mirror of
https://github.com/bsdhw/SMART.git
synced 2025-05-31 16:21:41 +05:30
Update of reports (new: 6895, modified: 16)
This commit is contained in:
69
NVMe/KIOXIA/KBG40/KBG40ZNS256G NVMe 256GB/C34E1CBED5A1
Normal file
69
NVMe/KIOXIA/KBG40/KBG40ZNS256G NVMe 256GB/C34E1CBED5A1
Normal file
@@ -0,0 +1,69 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Number: KBG40ZNS256G NVMe KIOXIA 256GB
|
||||
Serial Number: --
|
||||
Firmware Version: 10410106
|
||||
PCI Vendor/Subsystem ID: 0x1e0f
|
||||
IEEE OUI Identifier: 0x8ce38e
|
||||
Total NVM Capacity: 256,060,514,304 [256 GB]
|
||||
Unallocated NVM Capacity: 0
|
||||
Controller ID: 0
|
||||
NVMe Version: 1.3
|
||||
Number of Namespaces: 1
|
||||
Namespace 1 Size/Capacity: 256,060,514,304 [256 GB]
|
||||
Namespace 1 Formatted LBA Size: 512
|
||||
Namespace 1 IEEE EUI-64: 8ce38e ...
|
||||
Local Time is: Thu Jun 8 00:45:47 2023 EDT
|
||||
Firmware Updates (0x14): 2 Slots, no Reset required
|
||||
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
|
||||
Optional NVM Commands (0x005f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
|
||||
Log Page Attributes (0x0e): Cmd_Eff_Lg Ext_Get_Lg Telmtry_Lg
|
||||
Maximum Data Transfer Size: 512 Pages
|
||||
Warning Comp. Temp. Threshold: 83 Celsius
|
||||
Critical Comp. Temp. Threshold: 87 Celsius
|
||||
|
||||
Supported Power States
|
||||
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
|
||||
0 + 3.60W - - 0 0 0 0 1 1
|
||||
1 + 2.60W - - 1 1 1 1 1 1
|
||||
2 + 2.20W - - 2 2 2 2 1 1
|
||||
3 - 0.0500W - - 3 3 3 3 800 1200
|
||||
4 - 0.0050W - - 4 4 4 4 3000 32000
|
||||
|
||||
Supported LBA Sizes (NSID 0x1)
|
||||
Id Fmt Data Metadt Rel_Perf
|
||||
0 + 512 0 3
|
||||
1 - 4096 0 1
|
||||
|
||||
=== START OF SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
SMART/Health Information (NVMe Log 0x02)
|
||||
Critical Warning: 0x00
|
||||
Temperature: 42 Celsius
|
||||
Available Spare: 100%
|
||||
Available Spare Threshold: 50%
|
||||
Percentage Used: 14%
|
||||
Data Units Read: 117,711,947 [60.2 TB]
|
||||
Data Units Written: 42,911,509 [21.9 TB]
|
||||
Host Read Commands: 1,033,367,129
|
||||
Host Write Commands: 559,778,192
|
||||
Controller Busy Time: 5,395
|
||||
Power Cycles: 1,394
|
||||
Power On Hours: 8,603
|
||||
Unsafe Shutdowns: 469
|
||||
Media and Data Integrity Errors: 0
|
||||
Error Information Log Entries: 0
|
||||
Warning Comp. Temperature Time: 3
|
||||
Critical Comp. Temperature Time: 0
|
||||
Temperature Sensor 1: 42 Celsius
|
||||
Thermal Temp. 1 Transition Count: 614
|
||||
Thermal Temp. 2 Transition Count: 265
|
||||
Thermal Temp. 1 Total Time: 1850
|
||||
Thermal Temp. 2 Total Time: 4265
|
||||
|
||||
Error Information (NVMe Log 0x01, 16 of 256 entries)
|
||||
No Errors Logged
|
||||
|
68
NVMe/KIOXIA/KBG40/KBG40ZNS256G NVMe 256GB/ED8EE60C989C
Normal file
68
NVMe/KIOXIA/KBG40/KBG40ZNS256G NVMe 256GB/ED8EE60C989C
Normal file
@@ -0,0 +1,68 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [OpenBSD 7.6 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Number: KBG40ZNS256G NVMe KIOXIA 256GB
