1434 changed files with 30433 additions and 28411 deletions

View File

@@ -12,7 +12,7 @@ Rotation Rate: 5400 rpm
Device is: Not in smartctl database [for details use: -P showall]
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 3.0, 3.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Wed Sep 15 11:56:26 2021 CEST
Local Time is: Fri Sep 17 12:41:12 2021 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -63,18 +63,18 @@ SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
3 Spin_Up_Time POS--K 152 146 021 - 1391
4 Start_Stop_Count -O--CK 098 098 000 - 2859
3 Spin_Up_Time POS--K 151 146 021 - 1408
4 Start_Stop_Count -O--CK 098 098 000 - 2860
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
9 Power_On_Hours -O--CK 088 088 000 - 8817
9 Power_On_Hours -O--CK 088 088 000 - 8862
10 Spin_Retry_Count -O--CK 100 100 000 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
12 Power_Cycle_Count -O--CK 098 098 000 - 2852
12 Power_Cycle_Count -O--CK 098 098 000 - 2853
191 G-Sense_Error_Rate -O--CK 073 073 000 - 27
192 Power-Off_Retract_Count -O--CK 200 200 000 - 47
193 Load_Cycle_Count -O--CK 082 082 000 - 354126
194 Temperature_Celsius -O---K 105 096 000 - 38
193 Load_Cycle_Count -O--CK 082 082 000 - 354137
194 Temperature_Celsius -O---K 098 096 000 - 45
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--CK 200 200 000 - 0
198 Offline_Uncorrectable ----CK 100 253 000 - 0
@@ -128,8 +128,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 258 (0x0102)
Device State: Active (0)
Current Temperature: 38 Celsius
Power Cycle Min/Max Temperature: 27/40 Celsius
Current Temperature: 45 Celsius
Power Cycle Min/Max Temperature: 27/45 Celsius
Lifetime Min/Max Temperature: 22/47 Celsius
Under/Over Temperature Limit Count: 0/0
Vendor specific:
@@ -141,7 +141,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -41/85 Celsius
Temperature History Size (Index): 128 (95)
Temperature History Size (Index): 128 (11)
SCT Error Recovery Control command not supported
@@ -159,10 +159,10 @@ ID Size Value Description
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 14 Transition from drive PhyRdy to drive PhyNRdy
0x0009 2 8 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 4 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
0x8000 4 1722222 Vendor specific
0x8000 4 85431 Vendor specific