended offline Interrupted (host reset) 80% 640 -
|
||||
# 7 Extended offline Interrupted (host reset) 90% 631 -
|
||||
# 8 Extended offline Interrupted (host reset) 60% 607 -
|
||||
# 9 Extended offline Interrupted (host reset) 90% 596 -
|
||||
#10 Extended offline Interrupted (host reset) 10% 582 -
|
||||
#11 Short offline Completed without error 00% 542 -
|
||||
#12 Extended offline Interrupted (host reset) 10% 532 -
|
||||
#13 Short offline Completed without error 00% 524 -
|
||||
#14 Short offline Completed without error 00% 513 -
|
||||
#15 Short offline Aborted by host 10% 510 -
|
||||
#16 Extended offline Interrupted (host reset) 80% 508 -
|
||||
#17 Extended offline Interrupted (host reset) 90% 489 -
|
||||
#18 Extended offline Interrupted (host reset) 70% 485 -
|
||||
#19 Short offline Completed without error 00% 481 -
|
||||
#20 Short offline Completed without error 00% 473 -
|
||||
#21 Short offline Completed without error 00% 471 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
|
@@ -12,7 +12,7 @@ Rotation Rate: 5400 rpm
|
||||
Device is: Not in smartctl database [for details use: -P showall]
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 3.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Wed Sep 15 11:56:26 2021 CEST
|
||||
Local Time is: Fri Sep 17 12:41:12 2021 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -63,18 +63,18 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 152 146 021 - 1391
|
||||
4 Start_Stop_Count -O--CK 098 098 000 - 2859
|
||||
3 Spin_Up_Time POS--K 151 146 021 - 1408
|
||||
4 Start_Stop_Count -O--CK 098 098 000 - 2860
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 088 088 000 - 8817
|
||||
9 Power_On_Hours -O--CK 088 088 000 - 8862
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 2852
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 2853
|
||||
191 G-Sense_Error_Rate -O--CK 073 073 000 - 27
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 47
|
||||
193 Load_Cycle_Count -O--CK 082 082 000 - 354126
|
||||
194 Temperature_Celsius -O---K 105 096 000 - 38
|
||||
193 Load_Cycle_Count -O--CK 082 082 000 - 354137
|
||||
194 Temperature_Celsius -O---K 098 096 000 - 45
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 253 000 - 0
|
||||
@@ -128,8 +128,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 38 Celsius
|
||||
Power Cycle Min/Max Temperature: 27/40 Celsius
|
||||
Current Temperature: 45 Celsius
|
||||
Power Cycle Min/Max Temperature: 27/45 Celsius
|
||||
Lifetime Min/Max Temperature: 22/47 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
@@ -141,7 +141,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 128 (95)
|
||||
Temperature History Size (Index): 128 (11)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -159,10 +159,10 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 14 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x0009 2 8 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 4 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 1722222 Vendor specific
|
||||
0x8000 4 85431 Vendor specific
|
||||
|
||||
|
@@ -1,4 +1,4 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p12-HBSD amd64] (local build)
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p15-HBSD amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -13,7 +13,7 @@ Rotation Rate: 5400 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Sat Jan 23 15:18:06 2021 GMT
|
||||
Local Time is: Wed Apr 7 20:04:56 2021 BST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -64,18 +64,18 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 154 148 021 - 1283
|
||||
4 Start_Stop_Count -O--CK 001 001 000 - 120460
|
||||
3 Spin_Up_Time POS--K 156 148 021 - 1175
|
||||
4 Start_Stop_Count -O--CK 001 001 000 - 139857
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 079 078 000 - 15873
|
||||
9 Power_On_Hours -O--CK 076 076 000 - 17651
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 253 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 35
|
||||
191 G-Sense_Error_Rate -O--CK 092 092 000 - 8
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 18
|
||||
193 Load_Cycle_Count -O--CK 001 001 000 - 3306954
|
||||
194 Temperature_Celsius -O---K 101 085 000 - 42
|
||||
193 Load_Cycle_Count -O--CK 001 001 000 - 3544363
|
||||
194 Temperature_Celsius -O---K 100 085 000 - 43
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 253 000 - 0
|
||||
@@ -130,7 +130,7 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 42 Celsius
|
||||
Current Temperature: 43 Celsius
|
||||
Power Cycle Min/Max Temperature: 36/52 Celsius
|
||||
Lifetime Min/Max Temperature: 0/58 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
@@ -143,7 +143,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 128 (84)
|
||||
Temperature History Size (Index): 128 (119)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -161,10 +161,10 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 29 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 30 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 50 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 51 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 15673458 Vendor specific
|
||||
0x8000 4 22074247 Vendor specific
|
||||
|
||||
|
@@ -13,7 +13,7 @@ Rotation Rate: 5400 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat Jan 23 18:39:04 2021 CET
|
||||
Local Time is: Tue Jan 26 18:46:18 2021 CET
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -64,17 +64,17 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 150 146 021 - 1491
|
||||
4 Start_Stop_Count -O--CK 098 098 000 - 2844
|
||||
3 Spin_Up_Time POS--K 149 146 021 - 1550
|
||||
4 Start_Stop_Count -O--CK 098 098 000 - 2851
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 099 099 000 - 875
|
||||
9 Power_On_Hours -O--CK 099 099 000 - 892
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 1144
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 1148
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 199 199 000 - 1000
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 2932
|
||||
192 Power-Off_Retract_Count -O--CK 199 199 000 - 1004
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 2936
|
||||
194 Temperature_Celsius -O---K 116 102 000 - 27
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
@@ -147,7 +147,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 128 (99)
|
||||
Temperature History Size (Index): 128 (80)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -165,12 +165,12 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 5 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 5 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 11 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 10 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 26835 Vendor specific
|
||||
0x8000 4 36909 Vendor specific
|
||||
|
||||
|
||||
|
||||
|
@@ -14,7 +14,7 @@ Form Factor: 2.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Wed Aug 26 11:20:08 2020 +08
|
||||
Local Time is: Wed Aug 26 11:25:50 2020 +08
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -79,7 +79,7 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
190 Airflow_Temperature_Cel -O---K 063 047 040 - 37 (Min/Max 23/40)
|
||||
191 G-Sense_Error_Rate -O--CK 001 001 000 - 125
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 111
|
||||
193 Load_Cycle_Count -O--CK 149 149 000 - 154057
|
||||
193 Load_Cycle_Count -O--CK 149 149 000 - 154063
|
||||
194 Temperature_Celsius -O---K 106 090 000 - 37
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
@@ -166,7 +166,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 128 (57)
|
||||
Temperature History Size (Index): 128 (63)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 85 (8.5 seconds)
|
||||
@@ -191,5 +191,5 @@ ID Size Value Description
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 10249 Vendor specific
|
||||
0x8000 4 10590 Vendor specific
|
||||
|
||||
|
Reference in New Issue