smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.1-RELEASE-p6 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Seagate Barracuda 7200.7 and 7200.7 Plus
Device Model: ST340014AS
Serial Number: --
Firmware Version: 3.43
User Capacity: 40,020,664,320 bytes [40.0 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database 7.3/5528
ATA Version is: ATA/ATAPI-7, ATA/ATAPI-6 T13/1410D revision 2
Local Time is: Fri Nov 29 11:23:05 2024 CET
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Unavailable
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 113) The previous self-test completed having
the read element of the test failed.
Total time to complete Offline
data collection: ( 423) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 19) minutes.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 048 044 006 - 160697845
3 Spin_Up_Time -O---- 098 097 000 - 0
4 Start_Stop_Count PO--CK 097 097 020 - 3865
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 33
7 Seek_Error_Rate POSR-- 086 060 030 - 433461133
9 Power_On_Hours -O--CK 075 075 000 - 22135
10 Spin_Retry_Count PO--C- 100 100 097 - 0
12 Power_Cycle_Count PO--CK 098 098 020 - 2624
194 Temperature_Celsius -O---K 024 048 000 - 24 (0 2 0 0 0)
195 Hardware_ECC_Recovered -O-RC- 048 044 000 - 160697845
197 Current_Pending_Sector -O--C- 100 098 000 - 6
198 Offline_Uncorrectable ----C- 100 098 000 - 6
199 UDMA_CRC_Error_Count -OSRCK 200 199 000 - 2
200 Multi_Zone_Error_Rate ------ 100 253 000 - 0
202 Data_Address_Mark_Errs -O--CK 092 245 000 - 8
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 GPL,SL R/O 1 Summary SMART error log
0x02 GPL,SL R/O 5 Comprehensive SMART error log
0x03 GPL,SL R/O 5 Ext. Comprehensive SMART error log
0x06 GPL,SL R/O 1 SMART self-test log
0x07 GPL,SL R/O 1 Extended self-test log
0x09 GPL,SL R/W 1 Selective self-test log
0x20 GPL,SL R/O 1 Streaming performance log
0x21 GPL,SL R/O 1 Write stream error log
0x22 GPL,SL R/O 1 Read stream error log
0x23 GPL,SL R/O 1 Delayed sector log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0 GPL,SL VS 1 Device vendor specific log
0xa1 GPL,SL VS 20 Device vendor specific log
0xa2 GPL,SL VS 101 Device vendor specific log
0xa8 GPL,SL VS 20 Device vendor specific log
0xa9 GPL,SL VS 1 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
0xff GPL - 23552 Reserved
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
Device Error Count: 168 (device log contains only the most recent 20 errors)
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 168 [7] occurred at disk power-on lifetime: 22131 hours (922 days + 3 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 06 01 40 00 19 d9 40 d9 e0 00 Error: UNC 1537 sectors at LBA = 0x400019d940d9 = 70369177845977
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 00 00 08 00 00 19 00 40 d8 e0 00 00:14:33.953 READ DMA
c8 00 00 00 08 00 00 19 00 40 d0 e0 00 00:14:33.952 READ DMA
c8 00 00 00 08 00 00 19 00 40 c8 e0 00 00:14:28.805 READ DMA
c8 00 00 00 08 00 00 19 00 40 c0 e0 00 00:14:28.805 READ DMA
ec 00 00 01 00 00 ff ff 00 ff ff a0 00 00:14:28.805 IDENTIFY DEVICE
Error 167 [6] occurred at disk power-on lifetime: 22131 hours (922 days + 3 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 04 03 40 00 19 c3 40 c3 e0 00 Error: UNC 1027 sectors at LBA = 0x400019c340c3 = 70369176404163
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 00 00 08 00 00 19 00 40 c0 e0 00 00:14:33.953 READ DMA
ec 00 00 01 00 00 ff ff 00 ff ff a0 00 00:14:33.952 IDENTIFY DEVICE
ef 00 03 00 45 00 ff ff 00 ff ff a0 00 00:14:28.805 SET FEATURES [Set transfer mode]
ec 00 00 01 00 00 ff ff 00 ff ff a0 00 00:14:28.805 IDENTIFY DEVICE
