mirror of
https://github.com/bsdhw/SMART.git
synced 2025-05-31 16:21:41 +05:30
Update of reports (new: 6895, modified: 16)
This commit is contained in:
185
HDD/Hitachi/HTS7275/HTS727550A9E364/448C7070D2A5
Normal file
185
HDD/Hitachi/HTS7275/HTS727550A9E364/448C7070D2A5
Normal file
@@ -0,0 +1,185 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p7 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Hitachi/HGST Travelstar 7K750
|
||||
Device Model: HTS727550A9E364
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000cca ...
|
||||
Firmware Version: JF3OA0E0
|
||||
User Capacity: 500,107,862,016 bytes [500 GB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 2.5 inches
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s
|
||||
Local Time is: Thu Jun 22 02:15:12 2023 EDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 45) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x51) SMART execute Offline immediate.
|
||||
No Auto Offline data collection support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
No Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 121) minutes.
|
||||
SCT capabilities: (0x003d) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 087 062 - 0
|
||||
2 Throughput_Performance P-S--K 100 100 040 - 0
|
||||
3 Spin_Up_Time PO---K 188 100 033 - 2
|
||||
4 Start_Stop_Count -O--CK 099 099 000 - 2214
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
|
||||
7 Seek_Error_Rate POSR-K 100 100 067 - 0
|
||||
8 Seek_Time_Performance P-S--K 100 100 040 - 0
|
||||
9 Power_On_Hours -O--CK 077 077 000 - 10314
|
||||
10 Spin_Retry_Count PO--CK 100 100 060 - 0
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 2146
|
||||
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
|
||||
184 End-to-End_Error PO--CK 100 100 097 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 244813922304
|
||||
188 Command_Timeout -O--CK 100 100 000 - 262168
|
||||
190 Airflow_Temperature_Cel -O---K 062 048 045 - 38 (Min/Max 37/40)
|
||||
191 G-Sense_Error_Rate -O--CK 079 079 000 - 5466
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 11927734
|
||||
193 Load_Cycle_Count -O--CK 096 096 000 - 41341
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OS-CK 100 100 000 - 0
|
||||
223 Load_Retry_Count -O-R-K 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 1 Comprehensive SMART error log
|
||||
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 9310 -
|
||||
# 2 Short offline Completed without error 00% 9310 -
|
||||
# 3 Short offline Completed without error 00% 9310 -
|
||||
# 4 Short offline Completed without error 00% 9309 -
|
||||
# 5 Short offline Completed without error 00% 9309 -
|
||||
# 6 Short offline Completed without error 00% 9309 -
|
||||
# 7 Short offline Completed without error 00% 9308 -
|
||||
# 8 Short offline Completed without error 00% 9308 -
|
||||
# 9 Short offline Completed without error 00% 9308 -
|
||||
#10 Short offline Completed without error 00% 9308 -
|
||||
#11 Short offline Completed without error 00% 9307 -
|
||||
#12 Short offline Completed without error 00% 9307 -
|
||||
#13 Short offline Completed without error 00% 9307 -
|
||||
#14 Short offline Completed without error 00% 9307 -
|
||||
#15 Short offline Completed without error 00% 9306 -
|
||||
#16 Short offline Completed without error 00% 9306 -
|
||||
#17 Short offline Completed without error 00% 9306 -
|
||||
#18 Short offline Completed without error 00% 9306 -
|
||||
#19 Short offline Completed without error 00% 9305 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 38 Celsius
|
||||
Power Cycle Min/Max Temperature: 37/40 Celsius
|
||||
Lifetime Min/Max Temperature: -7/52 Celsius
|
||||
Specified Max Operating Temperature: 33 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -40/65 Celsius
|
||||
Temperature History Size (Index): 128 (45)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: 85 (8.5 seconds)
|
||||
Write: 85 (8.5 seconds)
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0009 2 12 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 12 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
246
HDD/Hitachi/HTS7275/HTS727550A9E364/9EF381DC8A45
Normal file
246
HDD/Hitachi/HTS7275/HTS727550A9E364/9EF381DC8A45
Normal file
@@ -0,0 +1,246 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 14.0-CURRENT amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Device Model: HTS727550A9E364
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000cca ...
|
||||
Firmware Version: JF3ZD0H0
|
||||
User Capacity: 500,107,862,016 bytes [500 GB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 2.5 inches
|
||||
Device is: Not in smartctl database 7.3/5319
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Thu Sep 28 15:43:16 2023 BST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 45) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 125) minutes.
