smartctl 7.3 2022-02-28 r5338 [NetBSD 9.3_STABLE sparc64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Maxtor DiamondMax Plus 8
Device Model: Maxtor 6E040L0
Serial Number: --
Firmware Version: NAR61HA0
User Capacity: 40,020,664,320 bytes [40.0 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database 7.3/5319
ATA Version is: ATA/ATAPI-7 T13/1532D revision 0
Local Time is: Wed Sep 20 17:06:42 2023 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 1021) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
No General Purpose Logging support.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 17) minutes.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
3 Spin_Up_Time 0x0027 220 220 063 Pre-fail Always - 11410
4 Start_Stop_Count 0x0032 253 253 000 Old_age Always - 84
5 Reallocated_Sector_Ct 0x0033 253 253 063 Pre-fail Always - 0
6 Read_Channel_Margin 0x0001 253 253 100 Pre-fail Offline - 0
7 Seek_Error_Rate 0x000a 253 252 000 Old_age Always - 0
8 Seek_Time_Performance 0x0027 250 236 187 Pre-fail Always - 58988
9 Power_On_Minutes 0x0032 075 075 000 Old_age Always - 584h+36m
10 Spin_Retry_Count 0x002b 253 252 157 Pre-fail Always - 0
11 Calibration_Retry_Count 0x002b 253 252 223 Pre-fail Always - 0
12 Power_Cycle_Count 0x0032 253 253 000 Old_age Always - 100
192 Power-Off_Retract_Count 0x0032 253 253 000 Old_age Always - 70
193 Load_Cycle_Count 0x0032 253 253 000 Old_age Always - 742
194 Temperature_Celsius 0x0032 253 253 000 Old_age Always - 35
195 Hardware_ECC_Recovered 0x000a 253 252 000 Old_age Always - 1315
196 Reallocated_Event_Count 0x0008 253 253 000 Old_age Offline - 0
197 Current_Pending_Sector 0x0008 253 253 000 Old_age Offline - 0
198 Offline_Uncorrectable 0x0008 253 253 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x0008 199 199 000 Old_age Offline - 0
200 Multi_Zone_Error_Rate 0x000a 253 252 000 Old_age Always - 0
201 Soft_Read_Error_Rate 0x000a 253 252 000 Old_age Always - 0
202 Data_Address_Mark_Errs 0x000a 253 248 000 Old_age Always - 0
203 Run_Out_Cancel 0x000b 253 252 180 Pre-fail Always - 2
204 Soft_ECC_Correction 0x000a 253 252 000 Old_age Always - 0
205 Thermal_Asperity_Rate 0x000a 253 252 000 Old_age Always - 0
207 Spin_High_Current 0x002a 253 252 000 Old_age Always - 0
208 Spin_Buzz 0x002a 253 252 000 Old_age Always - 0
209 Offline_Seek_Performnce 0x0024 188 184 000 Old_age Offline - 0
99 Unknown_Attribute 0x0004 253 253 000 Old_age Offline - 0
100 Unknown_Attribute 0x0004 253 253 000 Old_age Offline - 0
101 Unknown_Attribute 0x0004 253 253 000 Old_age Offline - 0
SMART Error Log Version: 1
Warning: ATA error count 3204 inconsistent with error log pointer 5
ATA Error Count: 3204 (device log contains only the most recent five errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 3204 occurred at disk power-on lifetime: 24494 hours (1020 days + 14 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 08 17 53 fd e2 Error: UNC 8 sectors at LBA = 0x02fd5317 = 50156311
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 08 17 53 fd e2 00 33d+11:23:42.704 READ DMA
c8 00 08 0f 53 fd e2 00 33d+11:23:42.688 READ DMA
c8 00 08 07 53 fd e2 00 33d+11:23:42.688 READ DMA
c8 00 08 ff 52 fd e2 00 33d+11:23:42.688 READ DMA
c8 00 08 f7 52 fd e2 00 33d+11:23:42.688 READ DMA
Error 3203 occurred at disk power-on lifetime: 24494 hours (1020 days + 14 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 38 cf 52 fd e2 Error: UNC 56 sectors at LBA = 0x02fd52cf = 50156239
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 80 cf 52 fd e2 00 33d+11:23:40.448 READ DMA
c8 00 80 4f 52 fd e2 00 33d+11:23:40.448 READ DMA
c8 00 80 cf 51 fd e2 00 33d+11:23:40.448 READ DMA
c8 00 80 4f 51 fd e2 00 33d+11:23:40.448 READ DMA
c8 00 80 cf 50 fd e2 00 33d+11:23:40.448 READ DMA
