smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.1-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Device Model: APPLE HDD HTS541010A9E662
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000cca ...
|
||||
Firmware Version: JA0AB5D0
|
||||
User Capacity: 1,000,204,886,016 bytes [1.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5400 rpm
|
||||
Form Factor: 2.5 inches
|
||||
Device is: Not in smartctl database 7.3/5528
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Mon Jun 10 09:39:18 2024 BST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Unknown
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART Status not supported: Incomplete response, ATA output registers missing
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
Warning: This result is based on an Attribute check.
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 45) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 215) minutes.
|
||||
SCT capabilities: (0x003d) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate PO-R-- 100 100 062 - 0
|
||||
2 Throughput_Performance P-S--- 100 100 040 - 0
|
||||
3 Spin_Up_Time POS--- 250 250 033 - 1
|
||||
4 Start_Stop_Count -O--C- 093 093 000 - 12439
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
|
||||
7 Seek_Error_Rate PO-R-- 100 100 067 - 0
|
||||
8 Seek_Time_Performance P-S--- 100 100 040 - 0
|
||||
9 Power_On_Hours -O--C- 074 074 000 - 11635
|
||||
10 Spin_Retry_Count PO--C- 100 100 060 - 0
|
||||
12 Power_Cycle_Count -O--CK 094 094 000 - 10681
|
||||
160 Unknown_Attribute -O--CK 100 100 000 - 0
|
||||
191 G-Sense_Error_Rate -O-R-- 099 099 000 - 2
|
||||
192 Power-Off_Retract_Count -O--CK 097 097 000 - 34359738985
|
||||
193 Load_Cycle_Count -O--C- 007 007 000 - 936047
|
||||
194 Temperature_Celsius -O---- 253 253 000 - 22 (Min/Max 9/50)
|
||||
195 Hardware_ECC_Recovered -O-R-- 100 100 000 - 0
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O---K 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ---R-- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 1
|
||||
223 Load_Retry_Count -O-R-- 100 100 000 - 0
|
||||
254 Free_Fall_Sensor -O--CK 100 100 000 - 42
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 1 Comprehensive SMART error log
|
||||
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
Device Error Count: 1
|
||||
CR = Command Register
|
||||
FEATR = Features Register
|
||||
COUNT = Count (was: Sector Count) Register
|
||||
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
|
||||
LH = LBA High (was: Cylinder High) Register ] LBA
|
||||
LM = LBA Mid (was: Cylinder Low) Register ] Register
|
||||
LL = LBA Low (was: Sector Number) Register ]
|
||||
DV = Device (was: Device/Head) Register
|
||||
DC = Device Control Register
|
||||
ER = Error register
|
||||
ST = Status register
|
||||
Powered_Up_Time is measured from power on, and printed as
|
||||
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
||||
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
||||
|
||||
Error 1 [0] occurred at disk power-on lifetime: 10914 hours (454 days + 18 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
84 -- 51 02 51 00 00 66 30 0a 5f 06 00 Error: ICRC, ABRT 593 sectors at LBA = 0x66300a5f = 1714424415
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
25 ff ff 04 00 00 00 66 30 08 b0 40 00 00:05:15.804 READ DMA EXT
|
||||
25 ff ff 04 00 00 00 66 30 04 b0 40 00 00:05:15.802 READ DMA EXT
|
||||
35 ff ff 04 00 00 00 6e b4 7e 50 40 00 00:05:15.793 WRITE DMA EXT
|
||||
35 ff ff 04 00 00 00 6e b4 7a 50 40 00 00:05:15.789 WRITE DMA EXT
|
||||
25 ff ff 04 00 00 00 66 30 00 b0 40 00 00:05:15.787 READ DMA EXT
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Interrupted (host reset) 90% 9891 -
|
||||
# 2 Short offline Interrupted (host reset) 90% 9891 -
|
||||
# 3 Short offline Interrupted (host reset) 90% 9891 -
|
||||
# 4 Short offline Interrupted (host reset) 90% 9888 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 22 Celsius
|
||||
Power Cycle Min/Max Temperature: 16/22 Celsius
|
||||
Lifetime Min/Max Temperature: 9/50 Celsius
|
||||
Specified Max Operating Temperature: 28 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -40/65 Celsius
|
||||
Temperature History Size (Index): 128 (105)
|
||||
|
||||
SMART WRITE LOG does not return COUNT and LBA_LOW register
|
||||
SCT (Get) Error Recovery Control command failed
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0009 2 8 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 8 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
||||
|
||||
|
167
HDD/Apple/HDD HTS5410/HDD HTS541010A9E662/1F9332881ABC
Normal file
167
HDD/Apple/HDD HTS5410/HDD HTS541010A9E662/1F9332881ABC
Normal file
@@ -0,0 +1,167 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Device Model: APPLE HDD HTS541010A9E662
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000cca ...
|
||||
Firmware Version: JA0AB560
|
||||
User Capacity: 1,000,204,886,016 bytes [1.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5400 rpm
|
||||
Form Factor: 2.5 inches
|
||||
Device is: Not in smartctl database 7.3/5319
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Sun Nov 19 12:48:01 2023 UTC
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 45) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 253) minutes.
