smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p7 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: SAMSUNG SpinPoint P80 SD
|
||||
Device Model: SAMSUNG HD160JJ
|
||||
Serial Number: --
|
||||
Firmware Version: ZM100-41
|
||||
User Capacity: 160,041,885,696 bytes [160 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ATA/ATAPI-7 T13/1532D revision 4a
|
||||
Local Time is: Fri Jan 12 13:19:36 2024 CET
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x02) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 3699) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 61) minutes.
|
||||
SCT capabilities: (0x003f) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 100 100 051 - 0
|
||||
3 Spin_Up_Time POS--- 100 100 025 - 5760
|
||||
4 Start_Stop_Count -O--CK 099 099 000 - 1880
|
||||
5 Reallocated_Sector_Ct PO--CK 253 253 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 253 253 051 - 0
|
||||
8 Seek_Time_Performance P-S--K 253 253 015 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 10124
|
||||
10 Spin_Retry_Count PO--CK 253 253 051 - 0
|
||||
11 Calibration_Retry_Count -O--C- 253 253 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 099 099 000 - 1120
|
||||
187 Reported_Uncorrect -O--CK 253 253 000 - 0
|
||||
190 Airflow_Temperature_Cel -O---K 136 085 000 - 34
|
||||
194 Temperature_Celsius -O---K 136 085 000 - 34
|
||||
195 Hardware_ECC_Recovered -O-RC- 100 100 000 - 106914952
|
||||
196 Reallocated_Event_Count -O--CK 253 253 000 - 0
|
||||
197 Current_Pending_Sector -O--C- 253 253 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 253 253 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate -O-R-- 100 100 000 - 0
|
||||
201 Soft_Read_Error_Rate -O-R-- 100 100 000 - 0
|
||||
202 Data_Address_Mark_Errs -O--CK 253 253 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 2 Comprehensive SMART error log
|
||||
0x03 GPL R/O 2 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (2 sectors)
|
||||
Invalid Error Log index = 0x0000, trying reserved byte (0x01) instead
|
||||
Device Error Count: 1
|
||||
CR = Command Register
|
||||
FEATR = Features Register
|
||||
COUNT = Count (was: Sector Count) Register
|
||||
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
|
||||
LH = LBA High (was: Cylinder High) Register ] LBA
|
||||
LM = LBA Mid (was: Cylinder Low) Register ] Register
|
||||
LL = LBA Low (was: Sector Number) Register ]
|
||||
DV = Device (was: Device/Head) Register
|
||||
DC = Device Control Register
|
||||
ER = Error register
|
||||
ST = Status register
|
||||
Powered_Up_Time is measured from power on, and printed as
|
||||
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
||||
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
||||
|
||||
Error 1 [0] occurred at disk power-on lifetime: 103 hours (4 days + 7 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
84 -- 51 00 78 00 00 03 ab e5 17 e0 00 Error: ICRC, ABRT 120 sectors at LBA = 0x03abe517 = 61596951
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
25 ff ff 00 78 00 00 03 ab e5 17 e0 00 00:00:21.063 READ DMA EXT
|
||||
25 ff ff 00 08 00 00 03 ab e3 f7 e0 00 00:00:21.063 READ DMA EXT
|
||||
25 ff ff 00 70 00 00 03 ab e3 77 e0 00 00:00:21.063 READ DMA EXT
|
||||
25 ff ff 00 18 00 00 03 ab e0 4f e0 00 00:00:21.063 READ DMA EXT
|
||||
25 ff ff 00 10 00 00 03 ab e0 07 e0 00 00:00:21.063 READ DMA EXT
|
||||
|
||||
SMART Extended Self-test Log (GP Log 0x07) not supported
|
||||
|
||||
SMART Self-test log structure revision number 1
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 0
|
||||
Note: revision number not 1 implies that no selective self-test has ever been run
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 34 Celsius
|
||||
Power Cycle Min/Max Temperature: --/40 Celsius
|
||||
Lifetime Min/Max Temperature: --/48 Celsius
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 10/55 Celsius
|
||||
Min/Max Temperature Limit: 5/60 Celsius
|
||||
Temperature History Size (Index): 128 (111)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x000a 2 8 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 3 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x8001 2 0 Vendor specific
|
||||
|
170
HDD/Samsung/HD160/HD160JJ/7D97A3EA6AE4
Normal file
170
HDD/Samsung/HD160/HD160JJ/7D97A3EA6AE4
Normal file
@@ -0,0 +1,170 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: SAMSUNG SpinPoint P80 SD
|
||||
Device Model: SAMSUNG HD160JJ
|
||||
Serial Number: --
|
||||
Firmware Version: ZM100-47
|
||||
User Capacity: 160,040,803,840 bytes [160 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ATA/ATAPI-7 T13/1532D revision 4a
|
||||
Local Time is: Thu Oct 5 10:30:20 2023 UTC
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM level is: 128 (quiet), recommended: 254
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x82) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 3723) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 62) minutes.
