smartctl 7.2 2021-09-14 r5236 [FreeBSD 13.0-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p5 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Western Digital RE4
|
||||
@@ -10,10 +10,10 @@ Firmware Version: 01.01S03
|
||||
User Capacity: 500,107,862,016 bytes [500 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Tue Mar 8 21:17:20 2022 EST
|
||||
Local Time is: Wed Dec 28 14:57:02 2022 EST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,15 +65,15 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 130 128 021 - 4458
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 59
|
||||
3 Spin_Up_Time POS--K 130 128 021 - 4466
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 60
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 100 253 000 - 0
|
||||
9 Power_On_Hours -O--CK 074 074 000 - 19460
|
||||
9 Power_On_Hours -O--CK 074 074 000 - 19545
|
||||
10 Spin_Retry_Count -O--CK 100 253 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 253 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 59
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 45
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 60
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 46
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 110
|
||||
194 Temperature_Celsius -O---K 113 093 000 - 30
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
@@ -139,7 +139,7 @@ SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 30 Celsius
|
||||
Power Cycle Min/Max Temperature: 27/34 Celsius
|
||||
Power Cycle Min/Max Temperature: 23/30 Celsius
|
||||
Lifetime Min/Max Temperature: 0/51 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
@@ -148,7 +148,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (91)
|
||||
Temperature History Size (Index): 478 (446)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 70 (7.0 seconds)
|
||||
@@ -168,10 +168,10 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 60 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 40 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 18 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 12 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 20330416 Vendor specific
|
||||
0x8000 4 3631 Vendor specific
|
||||
|
||||
|
@@ -1,5 +1,5 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.1-RELEASE-p20-HBSD amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.0-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Western Digital RE4
|
||||
@@ -10,10 +10,10 @@ Firmware Version: 01.01S03
|
||||
User Capacity: 500,107,862,016 bytes [500 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Tue Sep 14 23:11:38 2021 CEST
|
||||
Local Time is: Tue Mar 29 11:49:08 2022 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -28,8 +28,8 @@ Wt Cache Reorder: Enabled
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Offline data collection status: (0x84) Offline data collection activity
|
||||
was suspended by an interrupting command from host.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
@@ -65,22 +65,22 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 132 131 021 - 4383
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 22
|
||||
3 Spin_Up_Time POS--K 134 131 021 - 4300
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 25
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 057 057 000 - 31644
|
||||
9 Power_On_Hours -O--CK 051 051 000 - 36332
|
||||
10 Spin_Retry_Count -O--CK 100 253 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 253 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 22
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 10
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 87
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 25
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 11
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 96
|
||||
194 Temperature_Celsius -O---K 105 099 000 - 38
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate ---R-- 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate ---R-- 200 200 000 - 1
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -167,10 +167,10 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 54 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 36 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 33 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 22 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 8902226 Vendor specific
|
||||
0x8000 4 13179914 Vendor specific
|
||||
|
||||
|
@@ -13,7 +13,7 @@ Rotation Rate: 7200 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Mon Feb 22 07:05:41 2021 CST
|
||||
Local Time is: Thu Apr 15 15:15:39 2021 CDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -64,15 +64,15 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 193 172 021 - 1333
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 714
|
||||
3 Spin_Up_Time POS--K 193 172 021 - 1308
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 716
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 028 028 000 - 53159
|
||||
9 Power_On_Hours -O--CK 026 026 000 - 54412
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 706
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 624
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 708
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 626
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 89
|
||||
194 Temperature_Celsius -O---K 116 096 000 - 27
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
@@ -131,8 +131,8 @@ SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 27 Celsius
|
||||
Power Cycle Min/Max Temperature: 26/29 Celsius
|
||||
Lifetime Min/Max Temperature: 26/47 Celsius
|
||||
Power Cycle Min/Max Temperature: 22/32 Celsius
|
||||
Lifetime Min/Max Temperature: 22/47 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
@@ -143,7 +143,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (289)
|
||||
Temperature History Size (Index): 478 (410)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -161,12 +161,12 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 53 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 54 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 47 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 48 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 1006963 Vendor specific
|
||||
0x8000 4 817316 Vendor specific
|
||||
|
||||
|
||||
|
||||
|
@@ -12,7 +12,7 @@ Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Mon Feb 22 07:05:40 2021 CST
|
||||
Local Time is: Thu Apr 15 15:15:39 2021 CDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -63,17 +63,17 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 193 172 021 - 1333
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 727
|
||||
3 Spin_Up_Time POS--K 194 172 021 - 1300
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 729
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 028 028 000 - 53273
|
||||
9 Power_On_Hours -O--CK 026 026 000 - 54527
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 718
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 640
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 720
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 642
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 86
|
||||
194 Temperature_Celsius -O---K 116 100 000 - 27
|
||||
194 Temperature_Celsius -O---K 114 100 000 - 29
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
@@ -130,9 +130,9 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 27 Celsius
|
||||
Power Cycle Min/Max Temperature: 27/29 Celsius
|
||||
Lifetime Min/Max Temperature: 27/43 Celsius
