mirror of
https://github.com/bsdhw/SMART.git
synced 2025-05-31 16:21:41 +05:30
Update of reports (new: 6895, modified: 16)
This commit is contained in:
67
NVMe/KIOXIA/KBG30/KBG30ZMV128G/AAC62D0656AF
Normal file
67
NVMe/KIOXIA/KBG30/KBG30ZMV128G/AAC62D0656AF
Normal file
@@ -0,0 +1,67 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p5 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Number: KBG30ZMV128G KIOXIA
|
||||
Serial Number: --
|
||||
Firmware Version: ADHA0102
|
||||
PCI Vendor/Subsystem ID: 0x1179
|
||||
IEEE OUI Identifier: 0x00080d
|
||||
Controller ID: 0
|
||||
NVMe Version: 1.2.1
|
||||
Number of Namespaces: 1
|
||||
Namespace 1 Size/Capacity: 128,035,676,160 [128 GB]
|
||||
Namespace 1 Formatted LBA Size: 512
|
||||
Namespace 1 IEEE EUI-64: 00080d ...
|
||||
Local Time is: Tue Nov 21 00:26:35 2023 CET
|
||||
Firmware Updates (0x12): 1 Slot, no Reset required
|
||||
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
|
||||
Optional NVM Commands (0x0017): Comp Wr_Unc DS_Mngmt Sav/Sel_Feat
|
||||
Log Page Attributes (0x02): Cmd_Eff_Lg
|
||||
Maximum Data Transfer Size: 512 Pages
|
||||
Warning Comp. Temp. Threshold: 82 Celsius
|
||||
Critical Comp. Temp. Threshold: 85 Celsius
|
||||
|
||||
Supported Power States
|
||||
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
|
||||
0 + 3.20W - - 0 0 0 0 0 0
|
||||
1 + 2.70W - - 1 1 1 1 0 0
|
||||
2 + 2.20W - - 2 2 2 2 0 0
|
||||
3 - 0.0500W - - 4 4 4 4 8000 32000
|
||||
4 - 0.0050W - - 4 4 4 4 8000 40000
|
||||
|
||||
Supported LBA Sizes (NSID 0x1)
|
||||
Id Fmt Data Metadt Rel_Perf
|
||||
0 - 4096 0 0
|
||||
1 + 512 0 3
|
||||
|
||||
=== START OF SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
SMART/Health Information (NVMe Log 0x02)
|
||||
Critical Warning: 0x00
|
||||
Temperature: 45 Celsius
|
||||
Available Spare: 100%
|
||||
Available Spare Threshold: 10%
|
||||
Percentage Used: 30%
|
||||
Data Units Read: 240,001 [122 GB]
|
||||
Data Units Written: 53,106,594 [27.1 TB]
|
||||
Host Read Commands: 6,901,125
|
||||
Host Write Commands: 674,794,093
|
||||
Controller Busy Time: 1,274
|
||||
Power Cycles: 105
|
||||
Power On Hours: 21,844
|
||||
Unsafe Shutdowns: 71
|
||||
Media and Data Integrity Errors: 0
|
||||
Error Information Log Entries: 18,812
|
||||
Warning Comp. Temperature Time: 0
|
||||
Critical Comp. Temperature Time: 0
|
||||
Temperature Sensor 1: 45 Celsius
|
||||
|
||||
Error Information (NVMe Log 0x01, 16 of 64 entries)
|
||||
No Errors Logged
|
||||
|
||||
Self-test Log (NVMe Log 0x06)
|
||||
Self-test status: No self-test in progress
|
||||
No Self-tests Logged
|
||||
|
Reference in New Issue