mirror of
https://github.com/bsdhw/SMART.git
synced 2025-05-31 16:21:41 +05:30
Update of reports (new: 6895, modified: 16)
This commit is contained in:
173
HDD/HGST/HTS7250/HTS725032A7E630/83AE988AE175
Normal file
173
HDD/HGST/HTS7250/HTS725032A7E630/83AE988AE175
Normal file
@@ -0,0 +1,173 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Hitachi/HGST Travelstar Z7K500
|
||||
Device Model: HGST HTS725032A7E630
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000cca ...
|
||||
Firmware Version: GHBOA560
|
||||
User Capacity: 320,072,933,376 bytes [320 GB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 2.6, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Tue Mar 12 08:35:55 2024 UTC
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 45) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 67) minutes.
|
||||
SCT capabilities: (0x003d) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate PO-R-- 100 100 062 - 0
|
||||
2 Throughput_Performance --S--- 198 198 000 - 110
|
||||
3 Spin_Up_Time POS--- 217 217 033 - 1
|
||||
4 Start_Stop_Count -O--C- 095 095 000 - 9391
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
|
||||
7 Seek_Error_Rate -O-R-- 100 100 000 - 0
|
||||
8 Seek_Time_Performance --S--- 115 115 000 - 34
|
||||
9 Power_On_Hours -O--C- 060 060 000 - 17725
|
||||
10 Spin_Retry_Count -O--C- 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 098 098 000 - 3638
|
||||
191 G-Sense_Error_Rate -O-R-- 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 150
|
||||
193 Load_Cycle_Count -O--C- 085 085 000 - 155438
|
||||
194 Temperature_Celsius -O---- 230 230 000 - 26 (Min/Max 14/56)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O---K 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ---R-- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 0
|
||||
223 Load_Retry_Count -O-R-- 100 100 000 - 0
|
||||
240 Head_Flying_Hours -O--CK 090 090 000 - 4577
|
||||
241 Total_LBAs_Written -O--CK 099 099 000 - 71550314174
|
||||
242 Total_LBAs_Read -O--CK 100 100 000 - 44159944577
|
||||
254 Free_Fall_Sensor -O--CK 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 1 Comprehensive SMART error log
|
||||
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 2063 -
|
||||
# 2 Short offline Completed without error 00% 2063 -
|
||||
# 3 Extended offline Interrupted (host reset) 90% 1867 -
|
||||
# 4 Short offline Completed without error 00% 1864 -
|
||||
# 5 Short offline Completed without error 00% 0 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 26 Celsius
|
||||
Power Cycle Min/Max Temperature: 19/30 Celsius
|
||||
Lifetime Min/Max Temperature: 14/56 Celsius
|
||||
Specified Max Operating Temperature: 30 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -40/65 Celsius
|
||||
Temperature History Size (Index): 128 (44)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0009 2 21 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 22 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
||||
|
||||
|
246
HDD/HGST/HTS7250/HTS725032A7E630/E61C093D48DE
Normal file
246
HDD/HGST/HTS7250/HTS725032A7E630/E61C093D48DE
Normal file
@@ -0,0 +1,246 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p8 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Hitachi/HGST Travelstar Z7K500
|
||||
Device Model: HGST HTS725032A7E630
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000cca ...
|
||||
Firmware Version: GHBZB550
|
||||
User Capacity: 320,072,933,376 bytes [320 GB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 2.6, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sun Oct 22 10:39:18 2023 CDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 45) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 69) minutes.