|
||||
Current Temperature: 29 Celsius
|
||||
Power Cycle Min/Max Temperature: 25/34 Celsius
|
||||
Lifetime Min/Max Temperature: 25/43 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
@@ -143,7 +143,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (295)
|
||||
Temperature History Size (Index): 478 (418)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -161,12 +161,12 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 26 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x0009 2 23 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 0 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 1006973 Vendor specific
|
||||
0x8000 4 817324 Vendor specific
|
||||
|
||||
|
||||
|
||||
|
@@ -12,7 +12,7 @@ Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Mon Feb 22 07:05:41 2021 CST
|
||||
Local Time is: Thu Apr 15 15:15:40 2021 CDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -63,15 +63,15 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 194 173 021 - 1258
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 717
|
||||
3 Spin_Up_Time POS--K 195 173 021 - 1250
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 719
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 043 043 000 - 42090
|
||||
9 Power_On_Hours -O--CK 041 041 000 - 43344
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 428
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 374
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 430
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 376
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 342
|
||||
194 Temperature_Celsius -O---K 115 100 000 - 28
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
@@ -130,8 +130,8 @@ SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 28 Celsius
|
||||
Power Cycle Min/Max Temperature: 27/30 Celsius
|
||||
Lifetime Min/Max Temperature: 27/43 Celsius
|
||||
Power Cycle Min/Max Temperature: 24/34 Celsius
|
||||
Lifetime Min/Max Temperature: 24/43 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
@@ -142,7 +142,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (121)
|
||||
Temperature History Size (Index): 478 (242)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -160,10 +160,10 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 53 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 53 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 47 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 46 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 1006951 Vendor specific
|
||||
0x8000 4 817306 Vendor specific
|
||||
|
||||
|
@@ -12,7 +12,7 @@ Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Mon Feb 22 07:05:40 2021 CST
|
||||
Local Time is: Thu Apr 15 15:15:38 2021 CDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -63,17 +63,17 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 193 173 021 - 1316
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 754
|
||||
3 Spin_Up_Time POS--K 194 173 021 - 1291
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 756
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 027 027 000 - 53484
|
||||
9 Power_On_Hours -O--CK 026 026 000 - 54738
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 745
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 659
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 747
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 661
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 94
|
||||
194 Temperature_Celsius -O---K 114 097 000 - 29
|
||||
194 Temperature_Celsius -O---K 113 097 000 - 30
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
@@ -130,9 +130,9 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 29 Celsius
|
||||
Power Cycle Min/Max Temperature: 28/31 Celsius
|
||||
Lifetime Min/Max Temperature: 28/46 Celsius
|
||||
Current Temperature: 30 Celsius
|
||||
Power Cycle Min/Max Temperature: 27/36 Celsius
|
||||
Lifetime Min/Max Temperature: 27/46 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
@@ -143,7 +143,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (130)
|
||||
Temperature History Size (Index): 478 (252)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -161,12 +161,12 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 53 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 27 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 47 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 24 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 1006970 Vendor specific
|
||||
0x8000 4 817321 Vendor specific
|
||||
|
||||
|
||||
|
||||
|
@@ -14,7 +14,7 @@ Form Factor: 3.5 inches
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-3 T13/2161-D revision 3b
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Mon Feb 22 07:05:40 2021 CST
|
||||
Local Time is: Thu Apr 15 15:15:39 2021 CDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,17 +65,17 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 190 184 021 - 1500
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 17
|
||||
3 Spin_Up_Time POS--K 186 184 021 - 1683
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 19
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 097 097 000 - 2850
|
||||
9 Power_On_Hours -O--CK 095 095 000 - 4103
|
||||
10 Spin_Retry_Count -O--CK 100 253 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 253 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 17
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 15
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 124
|
||||
194 Temperature_Celsius -O---K 117 112 000 - 26
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 19
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 17
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 151
|
||||
194 Temperature_Celsius -O---K 117 109 000 - 26
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
@@ -132,8 +132,8 @@ SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 26 Celsius
|
||||
Power Cycle Min/Max Temperature: 26/29 Celsius
|
||||
Lifetime Min/Max Temperature: 21/31 Celsius
|
||||
Power Cycle Min/Max Temperature: 23/32 Celsius
|
||||
Lifetime Min/Max Temperature: 21/34 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
01 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
@@ -144,7 +144,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (249)
|
||||
Temperature History Size (Index): 478 (369)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -162,13 +162,13 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 53 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 404 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 47 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 360 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 1006874 Vendor specific
|
||||
0x8000 4 817314 Vendor specific
|
||||
|
||||
|
||||
|
||||
|
@@ -13,7 +13,7 @@ Rotation Rate: 7200 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2, ACS-3 T13/2161-D revision 3b
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Mon Feb 22 07:05:40 2021 CST
|
||||
Local Time is: Thu Apr 15 15:15:38 2021 CDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,16 +65,16 @@ Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 190 171 021 - 1458
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 603
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 605
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 025 025 000 - 55002
|
||||
9 Power_On_Hours -O--CK 023 023 000 - 56256
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 596
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 522