Error 3202 occurred at disk power-on lifetime: 24494 hours (1020 days + 14 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 08 17 53 fd e2 Error: UNC 8 sectors at LBA = 0x02fd5317 = 50156311
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 08 17 53 fd e2 00 33d+11:09:27.040 READ DMA
ca 00 08 07 d3 22 e2 00 33d+11:09:27.024 WRITE DMA
ca 00 08 e7 31 60 e0 00 33d+11:09:27.024 WRITE DMA
ca 00 08 2f 00 5e e0 00 33d+11:09:27.024 WRITE DMA
ca 00 80 27 c3 5c e3 00 33d+11:09:27.024 WRITE DMA
Error 3201 occurred at disk power-on lifetime: 24494 hours (1020 days + 14 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 08 17 53 fd e2 Error: UNC 8 sectors at LBA = 0x02fd5317 = 50156311
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 08 17 53 fd e2 00 33d+11:09:24.832 READ DMA
ca 00 08 07 d3 22 e2 00 33d+11:09:24.816 WRITE DMA
ca 00 10 c7 1b 60 e0 00 33d+11:09:24.816 WRITE DMA
ca 00 08 47 00 5e e0 00 33d+11:09:24.816 WRITE DMA
c8 00 01 00 00 00 e0 00 33d+11:09:24.816 READ DMA
Error 3200 occurred at disk power-on lifetime: 24494 hours (1020 days + 14 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 08 17 53 fd e2 Error: UNC 8 sectors at LBA = 0x02fd5317 = 50156311
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 08 17 53 fd e2 00 33d+11:09:22.576 READ DMA
ca 00 08 07 d3 22 e2 00 33d+11:09:22.576 WRITE DMA
ca 00 08 2f 1b 60 e0 00 33d+11:09:22.576 WRITE DMA
ca 00 38 bf 33 5f e0 00 33d+11:09:22.576 WRITE DMA
c8 00 08 1f 4c 34 e0 00 33d+11:09:22.560 READ DMA
SMART Self-test log structure revision number 1
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.

View File

@@ -0,0 +1,227 @@
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Maxtor DiamondMax Plus 9
Device Model: Maxtor 6Y120M0
Serial Number: --
Firmware Version: YAR511W0
User Capacity: 122,941,242,880 bytes [122 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database 7.3/5319
ATA Version is: ATA/ATAPI-7 T13/1532D revision 0
Local Time is: Tue Aug 15 15:22:15 2023 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM level is: 254 (maximum performance), recommended: 192
APM feature is: Disabled
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x80) Offline data collection activity
was never started.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 242) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
No General Purpose Logging support.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 54) minutes.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
3 Spin_Up_Time POS--K 204 204 063 - 14568
4 Start_Stop_Count -O--CK 252 252 000 - 2472
5 Reallocated_Sector_Ct PO--CK 253 253 063 - 0
6 Read_Channel_Margin P----- 253 253 100 - 0
7 Seek_Error_Rate -O-R-- 253 252 000 - 0
8 Seek_Time_Performance POS--K 251 230 187 - 64275
9 Power_On_Minutes -O--CK 222 222 000 - 1004h+48m
10 Spin_Retry_Count PO-R-K 253 252 157 - 0
11 Calibration_Retry_Count PO-R-K 253 252 223 - 0
12 Power_Cycle_Count -O--CK 248 248 000 - 2245
192 Power-Off_Retract_Count -O--CK 253 253 000 - 0
193 Load_Cycle_Count -O--CK 253 253 000 - 0
194 Temperature_Celsius -O--CK 253 253 000 - 34
195 Hardware_ECC_Recovered -O-R-- 253 252 000 - 5279
196 Reallocated_Event_Count ---R-- 253 253 000 - 0
197 Current_Pending_Sector ---R-- 253 253 000 - 0
198 Offline_Uncorrectable ---R-- 253 253 000 - 0
199 UDMA_CRC_Error_Count ---R-- 199 198 000 - 1
200 Multi_Zone_Error_Rate -O-R-- 253 252 000 - 0
201 Soft_Read_Error_Rate -O-R-- 253 252 000 - 18
202 Data_Address_Mark_Errs -O-R-- 253 252 000 - 0
203 Run_Out_Cancel PO-R-- 253 252 180 - 3
204 Soft_ECC_Correction -O-R-- 253 252 000 - 0
205 Thermal_Asperity_Rate -O-R-- 253 252 000 - 0
207 Spin_High_Current -O-R-K 253 252 000 - 0
208 Spin_Buzz -O-R-K 253 252 000 - 0
209 Offline_Seek_Performnce --S--K 189 189 000 - 0
99 Unknown_Attribute --S--- 253 253 000 - 0
100 Unknown_Attribute --S--- 253 253 000 - 0