|
||||
SCT capabilities: (0x003d) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate PO-R-- 095 095 062 - 65553
|
||||
2 Throughput_Performance P-S--- 109 109 040 - 247
|
||||
3 Spin_Up_Time POS--- 246 246 033 - 1
|
||||
4 Start_Stop_Count -O--C- 096 096 000 - 7383
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 0
|
||||
7 Seek_Error_Rate PO-R-- 100 100 067 - 0
|
||||
8 Seek_Time_Performance P-S--- 095 095 040 - 57
|
||||
9 Power_On_Hours -O--C- 060 060 000 - 17867
|
||||
10 Spin_Retry_Count PO--C- 100 100 060 - 0
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 2797
|
||||
191 G-Sense_Error_Rate -O-R-- 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 099 099 000 - 2724528497
|
||||
193 Load_Cycle_Count -O--C- 045 045 000 - 555225
|
||||
194 Temperature_Celsius -O---- 181 181 000 - 33 (Min/Max 12/58)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 2
|
||||
197 Current_Pending_Sector -O---K 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ---R-- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 7
|
||||
223 Load_Retry_Count -O-R-- 100 100 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 1 Comprehensive SMART error log
|
||||
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
Device Error Count: 32039 (device log contains only the most recent 4 errors)
|
||||
CR = Command Register
|
||||
FEATR = Features Register
|
||||
COUNT = Count (was: Sector Count) Register
|
||||
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
|
||||
LH = LBA High (was: Cylinder High) Register ] LBA
|
||||
LM = LBA Mid (was: Cylinder Low) Register ] Register
|
||||
LL = LBA Low (was: Sector Number) Register ]
|
||||
DV = Device (was: Device/Head) Register
|
||||
DC = Device Control Register
|
||||
ER = Error register
|
||||
ST = Status register
|
||||
Powered_Up_Time is measured from power on, and printed as
|
||||
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
||||
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
||||
|
||||
Error 32039 [2] occurred at disk power-on lifetime: 17397 hours (724 days + 21 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
10 -- 51 00 08 00 00 3a 38 60 28 0a 00 Error: IDNF at LBA = 0x3a386028 = 976773160
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 08 00 00 00 00 3a 38 60 28 40 00 00:00:01.366 READ FPDMA QUEUED
|
||||
60 00 08 00 00 00 00 00 00 00 20 40 00 00:00:01.359 READ FPDMA QUEUED
|
||||
60 00 08 00 00 00 00 00 00 00 18 40 00 00:00:01.358 READ FPDMA QUEUED
|
||||
60 00 08 00 00 00 00 00 00 00 10 40 00 00:00:01.358 READ FPDMA QUEUED
|
||||
60 00 08 00 00 00 00 00 00 00 08 40 00 00:00:01.358 READ FPDMA QUEUED
|
||||
|
||||
Error 32038 [1] occurred at disk power-on lifetime: 17397 hours (724 days + 21 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
10 -- 51 00 08 00 00 3a 38 60 28 0a 00 Error: IDNF at LBA = 0x3a386028 = 976773160
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 08 00 00 00 00 3a 38 60 28 40 00 00:00:01.424 READ FPDMA QUEUED
|
||||
60 00 08 00 00 00 00 00 00 00 20 40 00 00:00:01.424 READ FPDMA QUEUED
|
||||
60 00 08 00 00 00 00 00 00 00 18 40 00 00:00:01.416 READ FPDMA QUEUED
|
||||
60 00 08 00 00 00 00 00 00 00 10 40 00 00:00:01.416 READ FPDMA QUEUED
|
||||
60 00 08 00 00 00 00 00 00 00 08 40 00 00:00:01.408 READ FPDMA QUEUED
|
||||
|
||||
Error 32037 [0] occurred at disk power-on lifetime: 17397 hours (724 days + 21 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
10 -- 51 00 08 00 00 3a 38 60 28 0a 00 Error: IDNF at LBA = 0x3a386028 = 976773160
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 08 00 00 00 00 3a 38 60 28 40 00 00:00:01.441 READ FPDMA QUEUED
|
||||
60 00 08 00 00 00 00 00 00 00 20 40 00 00:00:01.441 READ FPDMA QUEUED
|
||||
60 00 08 00 00 00 00 00 00 00 18 40 00 00:00:01.433 READ FPDMA QUEUED
|
||||
60 00 08 00 00 00 00 00 00 00 10 40 00 00:00:01.433 READ FPDMA QUEUED
|
||||
60 00 08 00 00 00 00 00 00 00 08 40 00 00:00:01.433 READ FPDMA QUEUED
|
||||
|
||||
Error 32036 [3] occurred at disk power-on lifetime: 17397 hours (724 days + 21 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
