mirror of
https://github.com/bsdhw/SMART.git
synced 2025-05-31 16:21:41 +05:30
Update of reports (new: 0, modified: 1434)
This commit is contained in:
@@ -13,7 +13,7 @@ Rotation Rate: 5400 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Sat May 9 06:24:52 2020 CET
|
||||
Local Time is: Thu May 21 13:12:29 2020 MSK
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -64,17 +64,17 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 176 174 021 - 2175
|
||||
4 Start_Stop_Count -O--CK 097 097 000 - 3190
|
||||
3 Spin_Up_Time POS--K 177 174 021 - 2108
|
||||
4 Start_Stop_Count -O--CK 097 097 000 - 3201
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 086 086 000 - 10314
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 2607
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 131
|
||||
193 Load_Cycle_Count -O--CK 180 180 000 - 62472
|
||||
194 Temperature_Celsius -O---K 115 096 000 - 32
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 2618
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 137
|
||||
193 Load_Cycle_Count -O--CK 180 180 000 - 62491
|
||||
194 Temperature_Celsius -O---K 122 096 000 - 25
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
@@ -130,8 +130,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 32 Celsius
|
||||
Power Cycle Min/Max Temperature: 31/32 Celsius
|
||||
Current Temperature: 25 Celsius
|
||||
Power Cycle Min/Max Temperature: 24/25 Celsius
|
||||
Lifetime Min/Max Temperature: 13/52 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
@@ -143,7 +143,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 128 (8)
|
||||
Temperature History Size (Index): 128 (63)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -161,12 +161,10 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 11 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 7 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 5 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 415 Vendor specific
|
||||
|
||||
|
||||
0x8000 4 249 Vendor specific
|
||||
|
||||
|
Reference in New Issue
Block a user