smartctl 7.4 2023-08-01 r5530 [DragonFly 6.4-RELEASE x86_64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Device Model: WDC WD200EDGZ-11BLDS0
Serial Number: --
LU WWN Device Id: 5 000cca ...
Firmware Version: 85.00A85
User Capacity: 20,000,588,955,648 bytes [20.0 TB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 7200 rpm
Form Factor: 3.5 inches
Device is: Not in smartctl database 7.3/5528
ATA Version is: ACS-5 (minor revision not indicated)
SATA Version is: SATA 3.5, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Mon Sep 2 16:03:38 2024 BST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART Status not supported: Incomplete response, ATA output registers missing
SMART overall-health self-assessment test result: PASSED
Warning: This result is based on an Attribute check.
General SMART Values:
Offline data collection status: (0x82) Offline data collection activity
was completed without error.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 101) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: (2157) minutes.
SCT capabilities: (0x003d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000b 100 100 001 Pre-fail Always - 0
2 Throughput_Performance 0x0004 146 146 054 Old_age Offline - 57
3 Spin_Up_Time 0x0007 084 084 001 Pre-fail Always - 370 (Average 311)
4 Start_Stop_Count 0x0012 100 100 000 Old_age Always - 45
5 Reallocated_Sector_Ct 0x0033 100 100 001 Pre-fail Always - 0
7 Seek_Error_Rate 0x000a 100 100 001 Old_age Always - 0
8 Seek_Time_Performance 0x0004 140 140 020 Old_age Offline - 15
9 Power_On_Hours 0x0012 100 100 000 Old_age Always - 5721
10 Spin_Retry_Count 0x0012 100 100 001 Old_age Always - 0
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 44
22 Unknown_Attribute 0x0023 100 100 025 Pre-fail Always - 6553700
90 Unknown_Attribute 0x0031 100 100 001 Pre-fail Offline - 300647710720
192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 230
193 Load_Cycle_Count 0x0012 100 100 000 Old_age Always - 230
194 Temperature_Celsius 0x0002 051 051 000 Old_age Always - 33 (Min/Max 11/54)
196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 0
197 Current_Pending_Sector 0x0022 100 100 000 Old_age Always - 0
198 Offline_Uncorrectable 0x0008 100 100 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x000a 100 100 000 Old_age Always - 0
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
The above only provides legacy SMART information - try 'smartctl -x' for more