|
||||
SCT capabilities: (0x003d) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate PO-R-- 100 100 062 - 0
|
||||
2 Throughput_Performance P-S--- 100 100 040 - 0
|
||||
3 Spin_Up_Time POS--- 229 229 033 - 1
|
||||
4 Start_Stop_Count -O--C- 100 100 000 - 1455
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
|
||||
7 Seek_Error_Rate PO-R-- 100 100 067 - 0
|
||||
8 Seek_Time_Performance P-S--- 100 100 040 - 0
|
||||
9 Power_On_Hours -O--C- 052 052 000 - 21209
|
||||
10 Spin_Retry_Count PO--C- 100 100 060 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 1366
|
||||
191 G-Sense_Error_Rate -O-R-- 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 196729
|
||||
193 Load_Cycle_Count -O--C- 017 017 000 - 833321
|
||||
194 Temperature_Celsius -O---- 200 200 000 - 30 (Min/Max 12/49)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 1
|
||||
197 Current_Pending_Sector -O---K 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ---R-- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 1733
|
||||
223 Load_Retry_Count -O-R-- 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 1 Comprehensive SMART error log
|
||||
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
Device Error Count: 1740 (device log contains only the most recent 4 errors)
|
||||
CR = Command Register
|
||||
FEATR = Features Register
|
||||
COUNT = Count (was: Sector Count) Register
|
||||
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
|
||||
LH = LBA High (was: Cylinder High) Register ] LBA
|
||||
LM = LBA Mid (was: Cylinder Low) Register ] Register
|
||||
LL = LBA Low (was: Sector Number) Register ]
|
||||
DV = Device (was: Device/Head) Register
|
||||
DC = Device Control Register
|
||||
ER = Error register
|
||||
ST = Status register
|
||||
Powered_Up_Time is measured from power on, and printed as
|
||||
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
||||
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
||||
|
||||
Error 1740 [3] occurred at disk power-on lifetime: 14855 hours (618 days + 23 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
84 -- 51 00 00 00 00 00 00 00 00 00 00
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
ec 00 00 00 00 00 00 00 00 00 00 40 00 5d+01:00:20.184 IDENTIFY DEVICE
|
||||
60 00 19 00 0a 00 00 07 3e 39 1a 07 ff 5d+01:00:20.171 READ FPDMA QUEUED
|
||||
60 00 19 00 a0 00 00 07 3e 39 0b 40 00 5d+01:00:20.155 READ FPDMA QUEUED
|
||||
60 00 08 00 98 00 00 0d 22 a8 a0 40 00 5d+01:00:20.119 READ FPDMA QUEUED
|
||||
60 00 40 00 90 00 00 0d 22 6d 98 40 00 5d+01:00:20.109 READ FPDMA QUEUED
|
||||
|
||||
Error 1739 [2] occurred at disk power-on lifetime: 14855 hours (618 days + 23 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
84 -- 51 00 0a 00 00 07 3e 39 1a 07 00 Error: ICRC, ABRT at LBA = 0x073e391a = 121518362
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 19 00 a0 00 00 07 3e 39 0b 40 00 5d+01:00:20.155 READ FPDMA QUEUED
|
||||
60 00 08 00 98 00 00 0d 22 a8 a0 40 00 5d+01:00:20.119 READ FPDMA QUEUED
|
||||
60 00 40 00 90 00 00 0d 22 6d 98 40 00 5d+01:00:20.109 READ FPDMA QUEUED
|
||||
60 00 10 00 88 00 00 0d 22 6d 48 40 00 5d+01:00:20.105 READ FPDMA QUEUED
|
||||
60 00 20 00 80 00 00 0d 22 6d 20 40 00 5d+01:00:20.104 READ FPDMA QUEUED
|
||||
|
||||
Error 1738 [1] occurred at disk power-on lifetime: 14855 hours (618 days + 23 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
84 -- 51 00 11 00 00 0d 22 ab 37 0d 00 Error: ICRC, ABRT at LBA = 0x0d22ab37 = 220375863
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 05 00 50 00 00 07 3e 39 24 40 00 5d+01:00:19.996 READ FPDMA QUEUED
|
||||
60 00 20 00 48 00 00 0d 22 ab 28 40 00 5d+01:00:19.996 READ FPDMA QUEUED
|
||||
61 00 08 00 40 00 00 00 06 4f 10 40 00 5d+01:00:19.982 WRITE FPDMA QUEUED
|
||||
60 00 08 00 38 00 00 07 3e 32 40 40 00 5d+01:00:19.979 READ FPDMA QUEUED
|
||||
60 00 10 00 30 00 00 0d 22 a5 58 40 00 5d+01:00:19.975 READ FPDMA QUEUED
|
||||
|
||||
Error 1737 [0] occurred at disk power-on lifetime: 14734 hours (613 days + 22 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
84 -- 51 00 11 00 00 00 27 2c 4d 00 00 Error: ICRC, ABRT at LBA = 0x00272c4d = 2567245
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 08 00 08 00 00 09 a4 16 50 40 00 00:02:43.769 READ FPDMA QUEUED
|
||||
60 00 08 00 00 00 00 09 a4 2b c8 40 00 00:02:43.768 READ FPDMA QUEUED
|
||||
61 00 40 00 f8 00 00 09 ea 67 00 40 00 00:02:43.762 WRITE FPDMA QUEUED
|
||||