|
||||
SCT capabilities: (0x003d) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate PO-R-- 100 100 062 - 0
|
||||
2 Throughput_Performance P-S--- 100 100 040 - 0
|
||||
3 Spin_Up_Time POS--- 176 176 033 - 1
|
||||
4 Start_Stop_Count -O--C- 098 098 000 - 4360
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
|
||||
7 Seek_Error_Rate PO-R-- 100 100 067 - 0
|
||||
8 Seek_Time_Performance P-S--- 100 100 040 - 0
|
||||
9 Power_On_Hours -O--C- 084 084 000 - 7103
|
||||
10 Spin_Retry_Count PO--C- 100 100 060 - 0
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 4353
|
||||
160 Unknown_Attribute -O--CK 100 100 000 - 0
|
||||
191 G-Sense_Error_Rate -O-R-- 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 099 099 000 - 12884902096
|
||||
193 Load_Cycle_Count -O--C- 068 068 000 - 323195
|
||||
194 Temperature_Celsius -O---- 193 193 000 - 31 (Min/Max 14/49)
|
||||
195 Hardware_ECC_Recovered -O-R-- 100 100 000 - 0
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O---K 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ---R-- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 0
|
||||
223 Load_Retry_Count -O-R-- 100 100 000 - 0
|
||||
254 Free_Fall_Sensor -O--CK 100 100 000 - 11
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 1 Comprehensive SMART error log
|
||||
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Aborted by host 60% 6453 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 31 Celsius
|
||||
Power Cycle Min/Max Temperature: 28/31 Celsius
|
||||
Lifetime Min/Max Temperature: 14/49 Celsius
|
||||
Specified Max Operating Temperature: 33 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -40/65 Celsius
|
||||
Temperature History Size (Index): 128 (101)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0009 2 50 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 7 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
||||
|
||||
|
164
HDD/Apple/HDD HTS5410/HDD HTS541010A9E662/7F062DDE02B3
Normal file
164
HDD/Apple/HDD HTS5410/HDD HTS541010A9E662/7F062DDE02B3
Normal file
@@ -0,0 +1,164 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.1-RELEASE-p3 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Device Model: APPLE HDD HTS541010A9E662
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000cca ...
|
||||
Firmware Version: JA0AB5D0
|
||||
User Capacity: 1,000,204,886,016 bytes [1.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5400 rpm
|
||||
Form Factor: 2.5 inches
|
||||
Device is: Not in smartctl database 7.3/5528
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Mon Aug 12 22:37:26 2024 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 45) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 212) minutes.
|
||||
SCT capabilities: (0x003d) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate PO-R-- 100 100 062 - 0
|
||||
2 Throughput_Performance P-S--- 100 100 040 - 0
|
||||
3 Spin_Up_Time POS--- 162 162 033 - 1
|
||||
4 Start_Stop_Count -O--C- 100 100 000 - 681
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
|
||||
7 Seek_Error_Rate PO-R-- 100 100 067 - 0
|
||||
8 Seek_Time_Performance P-S--- 100 100 040 - 0
|
||||
9 Power_On_Hours -O--C- 001 001 000 - 63317
|
||||
10 Spin_Retry_Count PO--C- 100 100 060 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 681
|
||||
160 Unknown_Attribute -O--CK 100 100 000 - 0
|
||||
191 G-Sense_Error_Rate -O-R-- 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 66
|
||||
193 Load_Cycle_Count -O--C- 001 001 000 - 4438812
|
||||
194 Temperature_Celsius -O---- 133 133 000 - 45 (Min/Max 15/57)
|
||||
195 Hardware_ECC_Recovered -O-R-- 100 100 000 - 0
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O---K 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ---R-- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 0
|
||||
223 Load_Retry_Count -O-R-- 100 100 000 - 0
|
||||
254 Free_Fall_Sensor -O--CK 100 100 000 - 62
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 1 Comprehensive SMART error log
|
||||
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 45 Celsius
|
||||
Power Cycle Min/Max Temperature: 41/49 Celsius
|
||||
Lifetime Min/Max Temperature: 15/57 Celsius
|
||||
Specified Max Operating Temperature: 38 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -40/65 Celsius
|
||||
Temperature History Size (Index): 128 (50)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0009 2 4 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
164
HDD/Apple/HDD HTS5410/HDD HTS541010A9E662/C6D6F5FF66D2
Normal file
164
HDD/Apple/HDD HTS5410/HDD HTS541010A9E662/C6D6F5FF66D2
Normal file
@@ -0,0 +1,164 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p7 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Device Model: APPLE HDD HTS541010A9E662
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000cca ...
|
||||
Firmware Version: JA0AB560
|
||||
User Capacity: 1,000,204,886,016 bytes [1.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5400 rpm
|
||||
Form Factor: 2.5 inches
|
||||
Device is: Not in smartctl database 7.3/5319
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Sun Jun 11 21:52:04 2023 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 45) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 222) minutes.
