smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.0-STABLE amd64] (local build)
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p2 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -12,7 +12,7 @@ Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 2.5, 3.0 Gb/s
|
||||
Local Time is: Thu Jul 28 18:13:06 2022 EDT
|
||||
Local Time is: Sun Sep 11 02:37:21 2022 EDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
@@ -63,17 +63,17 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 4
|
||||
3 Spin_Up_Time POS--K 163 160 021 - 4850
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 641
|
||||
3 Spin_Up_Time POS--K 175 160 021 - 4216
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 647
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 001 001 000 - 97074
|
||||
9 Power_On_Hours -O--CK 001 001 000 - 98085
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 638
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 161
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 641
|
||||
194 Temperature_Celsius -O---K 108 085 000 - 39
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 644
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 166
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 647
|
||||
194 Temperature_Celsius -O---K 113 085 000 - 34
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 23
|
||||
@@ -276,9 +276,9 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: SMART Off-line Data Collection executing in background (4)
|
||||
Current Temperature: 39 Celsius
|
||||
Power Cycle Min/Max Temperature: 31/44 Celsius
|
||||
Lifetime Min/Max Temperature: 35/62 Celsius
|
||||
Current Temperature: 34 Celsius
|
||||
Power Cycle Min/Max Temperature: 26/38 Celsius
|
||||
Lifetime Min/Max Temperature: 34/62 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
@@ -286,7 +286,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 128 (94)
|
||||
Temperature History Size (Index): 128 (54)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
@@ -303,6 +303,6 @@ ID Size Value Description
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000a 2 18 Device-to-host register FISes sent due to a COMRESET
|
||||
0x8000 4 4813274 Vendor specific
|
||||
0x000a 2 4 Device-to-host register FISes sent due to a COMRESET
|
||||
0x8000 4 888699 Vendor specific
|
||||
|
||||
|