61 00 40 00 f0 00 00 09 ea 66 c0 40 00 00:02:43.762 WRITE FPDMA QUEUED
|
||||
60 00 20 00 e8 00 00 00 27 2c 3e 40 00 00:02:43.756 READ FPDMA QUEUED
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Vendor (0x50) Completed without error 00% 8 -
|
||||
# 2 Short offline Completed without error 00% 8 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 30 Celsius
|
||||
Power Cycle Min/Max Temperature: 19/37 Celsius
|
||||
Lifetime Min/Max Temperature: 12/49 Celsius
|
||||
Specified Max Operating Temperature: 31 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -40/65 Celsius
|
||||
Temperature History Size (Index): 128 (67)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0009 2 14 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 14 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
167
HDD/HGST/HTS7250/HTS725050A7E630/14BB4970DF79
Normal file
167
HDD/HGST/HTS7250/HTS725050A7E630/14BB4970DF79
Normal file
@@ -0,0 +1,167 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.2-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Hitachi/HGST Travelstar Z7K500
|
||||
Device Model: HGST HTS725050A7E630
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000cca ...
|
||||
Firmware Version: GH2OA440
|
||||
User Capacity: 500,107,862,016 bytes [500 GB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 3.0, 3.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Mon May 22 23:23:17 2023 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 45) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x51) SMART execute Offline immediate.
|
||||
No Auto Offline data collection support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 92) minutes.
|
||||
SCT capabilities: (0x003d) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 062 - 0
|
||||
2 Throughput_Performance P-S--K 100 100 040 - 0
|
||||
3 Spin_Up_Time PO---K 245 100 033 - 1
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 152
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
|
||||
7 Seek_Error_Rate POSR-K 100 100 067 - 0
|
||||
8 Seek_Time_Performance P-S--K 100 100 040 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 233
|
||||
10 Spin_Retry_Count PO--CK 100 100 060 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 152
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error PO--CK 100 100 097 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 8590393344
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 069 057 045 - 31 (Min/Max 25/37)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 55
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 1048592
|
||||
193 Load_Cycle_Count -O--CK 100 100 000 - 6161
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OS-CK 100 100 000 - 0
|
||||
223 Load_Retry_Count -O-R-K 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 1 Comprehensive SMART error log
|
||||
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 5 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 31 Celsius
|
||||
Power Cycle Min/Max Temperature: 25/37 Celsius
|
||||
Lifetime Min/Max Temperature: -1/43 Celsius
|
||||
Specified Max Operating Temperature: 32 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -40/65 Celsius
|
||||
Temperature History Size (Index): 128 (18)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 85 (8.5 seconds)
|
||||
Write: 85 (8.5 seconds)
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0009 2 63 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 62 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
168
HDD/HGST/HTS7250/HTS725050A7E630/5427D119476F
Normal file
168
HDD/HGST/HTS7250/HTS725050A7E630/5427D119476F
Normal file
@@ -0,0 +1,168 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p8 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Hitachi/HGST Travelstar Z7K500
|
||||
Device Model: HGST HTS725050A7E630
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000cca ...
|
||||
Firmware Version: GS2OA3C0
|
||||
User Capacity: 500,107,862,016 bytes [500 GB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Thu Nov 23 20:09:33 2023 CET
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
See vendor-specific Attribute list for marginal Attributes.
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x85) Offline data collection activity
|
||||
was aborted by an interrupting command from host.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 5075) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 86) minutes.
