1
0
mirror of https://github.com/bsdhw/SMART.git synced 2025-05-31 16:21:41 +05:30

Update of reports (new: 6895, modified: 16)

This commit is contained in:
Andrey Ponomarenko
2025-01-05 01:57:11 +03:00
parent e3bee1f876
commit 2a811b67c1
6911 changed files with 1114213 additions and 734 deletions

View File

@@ -0,0 +1,68 @@
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p11 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: Phison
Serial Number: --
Firmware Version: ERFM11.0
PCI Vendor/Subsystem ID: 0x1987
IEEE OUI Identifier: 0x6479a7
Controller ID: 0
NVMe Version: 1.4
Number of Namespaces: 1
Namespace 1 Size/Capacity: 1,024,209,543,168 [1.02 TB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Sat Jun 1 17:09:51 2024 JST
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x0056): Wr_Unc DS_Mngmt Sav/Sel_Feat Timestmp
Log Page Attributes (0x1e): Cmd_Eff_Lg Ext_Get_Lg Telmtry_Lg Pers_Ev_Lg
Maximum Data Transfer Size: 64 Pages
Warning Comp. Temp. Threshold: 83 Celsius
Critical Comp. Temp. Threshold: 85 Celsius
Namespace 1 Features (0x08): No_ID_Reuse
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 5.70W - - 0 0 0 0 0 0
1 + 3.00W - - 1 1 1 1 0 0
2 + 1.80W - - 2 2 2 2 0 0
3 - 0.0500W - - 3 3 3 3 5000 2500
4 - 0.0050W - - 4 4 4 4 8000 40000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 1
1 - 4096 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 40 Celsius
Available Spare: 100%
Available Spare Threshold: 5%
Percentage Used: 0%
Data Units Read: 35,470 [18.1 GB]
Data Units Written: 107,510 [55.0 GB]
Host Read Commands: 638,168
Host Write Commands: 1,652,965
Controller Busy Time: 2
Power Cycles: 30
Power On Hours: 94
Unsafe Shutdowns: 12
Media and Data Integrity Errors: 0
Error Information Log Entries: 0
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 40 Celsius
Error Information (NVMe Log 0x01, 16 of 255 entries)
No Errors Logged
Self-test Log (NVMe Log 0x06)
Self-test status: No self-test in progress
No Self-tests Logged

View File

@@ -0,0 +1,64 @@
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: 256GB NVMe SSD
Serial Number: --
Firmware Version: APB06PP0
PCI Vendor/Subsystem ID: 0x1987
IEEE OUI Identifier: 0x6479a7
Total NVM Capacity: 256,060,514,304 [256 GB]
Unallocated NVM Capacity: 0
Controller ID: 0
NVMe Version: 1.4
Number of Namespaces: 1
Namespace 1 Size/Capacity: 256,060,514,304 [256 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Sun Feb 15 11:39:54 2099 CST
Firmware Updates (0x14): 2 Slots, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x1e): Cmd_Eff_Lg Ext_Get_Lg Telmtry_Lg Pers_Ev_Lg
Maximum Data Transfer Size: 64 Pages
Warning Comp. Temp. Threshold: 83 Celsius
Critical Comp. Temp. Threshold: 85 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 5.00W - - 0 0 0 0 0 0
1 + 2.40W - - 1 1 1 1 0 0
2 + 1.92W - - 2 2 2 2 0 0
3 - 0.0700W - - 3 3 3 3 5000 10000
4 - 0.0050W - - 4 4 4 4 6000 44000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 1
1 - 4096 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 31 Celsius
Available Spare: 100%
Available Spare Threshold: 5%
Percentage Used: 0%
Data Units Read: 1,020,419,542 [522 TB]
Data Units Written: 262,289 [134 GB]
Host Read Commands: 1,993,821,009
Host Write Commands: 1,626,233
Controller Busy Time: 2,641
Power Cycles: 456
Power On Hours: 618
Unsafe Shutdowns: 64
Media and Data Integrity Errors: 0
Error Information Log Entries: 0
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Error Information (NVMe Log 0x01, 16 of 63 entries)
No Errors Logged