|
||||
SCT capabilities: (0x003d) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate PO-R-- 100 100 062 - 0
|
||||
2 Throughput_Performance P-S--- 100 100 040 - 0
|
||||
3 Spin_Up_Time POS--- 167 167 033 - 1
|
||||
4 Start_Stop_Count -O--C- 099 099 000 - 3136
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
|
||||
7 Seek_Error_Rate PO-R-- 100 100 067 - 0
|
||||
8 Seek_Time_Performance P-S--- 100 100 040 - 0
|
||||
9 Power_On_Hours -O--C- 061 061 000 - 17120
|
||||
10 Spin_Retry_Count PO--C- 100 100 060 - 0
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 2455
|
||||
160 Unknown_Attribute -O--CK 100 100 000 - 0
|
||||
191 G-Sense_Error_Rate -O-R-- 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 8589934647
|
||||
193 Load_Cycle_Count -O--C- 049 049 000 - 519255
|
||||
194 Temperature_Celsius -O---- 120 120 000 - 50 (Min/Max 11/56)
|
||||
195 Hardware_ECC_Recovered -O-R-- 100 100 000 - 0
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O---K 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ---R-- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 0
|
||||
223 Load_Retry_Count -O-R-- 100 100 000 - 0
|
||||
254 Free_Fall_Sensor -O--CK 100 100 000 - 132
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 1 Comprehensive SMART error log
|
||||
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 50 Celsius
|
||||
Power Cycle Min/Max Temperature: 43/56 Celsius
|
||||
Lifetime Min/Max Temperature: 11/56 Celsius
|
||||
Specified Max Operating Temperature: 35 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -40/65 Celsius
|
||||
Temperature History Size (Index): 128 (65)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0009 2 2 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
199
HDD/Apple/HDD HTS5410/HDD HTS541010A9E682/B232A1EB29D9
Normal file
199
HDD/Apple/HDD HTS5410/HDD HTS541010A9E682/B232A1EB29D9
Normal file
@@ -0,0 +1,199 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Device Model: APPLE HDD HTS541010A9E682
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000cca ...
|
||||
Firmware Version: JA0AB4E0
|
||||
User Capacity: 1,000,204,886,016 bytes [1.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5400 rpm
|
||||
Form Factor: 2.5 inches
|
||||
Device is: Not in smartctl database 7.3/5319
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Wed Oct 11 12:50:22 2023 UTC
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 45) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 227) minutes.
|
||||
SCT capabilities: (0x003d) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate PO-R-- 100 100 062 - 0
|
||||
2 Throughput_Performance P-S--- 198 198 040 - 127
|
||||
3 Spin_Up_Time POS--- 206 206 033 - 1
|
||||
4 Start_Stop_Count -O--C- 086 086 000 - 22616
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
|
||||
7 Seek_Error_Rate PO-R-- 100 100 067 - 0
|
||||
8 Seek_Time_Performance P-S--- 115 115 040 - 34
|
||||
9 Power_On_Hours -O--C- 061 061 000 - 17369
|
||||
10 Spin_Retry_Count PO--C- 100 100 060 - 0
|
||||
12 Power_Cycle_Count -O--CK 089 089 000 - 18799
|
||||
160 Unknown_Attribute -O--CK 100 100 000 - 0
|
||||
191 G-Sense_Error_Rate -O-R-- 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 092 092 000 - 2199024108747
|
||||
193 Load_Cycle_Count -O--C- 042 042 000 - 582368
|
||||
194 Temperature_Celsius -O---- 193 193 000 - 31 (Min/Max 6/49)
|
||||
195 Hardware_ECC_Recovered -O-R-- 100 100 000 - 0
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O---K 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ---R-- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 0
|
||||
223 Load_Retry_Count -O-R-- 100 100 000 - 0
|
||||
254 Free_Fall_Sensor -O--CK 091 091 000 - 2425
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 1 Comprehensive SMART error log
|
||||
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
Device Error Count: 1
|
||||
CR = Command Register
|
||||
FEATR = Features Register
|
||||
COUNT = Count (was: Sector Count) Register
|
||||
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
|
||||
LH = LBA High (was: Cylinder High) Register ] LBA
|
||||
LM = LBA Mid (was: Cylinder Low) Register ] Register
|
||||
LL = LBA Low (was: Sector Number) Register ]
|
||||
DV = Device (was: Device/Head) Register
|
||||
DC = Device Control Register
|
||||
ER = Error register
|
||||
ST = Status register
|
||||
Powered_Up_Time is measured from power on, and printed as
|
||||
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
||||
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
||||
|
||||
Error 1 [0] occurred at disk power-on lifetime: 15257 hours (635 days + 17 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
10 -- 51 00 01 00 00 74 70 6d af 04 00 Error: IDNF at LBA = 0x74706daf = 1953525167
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
24 00 00 00 01 00 00 74 70 6d af 44 00 00:00:00.794 READ SECTOR(S) EXT
|
||||
ef 00 03 00 46 00 00 00 00 00 00 40 00 00:00:00.794 SET FEATURES [Set transfer mode]
|
||||
ef 00 03 00 0c 00 00 00 00 00 00 40 00 00:00:00.794 SET FEATURES [Set transfer mode]
|
||||
ec 00 00 00 00 00 00 00 00 00 00 40 00 00:00:00.791 IDENTIFY DEVICE
|
||||
e5 00 00 00 00 00 00 00 00 00 00 40 00 00:00:00.791 CHECK POWER MODE
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 16714 -
|
||||
# 2 Short offline Completed without error 00% 9464 -
|
||||
# 3 Short offline Interrupted (host reset) 90% 9464 -
|
||||
# 4 Short offline Interrupted (host reset) 90% 9464 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 31 Celsius
|
||||
Power Cycle Min/Max Temperature: 29/31 Celsius
|
||||
Lifetime Min/Max Temperature: 6/49 Celsius
|
||||
Specified Max Operating Temperature: 32 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -40/65 Celsius
|
||||
Temperature History Size (Index): 128 (27)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0009 2 4 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
165
HDD/Apple/HDD HTS5450/HDD HTS545050A7E362/254DAC49FB55
Normal file
165
HDD/Apple/HDD HTS5450/HDD HTS545050A7E362/254DAC49FB55
Normal file
@@ -0,0 +1,165 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.1-RELEASE-p3 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Hitachi/HGST Travelstar Z5K500
|
||||
Device Model: APPLE HDD HTS545050A7E362
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000cca ...