|
||||
SCT capabilities: (0x003d) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 062 - 0
|
||||
2 Throughput_Performance P-S--K 198 100 040 - 99
|
||||
3 Spin_Up_Time PO---K 223 100 033 - 1
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 1089
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
|
||||
7 Seek_Error_Rate POSR-K 100 100 067 - 0
|
||||
8 Seek_Time_Performance P-S--K 157 100 040 - 30
|
||||
9 Power_On_Hours -O--CK 080 080 000 - 8761
|
||||
10 Spin_Retry_Count PO--CK 100 100 060 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 1087
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error PO--CK 100 100 097 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 73014444032
|
||||
188 Command_Timeout -O--CK 100 100 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 045 045 045 NOW 55 (Min/Max 25/55)
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 147
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 4128831
|
||||
193 Load_Cycle_Count -O--CK 097 097 000 - 33412
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OS-CK 100 100 000 - 0
|
||||
223 Load_Retry_Count -O-R-K 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 1 Comprehensive SMART error log
|
||||
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 1 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 55 Celsius
|
||||
Power Cycle Min/Max Temperature: 25/55 Celsius
|
||||
Lifetime Min/Max Temperature: 9/55 Celsius
|
||||
Specified Max Operating Temperature: 31 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -40/65 Celsius
|
||||
Temperature History Size (Index): 128 (18)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 85 (8.5 seconds)
|
||||
Write: 85 (8.5 seconds)
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0009 2 6 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 5 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
163
HDD/HGST/HTS7250/HTS725050A7E630/56EF443644A4
Normal file
163
HDD/HGST/HTS7250/HTS725050A7E630/56EF443644A4
Normal file
@@ -0,0 +1,163 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.2-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Hitachi/HGST Travelstar Z7K500
|
||||
Device Model: HGST HTS725050A7E630
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000cca ...
|
||||
Firmware Version: GH2ZB550
|
||||
User Capacity: 500,107,862,016 bytes [500 GB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 2.6, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Wed May 24 23:44:28 2023 +07
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 45) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 91) minutes.
|
||||
SCT capabilities: (0x003d) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate PO-R-- 100 100 062 - 0
|
||||
2 Throughput_Performance P-S--- 100 100 040 - 0
|
||||
3 Spin_Up_Time POS--- 239 239 033 - 1
|
||||
4 Start_Stop_Count -O--C- 100 100 000 - 110
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
|
||||
7 Seek_Error_Rate PO-R-- 100 100 067 - 0
|
||||
8 Seek_Time_Performance P-S--- 100 100 040 - 0
|
||||
9 Power_On_Hours -O--C- 100 100 000 - 107
|
||||
10 Spin_Retry_Count PO--C- 100 100 060 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 107
|
||||
191 G-Sense_Error_Rate -O-R-- 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 20
|
||||
193 Load_Cycle_Count -O--C- 099 099 000 - 13411
|
||||
194 Temperature_Celsius -O---- 153 153 000 - 39 (Min/Max 21/47)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O---K 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ---R-- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 0
|
||||
223 Load_Retry_Count -O-R-- 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 1 Comprehensive SMART error log
|
||||
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Vendor (0x50) Completed without error 00% 0 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 39 Celsius
|
||||
Power Cycle Min/Max Temperature: 31/40 Celsius
|
||||
Lifetime Min/Max Temperature: 21/47 Celsius
|
||||
Specified Max Operating Temperature: 39 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -40/65 Celsius
|
||||
Temperature History Size (Index): 128 (111)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0009 2 2 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 1 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
166
HDD/HGST/HTS7250/HTS725050A7E630/6D80971614BE
Normal file
166
HDD/HGST/HTS7250/HTS725050A7E630/6D80971614BE
Normal file
@@ -0,0 +1,166 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Hitachi/HGST Travelstar Z7K500
|
||||
Device Model: HGST HTS725050A7E630
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000cca ...
|
||||
Firmware Version: GS2OA3C0
|
||||
User Capacity: 500,107,862,016 bytes [500 GB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Tue Mar 12 12:35:43 2024 UTC
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x84) Offline data collection activity
|
||||
was suspended by an interrupting command from host.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 5235) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 89) minutes.