101 Unknown_Attribute --S--- 253 253 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
Read SMART Log Directory failed: Input/output error
General Purpose Log Directory not supported
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
SMART Error Log Version: 1
Warning: ATA error count 34 inconsistent with error log pointer 5
ATA Error Count: 34 (device log contains only the most recent five errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 34 occurred at disk power-on lifetime: 10143 hours (422 days + 15 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
10 51 01 3f ef 4f ee Error: IDNF at LBA = 0x0e4fef3f = 240119615
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
ca 00 01 3f ef 4f ee 00 00:17:30.688 WRITE DMA
c8 00 01 3f ef 4f ee 00 00:17:30.656 READ DMA
c8 00 01 3f 00 00 e0 00 00:17:30.640 READ DMA
ec 00 00 00 00 00 a0 00 00:17:30.640 IDENTIFY DEVICE
c8 00 01 3f 00 00 e0 00 00:17:30.640 READ DMA
Error 33 occurred at disk power-on lifetime: 10143 hours (422 days + 15 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
10 51 01 3f ef 4f ee Error: IDNF 1 sectors at LBA = 0x0e4fef3f = 240119615
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 01 3f ef 4f ee 00 00:17:30.656 READ DMA
c8 00 01 3f 00 00 e0 00 00:17:30.640 READ DMA
ec 00 00 00 00 00 a0 00 00:17:30.640 IDENTIFY DEVICE
c8 00 01 3f 00 00 e0 00 00:17:30.640 READ DMA
ec 00 00 00 00 00 a0 00 00:17:30.640 IDENTIFY DEVICE
Error 32 occurred at disk power-on lifetime: 8867 hours (369 days + 11 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 00 c7 bf 8b ed Error: ICRC, ABRT at LBA = 0x0d8bbfc7 = 227262407
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 40 c7 bf 8b ed 00 12:06:01.824 READ DMA
c8 00 08 87 1d 4a e7 00 12:06:01.808 READ DMA
c8 00 08 0f 23 4a e7 00 12:06:01.808 READ DMA
c8 00 08 8f 1c 4a e7 00 12:06:01.808 READ DMA
c8 00 40 ef 5c 88 ed 00 12:06:01.792 READ DMA
Error 31 occurred at disk power-on lifetime: 8792 hours (366 days + 8 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 00 7f c5 8b ed Error: ICRC, ABRT at LBA = 0x0d8bc57f = 227263871
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 d0 40 7f c5 8b ed 00 03:33:47.504 READ DMA
c8 d0 40 77 5d 88 ed 00 03:33:47.504 READ DMA
c8 d0 40 57 5c 88 ed 00 03:33:47.504 READ DMA
c8 d0 08 3f 61 ca e0 00 03:33:47.488 READ DMA
c8 d0 08 6f 2d 4a e7 00 03:33:47.488 READ DMA
Error 30 occurred at disk power-on lifetime: 8058 hours (335 days + 18 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 00 1f c3 9a e8 Error: ICRC, ABRT at LBA = 0x089ac31f = 144360223
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 08 1f c3 9a e8 00 04:17:30.368 READ DMA
c8 00 08 d7 e3 9c e8 00 04:17:30.352 READ DMA
c8 00 08 ef c1 9a e8 00 04:17:30.352 READ DMA
c8 00 08 bf b9 98 e8 00 04:17:30.352 READ DMA
c8 00 08 19 37 39 ee 00 04:17:30.352 READ DMA
SMART Extended Self-test Log (GP Log 0x07) not supported
SMART Self-test log structure revision number 1
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Commands not supported
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11) not supported

View File

@@ -0,0 +1,161 @@
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.2-STABLE amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Device Model: Maxtor 7B300S0
Serial Number: --
Firmware Version: BANC1WE0
User Capacity: 300,090,728,448 bytes [300 GB]
Sector Size: 512 bytes logical/physical
Device is: Not in smartctl database 7.3/5319
ATA Version is: ATA/ATAPI-7 T13/1532D revision 0
Local Time is: Sun May 14 11:30:28 2023 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM level is: 192 (intermediate), recommended: 192
APM feature is: Disabled
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 118) The previous self-test completed having
the read element of the test failed.