|
||||
Firmware Version: GG2AB990
|
||||
User Capacity: 500,107,862,016 bytes [500 GB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5400 rpm
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s
|
||||
Local Time is: Mon Sep 2 14:54:14 2024 IST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 45) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 108) minutes.
|
||||
SCT capabilities: (0x003d) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate PO-R-- 100 100 062 - 0
|
||||
2 Throughput_Performance P-S--- 100 100 040 - 0
|
||||
3 Spin_Up_Time POS--- 214 214 033 - 1
|
||||
4 Start_Stop_Count -O--C- 100 100 000 - 963
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
|
||||
7 Seek_Error_Rate PO-R-- 100 100 067 - 0
|
||||
8 Seek_Time_Performance P-S--- 100 100 040 - 0
|
||||
9 Power_On_Hours -O--C- 084 084 000 - 7212
|
||||
10 Spin_Retry_Count PO--C- 100 100 060 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 963
|
||||
160 Unknown_Attribute -O--CK 100 100 000 - 0
|
||||
191 G-Sense_Error_Rate -O-R-- 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 12884901999
|
||||
193 Load_Cycle_Count -O--C- 076 076 000 - 245894
|
||||
194 Temperature_Celsius -O---- 176 176 000 - 34 (Min/Max 10/47)
|
||||
195 Hardware_ECC_Recovered -O-R-- 100 100 000 - 0
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O---K 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ---R-- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 0
|
||||
223 Load_Retry_Count -O-R-- 100 100 000 - 0
|
||||
254 Free_Fall_Sensor -O--CK 100 100 000 - 26
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 1 Comprehensive SMART error log
|
||||
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 34 Celsius
|
||||
Power Cycle Min/Max Temperature: 24/41 Celsius
|
||||
Lifetime Min/Max Temperature: 10/47 Celsius
|
||||
Specified Max Operating Temperature: 28 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -40/65 Celsius
|
||||
Temperature History Size (Index): 128 (121)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0009 2 24 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 18 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
168
HDD/Apple/HDD HTS5450/HDD HTS545050A7E362/409B2F8D7F3D
Normal file
168
HDD/Apple/HDD HTS5450/HDD HTS545050A7E362/409B2F8D7F3D
Normal file
@@ -0,0 +1,168 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Hitachi/HGST Travelstar Z5K500
|
||||
Device Model: APPLE HDD HTS545050A7E362
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000cca ...
|
||||
Firmware Version: GG2AB990
|
||||
User Capacity: 500,107,862,016 bytes [500 GB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5400 rpm
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s
|
||||
Local Time is: Tue Dec 19 17:49:46 2023 +03
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 45) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 112) minutes.
|
||||
SCT capabilities: (0x003d) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate PO-R-- 100 100 062 - 0
|
||||
2 Throughput_Performance P-S--- 100 100 040 - 0
|
||||
3 Spin_Up_Time POS--- 253 253 033 - 1
|
||||
4 Start_Stop_Count -O--C- 094 094 000 - 9576
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
|
||||
7 Seek_Error_Rate PO-R-- 100 100 067 - 0
|
||||
8 Seek_Time_Performance P-S--- 100 100 040 - 0
|
||||
9 Power_On_Hours -O--C- 085 085 000 - 6967
|
||||
10 Spin_Retry_Count PO--C- 100 100 060 - 0
|
||||
12 Power_Cycle_Count -O--CK 096 096 000 - 7781
|
||||
160 Unknown_Attribute -O--CK 100 100 000 - 0
|
||||
191 G-Sense_Error_Rate -O-R-- 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 096 096 000 - 2628519985492
|
||||
193 Load_Cycle_Count -O--C- 066 066 000 - 347043
|
||||
194 Temperature_Celsius -O---- 171 171 000 - 35 (Min/Max 12/46)
|
||||
195 Hardware_ECC_Recovered -O-R-- 100 100 000 - 0
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O---K 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ---R-- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 0
|
||||
223 Load_Retry_Count -O-R-- 100 100 000 - 0
|
||||
254 Free_Fall_Sensor -O--CK 073 073 000 - 7118
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 1 Comprehensive SMART error log
|
||||
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 5127 -
|
||||
# 2 Short offline Completed without error 00% 5126 -
|
||||
# 3 Short offline Completed without error 00% 5117 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 35 Celsius
|
||||
Power Cycle Min/Max Temperature: 34/35 Celsius
|
||||
Lifetime Min/Max Temperature: 12/46 Celsius
|
||||
Specified Max Operating Temperature: 33 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -40/65 Celsius
|
||||
Temperature History Size (Index): 128 (104)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0009 2 4 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
165
HDD/Apple/HDD HTS5450/HDD HTS545050A7E362/6A29BB47043C
Normal file
165
HDD/Apple/HDD HTS5450/HDD HTS545050A7E362/6A29BB47043C
Normal file
@@ -0,0 +1,165 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.1-RELEASE-p4 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Hitachi/HGST Travelstar Z5K500
|
||||
Device Model: APPLE HDD HTS545050A7E362
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000cca ...
