1
0
mirror of https://github.com/bsdhw/SMART.git synced 2025-05-31 16:21:41 +05:30

Update of reports (new: 0, modified: 706)

This commit is contained in:
Andrey Ponomarenko
2023-05-01 23:00:07 +03:00
parent 6760e6c317
commit 23ed3f49e3
706 changed files with 14188 additions and 13649 deletions

View File

@@ -13,7 +13,7 @@ TRIM Command: Available, deterministic, zeroed
Device is: Not in smartctl database 7.3/5319
ATA Version is: ATA8-ACS, ATA/ATAPI-7 T13/1532D revision 4a
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Fri Feb 17 00:10:41 2023 KST
Local Time is: Thu Feb 23 03:39:13 2023 KST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
@@ -62,9 +62,9 @@ SMART Attributes Data Structure revision number: 1
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
5 Reallocated_Sector_Ct PO---- 100 100 000 - 0
9 Power_On_Hours -O---- 100 100 000 - 1925
12 Power_Cycle_Count PO---- 100 100 000 - 1245
177 Wear_Leveling_Count PO---- 100 100 000 - 1504818
9 Power_On_Hours -O---- 100 100 000 - 1927
12 Power_Cycle_Count PO---- 100 100 000 - 1247
177 Wear_Leveling_Count PO---- 100 100 000 - 1504883
179 Used_Rsvd_Blk_Cnt_Tot PO--CK 100 100 010 - 512
181 Program_Fail_Cnt_Total PO---- 100 100 000 - 0
182 Erase_Fail_Count_Total PO---- 100 100 000 - 0
@@ -73,8 +73,8 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
190 Airflow_Temperature_Cel -O--CK 100 100 000 - 50
199 UDMA_CRC_Error_Count PO---- 100 100 000 - 0
235 Unknown_Attribute PO---- 100 100 000 - 315
241 Total_LBAs_Written PO---- 100 100 000 - 19453
242 Total_LBAs_Read PO---- 100 100 000 - 38149
241 Total_LBAs_Written PO---- 100 100 000 - 19484
242 Total_LBAs_Read PO---- 100 100 000 - 38152
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
@@ -112,7 +112,7 @@ Selective Self-tests/Logging not supported
SCT Status Version: 3
SCT Version (vendor specific): 1 (0x0001)
Device State: Active (0)
Current Temperature: 41 Celsius
Current Temperature: 49 Celsius
Power Cycle Min/Max Temperature: ?/ ? Celsius
Lifetime Min/Max Temperature: ?/ ? Celsius
Under/Over Temperature Limit Count: 0/0
@@ -138,7 +138,7 @@ ID Size Value Description
0x0007 2 0 R_ERR response for host-to-device non-data FIS
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 0 Transition from drive PhyRdy to drive PhyNRdy
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
0x000a 2 6 Device-to-host register FISes sent due to a COMRESET
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC