1
0
mirror of https://github.com/bsdhw/SMART.git synced 2025-05-31 16:21:41 +05:30

Update of reports (new: 0, modified: 1434)

This commit is contained in:
Andrey Ponomarenko
2023-02-16 00:05:51 +03:00
parent 67063db0cd
commit 22f0da8c56
1434 changed files with 30433 additions and 28411 deletions

View File

@@ -1,4 +1,4 @@
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.0-STABLE amd64] (local build)
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p2 amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
@@ -12,7 +12,7 @@ Sector Size: 512 bytes logical/physical
Device is: In smartctl database 7.3/5319
ATA Version is: ATA8-ACS (minor revision not indicated)
SATA Version is: SATA 2.5, 3.0 Gb/s
Local Time is: Thu Jul 28 18:13:06 2022 EDT
Local Time is: Sun Sep 11 02:37:21 2022 EDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Disabled
@@ -63,17 +63,17 @@ SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 4
3 Spin_Up_Time POS--K 163 160 021 - 4850
4 Start_Stop_Count -O--CK 100 100 000 - 641
3 Spin_Up_Time POS--K 175 160 021 - 4216
4 Start_Stop_Count -O--CK 100 100 000 - 647
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
9 Power_On_Hours -O--CK 001 001 000 - 97074
9 Power_On_Hours -O--CK 001 001 000 - 98085
10 Spin_Retry_Count -O--CK 100 100 000 - 0
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
12 Power_Cycle_Count -O--CK 100 100 000 - 638
192 Power-Off_Retract_Count -O--CK 200 200 000 - 161
193 Load_Cycle_Count -O--CK 200 200 000 - 641
194 Temperature_Celsius -O---K 108 085 000 - 39
12 Power_Cycle_Count -O--CK 100 100 000 - 644
192 Power-Off_Retract_Count -O--CK 200 200 000 - 166
193 Load_Cycle_Count -O--CK 200 200 000 - 647
194 Temperature_Celsius -O---K 113 085 000 - 34
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
197 Current_Pending_Sector -O--CK 200 200 000 - 0
198 Offline_Uncorrectable ----CK 200 200 000 - 23
@@ -276,9 +276,9 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 2
SCT Version (vendor specific): 258 (0x0102)
Device State: SMART Off-line Data Collection executing in background (4)
Current Temperature: 39 Celsius
Power Cycle Min/Max Temperature: 31/44 Celsius
Lifetime Min/Max Temperature: 35/62 Celsius
Current Temperature: 34 Celsius
Power Cycle Min/Max Temperature: 26/38 Celsius
Lifetime Min/Max Temperature: 34/62 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
@@ -286,7 +286,7 @@ Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/60 Celsius
Min/Max Temperature Limit: -41/85 Celsius
Temperature History Size (Index): 128 (94)
Temperature History Size (Index): 128 (54)
SCT Error Recovery Control command not supported
@@ -303,6 +303,6 @@ ID Size Value Description
0x0005 2 0 R_ERR response for non-data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x000a 2 18 Device-to-host register FISes sent due to a COMRESET
0x8000 4 4813274 Vendor specific
0x000a 2 4 Device-to-host register FISes sent due to a COMRESET
0x8000 4 888699 Vendor specific