|
||||
Firmware Version: GG2AB990
|
||||
User Capacity: 500,107,862,016 bytes [500 GB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5400 rpm
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s
|
||||
Local Time is: Mon Sep 16 21:44:16 2024 EDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 45) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 112) minutes.
|
||||
SCT capabilities: (0x003d) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate PO-R-- 100 100 062 - 0
|
||||
2 Throughput_Performance P-S--- 100 100 040 - 0
|
||||
3 Spin_Up_Time POS--- 214 214 033 - 1
|
||||
4 Start_Stop_Count -O--C- 096 096 000 - 6365
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
|
||||
7 Seek_Error_Rate PO-R-- 100 100 067 - 0
|
||||
8 Seek_Time_Performance P-S--- 100 100 040 - 0
|
||||
9 Power_On_Hours -O--C- 030 030 000 - 30843
|
||||
10 Spin_Retry_Count PO--C- 100 100 060 - 0
|
||||
12 Power_Cycle_Count -O--CK 097 097 000 - 5364
|
||||
160 Unknown_Attribute -O--CK 100 100 000 - 0
|
||||
191 G-Sense_Error_Rate -O-R-- 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 4294967430
|
||||
193 Load_Cycle_Count -O--C- 063 063 000 - 377221
|
||||
194 Temperature_Celsius -O---- 187 187 000 - 32 (Min/Max 10/51)
|
||||
195 Hardware_ECC_Recovered -O-R-- 100 100 000 - 0
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O---K 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ---R-- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 0
|
||||
223 Load_Retry_Count -O-R-- 100 100 000 - 0
|
||||
254 Free_Fall_Sensor -O--CK 100 100 000 - 74
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 1 Comprehensive SMART error log
|
||||
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 32 Celsius
|
||||
Power Cycle Min/Max Temperature: 20/39 Celsius
|
||||
Lifetime Min/Max Temperature: 10/51 Celsius
|
||||
Specified Max Operating Temperature: 33 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -40/65 Celsius
|
||||
Temperature History Size (Index): 128 (95)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0009 2 4 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
165
HDD/Apple/HDD HTS5450/HDD HTS545050A7E362/7EBF71F9D0D2
Normal file
165
HDD/Apple/HDD HTS5450/HDD HTS545050A7E362/7EBF71F9D0D2
Normal file
@@ -0,0 +1,165 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.0-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Hitachi/HGST Travelstar Z5K500
|
||||
Device Model: APPLE HDD HTS545050A7E362
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000cca ...
|
||||
Firmware Version: GG2AB990
|
||||
User Capacity: 500,107,862,016 bytes [500 GB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5400 rpm
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s
|
||||
Local Time is: Sat Dec 16 17:35:59 2023 CST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 45) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 105) minutes.
|
||||
SCT capabilities: (0x003d) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate PO-R-- 100 100 062 - 0
|
||||
2 Throughput_Performance P-S--- 100 100 040 - 0
|
||||
3 Spin_Up_Time POS--- 200 200 033 - 1
|
||||
4 Start_Stop_Count -O--C- 089 089 000 - 17809
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
|
||||
7 Seek_Error_Rate PO-R-- 100 100 067 - 0
|
||||
8 Seek_Time_Performance P-S--- 100 100 040 - 0
|
||||
9 Power_On_Hours -O--C- 077 077 000 - 10245
|
||||
10 Spin_Retry_Count PO--C- 100 100 060 - 0
|
||||
12 Power_Cycle_Count -O--CK 089 089 000 - 17690
|
||||
160 Unknown_Attribute -O--CK 100 100 000 - 0
|
||||
191 G-Sense_Error_Rate -O-R-- 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 094 094 000 - 180388627641
|
||||
193 Load_Cycle_Count -O--C- 085 085 000 - 152004
|
||||
194 Temperature_Celsius -O---- 222 222 000 - 27 (Min/Max 13/45)
|
||||
195 Hardware_ECC_Recovered -O-R-- 100 100 000 - 0
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O---K 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ---R-- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 0
|
||||
223 Load_Retry_Count -O-R-- 100 100 000 - 0
|
||||
254 Free_Fall_Sensor -O--CK 100 100 000 - 14
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 1 Comprehensive SMART error log
|
||||
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 28 Celsius
|
||||
Power Cycle Min/Max Temperature: 19/28 Celsius
|
||||
Lifetime Min/Max Temperature: 13/45 Celsius
|
||||
Specified Max Operating Temperature: 32 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -40/65 Celsius
|
||||
Temperature History Size (Index): 128 (110)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0009 2 4 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
247
HDD/Apple/HDD HTS5475/HDD HTS547550A9E384/604D7BF2026D
Normal file
247
HDD/Apple/HDD HTS5475/HDD HTS547550A9E384/604D7BF2026D
Normal file
@@ -0,0 +1,247 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.2-RELEASE-p2 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Hitachi/HGST Travelstar 5K750
|
||||
Device Model: APPLE HDD HTS547550A9E384
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000cca ...
|
||||
Firmware Version: JE3AD70F
|
||||
User Capacity: 500,107,862,016 bytes [500 GB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5400 rpm
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s
|
||||
Local Time is: Wed Sep 6 23:28:14 2023 CET
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 45) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 132) minutes.