c8 00 00 00 08 00 00 19 00 40 b8 e0 00 00:14:28.805 READ DMA
Error 166 [5] occurred at disk power-on lifetime: 22131 hours (922 days + 3 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 05 02 40 00 19 a8 40 a8 e0 00 Error: UNC 1282 sectors at LBA = 0x400019a840a8 = 70369174634664
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 00 00 08 00 00 19 00 40 b8 e0 00 00:14:20.433 READ DMA
ca 00 00 00 08 00 00 19 00 40 a8 e0 00 00:14:20.432 WRITE DMA
ca 00 00 00 08 00 00 19 00 40 98 e0 00 00:14:28.805 WRITE DMA
ca 00 00 00 08 00 00 19 00 40 10 e0 00 00:14:28.805 WRITE DMA
ec 00 00 01 00 00 ff ff 00 ff ff a0 00 00:14:28.805 IDENTIFY DEVICE
Error 165 [4] occurred at disk power-on lifetime: 22131 hours (922 days + 3 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 05 02 40 00 19 ba 40 ba e0 00 Error: UNC 1282 sectors at LBA = 0x400019ba40ba = 70369175814330
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 00 00 08 00 00 19 00 40 b8 e0 00 00:14:20.433 READ DMA
ec 00 00 01 00 00 ff ff 00 ff ff a0 00 00:14:20.432 IDENTIFY DEVICE
ef 00 03 00 45 00 ff ff 00 ff ff a0 00 00:14:20.431 SET FEATURES [Set transfer mode]
ec 00 00 01 00 00 ff ff 00 ff ff a0 00 00:14:13.639 IDENTIFY DEVICE
c8 00 00 00 08 00 00 19 00 40 b8 e0 00 00:14:13.606 READ DMA
Error 164 [3] occurred at disk power-on lifetime: 22131 hours (922 days + 3 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 06 01 40 00 19 d9 40 d9 e0 00 Error: UNC 1537 sectors at LBA = 0x400019d940d9 = 70369177845977
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 00 00 08 00 00 19 00 40 d8 e0 00 00:14:33.953 READ DMA
c8 00 00 00 08 00 00 19 00 40 d0 e0 00 00:14:33.952 READ DMA
c8 00 00 00 08 00 00 19 00 40 c8 e0 00 00:14:28.805 READ DMA
c8 00 00 00 08 00 00 19 00 40 c0 e0 00 00:14:28.805 READ DMA
ec 00 00 01 00 00 ff ff 00 ff ff a0 00 00:14:28.805 IDENTIFY DEVICE
Error 163 [2] occurred at disk power-on lifetime: 22131 hours (922 days + 3 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 04 03 40 00 19 c3 40 c3 e0 00 Error: UNC 1027 sectors at LBA = 0x400019c340c3 = 70369176404163
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 00 00 08 00 00 19 00 40 c0 e0 00 00:14:33.953 READ DMA
ec 00 00 01 00 00 ff ff 00 ff ff a0 00 00:14:33.952 IDENTIFY DEVICE
ef 00 03 00 45 00 ff ff 00 ff ff a0 00 00:14:28.805 SET FEATURES [Set transfer mode]
ec 00 00 01 00 00 ff ff 00 ff ff a0 00 00:14:28.805 IDENTIFY DEVICE
c8 00 00 00 08 00 00 19 00 40 b8 e0 00 00:14:28.805 READ DMA
Error 162 [1] occurred at disk power-on lifetime: 22131 hours (922 days + 3 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 05 02 40 00 19 a8 40 a8 e0 00 Error: UNC 1282 sectors at LBA = 0x400019a840a8 = 70369174634664
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 00 00 08 00 00 19 00 40 b8 e0 00 00:14:20.433 READ DMA
ca 00 00 00 08 00 00 19 00 40 a8 e0 00 00:14:20.432 WRITE DMA
ca 00 00 00 08 00 00 19 00 40 98 e0 00 00:14:28.805 WRITE DMA
ca 00 00 00 08 00 00 19 00 40 10 e0 00 00:14:28.805 WRITE DMA
ec 00 00 01 00 00 ff ff 00 ff ff a0 00 00:14:28.805 IDENTIFY DEVICE
Error 161 [0] occurred at disk power-on lifetime: 22131 hours (922 days + 3 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 05 02 40 00 19 ba 40 ba e0 00 Error: UNC 1282 sectors at LBA = 0x400019ba40ba = 70369175814330
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
c8 00 00 00 08 00 00 19 00 40 b8 e0 00 00:14:20.433 READ DMA
ec 00 00 01 00 00 ff ff 00 ff ff a0 00 00:14:20.432 IDENTIFY DEVICE
ef 00 03 00 45 00 ff ff 00 ff ff a0 00 00:14:20.431 SET FEATURES [Set transfer mode]
ec 00 00 01 00 00 ff ff 00 ff ff a0 00 00:14:13.639 IDENTIFY DEVICE