|
||||
SCT capabilities: (0x003d) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 062 - 0
|
||||
2 Throughput_Performance P-S--K 198 100 040 - 99
|
||||
3 Spin_Up_Time PO---K 222 100 033 - 1
|
||||
4 Start_Stop_Count -O--CK 095 095 000 - 8466
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
|
||||
7 Seek_Error_Rate POSR-K 100 100 067 - 0
|
||||
8 Seek_Time_Performance P-S--K 157 100 040 - 30
|
||||
9 Power_On_Hours -O--CK 022 022 000 - 34588
|
||||
10 Spin_Retry_Count PO--CK 100 100 060 - 0
|
||||
12 Power_Cycle_Count -O--CK 095 095 000 - 8461
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error PO--CK 100 100 097 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 73014509568
|
||||
188 Command_Timeout -O--CK 100 100 000 - 1
|
||||
190 Airflow_Temperature_Cel -O---K 061 053 045 - 39 (Min/Max 22/40)
|
||||
191 G-Sense_Error_Rate -O--CK 099 099 000 - 381
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 12583104
|
||||
193 Load_Cycle_Count -O--CK 001 001 000 - 2143000
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OS-CK 100 100 000 - 0
|
||||
223 Load_Retry_Count -O-R-K 100 092 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 1 Comprehensive SMART error log
|
||||
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: SMART Off-line Data Collection executing in background (4)
|
||||
Current Temperature: 39 Celsius
|
||||
Power Cycle Min/Max Temperature: 22/40 Celsius
|
||||
Lifetime Min/Max Temperature: 12/47 Celsius
|
||||
Specified Max Operating Temperature: 34 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -40/65 Celsius
|
||||
Temperature History Size (Index): 128 (114)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 85 (8.5 seconds)
|
||||
Write: 85 (8.5 seconds)
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0009 2 2 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
165
HDD/HGST/HTS7250/HTS725050A7E630/AF8AEF5F8616
Normal file
165
HDD/HGST/HTS7250/HTS725050A7E630/AF8AEF5F8616
Normal file
@@ -0,0 +1,165 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.0-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Hitachi/HGST Travelstar Z7K500
|
||||
Device Model: HGST HTS725050A7E630
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000cca ...
|
||||
Firmware Version: GS2OA230
|
||||
User Capacity: 500,107,862,016 bytes [500 GB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 2.6, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sat Dec 30 18:19:12 2023 CST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 45) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 90) minutes.
|
||||
SCT capabilities: (0x003d) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate PO-R-- 100 100 062 - 0
|
||||
2 Throughput_Performance P-S--- 100 100 040 - 0
|
||||
3 Spin_Up_Time POS--- 235 235 033 - 1
|
||||
4 Start_Stop_Count -O--C- 099 099 000 - 2691
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
|
||||
7 Seek_Error_Rate PO-R-- 100 100 067 - 0
|
||||
8 Seek_Time_Performance P-S--- 100 100 040 - 0
|
||||
9 Power_On_Hours -O--C- 077 077 000 - 10382
|
||||
10 Spin_Retry_Count PO--C- 100 100 060 - 0
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 2585
|
||||
191 G-Sense_Error_Rate -O-R-- 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 53
|
||||
193 Load_Cycle_Count -O--C- 082 082 000 - 181445
|
||||
194 Temperature_Celsius -O---- 214 214 000 - 28 (Min/Max 4/56)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O---K 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ---R-- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 0
|
||||
223 Load_Retry_Count -O-R-- 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 1 Comprehensive SMART error log
|
||||
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 10374 -
|
||||
# 2 Short offline Completed without error 00% 10100 -
|
||||
# 3 Short offline Completed without error 00% 9816 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 28 Celsius
|
||||
Power Cycle Min/Max Temperature: 15/28 Celsius
|
||||
Lifetime Min/Max Temperature: 4/56 Celsius
|
||||
Specified Max Operating Temperature: 36 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -40/65 Celsius
|
||||
Temperature History Size (Index): 128 (119)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0009 2 3 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 2 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
244
HDD/HGST/HTS7250/HTS725050A7E630/F7DDC56EDA90
Normal file
244
HDD/HGST/HTS7250/HTS725050A7E630/F7DDC56EDA90
Normal file
@@ -0,0 +1,244 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.0-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Hitachi/HGST Travelstar Z7K500
|
||||
Device Model: HGST HTS725050A7E630
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000cca ...
|
||||
Firmware Version: GH2OA420
|
||||
User Capacity: 500,107,862,016 bytes [500 GB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 2.6, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Tue Apr 23 13:28:44 2024 +05
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 45) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 90) minutes.