|
||||
SCT capabilities: (0x003d) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate PO-R-- 100 100 062 - 0
|
||||
2 Throughput_Performance P-S--- 100 100 040 - 0
|
||||
3 Spin_Up_Time POS--- 166 166 033 - 1
|
||||
4 Start_Stop_Count -O--C- 095 095 000 - 7910
|
||||
5 Reallocated_Sector_Ct PO--CK 072 072 005 - 696
|
||||
7 Seek_Error_Rate PO-R-- 100 100 067 - 0
|
||||
8 Seek_Time_Performance P-S--- 100 100 040 - 0
|
||||
9 Power_On_Hours -O--C- 087 087 000 - 6128
|
||||
10 Spin_Retry_Count PO--C- 100 100 060 - 0
|
||||
12 Power_Cycle_Count -O--CK 096 096 000 - 7151
|
||||
160 Unknown_Attribute -O--CK 100 100 000 - 0
|
||||
191 G-Sense_Error_Rate -O-R-- 095 095 000 - 393221
|
||||
192 Power-Off_Retract_Count -O--CK 094 094 000 - 4788888535205
|
||||
193 Load_Cycle_Count -O--C- 068 068 000 - 320863
|
||||
194 Temperature_Celsius -O---- 166 166 000 - 36 (Min/Max 12/49)
|
||||
195 Hardware_ECC_Recovered -O-R-- 080 080 000 - 5242928
|
||||
196 Reallocated_Event_Count -O--CK 078 078 000 - 696
|
||||
197 Current_Pending_Sector -O---K 057 057 000 - 1208
|
||||
198 Offline_Uncorrectable ---R-- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 5561
|
||||
223 Load_Retry_Count -O-R-- 100 100 000 - 0
|
||||
254 Free_Fall_Sensor -O--CK 046 046 000 - 14063
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 1 Comprehensive SMART error log
|
||||
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
Device Error Count: 6468 (device log contains only the most recent 4 errors)
|
||||
CR = Command Register
|
||||
FEATR = Features Register
|
||||
COUNT = Count (was: Sector Count) Register
|
||||
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
|
||||
LH = LBA High (was: Cylinder High) Register ] LBA
|
||||
LM = LBA Mid (was: Cylinder Low) Register ] Register
|
||||
LL = LBA Low (was: Sector Number) Register ]
|
||||
DV = Device (was: Device/Head) Register
|
||||
DC = Device Control Register
|
||||
ER = Error register
|
||||
ST = Status register
|
||||
Powered_Up_Time is measured from power on, and printed as
|
||||
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
||||
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
||||
|
||||
Error 6468 [3] occurred at disk power-on lifetime: 6108 hours (254 days + 12 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 a0 00 00 1b 73 9e 38 0b 00 Error: UNC at LBA = 0x1b739e38 = 460561976
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 08 00 a8 00 00 20 c9 a7 98 40 00 01:11:49.913 READ FPDMA QUEUED
|
||||
60 00 a8 00 18 00 00 1b 73 9e 30 40 00 01:11:49.897 READ FPDMA QUEUED
|
||||
60 00 c0 00 a0 00 00 20 c8 37 48 40 00 01:11:49.897 READ FPDMA QUEUED
|
||||
60 00 08 00 98 00 00 20 c8 37 40 40 00 01:11:49.897 READ FPDMA QUEUED
|
||||
60 00 40 00 90 00 00 20 c8 37 00 40 00 01:11:49.897 READ FPDMA QUEUED
|
||||
|
||||
Error 6467 [2] occurred at disk power-on lifetime: 6106 hours (254 days + 10 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 08 00 00 1b 6c 4c 88 0b 00 Error: WP at LBA = 0x1b6c4c88 = 460082312
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
61 00 18 00 b8 00 00 02 4c 7c c0 40 00 00:31:38.975 WRITE FPDMA QUEUED
|
||||
60 00 08 00 08 00 00 1b 6c 4c 88 40 00 00:31:36.989 READ FPDMA QUEUED
|
||||
ef 00 10 00 03 00 00 00 00 00 00 a0 00 00:31:36.988 SET FEATURES [Enable SATA feature]
|
||||
ef 00 10 00 02 00 00 00 00 00 00 a0 00 00:31:36.988 SET FEATURES [Enable SATA feature]
|
||||
27 00 00 00 00 00 00 00 00 00 00 e0 00 00:31:36.988 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
|
||||
|
||||
Error 6466 [1] occurred at disk power-on lifetime: 6106 hours (254 days + 10 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 08 00 00 1b 6c 4c 88 0b 00 Error: UNC at LBA = 0x1b6c4c88 = 460082312
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 08 00 f8 00 00 1b 6c 4c 88 40 00 00:31:33.673 READ FPDMA QUEUED
|
||||
60 00 08 00 b8 00 00 1b 6c 4c 80 40 00 00:31:33.673 READ FPDMA QUEUED
|
||||
60 00 08 00 b0 00 00 1b 6c 4c 78 40 00 00:31:33.673 READ FPDMA QUEUED
|
||||
60 00 08 00 a8 00 00 1b 6c 4c 70 40 00 00:31:33.673 READ FPDMA QUEUED
|
||||
60 00 08 00 a0 00 00 1b 6c 4c 68 40 00 00:31:33.672 READ FPDMA QUEUED
|
||||
|
||||
Error 6465 [0] occurred at disk power-on lifetime: 6106 hours (254 days + 10 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 08 00 00 1b 6c 45 d8 0b 00 Error: WP at LBA = 0x1b6c45d8 = 460080600
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
61 00 18 00 28 00 00 02 4c 7c a0 40 00 00:31:32.063 WRITE FPDMA QUEUED
|
||||
60 00 08 00 c0 00 00 1b 6c 45 d8 40 00 00:31:30.286 READ FPDMA QUEUED
|
||||
ef 00 10 00 03 00 00 00 00 00 00 a0 00 00:31:30.285 SET FEATURES [Enable SATA feature]
|
||||
ef 00 10 00 02 00 00 00 00 00 00 a0 00 00:31:30.285 SET FEATURES [Enable SATA feature]
|
||||
27 00 00 00 00 00 00 00 00 00 00 e0 00 00:31:30.285 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 36 Celsius
|
||||
Power Cycle Min/Max Temperature: 35/36 Celsius
|
||||
Lifetime Min/Max Temperature: 12/49 Celsius
|
||||
Specified Max Operating Temperature: 33 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -40/65 Celsius
|
||||
Temperature History Size (Index): 128 (126)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0009 2 7 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 6 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
178
HDD/Apple/HDD HTS5475/HDD HTS547550A9E384/C000E6E8D072
Normal file
178
HDD/Apple/HDD HTS5475/HDD HTS547550A9E384/C000E6E8D072
Normal file
@@ -0,0 +1,178 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.2-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Hitachi/HGST Travelstar 5K750
|
||||
Device Model: APPLE HDD HTS547550A9E384
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000cca ...