View File

@@ -0,0 +1,65 @@
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: 311CD0512GB
Serial Number: --
Firmware Version: EDFOB0.6
PCI Vendor/Subsystem ID: 0x1987
IEEE OUI Identifier: 0x6479a7
Total NVM Capacity: 512,110,190,592 [512 GB]
Unallocated NVM Capacity: 0
Controller ID: 1
NVMe Version: 1.3
Number of Namespaces: 1
Namespace 1 Size/Capacity: 512,110,190,592 [512 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Fri Jun 16 04:26:37 2023 UTC
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005e): Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x0a): Cmd_Eff_Lg Telmtry_Lg
Maximum Data Transfer Size: 64 Pages
Warning Comp. Temp. Threshold: 70 Celsius
Critical Comp. Temp. Threshold: 85 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 4.50W - - 0 0 0 0 0 0
1 + 2.70W - - 1 1 1 1 0 0
2 + 2.16W - - 2 2 2 2 0 0
3 - 0.0700W - - 3 3 3 3 1000 1000
4 - 0.0050W - - 4 4 4 4 5000 45000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 1
1 - 4096 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 32 Celsius
Available Spare: 100%
Available Spare Threshold: 5%
Percentage Used: 2%
Data Units Read: 25,891,259 [13.2 TB]
Data Units Written: 19,332,464 [9.89 TB]
Host Read Commands: 301,913,140
Host Write Commands: 267,636,754
Controller Busy Time: 1,975
Power Cycles: 2,117
Power On Hours: 3,697
Unsafe Shutdowns: 47
Media and Data Integrity Errors: 0
Error Information Log Entries: 3,930
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 48 Celsius
Error Information (NVMe Log 0x01, 16 of 16 entries)
No Errors Logged

View File

@@ -0,0 +1,64 @@
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.2-RELEASE amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: E18-1TB-PHISON-SSD-B47R
Serial Number: --
Firmware Version: EIOM31.4
PCI Vendor/Subsystem ID: 0x1987
IEEE OUI Identifier: 0x6479a7
Total NVM Capacity: 1,024,209,543,168 [1.02 TB]
Unallocated NVM Capacity: 0
Controller ID: 1
NVMe Version: 1.4
Number of Namespaces: 1
Namespace 1 Size/Capacity: 1,024,209,543,168 [1.02 TB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Wed May 10 20:04:12 2023 CEST
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005d): Comp DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x08): Telmtry_Lg
Maximum Data Transfer Size: 512 Pages
Warning Comp. Temp. Threshold: 84 Celsius
Critical Comp. Temp. Threshold: 89 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 8.80W - - 0 0 0 0 0 0
1 + 7.10W - - 1 1 1 1 0 0
2 + 5.20W - - 2 2 2 2 0 0
3 - 0.0620W - - 3 3 3 3 2500 7500
4 - 0.0440W - - 4 4 4 4 10500 65000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 2
1 - 4096 0 1
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 40 Celsius
Available Spare: 100%
Available Spare Threshold: 5%
Percentage Used: 1%
Data Units Read: 1,381,792 [707 GB]
Data Units Written: 5,924,686 [3.03 TB]
Host Read Commands: 8,401,077
Host Write Commands: 177,495,418
Controller Busy Time: 2,636
Power Cycles: 1,056
Power On Hours: 1,485
Unsafe Shutdowns: 27
Media and Data Integrity Errors: 0
Error Information Log Entries: 4,351
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Error Information (NVMe Log 0x01, 16 of 63 entries)
No Errors Logged

