mirror of
https://github.com/bsdhw/SMART.git
synced 2025-05-31 16:21:41 +05:30
Update of reports (new: 6895, modified: 16)
This commit is contained in:
174
HDD/Samsung/HM320/HM320JI/9A1B109AF798
Normal file
174
HDD/Samsung/HM320/HM320JI/9A1B109AF798
Normal file
@@ -0,0 +1,174 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.2-STABLE amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: SAMSUNG SpinPoint M6
|
||||
Device Model: SAMSUNG HM320JI
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 0f0000 ...
|
||||
Firmware Version: 2SS00_01
|
||||
User Capacity: 320,072,933,376 bytes [320 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ATA8-ACS, ATA/ATAPI-7 T13/1532D revision 0
|
||||
SATA Version is: SATA 2.5, 1.5 Gb/s
|
||||
Local Time is: Thu Aug 3 12:06:48 2023 BST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM level is: 128 (quiet), recommended: 254
|
||||
APM feature is: Disabled
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 32) The self-test routine was interrupted
|
||||
by the host with a hard or soft reset.
|
||||
Total time to complete Offline
|
||||
data collection: ( 121) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x5b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 121) minutes.
|
||||
SCT capabilities: (0x003f) SCT Status supported.
|
||||
SCT Error Recovery Control supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 100 100 051 - 32
|
||||
3 Spin_Up_Time POS--- 252 252 025 - 2812
|
||||
4 Start_Stop_Count -O--CK 084 084 000 - 16973
|
||||
5 Reallocated_Sector_Ct PO--CK 095 095 010 - 53
|
||||
7 Seek_Error_Rate POSR-- 252 252 051 - 0
|
||||
8 Seek_Time_Performance --S--K 252 252 015 - 0
|
||||
9 Power_On_Hours -O--CK 058 058 000 - 21332
|
||||
10 Spin_Retry_Count -O--CK 100 100 051 - 5
|
||||
12 Power_Cycle_Count -O--CK 092 092 000 - 8796
|
||||
191 G-Sense_Error_Rate -O--CK 002 002 000 - 999999
|
||||
192 Power-Off_Retract_Count -O--CK 100 100 000 - 1224
|
||||
194 Temperature_Celsius -O---K 097 040 000 - 47 (Min/Max 5/66)
|
||||
195 Hardware_ECC_Recovered -O-RC- 100 001 000 - 6350
|
||||
196 Reallocated_Event_Count -O--CK 252 252 000 - 0
|
||||
197 Current_Pending_Sector -O--C- 252 252 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 252 252 000 - 0
|
||||
199 UDMA_CRC_Error_Count -OS-CK 200 200 000 - 2
|
||||
200 Multi_Zone_Error_Rate -O-R-- 100 100 000 - 0
|
||||
201 Soft_Read_Error_Rate -O--CK 252 252 000 - 0
|
||||
223 Load_Retry_Count -O--CK 098 098 000 - 2253
|
||||
225 Load_Cycle_Count -O--CK 028 028 000 - 732529
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 2 Comprehensive SMART error log
|
||||
0x03 GPL R/O 2 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x08 SL R/O 1 Power Conditions log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80 GPL,SL R/W 16 Host vendor specific log
|
||||
0x81-0x9f SL R/W 16 Host vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (2 sectors)
|
||||
Device Error Count: 7
|
||||
CR = Command Register
|
||||
FEATR = Features Register
|
||||
COUNT = Count (was: Sector Count) Register
|
||||
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
|
||||
LH = LBA High (was: Cylinder High) Register ] LBA
|
||||
LM = LBA Mid (was: Cylinder Low) Register ] Register
|
||||
LL = LBA Low (was: Sector Number) Register ]
|
||||
DV = Device (was: Device/Head) Register
|
||||
DC = Device Control Register
|
||||
ER = Error register
|
||||
ST = Status register
|
||||
Powered_Up_Time is measured from power on, and printed as
|
||||
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
||||
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
||||
|
||||
ATA_READ_LOG_EXT (addr=0x03:0x00, page=1, n=1) failed: Input/output error
|
||||
SMART Extended Self-test Log (GP Log 0x07) not supported
|
||||
|
||||
SMART Self-test log structure revision number 1
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 0
|
||||
Note: revision number not 1 implies that no selective self-test has ever been run
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 256 (0x0100)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 47 Celsius
|
||||
Power Cycle Min/Max Temperature: 46/47 Celsius
|
||||
Lifetime Min/Max Temperature: 7/67 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 15/55 Celsius
|
||||
Min/Max Temperature Limit: 10/60 Celsius
|
||||
Temperature History Size (Index): 128 (65)
|
||||
|
||||
SCT Error Recovery Control:
|
||||
Read: Disabled
|
||||
Write: Disabled
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x000a 2 1 Device-to-host register FISes sent due to a COMRESET
|
||||
0x0008 2 0 Device-to-host non-data FIS retries
|
||||
0x0009 2 0 Transition from drive PhyRdy to drive PhyNRdy
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x000d 2 0 Non-CRC errors within host-to-device FIS
|
||||
0x8001 2 0 Vendor specific
|
||||
|
Reference in New Issue
Block a user