313
HDD/WDC/WD10/WD10EALX-009BA0/3D3F65EDCA81
Normal file
313
HDD/WDC/WD10/WD10EALX-009BA0/3D3F65EDCA81
Normal file
@@ -0,0 +1,313 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.0-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Western Digital Blue
|
||||
Device Model: WDC WD10EALX-009BA0
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 0014ee ...
|
||||
Firmware Version: 15.01H15
|
||||
User Capacity: 1,000,204,886,016 bytes [1.00 TB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
|
||||
Local Time is: Tue Dec 5 15:26:49 2023 EET
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Disabled
|
||||
APM feature is: Unavailable
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x84) Offline data collection activity
|
||||
was suspended by an interrupting command from host.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: (17460) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 202) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 5) minutes.
|
||||
SCT capabilities: (0x3037) SCT Status supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 200 200 051 - 0
|
||||
3 Spin_Up_Time POS--K 178 175 021 - 4091
|
||||
4 Start_Stop_Count -O--CK 100 100 000 - 225
|
||||
5 Reallocated_Sector_Ct PO--CK 200 200 140 - 0
|
||||
7 Seek_Error_Rate -OSR-K 200 200 000 - 0
|
||||
9 Power_On_Hours -O--CK 001 001 000 - 96733
|
||||
10 Spin_Retry_Count -O--CK 100 100 000 - 0
|
||||
11 Calibration_Retry_Count -O--CK 100 100 000 - 0
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 219
|
||||
192 Power-Off_Retract_Count -O--CK 200 200 000 - 160
|
||||
193 Load_Cycle_Count -O--CK 200 200 000 - 64
|
||||
194 Temperature_Celsius -O---K 103 086 000 - 44
|
||||
196 Reallocated_Event_Count -O--CK 200 200 000 - 0
|
||||
197 Current_Pending_Sector -O--CK 200 200 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 200 200 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 200 200 000 - 0
|
||||
200 Multi_Zone_Error_Rate ---R-- 200 200 000 - 0
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 5 Comprehensive SMART error log
|
||||
0x03 GPL R/O 6 Ext. Comprehensive SMART error log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa0-0xa7 GPL,SL VS 16 Device vendor specific log
|
||||
0xa8-0xb5 GPL,SL VS 1 Device vendor specific log
|
||||
0xb6 GPL VS 1 Device vendor specific log
|
||||
0xb7 GPL,SL VS 1 Device vendor specific log
|
||||
0xc0 GPL,SL VS 1 Device vendor specific log
|
||||
0xc1 GPL VS 24 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (6 sectors)
|
||||
Device Error Count: 25 (device log contains only the most recent 24 errors)
|
||||
CR = Command Register
|
||||
FEATR = Features Register
|
||||
COUNT = Count (was: Sector Count) Register
|
||||
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
|
||||
LH = LBA High (was: Cylinder High) Register ] LBA
|
||||
LM = LBA Mid (was: Cylinder Low) Register ] Register
|
||||
LL = LBA Low (was: Sector Number) Register ]
|
||||
DV = Device (was: Device/Head) Register
|
||||
DC = Device Control Register
|
||||
ER = Error register
|
||||
ST = Status register
|
||||
Powered_Up_Time is measured from power on, and printed as
|
||||
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
||||
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
||||
|
||||
Error 25 [0] occurred at disk power-on lifetime: 62225 hours (2592 days + 17 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 5b 00 00 00 77 b8 4c e1 00 Error: UNC 91 sectors at LBA = 0x0177b84c = 24623180
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
c8 00 00 00 5b 00 00 01 77 b7 ff e1 02 06:52:19.834 READ DMA
|
||||
c8 00 00 00 5b 00 00 01 77 b7 ff e1 02 06:52:18.044 READ DMA
|
||||
c8 00 00 00 5b 00 00 01 77 b7 ff e1 02 06:52:16.254 READ DMA
|
||||
c8 00 00 00 5b 00 00 01 77 b7 ff e1 02 06:52:14.464 READ DMA
|
||||
c8 00 00 00 5b 00 00 01 77 b7 ff e1 02 06:52:12.672 READ DMA
|
||||
|
||||
Error 24 [23] occurred at disk power-on lifetime: 62225 hours (2592 days + 17 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 5b 00 00 00 77 b8 4c e1 00 Error: UNC 91 sectors at LBA = 0x0177b84c = 24623180
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
c8 00 00 00 5b 00 00 01 77 b7 ff e1 02 06:52:18.044 READ DMA
|
||||
c8 00 00 00 5b 00 00 01 77 b7 ff e1 02 06:52:16.254 READ DMA
|
||||
c8 00 00 00 5b 00 00 01 77 b7 ff e1 02 06:52:14.464 READ DMA
|
||||
c8 00 00 00 5b 00 00 01 77 b7 ff e1 02 06:52:12.672 READ DMA
|
||||
c8 00 00 00 20 00 00 01 06 2b 7f e1 02 06:52:12.659 READ DMA
|
||||
|
||||
Error 23 [22] occurred at disk power-on lifetime: 62225 hours (2592 days + 17 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 5b 00 00 00 77 b8 4c e1 00 Error: UNC 91 sectors at LBA = 0x0177b84c = 24623180