|
||||
Serial Number: --
|
||||
Firmware Version: 10410105
|
||||
PCI Vendor/Subsystem ID: 0x1e0f
|
||||
IEEE OUI Identifier: 0x8ce38e
|
||||
Total NVM Capacity: 256,060,514,304 [256 GB]
|
||||
Unallocated NVM Capacity: 0
|
||||
Controller ID: 0
|
||||
NVMe Version: 1.3
|
||||
Number of Namespaces: 1
|
||||
Local Time is: Sun Dec 8 18:46:20 2024 -07
|
||||
Firmware Updates (0x14): 2 Slots, no Reset required
|
||||
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
|
||||
Optional NVM Commands (0x005f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
|
||||
Log Page Attributes (0x0e): Cmd_Eff_Lg Ext_Get_Lg Telmtry_Lg
|
||||
Maximum Data Transfer Size: 512 Pages
|
||||
Warning Comp. Temp. Threshold: 83 Celsius
|
||||
Critical Comp. Temp. Threshold: 87 Celsius
|
||||
|
||||
Supported Power States
|
||||
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
|
||||
0 + 3.60W - - 0 0 0 0 1 1
|
||||
1 + 2.60W - - 1 1 1 1 1 1
|
||||
2 + 2.20W - - 2 2 2 2 1 1
|
||||
3 - 0.0500W - - 3 3 3 3 800 1200
|
||||
4 - 0.0050W - - 4 4 4 4 3000 32000
|
||||
|
||||
=== START OF SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
SMART/Health Information (NVMe Log 0x02)
|
||||
Critical Warning: 0x00
|
||||
Temperature: 39 Celsius
|
||||
Available Spare: 100%
|
||||
Available Spare Threshold: 50%
|
||||
Percentage Used: 0%
|
||||
Data Units Read: 529,823 [271 GB]
|
||||
Data Units Written: 680,541 [348 GB]
|
||||
Host Read Commands: 7,260,148
|
||||
Host Write Commands: 8,220,244
|
||||
Controller Busy Time: 24
|
||||
Power Cycles: 68
|
||||
Power On Hours: 153
|
||||
Unsafe Shutdowns: 18
|
||||
Media and Data Integrity Errors: 0
|
||||
Error Information Log Entries: 0
|
||||
Warning Comp. Temperature Time: 0
|
||||
Critical Comp. Temperature Time: 0
|
||||
Temperature Sensor 1: 39 Celsius
|
||||
|
||||
Error Information (NVMe Log 0x01, 16 of 256 entries)
|
||||
No Errors Logged
|
||||
|
||||
Self-test Log (NVMe Log 0x06)
|
||||
Self-test status: No self-test in progress
|
||||
Num Test_Description Status Power_on_Hours Failing_LBA NSID Seg SCT Code
|
||||
0 Short Completed without error 147 - - - - -
|
||||
1 Short Aborted: Controller Reset 146 - - - - -
|
||||
2 Short Completed without error 143 - - - - -
|
||||
3 Short Completed without error 143 - - - - -
|
||||
4 Short Completed without error 1 - - - - -
|
||||
|
||||
|
||||
|
72
NVMe/KIOXIA/KBG40/KBG40ZNV256G/A2235A98213B
Normal file
72
NVMe/KIOXIA/KBG40/KBG40ZNV256G/A2235A98213B
Normal file
@@ -0,0 +1,72 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p9 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Number: KBG40ZNV256G KIOXIA
|
||||
Serial Number: --
|
||||
Firmware Version: HP01AE00
|
||||
PCI Vendor/Subsystem ID: 0x1e0f
|
||||
IEEE OUI Identifier: 0x8ce38e
|
||||
Total NVM Capacity: 256,060,514,304 [256 GB]
|
||||
Unallocated NVM Capacity: 0
|
||||
Controller ID: 0
|
||||
NVMe Version: 1.3
|
||||
Number of Namespaces: 1
|
||||
Namespace 1 Size/Capacity: 256,060,514,304 [256 GB]
|
||||
Namespace 1 Formatted LBA Size: 512
|
||||
Namespace 1 IEEE EUI-64: 8ce38e ...