c8 00 00 00 08 00 00 19 00 40 b8 e0 00 00:14:13.606 READ DMA
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed: read failure 10% 22135 7838319515691
# 2 Short offline Completed: read failure 10% 22013 7838319512568
# 3 Short offline Completed without error 00% 21848 -
# 4 Short offline Completed without error 00% 21683 -
# 5 Short offline Completed without error 00% 21518 -
# 6 Short offline Completed without error 00% 21354 -
# 7 Short offline Completed without error 00% 21189 -
# 8 Short offline Completed without error 00% 21024 -
# 9 Short offline Completed without error 00% 20858 -
#10 Short offline Completed without error 00% 20693 -
#11 Short offline Completed without error 00% 20529 -
#12 Short offline Completed without error 00% 20364 -
#13 Short offline Completed without error 00% 20330 -
#14 Short offline Completed without error 00% 20199 -
#15 Short offline Completed without error 00% 20034 -
#16 Short offline Completed without error 00% 19869 -
#17 Short offline Completed without error 00% 19704 -
#18 Short offline Completed without error 00% 19539 -
#19 Short offline Completed without error 00% 19374 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Commands not supported
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11) not supported

View File

@@ -0,0 +1,132 @@
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p7 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Seagate Barracuda 7200.7 and 7200.7 Plus
Device Model: ST340014AS
Serial Number: --
Firmware Version: 8.05
User Capacity: 40,000,000,000 bytes [40.0 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database 7.3/5528
ATA Version is: ATA/ATAPI-6 T13/1410D revision 2
Local Time is: Fri Jan 5 18:22:30 2024 GMT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM level is: 254 (maximum performance), recommended: 128
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 24) The self-test routine was aborted by
the host.
Total time to complete Offline
data collection: ( 430) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
No General Purpose Logging support.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 31) minutes.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 078 059 006 - 20243975
3 Spin_Up_Time PO---- 097 097 000 - 0
4 Start_Stop_Count -O--CK 100 100 020 - 20
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
7 Seek_Error_Rate POSR-- 088 060 030 - 735496887
9 Power_On_Hours -O--CK 089 089 000 - 9767
10 Spin_Retry_Count PO--C- 100 100 097 - 0
12 Power_Cycle_Count -O--CK 098 098 020 - 2249
194 Temperature_Celsius -O---K 049 052 000 - 49
195 Hardware_ECC_Recovered -O-RC- 060 059 000 - 20243975
197 Current_Pending_Sector -O--C- 100 100 000 - 0
198 Offline_Uncorrectable ----C- 100 100 000 - 0
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 0
200 Multi_Zone_Error_Rate ------ 100 253 000 - 0
202 Data_Address_Mark_Errs -O--CK 100 253 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory not supported
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 5 Comprehensive SMART error log
0x03 SL R/O 5 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 SL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x20 SL R/O 1 Streaming performance log
0x21 SL R/O 1 Write stream error log
0x22 SL R/O 1 Read stream error log
0x23 SL R/O 1 Delayed sector log
0x80-0x9f SL R/W 16 Host vendor specific log
0xa0 SL VS 1 Device vendor specific log
0xa1 SL VS 20 Device vendor specific log
0xa2 SL VS 101 Device vendor specific log
0xa8 SL VS 20 Device vendor specific log
0xa9 SL VS 1 Device vendor specific log
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
SMART Error Log Version: 1
