mirror of
https://github.com/bsdhw/SMART.git
synced 2025-05-31 16:21:41 +05:30
Update of reports (new: 6895, modified: 16)
This commit is contained in:
163
HDD/Samsung/HM080/HM080GI/9231B329A5B7
Normal file
163
HDD/Samsung/HM080/HM080GI/9231B329A5B7
Normal file
@@ -0,0 +1,163 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: SAMSUNG SpinPoint M5
|
||||
Device Model: SAMSUNG HM080GI
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 0f0000 ...
|
||||
Firmware Version: HG100-08
|
||||
User Capacity: 80,026,361,856 bytes [80.0 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ATA8-ACS, ATA/ATAPI-7 T13/1532D revision 0
|
||||
SATA Version is: SATA 2.5, 1.5 Gb/s
|
||||
Local Time is: Tue Dec 24 07:45:43 2024 EST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
APM level is: 254 (maximum performance)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 41) The self-test routine was interrupted
|
||||
by the host with a hard or soft reset.
|
||||
Total time to complete Offline
|
||||
data collection: ( 31) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 31) minutes.
|
||||
SCT capabilities: (0x003f) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 100 100 051 - 27
|
||||
3 Spin_Up_Time POS--- 252 252 025 - 1937
|
||||
4 Start_Stop_Count -O--CK 099 099 000 - 1418
|
||||
5 Reallocated_Sector_Ct PO--CK 252 252 010 - 0
|
||||
7 Seek_Error_Rate POSR-- 252 252 051 - 0
|
||||
8 Seek_Time_Performance --S--K 252 252 015 - 0
|
||||
9 Power_On_Hours -O--CK 094 094 000 - 3375
|
||||
10 Spin_Retry_Count -O--CK 100 100 051 - 1
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 788
|
||||
191 G-Sense_Error_Rate -O--CK 100 100 000 - 56
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 179
|
||||
194 Temperature_Celsius -O---K 118 076 000 - 40 (Min/Max 21/54)
|
||||
195 Hardware_ECC_Recovered -O-RC- 001 001 000 - 34082
|
||||
196 Reallocated_Event_Count -O--CK 252 252 000 - 0
|
||||
197 Current_Pending_Sector -O--C- 252 252 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 252 252 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OS-CK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate -O-R-- 100 100 000 - 1
|
||||
201 Soft_Read_Error_Rate -O--CK 252 252 000 - 0
|
||||
223 Load_Retry_Count -O--CK 100 100 000 - 164
|
||||
225 Load_Cycle_Count -O--CK 097 097 000 - 38778
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 2 Comprehensive SMART error log
|
||||
0x03 GPL R/O 2 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x08 SL R/O 1 Power Conditions log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80 GPL,SL R/W 16 Host vendor specific log
|
||||
0x81-0x9f SL R/W 16 Host vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (2 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log (GP Log 0x07) not supported
|
||||
|
||||
SMART Self-test log structure revision number 1
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Aborted by host 150% 3374 -
|
||||
# 2 Short offline Aborted by host 150% 3374 -
|
||||
# 3 Short offline Aborted by host 150% 3374 -
|
||||
# 4 Short offline Completed without error 00% 3373 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 0
|
||||
Note: revision number not 1 implies that no selective self-test has ever been run
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Interrupted [90% left] (0-65535)
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 40 Celsius
|
||||
Power Cycle Min/Max Temperature: 37/40 Celsius
|
||||
Lifetime Min/Max Temperature: 22/54 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 15/55 Celsius
|
||||
Min/Max Temperature Limit: 10/60 Celsius
|
||||
Temperature History Size (Index): 128 (122)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 6 Command failed due to ICRC error
|
||||
0x000a 2 9 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 6 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x8001 2 0 Vendor specific
|
||||
|
Reference in New Issue
Block a user