|
||||
Local Time is: Fri Feb 2 18:14:26 2024 CST
|
||||
Firmware Updates (0x14): 2 Slots, no Reset required
|
||||
Optional Admin Commands (0x001f): Security Format Frmw_DL NS_Mngmt Self_Test
|
||||
Optional NVM Commands (0x005f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
|
||||
Log Page Attributes (0x0e): Cmd_Eff_Lg Ext_Get_Lg Telmtry_Lg
|
||||
Maximum Data Transfer Size: 512 Pages
|
||||
Warning Comp. Temp. Threshold: 79 Celsius
|
||||
Critical Comp. Temp. Threshold: 84 Celsius
|
||||
|
||||
Supported Power States
|
||||
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
|
||||
0 + 3.60W - - 0 0 0 0 1 1
|
||||
1 + 2.60W - - 1 1 1 1 1 1
|
||||
2 + 1.80W - - 2 2 2 2 1 1
|
||||
3 - 0.0500W - - 4 4 4 4 800 1200
|
||||
4 - 0.0050W - - 4 4 4 4 3000 32000
|
||||
|
||||
Supported LBA Sizes (NSID 0x1)
|
||||
Id Fmt Data Metadt Rel_Perf
|
||||
0 + 512 0 3
|
||||
1 - 4096 0 1
|
||||
|
||||
=== START OF SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
SMART/Health Information (NVMe Log 0x02)
|
||||
Critical Warning: 0x00
|
||||
Temperature: 59 Celsius
|
||||
Available Spare: 100%
|
||||
Available Spare Threshold: 5%
|
||||
Percentage Used: 14%
|
||||
Data Units Read: 32,468,225 [16.6 TB]
|
||||
Data Units Written: 28,895,494 [14.7 TB]
|
||||
Host Read Commands: 459,195,271
|
||||
Host Write Commands: 430,018,895
|
||||
Controller Busy Time: 2,275
|
||||
Power Cycles: 116,399
|
||||
Power On Hours: 3,087
|
||||
Unsafe Shutdowns: 11
|
||||
Media and Data Integrity Errors: 0
|
||||
Error Information Log Entries: 9
|
||||
Warning Comp. Temperature Time: 0
|
||||
Critical Comp. Temperature Time: 0
|
||||
Temperature Sensor 1: 59 Celsius
|
||||
|
||||
Error Information (NVMe Log 0x01, 16 of 256 entries)
|
||||
No Errors Logged
|
||||
|
||||
Self-test Log (NVMe Log 0x06)
|
||||
Self-test status: No self-test in progress
|
||||
Num Test_Description Status Power_on_Hours Failing_LBA NSID Seg SCT Code
|
||||
0 Extended Completed without error 2995 - - - - -
|
||||
1 Short Completed without error 2994 - - - - -
|
||||
2 Short Completed without error 2994 - - - - -
|
||||
|
65
NVMe/KIOXIA/KBG40/KBG40ZNV512G/A50D12F53291
Normal file
65
NVMe/KIOXIA/KBG40/KBG40ZNV512G/A50D12F53291
Normal file
@@ -0,0 +1,65 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Number: KBG40ZNV512G KIOXIA
|
||||
Serial Number: --
|
||||
Firmware Version: HP01AE00
|
||||
PCI Vendor/Subsystem ID: 0x1e0f
|
||||
IEEE OUI Identifier: 0x8ce38e
|
||||
Total NVM Capacity: 512,110,190,592 [512 GB]
|
||||
Unallocated NVM Capacity: 0
|
||||
Controller ID: 0
|
||||
NVMe Version: 1.3
|
||||
Number of Namespaces: 1
|
||||
Namespace 1 Size/Capacity: 512,110,190,592 [512 GB]
|
||||
Namespace 1 Formatted LBA Size: 512
|
||||
Namespace 1 IEEE EUI-64: 8ce38e ...
|
||||
Local Time is: Tue Jul 16 01:31:05 2024 UTC
|
||||
Firmware Updates (0x14): 2 Slots, no Reset required
|
||||
Optional Admin Commands (0x001f): Security Format Frmw_DL NS_Mngmt Self_Test
|
||||
Optional NVM Commands (0x005f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
|
||||
Log Page Attributes (0x0e): Cmd_Eff_Lg Ext_Get_Lg Telmtry_Lg
|
||||
Maximum Data Transfer Size: 512 Pages
|
||||
Warning Comp. Temp. Threshold: 79 Celsius
|
||||
Critical Comp. Temp. Threshold: 84 Celsius
|
||||
|
||||
Supported Power States
|
||||
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
|
||||
0 + 3.50W - - 0 0 0 0 1 1
|
||||
1 + 2.60W - - 1 1 1 1 1 1
|
||||
2 + 1.80W - - 2 2 2 2 1 1
|
||||
3 - 0.0500W - - 4 4 4 4 800 1200
|
||||
4 - 0.0050W - - 4 4 4 4 3000 32000