View File

@@ -0,0 +1,69 @@
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-STABLE amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: ESO512GTLCW-EP3-2L
Serial Number: --
Firmware Version: EDFMG1.5
PCI Vendor/Subsystem ID: 0x1987
IEEE OUI Identifier: 0x6479a7
Total NVM Capacity: 512,110,190,592 [512 GB]
Unallocated NVM Capacity: 0
Controller ID: 1
NVMe Version: 1.3
Number of Namespaces: 1
Namespace 1 Size/Capacity: 512,110,190,592 [512 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Mon Feb 12 10:53:18 2024 CET
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x0056): Wr_Unc DS_Mngmt Sav/Sel_Feat Timestmp
Log Page Attributes (0x0a): Cmd_Eff_Lg Telmtry_Lg
Maximum Data Transfer Size: 64 Pages
Warning Comp. Temp. Threshold: 85 Celsius
Critical Comp. Temp. Threshold: 95 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 4.50W - - 0 0 0 0 0 0
1 + 2.70W - - 1 1 1 1 0 0
2 + 2.16W - - 2 2 2 2 0 0
3 - 0.0700W - - 3 3 3 3 1000 1000
4 - 0.0050W - - 4 4 4 4 5000 50000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 1
1 - 4096 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 34 Celsius
Available Spare: 100%
Available Spare Threshold: 5%
Percentage Used: 0%
Data Units Read: 764,241 [391 GB]
Data Units Written: 5,328,390 [2.72 TB]
Host Read Commands: 6,965,646
Host Write Commands: 148,331,534
Controller Busy Time: 109
Power Cycles: 149
Power On Hours: 1,889
Unsafe Shutdowns: 4
Media and Data Integrity Errors: 0
Error Information Log Entries: 1
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 48 Celsius
Error Information (NVMe Log 0x01, 16 of 16 entries)
No Errors Logged
Self-test Log (NVMe Log 0x06)
Self-test status: No self-test in progress
No Self-tests Logged

View File

@@ -0,0 +1,69 @@
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p3 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: ESO512GYLCT-EP3-2L
Serial Number: --
Firmware Version: EDFME0.1
PCI Vendor/Subsystem ID: 0x1987
IEEE OUI Identifier: 0x6479a7
Total NVM Capacity: 512,110,190,592 [512 GB]
Unallocated NVM Capacity: 0
Controller ID: 1
NVMe Version: 1.3
Number of Namespaces: 1
Namespace 1 Size/Capacity: 512,110,190,592 [512 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Wed Oct 18 19:11:30 2023 BST
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005e): Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x0a): Cmd_Eff_Lg Telmtry_Lg
Maximum Data Transfer Size: 64 Pages
Warning Comp. Temp. Threshold: 70 Celsius
Critical Comp. Temp. Threshold: 80 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 4.50W - - 0 0 0 0 0 0
1 + 2.70W - - 1 1 1 1 0 0
2 + 2.16W - - 2 2 2 2 0 0
3 - 0.0700W - - 3 3 3 3 1000 1000
4 - 0.0050W - - 4 4 4 4 5000 50000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 1
1 - 4096 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 36 Celsius
Available Spare: 100%
Available Spare Threshold: 5%
Percentage Used: 0%
Data Units Read: 2,723,517 [1.39 TB]
Data Units Written: 3,043,070 [1.55 TB]
Host Read Commands: 23,648,838
Host Write Commands: 25,464,022
Controller Busy Time: 107
Power Cycles: 68
Power On Hours: 66
Unsafe Shutdowns: 18
Media and Data Integrity Errors: 0
Error Information Log Entries: 0
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 51 Celsius
Error Information (NVMe Log 0x01, 16 of 16 entries)
No Errors Logged
Self-test Log (NVMe Log 0x06)
Self-test status: No self-test in progress
No Self-tests Logged