Total time to complete Offline
data collection: ( 2283) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 118) minutes.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
3 Spin_Up_Time POS--K 184 177 063 - 21732
4 Start_Stop_Count -O--CK 253 253 000 - 476
5 Reallocated_Sector_Ct PO--CK 252 252 063 - 11
6 Read_Channel_Margin P----- 253 253 100 - 0
7 Seek_Error_Rate -O-R-- 253 252 000 - 0
8 Seek_Time_Performance POS--K 250 237 187 - 63342
9 Power_On_Hours -O--CK 001 001 000 - 35839
10 Spin_Retry_Count PO-R-K 253 252 157 - 0
11 Calibration_Retry_Count PO-R-K 253 252 223 - 0
12 Power_Cycle_Count -O--CK 252 252 000 - 480
192 Power-Off_Retract_Count -O--CK 253 253 000 - 0
193 Load_Cycle_Count -O--CK 253 253 000 - 0
194 Temperature_Celsius -O--CK 036 253 000 - 35
195 Hardware_ECC_Recovered -O-R-- 252 205 000 - 62881
196 Reallocated_Event_Count ---R-- 209 209 000 - 44
197 Current_Pending_Sector ---R-- 252 252 000 - 11
198 Offline_Uncorrectable ---R-- 181 181 000 - 72
199 UDMA_CRC_Error_Count ---R-- 199 199 000 - 0
200 Multi_Zone_Error_Rate -O-R-- 253 252 000 - 0
201 Soft_Read_Error_Rate -O-R-- 253 252 000 - 0
202 Data_Address_Mark_Errs -O-R-- 253 177 000 - 0
203 Run_Out_Cancel PO-R-- 253 221 180 - 0
204 Soft_ECC_Correction -O-R-- 253 252 000 - 0
205 Thermal_Asperity_Rate -O-R-- 253 252 000 - 0
207 Spin_High_Current -O-R-K 253 252 000 - 0
208 Spin_Buzz -O-R-K 253 252 000 - 0
209 Offline_Seek_Performnce --S--K 234 234 000 - 232
210 Unknown_Attribute -O--CK 253 252 000 - 0
211 Unknown_Attribute -O--CK 253 252 000 - 0
212 Unknown_Attribute -O--CK 253 253 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
Read SMART Log Directory failed: Input/output error
General Purpose Log Directory Version 1
Address Access R/W Size Description
0x00 GPL R/O 1 Log Directory
0x02 GPL R/O 1 Comprehensive SMART error log
0x03 GPL R/O 4 Ext. Comprehensive SMART error log
0x06 GPL R/O 1 SMART self-test log
0x10 GPL R/O 1 NCQ Command Error log
SMART Extended Comprehensive Error Log Version: 1 (4 sectors)
Device Error Count: 1
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 1 [0] occurred at disk power-on lifetime: 59961 hours (2498 days + 9 hours)
When the command that caused the error occurred, the device was in an unknown state.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
78 -- 00 00 50 00 00 07 c8 e7 32 40 00 at LBA = 0x07c8e732 = 130606898
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
61 00 20 00 50 00 00 0f 16 de cf 40 08 02:23:16.413 WRITE FPDMA QUEUED
61 00 20 00 50 00 00 0f 16 de cf 40 08 02:23:16.413 WRITE FPDMA QUEUED
60 00 c9 00 48 00 00 07 c8 e7 2f 40 08 02:23:15.860 READ FPDMA QUEUED
60 00 e0 00 48 00 00 07 c8 e6 2f 40 08 02:23:15.860 READ FPDMA QUEUED
60 00 e0 00 48 00 00 07 c8 e6 2f 40 08 02:23:15.859 READ FPDMA QUEUED
SMART Extended Self-test Log (GP Log 0x07) not supported
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed: read failure 60% 63733 375658991
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Commands not supported
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11) not supported

View File

@@ -0,0 +1,143 @@
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Seagate Maxtor DiamondMax 20
Device Model: MAXTOR STM3160211AS
Serial Number: --
Firmware Version: 3.AAE
User Capacity: 160,041,885,696 bytes [160 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database 7.3/5528
ATA Version is: ATA/ATAPI-7 (minor revision not indicated)
Local Time is: Mon Oct 30 16:46:12 2023 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 23) The self-test routine was aborted by
the host.
Total time to complete Offline
data collection: ( 430) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 54) minutes.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 114 098 006 - 74799054
3 Spin_Up_Time PO---- 095 094 000 - 0
4 Start_Stop_Count -O--CK 099 099 020 - 1650
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
7 Seek_Error_Rate POSR-- 076 060 030 - 46515555
9 Power_On_Hours -O--CK 099 099 000 - 904
10 Spin_Retry_Count PO--C- 100 100 097 - 0
12 Power_Cycle_Count -O--CK 099 099 020 - 1722
187 Reported_Uncorrect -O--CK 100 100 000 - 0
189 High_Fly_Writes -O-RCK 100 100 000 - 0
190 Airflow_Temperature_Cel -O---K 072 051 045 - 28 (Min/Max 21/28)
194 Temperature_Celsius -O---K 028 049 000 - 28 (0 19 0 0 0)
195 Hardware_ECC_Recovered -O-RC- 080 046 000 - 192923129
197 Current_Pending_Sector -O--C- 100 100 000 - 0
198 Offline_Uncorrectable ----C- 100 100 000 - 0
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 1
200 Multi_Zone_Error_Rate ------ 100 253 000 - 0
202 Data_Address_Mark_Errs -O--CK 100 253 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 GPL,SL R/O 1 Summary SMART error log
0x02 GPL,SL R/O 5 Comprehensive SMART error log
0x03 GPL,SL R/O 5 Ext. Comprehensive SMART error log
0x06 GPL,SL R/O 1 SMART self-test log
0x07 GPL,SL R/O 1 Extended self-test log
0x09 GPL,SL R/W 1 Selective self-test log