|
||||
Firmware Version: JE3AD70F
|
||||
User Capacity: 500,107,862,016 bytes [500 GB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 5400 rpm
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s
|
||||
Local Time is: Fri Jun 16 17:20:07 2023 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 45) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 129) minutes.
|
||||
SCT capabilities: (0x003d) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate PO-R-- 100 100 062 - 0
|
||||
2 Throughput_Performance P-S--- 100 100 040 - 0
|
||||
3 Spin_Up_Time POS--- 253 253 033 - 1
|
||||
4 Start_Stop_Count -O--C- 095 095 000 - 9417
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
|
||||
7 Seek_Error_Rate PO-R-- 100 100 067 - 0
|
||||
8 Seek_Time_Performance P-S--- 100 100 040 - 0
|
||||
9 Power_On_Hours -O--C- 076 076 000 - 10573
|
||||
10 Spin_Retry_Count PO--C- 100 100 060 - 0
|
||||
12 Power_Cycle_Count -O--CK 095 095 000 - 8922
|
||||
160 Unknown_Attribute -O--CK 100 100 000 - 0
|
||||
191 G-Sense_Error_Rate -O-R-- 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 097 097 000 - 2791728873577
|
||||
193 Load_Cycle_Count -O--C- 020 020 000 - 801869
|
||||
194 Temperature_Celsius -O---- 206 206 000 - 29 (Min/Max 8/47)
|
||||
195 Hardware_ECC_Recovered -O-R-- 080 080 000 - 5767200
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O---K 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ---R-- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 0
|
||||
223 Load_Retry_Count -O-R-- 100 100 000 - 0
|
||||
254 Free_Fall_Sensor -O--CK 037 037 000 - 4294983565
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 1 Comprehensive SMART error log
|
||||
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 10552 -
|
||||
# 2 Extended offline Completed without error 00% 10544 -
|
||||
# 3 Extended offline Interrupted (host reset) 90% 10530 -
|
||||
# 4 Short offline Aborted by host 90% 10527 -
|
||||
# 5 Extended offline Interrupted (host reset) 30% 10524 -
|
||||
# 6 Extended offline Interrupted (host reset) 90% 10515 -
|
||||
# 7 Short offline Completed without error 00% 10510 -
|
||||
# 8 Short offline Completed without error 00% 10509 -
|
||||
# 9 Short offline Completed without error 00% 10488 -
|
||||
#10 Short offline Completed without error 00% 10464 -
|
||||
#11 Short offline Completed without error 00% 10458 -
|
||||
#12 Short offline Completed without error 00% 10453 -
|
||||
#13 Extended offline Interrupted (host reset) 70% 10453 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 29 Celsius
|
||||
Power Cycle Min/Max Temperature: 26/29 Celsius
|
||||
Lifetime Min/Max Temperature: 8/47 Celsius
|
||||
Specified Max Operating Temperature: 31 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -40/65 Celsius
|
||||
Temperature History Size (Index): 128 (8)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0009 2 3 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
176
HDD/Apple/HDD ST1000/HDD ST1000DM003/F51E6FB6C982
Normal file
176
HDD/Apple/HDD ST1000/HDD ST1000DM003/F51E6FB6C982
Normal file
@@ -0,0 +1,176 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.0-BETA1 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Device Model: APPLE HDD ST1000DM003
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000c50 ...
