mirror of
https://github.com/bsdhw/SMART.git
synced 2025-05-31 16:21:41 +05:30
Update of reports (new: 0, modified: 1434)
This commit is contained in:
@@ -1,4 +1,4 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 12.3-RELEASE amd64] (local build)
|
||||
smartctl 7.2 2021-09-14 r5236 [FreeBSD 12.3-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
@@ -10,7 +10,7 @@ User Capacity: 80,000,000,000 bytes [80.0 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ATA/ATAPI-7 (minor revision not indicated)
|
||||
Local Time is: Mon Jan 10 15:28:58 2022 EST
|
||||
Local Time is: Mon Jan 10 16:19:35 2022 EST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
@@ -63,16 +63,16 @@ SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 200 200 051 - 0
|
||||
3 Spin_Up_Time PO---- 166 160 021 - 2683
|
||||
4 Start_Stop_Count -O--CK 099 099 000 - 1758
|
||||
3 Spin_Up_Time PO---- 167 160 021 - 2633
|
||||
4 Start_Stop_Count -O--CK 099 099 000 - 1764
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate POSR-- 200 200 051 - 0
|
||||
9 Power_On_Hours -O--CK 088 088 000 - 8867
|
||||
10 Spin_Retry_Count PO--C- 100 100 051 - 0
|
||||
11 Calibration_Retry_Count -O--C- 100 100 051 - 0
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 1756
|
||||
190 Airflow_Temperature_Cel -O---K 068 040 045 Past 32
|
||||
194 Temperature_Celsius -O---K 111 083 000 - 32
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 1759
|
||||
190 Airflow_Temperature_Cel -O---K 060 040 045 Past 40
|
||||
194 Temperature_Celsius -O---K 103 083 000 - 40
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--C- 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 200 200 000 - 0
|
||||
@@ -126,8 +126,8 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 32 Celsius
|
||||
Power Cycle Min/Max Temperature: --/32 Celsius
|
||||
Current Temperature: 36 Celsius
|
||||
Power Cycle Min/Max Temperature: --/45 Celsius
|
||||
Lifetime Min/Max Temperature: --/64 Celsius
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
@@ -135,7 +135,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 5/65 Celsius
|
||||
Min/Max Temperature Limit: 1/70 Celsius
|
||||
Temperature History Size (Index): 128 (82)
|
||||
Temperature History Size (Index): 128 (112)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -148,6 +148,6 @@ Pending Defects log (GP Log 0x0c) not supported
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x000a 2 12 Device-to-host register FISes sent due to a COMRESET
|
||||
0x8000 4 1553 Vendor specific
|
||||
0x000a 2 7 Device-to-host register FISes sent due to a COMRESET
|
||||
0x8000 4 802 Vendor specific
|
||||
|
||||
|
Reference in New Issue
Block a user