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 1215
|
||||
194 Temperature_Celsius -O---K 114 099 000 - 29
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 598
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 524
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 1267
|
||||
194 Temperature_Celsius -O---K 112 099 000 - 31
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
@@ -128,8 +128,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 29 Celsius
|
||||
Power Cycle Min/Max Temperature: 28/32 Celsius
|
||||
Current Temperature: 31 Celsius
|
||||
Power Cycle Min/Max Temperature: 27/35 Celsius
|
||||
Lifetime Min/Max Temperature: 15/44 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
@@ -141,7 +141,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (345)
|
||||
Temperature History Size (Index): 478 (468)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -159,12 +159,12 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 53 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 143 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 47 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 120 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 1006974 Vendor specific
|
||||
0x8000 4 817325 Vendor specific
|
||||
|
||||
|
||||
|
||||
|
@@ -13,7 +13,7 @@ Rotation Rate: 7200 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2, ACS-3 T13/2161-D revision 3b
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Mon Feb 22 07:05:40 2021 CST
|
||||
Local Time is: Thu Apr 15 15:15:38 2021 CDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -64,17 +64,17 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 191 170 021 - 1441
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 760
|
||||
3 Spin_Up_Time POS--K 191 170 021 - 1433
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 762
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 022 022 000 - 57062
|
||||
9 Power_On_Hours -O--CK 021 021 000 - 58316
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 751
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 661
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 1172
|
||||
194 Temperature_Celsius -O---K 113 096 000 - 30
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 753
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 663
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 1223
|
||||
194 Temperature_Celsius -O---K 112 096 000 - 31
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
@@ -130,8 +130,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 30 Celsius
|
||||
Power Cycle Min/Max Temperature: 29/32 Celsius
|
||||
Current Temperature: 31 Celsius
|
||||
Power Cycle Min/Max Temperature: 27/36 Celsius
|
||||
Lifetime Min/Max Temperature: 15/47 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
@@ -143,7 +143,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (96)
|
||||
Temperature History Size (Index): 478 (219)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -161,12 +161,12 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 53 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 114 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 47 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 103 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 1006984 Vendor specific
|
||||
0x8000 4 817332 Vendor specific
|
||||
|
||||
|
||||
|
||||
|
@@ -13,7 +13,7 @@ Rotation Rate: 7200 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2, ACS-3 T13/2161-D revision 3b
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Mon Feb 22 07:05:40 2021 CST
|
||||
Local Time is: Thu Apr 15 15:15:39 2021 CDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -64,16 +64,16 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 192 174 021 - 1366
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 433
|
||||
3 Spin_Up_Time POS--K 192 174 021 - 1383
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 435
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 046 046 000 - 39847
|
||||
9 Power_On_Hours -O--CK 044 044 000 - 41101
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 430
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 380
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 1224
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 432
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 382
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 1286
|
||||
194 Temperature_Celsius -O---K 117 100 000 - 26
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
@@ -129,7 +129,7 @@ SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 26 Celsius
|
||||
Power Cycle Min/Max Temperature: 25/28 Celsius
|
||||
Power Cycle Min/Max Temperature: 22/31 Celsius
|
||||
Lifetime Min/Max Temperature: 0/43 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
@@ -141,7 +141,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (362)
|
||||
Temperature History Size (Index): 478 (6)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -159,12 +159,12 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 53 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 346 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 47 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 299 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 1006975 Vendor specific
|
||||
0x8000 4 817326 Vendor specific
|
||||
|
||||
|
||||
|
||||
|
@@ -13,7 +13,7 @@ Rotation Rate: 7200 rpm
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2, ACS-3 T13/2161-D revision 3b
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Mon Feb 22 07:05:39 2021 CST
|
||||
Local Time is: Thu Apr 15 15:15:38 2021 CDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -64,17 +64,17 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 19
|
||||
3 Spin_Up_Time POS--K 192 172 021 - 1366
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 775
|
||||
3 Spin_Up_Time POS--K 193 172 021 - 1350
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 777
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 022 022 000 - 57217
|
||||
9 Power_On_Hours -O--CK 020 020 000 - 58470
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 763
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 669
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 1908
|
||||
194 Temperature_Celsius -O---K 115 095 000 - 28
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 765
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 670
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 1983
|
||||
194 Temperature_Celsius -O---K 114 095 000 - 29
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
@@ -130,8 +130,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 28 Celsius
|
||||
Power Cycle Min/Max Temperature: 27/30 Celsius
|
||||
Current Temperature: 29 Celsius
|
||||
Power Cycle Min/Max Temperature: 25/35 Celsius
|
||||
Lifetime Min/Max Temperature: 0/48 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
Vendor specific:
|
||||
@@ -143,7 +143,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (317)
|
||||
Temperature History Size (Index): 478 (435)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -161,12 +161,12 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 41 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 52 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 35 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 43 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
0x0012 2 0 R_ERR response for host-to-device non-data FIS, CRC
|
||||
0x8000 4 1006919 Vendor specific
|
||||
0x8000 4 817316 Vendor specific
|
||||
|
||||
|
||||
|
||||
|