1
0
mirror of https://github.com/bsdhw/SMART.git synced 2025-05-31 16:21:41 +05:30

Update of reports (new: 6895, modified: 16)

This commit is contained in:
Andrey Ponomarenko
2025-01-05 01:57:11 +03:00
parent e3bee1f876
commit 2a811b67c1
6911 changed files with 1114213 additions and 734 deletions

View File

@@ -0,0 +1,154 @@
smartctl 7.2 2021-09-14 r5236 [FreeBSD 12.1-RELEASE-p22-HBSD amd64] (local build)
Copyright (C) 2002-20, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: SAMSUNG SpinPoint P80 SD
Device Model: SAMSUNG HD080HJ
Serial Number: --
Firmware Version: ZH100-47
User Capacity: 80,026,361,856 bytes [80.0 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database [for details use: -P show]
ATA Version is: ATA/ATAPI-7 T13/1532D revision 4a
Local Time is: Sun May 5 20:02:36 2024 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM level is: 254 (maximum performance), recommended: 254
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x02) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 1825) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 30) minutes.
SCT capabilities: (0x003f) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 100 100 051 - 0
3 Spin_Up_Time POS--- 253 253 025 - 3968
4 Start_Stop_Count -O--CK 099 099 000 - 1530
5 Reallocated_Sector_Ct PO--CK 253 253 010 - 0
7 Seek_Error_Rate POSR-- 253 253 051 - 0
8 Seek_Time_Performance P-S--K 253 253 015 - 0
9 Power_On_Hours -O--CK 100 100 000 - 28183
10 Spin_Retry_Count PO--CK 253 253 051 - 0
11 Calibration_Retry_Count -O--C- 253 253 000 - 0
12 Power_Cycle_Count -O--CK 100 100 000 - 815
187 Reported_Uncorrect -O--CK 253 253 000 - 0
190 Airflow_Temperature_Cel -O---K 076 064 000 - 54
194 Temperature_Celsius -O---K 076 064 000 - 54
195 Hardware_ECC_Recovered -O-RC- 100 100 000 - 59920442
196 Reallocated_Event_Count -O--CK 253 253 000 - 0
197 Current_Pending_Sector -O--C- 253 253 000 - 0
198 Offline_Uncorrectable ----CK 253 253 000 - 0
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 1
200 Multi_Zone_Error_Rate -O-R-- 100 100 000 - 0
201 Soft_Read_Error_Rate -O-R-- 100 100 000 - 0
202 Data_Address_Mark_Errs -O--CK 098 098 000 - 784
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 2 Comprehensive SMART error log
0x03 GPL R/O 2 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
SMART Extended Comprehensive Error Log Version: 1 (2 sectors)
Invalid Error Log index = 0x0800 (reserved = 0x00)
SMART Extended Self-test Log (GP Log 0x07) not supported
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended offline Completed without error 00% 7036 -
# 2 Extended offline Completed without error 00% 4903 -
SMART Selective self-test log data structure revision number 0
Note: revision number not 1 implies that no selective self-test has ever been run
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 2
SCT Version (vendor specific): 256 (0x0100)
Device State: Active (0)
Current Temperature: 54 Celsius
Power Cycle Min/Max Temperature: --/55 Celsius
Lifetime Min/Max Temperature: --/60 Celsius
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 10/55 Celsius
Min/Max Temperature Limit: 5/60 Celsius
Temperature History Size (Index): 128 (50)
SCT Error Recovery Control:
Read: Disabled
Write: Disabled
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 2 0 Command failed due to ICRC error
0x000a 2 6 Device-to-host register FISes sent due to a COMRESET
0x0008 2 0 Device-to-host non-data FIS retries
0x0009 2 0 Transition from drive PhyRdy to drive PhyNRdy
0x000b 2 0 CRC errors within host-to-device FIS
0x000d 2 0 Non-CRC errors within host-to-device FIS
0x8001 2 0 Vendor specific