|
||||
Firmware Version: AQ03
|
||||
User Capacity: 1,000,204,886,016 bytes [1.00 TB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 3.5 inches
|
||||
Device is: Not in smartctl database 7.3/5528
|
||||
ATA Version is: ACS-2, ACS-3 T13/2161-D revision 3b
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Tue Sep 12 23:07:20 2023 EDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 192 (intermediate level without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 80) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x73) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 104) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
SCT capabilities: (0x10bd) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 10
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 118 099 006 - 170847048
|
||||
3 Spin_Up_Time PO---- 097 097 000 - 0
|
||||
4 Start_Stop_Count -O--CK 098 098 020 - 2932
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
|
||||
7 Seek_Error_Rate POSR-- 089 060 030 - 839086266
|
||||
9 Power_On_Hours -O--CK 054 054 000 - 40460
|
||||
10 Spin_Retry_Count PO--C- 100 100 097 - 0
|
||||
12 Power_Cycle_Count -O--CK 097 097 020 - 3099
|
||||
184 End-to-End_Error -O--CK 100 100 099 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
188 Command_Timeout -O--CK 100 099 000 - 2
|
||||
189 High_Fly_Writes -O-RCK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 065 052 045 - 35 (Min/Max 35/35)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 177
|
||||
193 Load_Cycle_Count -O--CK 099 099 000 - 3311
|
||||
194 Temperature_Celsius -O---K 035 048 000 - 35 (0 14 0 0 0)
|
||||
197 Current_Pending_Sector -O--C- 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----C- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
240 Head_Flying_Hours ------ 100 253 000 - 40563 (93 164 0)
|
||||
241 Total_LBAs_Written ------ 100 253 000 - 56391494198
|
||||
242 Total_LBAs_Read ------ 100 253 000 - 75657810093587
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x21 GPL R/O 1 Write stream error log
|
||||
0x22 GPL R/O 1 Read stream error log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa1 GPL,SL VS 132 Device vendor specific log
|
||||
0xa2 GPL VS 4496 Device vendor specific log
|
||||
0xa5 GPL,SL VS 132 Device vendor specific log
|
||||
0xa8 GPL,SL VS 129 Device vendor specific log
|
||||
0xa9 GPL,SL VS 1 Device vendor specific log
|
||||
0xab GPL VS 1 Device vendor specific log
|
||||
0xb0 GPL VS 5288 Device vendor specific log
|
||||
0xbe-0xbf GPL VS 65535 Device vendor specific log
|
||||
0xc1 GPL,SL VS 10 Device vendor specific log
|
||||
0xc4 GPL,SL VS 5 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 522 (0x020a)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 35 Celsius
|
||||
Power Cycle Min/Max Temperature: 35/35 Celsius
|
||||
Lifetime Min/Max Temperature: 14/48 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 59 minutes
|
||||
Min/Max recommended Temperature: 3/62 Celsius
|
||||
Min/Max Temperature Limit: 0/65 Celsius
|
||||
Temperature History Size (Index): 128 (92)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x000a 2 14 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
|
||||
|
||||
|
182
HDD/Apple/HDD WDC WD10/HDD WDC WD10EALX-408EA0/AAD89C854E24
Normal file
182
HDD/Apple/HDD WDC WD10/HDD WDC WD10EALX-408EA0/AAD89C854E24
Normal file
@@ -0,0 +1,182 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.2-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Western Digital Blue
|
||||
Device Model: APPLE HDD WDC WD10EALX-408EA0
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 0014ee ...
|
||||
Firmware Version: 07.01D03
|
||||
User Capacity: 1,000,204,886,016 bytes [1.00 TB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sun Jul 28 13:07:47 2024 EDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: (16200) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 187) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 5) minutes.
|
||||
SCT capabilities: (0xb037) SCT Status supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 177 171 021 - 4133
|
||||
4 Start_Stop_Count -O--CK 086 086 000 - 14813
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 040 040 000 - 43892
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 086 086 000 - 14807
|
||||
192 Power-Off_Retract_Count -O--CK 181 181 000 - 14285
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 527
|
||||
194 Temperature_Celsius -O---K 112 093 000 - 35
|
||||
195 Hardware_ECC_Recovered -OS-CK 200 200 000 - 0
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate ---R-- 200 200 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 6 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
|
||||
0xa8-0xb4 GPL,SL VS 1 Device vendor specific log
|
||||
0xb5 GPL,SL VS 128 Device vendor specific log
|
||||
0xb6 GPL VS 1 Device vendor specific log
|
||||
0xb7 GPL,SL VS 1 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xc1 GPL VS 24 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Aborted by host 90% 43859 -
|
||||
# 2 Short offline Aborted by host 90% 43853 -
|
||||
# 3 Short offline Aborted by host 90% 43847 -
|
||||
# 4 Short offline Aborted by host 90% 43839 -
|
||||
# 5 Short offline Aborted by host 90% 43839 -
|
||||
# 6 Short offline Aborted by host 90% 43826 -
|
||||
# 7 Short offline Aborted by host 90% 43818 -
|
||||
# 8 Short offline Aborted by host 90% 43815 -
|
||||
# 9 Short offline Aborted by host 90% 43815 -
|
||||
#10 Short offline Aborted by host 90% 43815 -
|
||||
#11 Short offline Aborted by host 90% 43814 -
|
||||
#12 Short offline Aborted by host 90% 43814 -
|
||||
#13 Short offline Aborted by host 90% 43814 -
|
||||
#14 Short offline Aborted by host 90% 43712 -
|
||||
#15 Short offline Aborted by host 90% 43609 -
|
||||
#16 Short offline Aborted by host 90% 43450 -
|
||||
#17 Short offline Aborted by host 90% 43241 -
|
||||
#18 Short offline Aborted by host 90% 42778 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 35 Celsius
|
||||
Power Cycle Min/Max Temperature: 31/35 Celsius
|
||||
Lifetime Min/Max Temperature: 26/54 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (387)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000a 2 0 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x8000 4 2154 Vendor specific
|
||||
|