No Errors Logged
SMART Extended Self-test Log (GP Log 0x07) not supported
SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Extended offline Aborted by host 80% 8734 -
# 2 Short offline Completed without error 00% 8734 -
# 3 Short offline Completed without error 00% 0 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Commands not supported
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11) not supported

View File

@@ -0,0 +1,229 @@
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p11 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Seagate Barracuda 5400.1
Device Model: ST340015A
Serial Number: --
Firmware Version: 3.01
User Capacity: 40,019,582,464 bytes [40.0 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database 7.3/5528
ATA Version is: ATA/ATAPI-6 (minor revision not indicated)
Local Time is: Fri May 24 10:38:22 2024 MSK
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 420) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
No General Purpose Logging support.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 28) minutes.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 067 054 025 - 118032423
3 Spin_Up_Time PO---- 097 096 000 - 0
4 Start_Stop_Count -O--CK 100 100 020 - 414
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 0
7 Seek_Error_Rate POSR-- 065 060 030 - 1109034680587
9 Power_On_Hours -O--CK 051 051 000 - 43573
10 Spin_Retry_Count -O--C- 100 100 000 - 0
12 Power_Cycle_Count -O--CK 097 097 020 - 3785
194 Temperature_Celsius -O---K 038 047 000 - 38
195 Hardware_ECC_Recovered -O-RC- 100 253 000 - 0
197 Current_Pending_Sector -O--C- 100 100 000 - 1
198 Offline_Uncorrectable ----C- 100 100 000 - 0
199 UDMA_CRC_Error_Count -OSRCK 200 200 000 - 13
200 Multi_Zone_Error_Rate ------ 100 253 000 - 0
202 Data_Address_Mark_Errs -O--CK 100 253 000 - 0
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory not supported
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 5 Comprehensive SMART error log
0x03 SL R/O 5 Ext. Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x07 SL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x20 SL R/O 1 Streaming performance log
0x21 SL R/O 1 Write stream error log
0x22 SL R/O 1 Read stream error log
0x23 SL R/O 1 Delayed sector log
0x80-0x9f SL R/W 16 Host vendor specific log
0xa0 SL VS 1 Device vendor specific log
0xa1 SL VS 20 Device vendor specific log
0xa2 SL VS 101 Device vendor specific log
0xa8 SL VS 20 Device vendor specific log
0xa9 SL VS 1 Device vendor specific log
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
SMART Error Log Version: 1
ATA Error Count: 1327 (device log contains only the most recent five errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 1327 occurred at disk power-on lifetime: 34711 hours (1446 days + 7 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 3c 45 5f e0 Error: UNC at LBA = 0x005f453c = 6243644
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 20 1f 45 5f e0 00 00:00:00.040 READ DMA
c8 00 20 ff 44 5f e0 00 00:00:00.292 READ DMA
c8 00 20 df 44 5f e0 00 00:00:01.888 READ DMA
c8 00 20 bf 44 5f e0 00 00:01:44.000 READ DMA
c8 00 03 07 f9 43 e0 00 00:00:00.472 READ DMA
Error 1326 occurred at disk power-on lifetime: 34652 hours (1443 days + 20 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 3c 45 5f e0 Error: UNC at LBA = 0x005f453c = 6243644
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 20 1f 45 5f e0 00 00:00:00.040 READ DMA
c8 00 20 ff 44 5f e0 00 00:01:55.000 READ DMA
c8 00 08 27 10 9f e3 00 00:00:05.779 READ DMA
c8 00 18 e7 a9 a1 e3 00 00:00:13.881 READ DMA
c8 00 28 37 76 2c e3 00 00:00:00.444 READ DMA