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
c8 00 00 00 5b 00 00 01 77 b7 ff e1 02 06:52:16.254 READ DMA
|
||||
c8 00 00 00 5b 00 00 01 77 b7 ff e1 02 06:52:14.464 READ DMA
|
||||
c8 00 00 00 5b 00 00 01 77 b7 ff e1 02 06:52:12.672 READ DMA
|
||||
c8 00 00 00 20 00 00 01 06 2b 7f e1 02 06:52:12.659 READ DMA
|
||||
c8 00 00 00 08 00 00 0a fd f3 57 ea 02 06:52:12.659 READ DMA
|
||||
|
||||
Error 22 [21] occurred at disk power-on lifetime: 62225 hours (2592 days + 17 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 5b 00 00 00 77 b8 4c e1 00 Error: UNC 91 sectors at LBA = 0x0177b84c = 24623180
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
c8 00 00 00 5b 00 00 01 77 b7 ff e1 02 06:52:14.464 READ DMA
|
||||
c8 00 00 00 5b 00 00 01 77 b7 ff e1 02 06:52:12.672 READ DMA
|
||||
c8 00 00 00 20 00 00 01 06 2b 7f e1 02 06:52:12.659 READ DMA
|
||||
c8 00 00 00 08 00 00 0a fd f3 57 ea 02 06:52:12.659 READ DMA
|
||||
c8 00 00 00 08 00 00 0a fd f9 f3 ea 02 06:52:12.652 READ DMA
|
||||
|
||||
Error 21 [20] occurred at disk power-on lifetime: 62225 hours (2592 days + 17 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 5b 00 00 00 77 b8 4c e1 00 Error: UNC 91 sectors at LBA = 0x0177b84c = 24623180
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
c8 00 00 00 5b 00 00 01 77 b7 ff e1 02 06:52:12.672 READ DMA
|
||||
c8 00 00 00 20 00 00 01 06 2b 7f e1 02 06:52:12.659 READ DMA
|
||||
c8 00 00 00 08 00 00 0a fd f3 57 ea 02 06:52:12.659 READ DMA
|
||||
c8 00 00 00 08 00 00 0a fd f9 f3 ea 02 06:52:12.652 READ DMA
|
||||
c8 00 00 00 18 00 00 0a fd f3 3f ea 02 06:52:12.644 READ DMA
|
||||
|
||||
Error 20 [19] occurred at disk power-on lifetime: 62221 hours (2592 days + 13 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 20 00 00 00 77 b8 4c e1 00 Error: UNC 32 sectors at LBA = 0x0177b84c = 24623180
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
c8 00 00 00 20 00 00 01 77 b8 3f e1 02 02:26:43.978 READ DMA
|
||||
c8 00 00 00 20 00 00 01 77 b8 3f e1 02 02:26:42.188 READ DMA
|
||||
c8 00 00 00 20 00 00 01 77 b8 3f e1 02 02:26:40.398 READ DMA
|
||||
c8 00 00 00 20 00 00 01 77 b8 3f e1 02 02:26:38.609 READ DMA
|
||||
c8 00 00 00 20 00 00 01 77 b8 3f e1 02 02:26:36.816 READ DMA
|
||||
|
||||
Error 19 [18] occurred at disk power-on lifetime: 62221 hours (2592 days + 13 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 20 00 00 00 77 b8 4c e1 00 Error: UNC 32 sectors at LBA = 0x0177b84c = 24623180
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
c8 00 00 00 20 00 00 01 77 b8 3f e1 02 02:26:42.188 READ DMA
|
||||
c8 00 00 00 20 00 00 01 77 b8 3f e1 02 02:26:40.398 READ DMA
|
||||
c8 00 00 00 20 00 00 01 77 b8 3f e1 02 02:26:38.609 READ DMA
|
||||
c8 00 00 00 20 00 00 01 77 b8 3f e1 02 02:26:36.816 READ DMA
|
||||
c8 00 00 00 20 00 00 01 06 2b 7f e1 02 02:26:36.802 READ DMA
|
||||
|
||||
Error 18 [17] occurred at disk power-on lifetime: 62221 hours (2592 days + 13 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER -- ST COUNT LBA_48 LH LM LL DV DC
|
||||
-- -- -- == -- == == == -- -- -- -- --
|
||||
40 -- 51 00 20 00 00 00 77 b8 4c e1 00 Error: UNC 32 sectors at LBA = 0x0177b84c = 24623180
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
|
||||
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
|
||||
c8 00 00 00 20 00 00 01 77 b8 3f e1 02 02:26:40.398 READ DMA
|
||||
c8 00 00 00 20 00 00 01 77 b8 3f e1 02 02:26:38.609 READ DMA
|
||||
c8 00 00 00 20 00 00 01 77 b8 3f e1 02 02:26:36.816 READ DMA
|
||||
c8 00 00 00 20 00 00 01 06 2b 7f e1 02 02:26:36.802 READ DMA
|
||||
ca 00 00 00 01 00 00 03 80 35 af e3 02 02:26:34.048 WRITE DMA
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 2
|
||||
SCT Version (vendor specific): 258 (0x0102)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 44 Celsius
|
||||
Power Cycle Min/Max Temperature: 28/48 Celsius
|
||||
Lifetime Min/Max Temperature: 44/61 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/60 Celsius
|
||||
Min/Max Temperature Limit: -41/85 Celsius
|
||||
Temperature History Size (Index): 478 (273)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP/SMART Log 0x04) not supported
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x0002 2 0 R_ERR response for data FIS
|
||||
0x0003 2 0 R_ERR response for device-to-host data FIS
|
||||
0x0004 2 0 R_ERR response for host-to-device data FIS
|
||||
0x0005 2 0 R_ERR response for non-data FIS
|
||||
0x0006 2 0 R_ERR response for device-to-host non-data FIS
|
||||
0x0007 2 0 R_ERR response for host-to-device non-data FIS
|
||||
0x000a 2 7 Device-to-host register FISes sent due to a COMRESET
|
||||
0x000b 2 0 CRC errors within host-to-device FIS
|
||||
0x8000 4 613126 Vendor specific
|
||||
|
||||
|
||||
|
Reference in New Issue