0x10 GPL,SL R/O 1 NCQ Command Error log
0x11 GPL,SL R/O 1 SATA Phy Event Counters log
0x20 GPL,SL R/O 1 Streaming performance log
0x21 GPL,SL R/O 1 Write stream error log
0x22 GPL,SL R/O 1 Read stream error log
0x23 GPL,SL R/O 1 Delayed sector log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0 GPL,SL VS 1 Device vendor specific log
0xa1 GPL,SL VS 20 Device vendor specific log
0xa2 GPL,SL VS 101 Device vendor specific log
0xa8 GPL,SL VS 20 Device vendor specific log
0xa9 GPL,SL VS 1 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
0xff GPL - 23040 Reserved
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Aborted by host 70% 849 -
# 2 Short offline Aborted by host 70% 849 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Commands not supported
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x000a 2 6 Device-to-host register FISes sent due to a COMRESET
0x0001 2 0 Command failed due to ICRC error
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS

View File

@@ -0,0 +1,210 @@
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Seagate Maxtor DiamondMax 21
Device Model: MAXTOR STM3160215AS
Serial Number: --
Firmware Version: 3.AAD
User Capacity: 160,041,885,696 bytes [160 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database 7.3/5319
ATA Version is: ATA/ATAPI-7 (minor revision not indicated)
Local Time is: Wed Nov 22 02:43:37 2023 UTC
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART Status not supported: Incomplete response, ATA output registers missing
SMART overall-health self-assessment test result: PASSED
Warning: This result is based on an Attribute check.
See vendor-specific Attribute list for marginal Attributes.
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 430) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 54) minutes.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 118 087 006 - 173434882
3 Spin_Up_Time PO---- 099 097 000 - 0
4 Start_Stop_Count -O--CK 094 094 020 - 6366
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
7 Seek_Error_Rate POSR-- 087 060 030 - 503149913
9 Power_On_Hours -O--CK 085 085 000 - 13934
10 Spin_Retry_Count PO--C- 100 100 097 - 0
12 Power_Cycle_Count -O--CK 095 095 020 - 5402
187 Reported_Uncorrect -O--CK 100 100 000 - 0
189 High_Fly_Writes -O-RCK 100 100 000 - 0
190 Airflow_Temperature_Cel -O---K 054 031 045 Past 46 (137 102 46 46 0)
194 Temperature_Celsius -O---K 046 069 000 - 46 (0 24 0 0 0)
195 Hardware_ECC_Recovered -O-RC- 084 067 000 - 62462980
197 Current_Pending_Sector -O--C- 100 100 000 - 0
198 Offline_Uncorrectable ----C- 100 100 000 - 0
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
200 Multi_Zone_Error_Rate ------ 100 253 000 - 0
202 Data_Address_Mark_Errs -O--CK 100 253 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 GPL,SL R/O 1 Summary SMART error log
0x02 GPL,SL R/O 5 Comprehensive SMART error log
0x03 GPL,SL R/O 5 Ext. Comprehensive SMART error log
0x06 GPL,SL R/O 1 SMART self-test log
0x07 GPL,SL R/O 1 Extended self-test log
0x09 GPL,SL R/W 1 Selective self-test log
0x10 GPL,SL R/O 1 NCQ Command Error log
0x11 GPL,SL R/O 1 SATA Phy Event Counters log
0x20 GPL,SL R/O 1 Streaming performance log [OBS-8]
0x21 GPL,SL R/O 1 Write stream error log
0x22 GPL,SL R/O 1 Read stream error log
0x23 GPL,SL R/O 1 Delayed sector log [OBS-8]
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0 GPL,SL VS 1 Device vendor specific log
0xa1 GPL,SL VS 20 Device vendor specific log
0xa2 GPL,SL VS 101 Device vendor specific log
0xa8 GPL,SL VS 20 Device vendor specific log
0xa9 GPL,SL VS 1 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
0xff GPL - 23040 Reserved
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
Device Error Count: 2
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 2 [1] occurred at disk power-on lifetime: 10172 hours (423 days + 20 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
10 -- 51 00 10 00 00 00 00 00 00 e0 00 Error: IDNF 16 sectors at LBA = 0x00000000 = 0
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 20 00 10 00 12 9e 00 a1 a1 e0 00 00:42:04.608 READ DMA EXT
25 00 20 00 10 00 12 9c 00 a1 f1 e0 00 00:42:04.607 READ DMA EXT
25 00 20 00 10 00 12 9c 00 a1 e1 e0 00 00:42:04.607 READ DMA EXT
25 00 20 00 10 00 12 9c 00 a1 d1 e0 00 00:42:04.607 READ DMA EXT
25 00 20 00 10 00 12 9c 00 a1 c1 e0 00 00:42:04.607 READ DMA EXT
Error 1 [0] occurred at disk power-on lifetime: 10172 hours (423 days + 20 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
10 -- 51 00 10 00 00 00 00 00 00 e0 00 Error: IDNF 16 sectors at LBA = 0x00000000 = 0
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
25 00 20 00 10 00 12 9e 00 a1 a1 e0 00 00:37:13.269 READ DMA EXT
25 00 20 00 10 00 12 9c 00 a1 f1 e0 00 00:37:13.269 READ DMA EXT
25 00 20 00 10 00 12 9c 00 a1 e1 e0 00 00:37:13.268 READ DMA EXT
25 00 20 00 10 00 12 9c 00 a1 d1 e0 00 00:37:13.268 READ DMA EXT
25 00 20 00 10 00 12 9c 00 a1 c1 e0 00 00:37:13.268 READ DMA EXT