|
||||
|
||||
Supported LBA Sizes (NSID 0x1)
|
||||
Id Fmt Data Metadt Rel_Perf
|
||||
0 + 512 0 3
|
||||
1 - 4096 0 1
|
||||
|
||||
=== START OF SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
SMART/Health Information (NVMe Log 0x02)
|
||||
Critical Warning: 0x00
|
||||
Temperature: 42 Celsius
|
||||
Available Spare: 100%
|
||||
Available Spare Threshold: 5%
|
||||
Percentage Used: 9%
|
||||
Data Units Read: 83,004,388 [42.4 TB]
|
||||
Data Units Written: 45,433,023 [23.2 TB]
|
||||
Host Read Commands: 750,296,199
|
||||
Host Write Commands: 635,787,247
|
||||
Controller Busy Time: 4,422
|
||||
Power Cycles: 3,014
|
||||
Power On Hours: 5,998
|
||||
Unsafe Shutdowns: 320
|
||||
Media and Data Integrity Errors: 0
|
||||
Error Information Log Entries: 0
|
||||
Warning Comp. Temperature Time: 0
|
||||
Critical Comp. Temperature Time: 0
|
||||
Temperature Sensor 1: 42 Celsius
|
||||
|
||||
Error Information (NVMe Log 0x01, 16 of 256 entries)
|
||||
No Errors Logged
|
||||
|
65
NVMe/KIOXIA/KBG40/KBG40ZPZ128G BG4A/5E9B6DBD5625
Normal file
65
NVMe/KIOXIA/KBG40/KBG40ZPZ128G BG4A/5E9B6DBD5625
Normal file
@@ -0,0 +1,65 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.2-RC6 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Number: KBG40ZPZ128G BG4A KIOXIA
|
||||
Serial Number: --
|
||||
Firmware Version: AEMS0104
|
||||
PCI Vendor/Subsystem ID: 0x1e0f
|
||||
IEEE OUI Identifier: 0x8ce38e
|
||||
Total NVM Capacity: 128,035,676,160 [128 GB]
|
||||
Unallocated NVM Capacity: 0
|
||||
Controller ID: 0
|
||||
NVMe Version: 1.3
|
||||
Number of Namespaces: 1
|
||||
Namespace 1 Size/Capacity: 128,035,676,160 [128 GB]
|
||||
Namespace 1 Formatted LBA Size: 512
|
||||
Namespace 1 IEEE EUI-64: 8ce38e ...
|
||||
Local Time is: Wed May 10 18:24:14 2023 EEST
|
||||
Firmware Updates (0x14): 2 Slots, no Reset required
|
||||
Optional Admin Commands (0x001f): Security Format Frmw_DL NS_Mngmt Self_Test
|
||||
Optional NVM Commands (0x005f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
|
||||
Log Page Attributes (0x0e): Cmd_Eff_Lg Ext_Get_Lg Telmtry_Lg
|
||||
Maximum Data Transfer Size: 512 Pages
|
||||
Warning Comp. Temp. Threshold: 82 Celsius
|
||||
Critical Comp. Temp. Threshold: 86 Celsius
|
||||
|
||||
Supported Power States
|
||||
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
|
||||
0 + 3.00W - - 0 0 0 0 1 1
|
||||
1 + 2.20W - - 1 1 1 1 1 1
|
||||
2 + 1.80W - - 2 2 2 2 1 1
|
||||
3 - 0.0500W - - 4 4 4 4 800 1200
|
||||
4 - 0.0050W - - 4 4 4 4 3000 32000
|
||||
|
||||
Supported LBA Sizes (NSID 0x1)
|
||||
Id Fmt Data Metadt Rel_Perf
|
||||
0 + 512 0 3
|
||||
1 - 4096 0 1
|
||||
|
||||
=== START OF SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
SMART/Health Information (NVMe Log 0x02)
|
||||
Critical Warning: 0x00
|
||||
Temperature: 37 Celsius
|
||||
Available Spare: 100%
|
||||
Available Spare Threshold: 10%
|
||||
Percentage Used: 3%
|
||||
Data Units Read: 1,832,168 [938 GB]
|
||||
Data Units Written: 2,896,172 [1.48 TB]
|
||||
Host Read Commands: 19,068,703
|
||||
Host Write Commands: 31,384,403
|
||||
Controller Busy Time: 481
|
||||
Power Cycles: 275
|
||||
Power On Hours: 4,328
|
||||
Unsafe Shutdowns: 91
|
||||
Media and Data Integrity Errors: 0
|
||||
Error Information Log Entries: 0
|
||||
Warning Comp. Temperature Time: 0
|
||||
Critical Comp. Temperature Time: 0
|
||||
Temperature Sensor 1: 37 Celsius
|
||||
|
||||
Error Information (NVMe Log 0x01, 16 of 256 entries)
|
||||
No Errors Logged
|
||||
|
Reference in New Issue
Block a user