mirror of
https://github.com/bsdhw/SMART.git
synced 2025-05-31 16:21:41 +05:30
Update of reports (new: 0, modified: 1434)
This commit is contained in:
@@ -13,7 +13,7 @@ TRIM Command: Available
|
||||
Device is: Not in smartctl database [for details use: -P showall]
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sun Aug 15 07:14:54 2021 CDT
|
||||
Local Time is: Thu Aug 26 02:18:14 2021 CDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -64,7 +64,7 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 1254
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 1258
|
||||
175 Program_Fail_Count_Chip -O--CK 100 100 010 - 0
|
||||
176 Erase_Fail_Count_Chip -O--CK 100 100 010 - 0
|
||||
177 Wear_Leveling_Count PO--C- 094 094 005 - 71
|
||||
@@ -75,8 +75,8 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
195 Hardware_ECC_Recovered -O-RC- 200 200 000 - 0
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 25771208270
|
||||
242 Total_LBAs_Read -O--CK 099 099 000 - 25923068694
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 25850547694
|
||||
242 Total_LBAs_Read -O--CK 099 099 000 - 25935687130
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -125,14 +125,14 @@ Device State: Active (0)
|
||||
Current Temperature: 38 Celsius
|
||||
Power Cycle Min/Max Temperature: ?/ ? Celsius
|
||||
Lifetime Min/Max Temperature: ?/ ? Celsius
|
||||
Under/Over Temperature Limit Count: 0/212412
|
||||
Under/Over Temperature Limit Count: 0/213973
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 10 minutes
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: ?/ ? Celsius
|
||||
Min/Max Temperature Limit: ?/ ? Celsius
|
||||
Temperature History Size (Index): 128 (119)
|
||||
Temperature History Size (Index): 128 (9)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
|
@@ -14,7 +14,7 @@ TRIM Command: Available
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 4c
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Fri Oct 15 07:57:44 2021 BST
|
||||
Local Time is: Thu Oct 21 09:32:55 2021 BST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,10 +65,10 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
12 Power_Cycle_Count -O--CK 097 097 000 - 2464
|
||||
12 Power_Cycle_Count -O--CK 097 097 000 - 2478
|
||||
175 Program_Fail_Count_Chip -O--CK 100 100 010 - 0
|
||||
176 Erase_Fail_Count_Chip -O--CK 100 100 010 - 0
|
||||
177 Wear_Leveling_Count PO--C- 081 081 005 - 228
|
||||
177 Wear_Leveling_Count PO--C- 081 081 005 - 229
|
||||
178 Used_Rsvd_Blk_Cnt_Chip PO--C- 100 100 010 - 0
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
|
||||
180 Unused_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 4423
|
||||
@@ -76,8 +76,8 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 63085798702
|
||||
242 Total_LBAs_Read -O--CK 099 099 000 - 67274900113
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 63494682644
|
||||
242 Total_LBAs_Read -O--CK 099 099 000 - 67734015941
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -141,17 +141,17 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 36 Celsius
|
||||
Current Temperature: 45 Celsius
|
||||
Power Cycle Min/Max Temperature: ?/ ? Celsius
|
||||
Lifetime Min/Max Temperature: ?/ ? Celsius
|
||||
Under/Over Temperature Limit Count: 0/78440
|
||||
Under/Over Temperature Limit Count: 0/78629
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 10 minutes
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: ?/ ? Celsius
|
||||
Min/Max Temperature Limit: ?/ ? Celsius
|
||||
Temperature History Size (Index): 128 (1)
|
||||
Temperature History Size (Index): 128 (3)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -171,8 +171,8 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 3 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 9 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 14 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|
Reference in New Issue
Block a user