View File

@@ -0,0 +1,83 @@
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p9 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: Kodilx SSD
Serial Number: --
Firmware Version: E8FM12.2
PCI Vendor/Subsystem ID: 0x1987
IEEE OUI Identifier: 0x6479a7
Total NVM Capacity: 128,035,676,160 [128 GB]
Unallocated NVM Capacity: 0
Controller ID: 0
NVMe Version: 1.2
Number of Namespaces: 1
Namespace 1 Size/Capacity: 128,035,676,160 [128 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Sun Feb 4 02:47:35 2024 EST
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0007): Security Format Frmw_DL
Optional NVM Commands (0x001e): Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat
Log Page Attributes (0x04): Ext_Get_Lg
Maximum Data Transfer Size: 512 Pages
Warning Comp. Temp. Threshold: 86 Celsius
Critical Comp. Temp. Threshold: 90 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 3.00W - - 0 0 0 0 0 0
1 + 2.00W - - 1 1 1 1 0 0
2 + 2.00W - - 2 2 2 2 0 0
3 - 0.1000W - - 3 3 3 3 1000 1000
4 - 0.0050W - - 4 4 4 4 400000 90000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 1
1 - 4096 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 52 Celsius
Available Spare: 100%
Available Spare Threshold: 50%
Percentage Used: 5%
Data Units Read: 488,597 [250 GB]
Data Units Written: 12,709,835 [6.50 TB]
Host Read Commands: 8,242,154
Host Write Commands: 174,421,038
Controller Busy Time: 341
Power Cycles: 163
Power On Hours: 22,369
Unsafe Shutdowns: 115
Media and Data Integrity Errors: 0
Error Information Log Entries: 102
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 2: 52 Celsius
Error Information (NVMe Log 0x01, 16 of 16 entries)
Num ErrCount SQId CmdId Status PELoc LBA NSID VS Message
0 102 0 0x0013 0x0005 - 33555712 0 - Invalid Field in Command
1 101 0 0x100a 0x0005 - 8 0 - Invalid Field in Command
2 100 0 0x1009 0x0005 - 0 0 - Invalid Field in Command
3 99 0 0x1012 0x0005 - 8 0 - Invalid Field in Command
4 98 0 0x1011 0x0005 - 0 0 - Invalid Field in Command
5 97 0 0x1001 0x0005 - 8 0 - Invalid Field in Command
6 96 0 0x1000 0x0005 - 0 0 - Invalid Field in Command
7 95 0 0x1011 0x0005 - 8 0 - Invalid Field in Command
8 94 0 0x1010 0x0005 - 0 0 - Invalid Field in Command
9 93 0 0x1016 0x0005 - 8 0 - Invalid Field in Command
10 92 0 0x1015 0x0005 - 0 0 - Invalid Field in Command
11 91 0 0x1012 0x0005 - 8 0 - Invalid Field in Command
12 90 0 0x1011 0x0005 - 0 0 - Invalid Field in Command
13 89 0 0x101c 0x0005 - 8 0 - Invalid Field in Command
14 88 0 0x1019 0x0005 - 0 0 - Invalid Field in Command
15 87 0 0x0007 0x0005 - 33555456 0 - Invalid Field in Command
Self-tests not supported

View File

@@ -0,0 +1,69 @@
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p3 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: PCIe SSD
Serial Number: --
Firmware Version: EHFM90.1
PCI Vendor/Subsystem ID: 0x1987
IEEE OUI Identifier: 0x6479a7
Total NVM Capacity: 512,110,190,592 [512 GB]
Unallocated NVM Capacity: 0
Controller ID: 0
NVMe Version: 1.4
Number of Namespaces: 1
Namespace 1 Size/Capacity: 512,110,190,592 [512 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Mon Oct 23 06:30:40 2023 CEST
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x1e): Cmd_Eff_Lg Ext_Get_Lg Telmtry_Lg Pers_Ev_Lg
Maximum Data Transfer Size: 64 Pages
Warning Comp. Temp. Threshold: 83 Celsius
Critical Comp. Temp. Threshold: 85 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 5.00W 5.00W - 0 0 0 0 0 0
1 + 2.40W 2.50W - 1 1 1 1 0 1000
2 + 1.90W 1.80W - 2 2 2 2 0 0
3 - 0.0500W - - 3 3 3 3 5000 10000
4 - 0.0050W - - 4 4 4 4 10000 45000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 1
1 - 4096 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 44 Celsius
Available Spare: 100%
Available Spare Threshold: 50%
Percentage Used: 0%
Data Units Read: 1,640,527 [839 GB]
Data Units Written: 1,913,888 [979 GB]
Host Read Commands: 5,550,174
Host Write Commands: 8,485,175
Controller Busy Time: 72
Power Cycles: 67
Power On Hours: 40
Unsafe Shutdowns: 40
Media and Data Integrity Errors: 0
Error Information Log Entries: 135
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 63 Celsius
Error Information (NVMe Log 0x01, 16 of 63 entries)
No Errors Logged
Self-test Log (NVMe Log 0x06)
Self-test status: No self-test in progress
No Self-tests Logged