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 13404 -
# 2 Short offline Completed without error 00% 13399 -
# 3 Short offline Interrupted (host reset) 70% 13398 -
# 4 Short offline Completed without error 00% 13391 -
# 5 Short offline Completed without error 00% 13385 -
# 6 Short offline Completed without error 00% 13384 -
# 7 Short offline Completed without error 00% 13381 -
# 8 Short offline Completed without error 00% 13355 -
# 9 Short offline Completed without error 00% 13346 -
#10 Short offline Completed without error 00% 13344 -
#11 Short offline Completed without error 00% 13343 -
#12 Short offline Completed without error 00% 13340 -
#13 Short offline Completed without error 00% 13338 -
#14 Short offline Interrupted (host reset) 90% 13334 -
#15 Short offline Completed without error 00% 13323 -
#16 Short offline Completed without error 00% 13317 -
#17 Short offline Completed without error 00% 13303 -
#18 Short offline Completed without error 00% 13302 -
#19 Short offline Interrupted (host reset) 90% 13301 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Commands not supported
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x000a 2 8 Device-to-host register FISes sent due to a COMRESET
0x0001 2 0 Command failed due to ICRC error
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS

View File

@@ -0,0 +1,145 @@
smartctl 7.2 2021-09-14 r5236 [FreeBSD 12.1-RELEASE-p22-HBSD amd64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Seagate Maxtor DiamondMax 20
Device Model: MAXTOR STM380211AS
Serial Number: --
Firmware Version: 3.AAE
User Capacity: 80,026,361,856 bytes [80.0 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA/ATAPI-7 (minor revision not indicated)
Local Time is: Sun May 5 20:02:36 2024 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
See vendor-specific Attribute list for marginal Attributes.
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 430) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 27) minutes.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 085 073 006 - 12093830
3 Spin_Up_Time PO---- 095 094 000 - 0
4 Start_Stop_Count -O--CK 100 100 020 - 761
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 1
7 Seek_Error_Rate POSR-- 087 060 030 - 576996816
9 Power_On_Hours -O--CK 070 070 000 - 26401
10 Spin_Retry_Count PO--C- 100 100 097 - 0
12 Power_Cycle_Count -O--CK 100 100 020 - 857
187 Reported_Uncorrect -O--CK 100 100 000 - 0
189 High_Fly_Writes -O-RCK 100 100 000 - 0
190 Airflow_Temperature_Cel -O---K 050 045 045 Past 50 (Min/Max 47/51)
194 Temperature_Celsius -O---K 050 055 000 - 50 (0 11 0 0 0)
195 Hardware_ECC_Recovered -O-RC- 046 041 000 - 97995876
197 Current_Pending_Sector -O--C- 100 100 000 - 0
198 Offline_Uncorrectable ----C- 100 100 000 - 0
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
200 Multi_Zone_Error_Rate ------ 100 253 000 - 0
202 Data_Address_Mark_Errs -O--CK 100 253 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 GPL,SL R/O 1 Summary SMART error log
0x02 GPL,SL R/O 5 Comprehensive SMART error log
0x03 GPL,SL R/O 5 Ext. Comprehensive SMART error log
0x06 GPL,SL R/O 1 SMART self-test log
0x07 GPL,SL R/O 1 Extended self-test log
0x09 GPL,SL R/W 1 Selective self-test log
0x10 GPL,SL R/O 1 NCQ Command Error log
0x11 GPL,SL R/O 1 SATA Phy Event Counters log
0x20 GPL,SL R/O 1 Streaming performance log [OBS-8]
0x21 GPL,SL R/O 1 Write stream error log
0x22 GPL,SL R/O 1 Read stream error log
0x23 GPL,SL R/O 1 Delayed sector log [OBS-8]
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0 GPL,SL VS 1 Device vendor specific log
0xa1 GPL,SL VS 20 Device vendor specific log
0xa2 GPL,SL VS 101 Device vendor specific log
0xa8 GPL,SL VS 20 Device vendor specific log
0xa9 GPL,SL VS 1 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
0xff GPL - 23040 Reserved
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
No Errors Logged
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended offline Completed without error 00% 8010 -
# 2 Conveyance offline Completed without error 00% 6730 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Commands not supported
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x000a 2 13 Device-to-host register FISes sent due to a COMRESET
0x0001 2 0 Command failed due to ICRC error
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS

View File

@@ -0,0 +1,292 @@
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.2-RELEASE-p2 amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Seagate Maxtor DiamondMax 21
Device Model: MAXTOR STM380215AS
Serial Number: --
Firmware Version: 4.AAB
User Capacity: 80,025,280,000 bytes [80.0 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database 7.3/5319
ATA Version is: ATA/ATAPI-7 (minor revision not indicated)
Local Time is: Tue Aug 22 17:25:06 2023 -03
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
See vendor-specific Attribute list for marginal Attributes.