|
||||
SCT capabilities: (0x003d) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate PO-R-- 100 100 062 - 0
|
||||
2 Throughput_Performance P-S--- 100 100 040 - 0
|
||||
3 Spin_Up_Time POS--- 238 238 033 - 1
|
||||
4 Start_Stop_Count -O--C- 087 087 000 - 21270
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
|
||||
7 Seek_Error_Rate PO-R-- 100 100 067 - 0
|
||||
8 Seek_Time_Performance P-S--- 100 100 040 - 0
|
||||
9 Power_On_Hours -O--C- 046 046 000 - 23792
|
||||
10 Spin_Retry_Count PO--C- 100 100 060 - 0
|
||||
12 Power_Cycle_Count -O--CK 095 095 000 - 9228
|
||||
191 G-Sense_Error_Rate -O-R-- 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 096 096 000 - 989
|
||||
193 Load_Cycle_Count -O--C- 062 062 000 - 383097
|
||||
194 Temperature_Celsius -O---- 206 206 000 - 29 (Min/Max -5/49)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 107
|
||||
197 Current_Pending_Sector -O---K 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ---R-- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 278
|
||||
223 Load_Retry_Count -O-R-- 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 1 Comprehensive SMART error log
|
||||
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
Device Error Count: 334 (device log contains only the most recent 4 errors)
|
||||
CR = Command Register
|
||||
FEATR = Features Register
|
||||
COUNT = Count (was: Sector Count) Register
|
||||
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
|
||||
LH = LBA High (was: Cylinder High) Register ] LBA
|
||||
LM = LBA Mid (was: Cylinder Low) Register ] Register
|
||||
LL = LBA Low (was: Sector Number) Register ]
|
||||
DV = Device (was: Device/Head) Register
|
||||
DC = Device Control Register
|
||||
ER = Error register
|
||||
ST = Status register
|
||||
Powered_Up_Time is measured from power on, and printed as
|
||||
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
||||
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
||||
|
||||
Error 334 [1] occurred at disk power-on lifetime: 13553 hours (564 days + 17 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 08 00 00 00 69 74 60 00 00 Error: UNC 8 sectors at LBA = 0x00697460 = 6911072
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
25 00 00 00 08 00 00 00 69 74 60 e0 00 01:09:55.304 READ DMA EXT
|
||||
25 00 00 00 08 00 00 00 69 74 60 e0 00 01:09:52.313 READ DMA EXT
|
||||
25 00 00 00 08 00 00 00 69 74 60 e0 00 01:09:49.313 READ DMA EXT
|
||||
25 00 00 00 08 00 00 00 69 74 60 e0 00 01:09:46.331 READ DMA EXT
|
||||
25 00 00 00 10 00 00 00 69 76 60 e0 00 01:09:46.330 READ DMA EXT
|
||||
|
||||
Error 333 [0] occurred at disk power-on lifetime: 13553 hours (564 days + 17 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 08 00 00 00 69 74 60 00 00 Error: UNC 8 sectors at LBA = 0x00697460 = 6911072
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
25 00 00 00 08 00 00 00 69 74 60 e0 00 01:09:52.313 READ DMA EXT
|
||||
25 00 00 00 08 00 00 00 69 74 60 e0 00 01:09:49.313 READ DMA EXT
|
||||
25 00 00 00 08 00 00 00 69 74 60 e0 00 01:09:46.331 READ DMA EXT
|
||||
25 00 00 00 10 00 00 00 69 76 60 e0 00 01:09:46.330 READ DMA EXT
|
||||
25 00 00 01 00 00 00 00 69 75 60 e0 00 01:09:46.312 READ DMA EXT
|
||||
|
||||
Error 332 [3] occurred at disk power-on lifetime: 13553 hours (564 days + 17 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 08 00 00 00 69 74 60 00 00 Error: UNC 8 sectors at LBA = 0x00697460 = 6911072
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
25 00 00 00 08 00 00 00 69 74 60 e0 00 01:09:49.313 READ DMA EXT
|
||||
25 00 00 00 08 00 00 00 69 74 60 e0 00 01:09:46.331 READ DMA EXT
|
||||
25 00 00 00 10 00 00 00 69 76 60 e0 00 01:09:46.330 READ DMA EXT
|
||||
25 00 00 01 00 00 00 00 69 75 60 e0 00 01:09:46.312 READ DMA EXT
|
||||
25 00 00 01 00 00 00 00 69 74 60 e0 00 01:09:43.306 READ DMA EXT
|
||||
|
||||
Error 331 [2] occurred at disk power-on lifetime: 13553 hours (564 days + 17 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 08 00 00 00 69 74 60 00 00 Error: UNC 8 sectors at LBA = 0x00697460 = 6911072
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
25 00 00 00 08 00 00 00 69 74 60 e0 00 01:09:46.331 READ DMA EXT
|
||||
25 00 00 00 10 00 00 00 69 76 60 e0 00 01:09:46.330 READ DMA EXT
|
||||
25 00 00 01 00 00 00 00 69 75 60 e0 00 01:09:46.312 READ DMA EXT
|
||||
25 00 00 01 00 00 00 00 69 74 60 e0 00 01:09:43.306 READ DMA EXT
|
||||
ea 00 00 00 00 5b 93 87 00 00 00 a0 00 01:09:41.283 FLUSH CACHE EXT
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 29 Celsius
|
||||
Power Cycle Min/Max Temperature: 22/30 Celsius
|
||||
Lifetime Min/Max Temperature: -5/49 Celsius
|
||||
Specified Max Operating Temperature: 26 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -40/65 Celsius
|
||||
Temperature History Size (Index): 128 (44)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0009 2 17 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 17 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
180
HDD/HGST/HTS7250/HTS725050A7E635 OPAL/883223F26096
Normal file
180
HDD/HGST/HTS7250/HTS725050A7E635 OPAL/883223F26096
Normal file
@@ -0,0 +1,180 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Device Model: HGST HTS725050A7E635 OPAL
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000cca ...