Error 1325 occurred at disk power-on lifetime: 10874 hours (453 days + 2 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 3c 45 5f f0 Error: UNC at LBA = 0x005f453c = 6243644
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 08 37 45 5f f0 00 00:00:03.879 READ DMA
c8 00 01 00 00 00 f0 00 00:00:21.000 READ DMA
c8 00 08 2f 45 5f f0 00 00:00:30.000 READ DMA
c8 00 80 2f 45 5f f0 00 00:58:56.000 READ DMA
c8 00 80 af 44 5f f0 00 00:00:02.914 READ DMA
Error 1324 occurred at disk power-on lifetime: 10874 hours (453 days + 2 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 3c 45 5f f0 Error: UNC at LBA = 0x005f453c = 6243644
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 80 2f 45 5f f0 00 00:00:00.028 READ DMA
c8 00 80 af 44 5f f0 00 00:00:02.914 READ DMA
c8 00 80 2f 44 5f f0 00 00:00:01.290 READ DMA
c8 00 80 af 43 5f f0 00 00:00:01.289 READ DMA
c8 00 80 2f 43 5f f0 00 00:00:01.287 READ DMA
Error 1323 occurred at disk power-on lifetime: 10874 hours (453 days + 2 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 3c 45 5f f0 Error: UNC at LBA = 0x005f453c = 6243644
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 08 37 45 5f f0 00 00:00:03.854 READ DMA
c8 00 01 00 00 00 f0 00 00:00:24.000 READ DMA
c8 00 08 37 45 5f f0 00 00:59:02.000 READ DMA
c8 00 01 00 00 00 f0 00 00:00:00.070 READ DMA
c8 00 08 3f 45 5f f0 00 00:00:20.000 READ DMA
SMART Extended Self-test Log (GP Log 0x07) not supported
SMART Self-test log structure revision number 1
No self-tests have been logged. [To run self-tests, use: smartctl -t]
Warning! SMART Selective Self-Test Log Structure error: invalid SMART checksum.
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Commands not supported
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11) not supported

View File

@@ -0,0 +1,214 @@
smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.0-RELEASE-p6 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Family: Seagate Barracuda ATA IV
Device Model: ST340016A
Serial Number: --
Firmware Version: 3.19
User Capacity: 40,020,664,320 bytes [40.0 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database 7.3/5528
ATA Version is: ATA/ATAPI-5 (minor revision not indicated)
Local Time is: Mon May 6 14:17:58 2024 CEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM level is: 128 (quiet), recommended: 128
APM feature is: Unavailable
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, NOT FROZEN [SEC1]
Wt Cache Reorder: Unavailable
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 422) seconds.
Offline data collection
capabilities: (0x1b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
No Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
No General Purpose Logging support.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 31) minutes.
SMART Attributes Data Structure revision number: 10
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-- 087 045 034 - 138133085
3 Spin_Up_Time PO---- 078 070 000 - 0
4 Start_Stop_Count -O--CK 100 100 020 - 936
5 Reallocated_Sector_Ct PO--CK 100 100 036 - 14
7 Seek_Error_Rate POSR-- 084 060 030 - 310547065
9 Power_On_Hours -O--CK 088 088 000 - 11160
10 Spin_Retry_Count PO--C- 100 100 097 - 0
12 Power_Cycle_Count -O--CK 093 093 020 - 8049
194 Temperature_Celsius -O---K 022 052 000 - 22
195 Hardware_ECC_Recovered -O-RC- 087 045 000 - 138133085
197 Current_Pending_Sector -O--C- 100 100 000 - 12
198 Offline_Uncorrectable ----C- 100 100 000 - 12
199 UDMA_CRC_Error_Count -OSRCK 200 001 000 - 25121
200 Multi_Zone_Error_Rate ------ 100 253 000 - 0
202 Data_Address_Mark_Errs -O--CK 096 249 000 - 4
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory not supported