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 25) The self-test routine was aborted by
the host.
Total time to complete Offline
data collection: ( 430) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 27) minutes.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 100 253 006 - 0
3 Spin_Up_Time PO---- 098 097 000 - 0
4 Start_Stop_Count -O--CK 088 088 020 - 12619
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 2
7 Seek_Error_Rate POSR-- 087 060 030 - 643533396
9 Power_On_Hours -O--CK 093 093 000 - 6835
10 Spin_Retry_Count PO--C- 100 100 097 - 0
12 Power_Cycle_Count -O--CK 087 087 020 - 13549
187 Reported_Uncorrect -O--CK 001 001 000 - 181
189 High_Fly_Writes -O-RCK 100 100 000 - 0
190 Airflow_Temperature_Cel -O---K 056 041 045 Past 44 (Min/Max 40/45 #8)
194 Temperature_Celsius -O---K 044 059 000 - 44 (0 19 0 0 0)
195 Hardware_ECC_Recovered -O-RC- 063 054 000 - 21936604
197 Current_Pending_Sector -O--C- 084 001 000 - 328
198 Offline_Uncorrectable ----C- 084 001 000 - 328
199 UDMA_CRC_Error_Count -OSRCK 200 155 000 - 2536
200 Multi_Zone_Error_Rate ------ 100 253 000 - 0
202 Data_Address_Mark_Errs -O--CK 100 253 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 GPL,SL R/O 1 Summary SMART error log
0x02 GPL,SL R/O 5 Comprehensive SMART error log
0x03 GPL,SL R/O 5 Ext. Comprehensive SMART error log
0x06 GPL,SL R/O 1 SMART self-test log
0x07 GPL,SL R/O 1 Extended self-test log
0x09 GPL,SL R/W 1 Selective self-test log
0x10 GPL,SL R/O 1 NCQ Command Error log
0x11 GPL,SL R/O 1 SATA Phy Event Counters log
0x20 GPL,SL R/O 1 Streaming performance log [OBS-8]
0x21 GPL,SL R/O 1 Write stream error log
0x22 GPL,SL R/O 1 Read stream error log
0x23 GPL,SL R/O 1 Delayed sector log [OBS-8]
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0 GPL,SL VS 1 Device vendor specific log
0xa1 GPL,SL VS 20 Device vendor specific log
0xa2 GPL,SL VS 101 Device vendor specific log
0xa8 GPL,SL VS 20 Device vendor specific log
0xa9 GPL,SL VS 1 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
0xff GPL - 23040 Reserved
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
Device Error Count: 1482 (device log contains only the most recent 20 errors)
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 1482 [1] occurred at disk power-on lifetime: 6715 hours (279 days + 19 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
10 -- 51 01 01 00 01 b2 00 4e 6b e9 00
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
37 00 00 01 01 00 09 f0 00 50 6e e9 00 00:05:40.837 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
27 00 00 00 00 00 09 f0 00 50 6e e0 00 00:05:39.486 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
37 00 00 00 00 00 09 f0 00 50 6e e9 00 00:05:39.433 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
27 00 00 01 01 00 09 f0 00 50 6e e0 00 00:05:39.433 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
37 00 00 01 01 00 09 f0 00 50 6e e9 00 00:05:39.433 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
Error 1481 [0] occurred at disk power-on lifetime: 6715 hours (279 days + 19 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
10 -- 51 01 01 00 01 b2 00 4e 6b e9 00
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
37 00 00 01 01 00 09 f0 00 50 6e e9 00 00:05:40.837 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
27 00 00 00 00 00 09 f0 00 50 6e e0 00 00:05:39.486 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
37 00 00 00 00 00 09 f0 00 50 6e e9 00 00:05:39.433 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
27 00 00 00 01 00 09 f8 00 50 af e0 00 00:05:39.433 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
29 00 00 00 01 00 09 f8 00 50 af e0 00 00:05:39.433 READ MULTIPLE EXT
Error 1480 [19] occurred at disk power-on lifetime: 6713 hours (279 days + 17 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 03 2b 00 c8 72 e3 00 Error: UNC at LBA = 0x32b00c872 = 13606373490
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 00 00 02 00 03 2b 00 c8 72 e3 00 00:02:22.740 READ DMA
27 00 00 00 00 00 00 00 00 00 00 e0 00 00:02:22.737 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
ec 00 00 01 00 00 ff ff 00 ff ff a0 00 00:02:29.647 IDENTIFY DEVICE