10 -- 51 00 08 00 00 3a 38 60 28 0a 00 Error: IDNF at LBA = 0x3a386028 = 976773160
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
60 00 08 00 00 00 00 3a 38 60 28 40 00 00:00:01.400 READ FPDMA QUEUED
|
||||
60 00 08 00 00 00 00 00 00 00 20 40 00 00:00:01.399 READ FPDMA QUEUED
|
||||
60 00 08 00 00 00 00 00 00 00 18 40 00 00:00:01.392 READ FPDMA QUEUED
|
||||
60 00 08 00 00 00 00 00 00 00 10 40 00 00:00:01.391 READ FPDMA QUEUED
|
||||
60 00 08 00 00 00 00 00 00 00 08 40 00 00:00:01.391 READ FPDMA QUEUED
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 13772 -
|
||||
# 2 Short offline Completed without error 00% 13768 -
|
||||
# 3 Vendor (0x50) Completed without error 00% 1 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 33 Celsius
|
||||
Power Cycle Min/Max Temperature: 33/34 Celsius
|
||||
Lifetime Min/Max Temperature: 12/58 Celsius
|
||||
Specified Max Operating Temperature: 34 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -40/65 Celsius
|
||||
Temperature History Size (Index): 128 (29)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0009 2 0 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 0 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
164
HDD/Hitachi/HTS7275/HTS727575A9E362/1FBF9A967EFB
Normal file
164
HDD/Hitachi/HTS7275/HTS727575A9E362/1FBF9A967EFB
Normal file
@@ -0,0 +1,164 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.3-RC1 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Device Model: HTS727575A9E362
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 000cca ...
|
||||
Firmware Version: JF4AD0F0
|
||||
User Capacity: 750,156,374,016 bytes [750 GB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: 7200 rpm
|
||||
Form Factor: 2.5 inches
|
||||
Device is: Not in smartctl database 7.3/5528
|
||||
ATA Version is: ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 2.6, 3.0 Gb/s
|
||||
Local Time is: Sat Mar 2 07:09:42 2024 GMT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 128 (minimum power consumption without standby)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 45) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 150) minutes.
|
||||
SCT capabilities: (0x003d) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate PO-R-- 100 100 062 - 0
|
||||
2 Throughput_Performance P-S--- 100 100 040 - 0
|
||||
3 Spin_Up_Time POS--- 212 212 033 - 2
|
||||
4 Start_Stop_Count -O--C- 099 099 000 - 2153
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 005 - 8
|
||||
7 Seek_Error_Rate PO-R-- 100 100 067 - 0
|
||||
8 Seek_Time_Performance P-S--- 100 100 040 - 0
|
||||
9 Power_On_Hours -O--C- 091 091 000 - 4349
|
||||
10 Spin_Retry_Count PO--C- 100 100 060 - 0
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 1704
|
||||
160 Unknown_Attribute -O--CK 100 100 000 - 0
|
||||
191 G-Sense_Error_Rate -O-R-- 100 100 000 - 0
|
||||
192 Power-Off_Retract_Count -O--CK 099 099 000 - 605590388809
|
||||
193 Load_Cycle_Count -O--C- 076 076 000 - 245521
|
||||
194 Temperature_Celsius -O---- 214 214 000 - 28 (Min/Max 5/54)
|
||||
195 Hardware_ECC_Recovered -O-R-- 068 068 000 - 33554664
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 8
|
||||
197 Current_Pending_Sector -O---K 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ---R-- 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O-R-- 200 200 000 - 0
|
||||
223 Load_Retry_Count -O-R-- 100 100 000 - 0
|
||||
254 Free_Fall_Sensor -O--CK 088 088 000 - 4294970402
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 1 Comprehensive SMART error log
|
||||
0x03 GPL R/O 1 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (1 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 28 Celsius
|
||||
Power Cycle Min/Max Temperature: 15/36 Celsius
|
||||
Lifetime Min/Max Temperature: 5/54 Celsius
|
||||
Specified Max Operating Temperature: 36 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -40/65 Celsius
|
||||
Temperature History Size (Index): 128 (76)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x0009 2 4 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000a 2 3 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
|
Reference in New Issue
Block a user