|
||||
SCT capabilities: (0x003f) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 100 100 051 - 0
|
||||
3 Spin_Up_Time POS--- 253 253 025 - 6144
|
||||
4 Start_Stop_Count -O--CK 083 083 000 - 17420
|
||||
5 Reallocated_Sector_Ct PO--CK 100 100 010 - 2
|
||||
7 Seek_Error_Rate POSR-- 253 253 051 - 0
|
||||
8 Seek_Time_Performance P-S--K 253 253 015 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 54983
|
||||
10 Spin_Retry_Count PO--CK 253 253 051 - 0
|
||||
11 Calibration_Retry_Count -O--C- 253 253 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 091 091 000 - 9548
|
||||
187 Reported_Uncorrect -O--CK 099 099 000 - 2
|
||||
190 Airflow_Temperature_Cel -O---K 112 043 000 - 42
|
||||
194 Temperature_Celsius -O---K 112 043 000 - 42
|
||||
195 Hardware_ECC_Recovered -O-RC- 100 100 000 - 638173
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 2
|
||||
197 Current_Pending_Sector -O--C- 253 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 253 253 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OSRCK 200 194 000 - 1
|
||||
200 Multi_Zone_Error_Rate -O-R-- 100 100 000 - 0
|
||||
201 Soft_Read_Error_Rate -O-R-- 253 100 000 - 0
|
||||
202 Data_Address_Mark_Errs -O--CK 253 253 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 2 Comprehensive SMART error log
|
||||
0x03 GPL R/O 2 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (2 sectors)
|
||||
Invalid Error Log index = 0x0800 (reserved = 0x00)
|
||||
SMART Extended Self-test Log (GP Log 0x07) not supported
|
||||
|
||||
SMART Self-test log structure revision number 1
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Extended offline Completed without error 00% 52576 -
|
||||
# 2 Extended offline Interrupted (host reset) 80% 50536 -
|
||||
# 3 Extended offline Completed without error 00% 50168 -
|
||||
# 4 Extended offline Interrupted (host reset) 80% 49952 -
|
||||
# 5 Short offline Completed without error 00% 49860 -
|
||||
# 6 Short offline Completed without error 00% 49846 -
|
||||
# 7 Short offline Completed without error 00% 49831 -
|
||||
# 8 Short offline Completed without error 00% 49816 -
|
||||
# 9 Extended offline Completed without error 00% 49805 -
|
||||
#10 Short offline Completed without error 00% 49789 -
|
||||
#11 Short offline Completed without error 00% 49783 -
|
||||
#12 Extended offline Completed without error 00% 49700 -
|
||||
#13 Extended offline Completed without error 00% 49417 -
|
||||
#14 Extended offline Completed without error 00% 49348 -
|
||||
#15 Extended offline Interrupted (host reset) 10% 47697 -
|
||||
#16 Extended offline Interrupted (host reset) 70% 34575 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 0
|
||||
Note: revision number not 1 implies that no selective self-test has ever been run
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 42 Celsius
|
||||
Power Cycle Min/Max Temperature: --/42 Celsius
|
||||
Lifetime Min/Max Temperature: --/61 Celsius
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 10/55 Celsius
|
||||
Min/Max Temperature Limit: 5/60 Celsius
|
||||
Temperature History Size (Index): 128 (47)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x000a 2 12 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 1 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x8001 2 0 Vendor specific
|
||||
|
||||
|
||||
|