ef 00 03 00 42 00 ff ff 00 ff ff a0 00 00:02:29.591 SET FEATURES [Set transfer mode]
27 00 00 00 00 00 00 00 00 00 00 e0 00 00:02:29.589 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
Error 1479 [18] occurred at disk power-on lifetime: 6713 hours (279 days + 17 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 03 2b 00 c8 72 e3 00 Error: UNC at LBA = 0x32b00c872 = 13606373490
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 00 00 02 00 03 2b 00 c8 72 e3 00 00:02:22.740 READ DMA
27 00 00 00 00 00 00 00 00 00 00 e0 00 00:02:22.737 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
ec 00 00 01 00 00 ff ff 00 ff ff a0 00 00:02:22.722 IDENTIFY DEVICE
ef 00 03 00 42 00 ff ff 00 ff ff a0 00 00:02:22.659 SET FEATURES [Set transfer mode]
27 00 00 00 00 00 00 00 00 00 00 e0 00 00:02:22.657 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
Error 1478 [17] occurred at disk power-on lifetime: 6715 hours (279 days + 19 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
10 -- 51 01 01 00 01 b2 00 4e 6b e9 00
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
37 00 00 01 01 00 09 f0 00 50 6e e9 00 00:05:40.837 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
27 00 00 00 00 00 09 f0 00 50 6e e0 00 00:05:39.486 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
37 00 00 00 00 00 09 f0 00 50 6e e9 00 00:05:39.433 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
27 00 00 01 01 00 09 f0 00 50 6e e0 00 00:05:39.433 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
37 00 00 01 01 00 09 f0 00 50 6e e9 00 00:05:39.433 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
Error 1477 [16] occurred at disk power-on lifetime: 6715 hours (279 days + 19 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
10 -- 51 01 01 00 01 b2 00 4e 6b e9 00
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
37 00 00 01 01 00 09 f0 00 50 6e e9 00 00:05:40.837 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
27 00 00 00 00 00 09 f0 00 50 6e e0 00 00:05:39.486 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
37 00 00 00 00 00 09 f0 00 50 6e e9 00 00:05:39.433 SET NATIVE MAX ADDRESS EXT [OBS-ACS-3]
27 00 00 00 01 00 09 f8 00 50 af e0 00 00:05:39.433 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
29 00 00 00 01 00 09 f8 00 50 af e0 00 00:05:39.433 READ MULTIPLE EXT
Error 1476 [15] occurred at disk power-on lifetime: 6713 hours (279 days + 17 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 03 2b 00 c8 72 e3 00 Error: UNC at LBA = 0x32b00c872 = 13606373490
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 00 00 02 00 03 2b 00 c8 72 e3 00 00:02:22.740 READ DMA
27 00 00 00 00 00 00 00 00 00 00 e0 00 00:02:22.737 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
ec 00 00 01 00 00 ff ff 00 ff ff a0 00 00:02:29.647 IDENTIFY DEVICE
ef 00 03 00 42 00 ff ff 00 ff ff a0 00 00:02:29.591 SET FEATURES [Set transfer mode]
27 00 00 00 00 00 00 00 00 00 00 e0 00 00:02:29.589 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
Error 1475 [14] occurred at disk power-on lifetime: 6713 hours (279 days + 17 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 00 00 03 2b 00 c8 72 e3 00 Error: UNC at LBA = 0x32b00c872 = 13606373490
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 00 00 02 00 03 2b 00 c8 72 e3 00 00:02:22.740 READ DMA
27 00 00 00 00 00 00 00 00 00 00 e0 00 00:02:22.737 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
ec 00 00 01 00 00 ff ff 00 ff ff a0 00 00:02:22.722 IDENTIFY DEVICE
ef 00 03 00 42 00 ff ff 00 ff ff a0 00 00:02:22.659 SET FEATURES [Set transfer mode]
27 00 00 00 00 00 00 00 00 00 00 e0 00 00:02:22.657 READ NATIVE MAX ADDRESS EXT [OBS-ACS-3]
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended offline Aborted by host 90% 6071 -
# 2 Short offline Completed without error 00% 5997 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Commands not supported
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x000a 2 8 Device-to-host register FISes sent due to a COMRESET
0x0001 2 0 Command failed due to ICRC error
0x0003 2 0 R_ERR response for device-to-host data FIS
0x0004 2 0 R_ERR response for host-to-device data FIS
0x0006 2 0 R_ERR response for device-to-host non-data FIS
0x0007 2 0 R_ERR response for host-to-device non-data FIS