mirror of
https://github.com/bsdhw/SMART.git
synced 2025-05-31 16:21:41 +05:30
Update of reports (new: 0, modified: 706)
This commit is contained in:
@@ -15,7 +15,7 @@ TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sun Apr 30 21:47:54 2023 UTC
|
||||
Local Time is: Sun Apr 30 22:02:13 2023 UTC
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,7 +65,7 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 097 097 000 - 12605
|
||||
9 Power_On_Hours -O--CK 097 097 000 - 12606
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 1951
|
||||
177 Wear_Leveling_Count PO--C- 097 097 000 - 45
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
|
||||
@@ -73,11 +73,11 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
183 Runtime_Bad_Block PO--C- 100 100 010 - 0
|
||||
187 Uncorrectable_Error_Cnt -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O--CK 074 049 000 - 26
|
||||
190 Airflow_Temperature_Cel -O--CK 073 049 000 - 27
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 099 099 000 - 1
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 685
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 78643561505
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 78646470209
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -127,7 +127,7 @@ If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 26 Celsius
|
||||
Current Temperature: 27 Celsius
|
||||
Power Cycle Min/Max Temperature: 24/40 Celsius
|
||||
Lifetime Min/Max Temperature: 13/51 Celsius
|
||||
Specified Max Operating Temperature: 70 Celsius
|
||||
@@ -139,7 +139,7 @@ Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (118)
|
||||
Temperature History Size (Index): 128 (119)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -149,17 +149,17 @@ Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 1951 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 12605 --- Power-on Hours
|
||||
0x01 0x018 6 78643561505 --- Logical Sectors Written
|
||||
0x01 0x020 6 590860459 --- Number of Write Commands
|
||||
0x01 0x028 6 45787563456 --- Logical Sectors Read
|
||||
0x01 0x030 6 504938951 --- Number of Read Commands
|
||||
0x01 0x038 6 3163000 --- Date and Time TimeStamp
|
||||
0x01 0x010 4 12606 --- Power-on Hours
|
||||
0x01 0x018 6 78646470209 --- Logical Sectors Written
|
||||
0x01 0x020 6 590889204 --- Number of Write Commands
|
||||
0x01 0x028 6 45787895128 --- Logical Sectors Read
|
||||
0x01 0x030 6 504943074 --- Number of Read Commands
|
||||
0x01 0x038 6 422000 --- Date and Time TimeStamp
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 1771 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 26 --- Current Temperature
|
||||
0x05 0x008 1 27 --- Current Temperature
|
||||
0x05 0x020 1 51 --- Highest Temperature
|
||||
0x05 0x028 1 13 --- Lowest Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
|
@@ -1,5 +1,5 @@
|
||||
smartctl 7.2 2020-12-30 r5155 [FreeBSD 13.1-RELEASE-p3 amd64] (local build)
|
||||
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Samsung based SSDs
|
||||
@@ -12,10 +12,10 @@ Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
Form Factor: 2.5 inches
|
||||
TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database [for details use: -P show]
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-4 T13/BSR INCITS 529 revision 5
|
||||
SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat Nov 19 07:19:55 2022 EST
|
||||
Local Time is: Fri Mar 17 15:07:35 2023 UTC
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
@@ -65,9 +65,9 @@ SMART Attributes Data Structure revision number: 1
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 0
|
||||
9 Power_On_Hours -O--CK 099 099 000 - 1753
|
||||
12 Power_Cycle_Count -O--CK 096 096 000 - 3147
|
||||
177 Wear_Leveling_Count PO--C- 097 097 000 - 40
|
||||
9 Power_On_Hours -O--CK 099 099 000 - 2053
|
||||
12 Power_Cycle_Count -O--CK 096 096 000 - 3586
|
||||
177 Wear_Leveling_Count PO--C- 097 097 000 - 47
|
||||
179 Used_Rsvd_Blk_Cnt_Tot PO--C- 100 100 010 - 0
|
||||
181 Program_Fail_Cnt_Total -O--CK 100 100 010 - 0
|
||||
182 Erase_Fail_Count_Total -O--CK 100 100 010 - 0
|
||||
@@ -76,8 +76,8 @@ ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
190 Airflow_Temperature_Cel -O--CK 078 055 000 - 22
|
||||
195 ECC_Error_Rate -O-RC- 200 200 000 - 0
|
||||
199 CRC_Error_Count -OSRCK 100 100 000 - 0
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 442
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 34485559858
|
||||
235 POR_Recovery_Count -O--C- 099 099 000 - 487
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 41798952628
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
@@ -132,8 +132,8 @@ SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 22 Celsius
|
||||
Power Cycle Min/Max Temperature: 20/40 Celsius
|
||||
Lifetime Min/Max Temperature: 18/45 Celsius
|
||||
Power Cycle Min/Max Temperature: 17/22 Celsius
|
||||
Lifetime Min/Max Temperature: 17/45 Celsius
|
||||
Specified Max Operating Temperature: 70 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
SMART Status: 0xc24f (PASSED)
|
||||
@@ -143,7 +143,7 @@ Temperature Sampling Period: 10 minutes
|
||||
Temperature Logging Interval: 10 minutes
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: 0/70 Celsius
|
||||
Temperature History Size (Index): 128 (121)
|
||||
Temperature History Size (Index): 128 (110)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
@@ -152,23 +152,23 @@ SCT Error Recovery Control:
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 1) ==
|
||||
0x01 0x008 4 3147 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 1753 --- Power-on Hours
|
||||
0x01 0x018 6 34485559858 --- Logical Sectors Written
|
||||
0x01 0x020 6 292160161 --- Number of Write Commands
|
||||
0x01 0x028 6 32584008383 --- Logical Sectors Read
|
||||
0x01 0x030 6 328172817 --- Number of Read Commands
|
||||
0x01 0x038 6 1423000 --- Date and Time TimeStamp
|
||||
0x01 0x008 4 3586 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 2053 --- Power-on Hours
|
||||
0x01 0x018 6 41798952628 --- Logical Sectors Written
|
||||
0x01 0x020 6 353895313 --- Number of Write Commands
|
||||
0x01 0x028 6 45595869783 --- Logical Sectors Read
|
||||
0x01 0x030 6 447313838 --- Number of Read Commands
|
||||
0x01 0x038 6 1836000 --- Date and Time TimeStamp
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 0 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 22 --- Current Temperature
|
||||
0x05 0x020 1 45 --- Highest Temperature
|
||||
0x05 0x028 1 18 --- Lowest Temperature
|
||||
0x05 0x028 1 17 --- Lowest Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 9967 --- Number of Hardware Resets
|
||||
0x06 0x008 4 11852 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
@@ -189,8 +189,8 @@ ID Size Value Description
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 11 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 11 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0009 2 5 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 4 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x000f 2 0 R_ERR response for host-to-device data FIS, CRC
|
||||
|
Reference in New Issue
Block a user