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 5 Comprehensive SMART error log
0x06 SL R/O 1 SMART self-test log
0x80-0x9f SL R/W 16 Host vendor specific log
0xa0 SL VS 1 Device vendor specific log
0xa1 SL VS 20 Device vendor specific log
0xa2 SL VS 101 Device vendor specific log
0xa8 SL VS 20 Device vendor specific log
0xa9 SL VS 1 Device vendor specific log
SMART Extended Comprehensive Error Log (GP Log 0x03) not supported
SMART Error Log Version: 1
ATA Error Count: 35037 (device log contains only the most recent five errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 35037 occurred at disk power-on lifetime: 10232 hours (426 days + 8 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
84 51 00 40 00 60 f0 Error: ICRC, ABRT at LBA = 0x00600040 = 6291520
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 01 40 00 60 f0 00 00:00:15.640 READ DMA
00 00 00 00 00 00 00 06 00:00:15.614 NOP [Abort queued commands]
00 00 00 00 00 00 00 06 00:00:15.503 NOP [Abort queued commands]
00 00 00 00 00 00 00 06 00:00:15.385 NOP [Abort queued commands]
c8 00 01 00 00 00 f0 00 00:00:11.447 READ DMA
Error 35036 occurred at disk power-on lifetime: 4830 hours (201 days + 6 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 1c 09 00 f0 Error: UNC at LBA = 0x0000091c = 2332
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 08 18 09 00 f0 00 01:39:58.348 READ DMA
f8 00 00 00 00 00 f0 00 01:39:58.335 READ NATIVE MAX ADDRESS [OBS-ACS-3]
ec 00 00 00 00 00 b0 02 01:39:58.327 IDENTIFY DEVICE
ef 03 45 00 00 00 b0 02 01:39:58.323 SET FEATURES [Set transfer mode]
f8 00 00 00 00 00 f0 00 01:39:58.263 READ NATIVE MAX ADDRESS [OBS-ACS-3]
Error 35035 occurred at disk power-on lifetime: 4830 hours (201 days + 6 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 1c 09 00 f0 Error: UNC at LBA = 0x0000091c = 2332
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 08 18 09 00 f0 00 01:39:54.691 READ DMA
f8 00 00 00 00 00 f0 00 01:39:54.682 READ NATIVE MAX ADDRESS [OBS-ACS-3]
ec 00 00 00 00 00 b0 02 01:39:54.674 IDENTIFY DEVICE
ef 03 45 00 00 00 b0 02 01:39:54.666 SET FEATURES [Set transfer mode]
f8 00 00 00 00 00 f0 00 01:39:54.622 READ NATIVE MAX ADDRESS [OBS-ACS-3]
Error 35034 occurred at disk power-on lifetime: 4830 hours (201 days + 6 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 1c 09 00 f0 Error: UNC at LBA = 0x0000091c = 2332
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 08 18 09 00 f0 00 01:39:51.057 READ DMA
f8 00 00 00 00 00 f0 00 01:39:51.057 READ NATIVE MAX ADDRESS [OBS-ACS-3]
ec 00 00 00 00 00 b0 02 01:39:51.049 IDENTIFY DEVICE
ef 03 45 00 00 00 b0 02 01:39:51.042 SET FEATURES [Set transfer mode]
f8 00 00 00 00 00 f0 00 01:39:50.997 READ NATIVE MAX ADDRESS [OBS-ACS-3]
Error 35033 occurred at disk power-on lifetime: 4830 hours (201 days + 6 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 00 1c 09 00 f0 Error: UNC at LBA = 0x0000091c = 2332
Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 08 18 09 00 f0 00 01:39:47.445 READ DMA
f8 00 00 00 00 00 f0 00 01:39:47.444 READ NATIVE MAX ADDRESS [OBS-ACS-3]
ec 00 00 00 00 00 b0 02 01:39:47.436 IDENTIFY DEVICE
ef 03 45 00 00 00 b0 02 01:39:47.427 SET FEATURES [Set transfer mode]
f8 00 00 00 00 00 f0 00 01:39:47.380 READ NATIVE MAX ADDRESS [OBS-ACS-3]
SMART Extended Self-test Log (GP Log 0x07) not supported
SMART Self-test log structure revision number 1
No self-tests have been logged. [To run self-tests, use: smartctl -t]
Selective Self-tests/Logging not supported
SCT Commands not supported
Device Statistics (GP/SMART Log 0x04) not supported
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11) not supported