|
||||
Firmware Version: GS26B840
|
||||
User Capacity: 500,107,862,016 bytes [500 GB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 2.5 inches
|
||||
Device is: Not in smartctl database 7.3/5319
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Sun Aug 20 11:42:11 2023 UTC
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 45) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 99) minutes.
|
||||
SCT capabilities: (0x003d) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate PO-R-- 100 100 062 - 0
|
||||
2 Throughput_Performance P-S--- 100 100 040 - 0
|
||||
3 Spin_Up_Time POS--- 229 229 033 - 1
|
||||
4 Start_Stop_Count -O--C- 093 093 000 - 11177
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
|
||||
7 Seek_Error_Rate PO-R-- 100 100 067 - 0
|
||||
8 Seek_Time_Performance P-S--- 100 100 040 - 0
|
||||
9 Power_On_Hours -O--C- 070 070 000 - 13421
|
||||
10 Spin_Retry_Count PO--C- 100 100 060 - 0
|
||||
12 Power_Cycle_Count -O--CK 097 097 000 - 5124
|
||||
191 G-Sense_Error_Rate -O-R-- 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 099 099 000 - 2932146443
|
||||
193 Load_Cycle_Count -O--C- 071 071 000 - 297184
|
||||
194 Temperature_Celsius -O---- 142 142 000 - 42 (Min/Max 6/55)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 75
|
||||
197 Current_Pending_Sector -O---K 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ---R-- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 0
|
||||
223 Load_Retry_Count -O-R-- 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 1 Comprehensive SMART error log
|
||||
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 13389 -
|
||||
# 2 Vendor (0x50) Completed without error 00% 13024 -
|
||||
# 3 Short offline Completed without error 00% 13024 -
|
||||
# 4 Short offline Aborted by host 30% 13012 -
|
||||
# 5 Short offline Completed without error 00% 13004 -
|
||||
# 6 Short offline Completed without error 00% 13003 -
|
||||
# 7 Short offline Completed without error 00% 13001 -
|
||||
# 8 Short offline Completed without error 00% 12990 -
|
||||
# 9 Extended offline Completed without error 00% 12990 -
|
||||
#10 Short offline Completed without error 00% 12980 -
|
||||
#11 Short offline Completed without error 00% 12968 -
|
||||
#12 Short offline Completed without error 00% 12953 -
|
||||
#13 Short offline Completed without error 00% 12057 -
|
||||
#14 Short offline Completed without error 00% 11760 -
|
||||
#15 Short offline Completed without error 00% 10699 -
|
||||
#16 Short offline Completed without error 00% 10526 -
|
||||
#17 Short offline Completed without error 00% 10389 -
|
||||
#18 Short offline Completed without error 00% 10260 -
|
||||
#19 Short offline Completed without error 00% 10243 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 42 Celsius
|
||||
Power Cycle Min/Max Temperature: 42/43 Celsius
|
||||
Lifetime Min/Max Temperature: 6/55 Celsius
|
||||
Specified Max Operating Temperature: 37 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -40/65 Celsius
|
||||
Temperature History Size (Index): 128 (45)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0009 2 4 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
Reference in New Issue