View File

@@ -0,0 +1,68 @@
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p11 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: PCIe SSD
Serial Number: --
Firmware Version: EHFM32.1
PCI Vendor/Subsystem ID: 0x1987
IEEE OUI Identifier: 0x6479a7
Controller ID: 0
NVMe Version: 1.4
Number of Namespaces: 1
Namespace 1 Size/Capacity: 250,059,350,016 [250 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Wed May 8 13:34:55 2024 EDT
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x1e): Cmd_Eff_Lg Ext_Get_Lg Telmtry_Lg Pers_Ev_Lg
Maximum Data Transfer Size: 64 Pages
Warning Comp. Temp. Threshold: 84 Celsius
Critical Comp. Temp. Threshold: 88 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 5.00W - - 0 0 0 0 0 0
1 + 2.40W - - 1 1 1 1 0 0
2 + 1.92W - - 2 2 2 2 0 0
3 - 0.0700W - - 3 3 3 3 1000 1000
4 - 0.0050W - - 4 4 4 4 10000 40000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 1
1 - 4096 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 60 Celsius
Available Spare: 100%
Available Spare Threshold: 5%
Percentage Used: 8%
Data Units Read: 23,034 [11.7 GB]
Data Units Written: 20,751,163 [10.6 TB]
Host Read Commands: 848,858
Host Write Commands: 342,370,602
Controller Busy Time: 1,051
Power Cycles: 9
Power On Hours: 2,471
Unsafe Shutdowns: 6
Media and Data Integrity Errors: 0
Error Information Log Entries: 0
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Thermal Temp. 1 Transition Count: 5
Thermal Temp. 1 Total Time: 249
Error Information (NVMe Log 0x01, 16 of 63 entries)
No Errors Logged
Self-test Log (NVMe Log 0x06)
Self-test status: No self-test in progress
No Self-tests Logged

View File

@@ -0,0 +1,68 @@
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p7 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: PCIe SSD
Serial Number: --
Firmware Version: EHFM32.1
PCI Vendor/Subsystem ID: 0x1987
IEEE OUI Identifier: 0x6479a7
Controller ID: 0
NVMe Version: 1.4
Number of Namespaces: 1
Namespace 1 Size/Capacity: 250,059,350,016 [250 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Sat Dec 30 03:07:58 2023 UTC
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x1e): Cmd_Eff_Lg Ext_Get_Lg Telmtry_Lg Pers_Ev_Lg
Maximum Data Transfer Size: 64 Pages
Warning Comp. Temp. Threshold: 84 Celsius
Critical Comp. Temp. Threshold: 88 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 5.00W - - 0 0 0 0 0 0
1 + 2.40W - - 1 1 1 1 0 0
2 + 1.92W - - 2 2 2 2 0 0
3 - 0.0700W - - 3 3 3 3 1000 1000
4 - 0.0050W - - 4 4 4 4 10000 40000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 1
1 - 4096 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 64 Celsius
Available Spare: 100%
Available Spare Threshold: 5%
Percentage Used: 0%
Data Units Read: 97,528 [49.9 GB]
Data Units Written: 708,293 [362 GB]
Host Read Commands: 3,088,622
Host Write Commands: 60,911,170
Controller Busy Time: 116
Power Cycles: 127
Power On Hours: 586
Unsafe Shutdowns: 92
Media and Data Integrity Errors: 0
Error Information Log Entries: 0
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Error Information (NVMe Log 0x01, 16 of 63 entries)
No Errors Logged
Self-test Log (NVMe Log 0x06)
Self-test status: No self-test in progress
No Self-tests Logged

View File

@@ -0,0 +1,69 @@
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p3 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: PCIe SSD
Serial Number: --
Firmware Version: EHFM90.1
PCI Vendor/Subsystem ID: 0x1987
IEEE OUI Identifier: 0x6479a7
Total NVM Capacity: 512,110,190,592 [512 GB]
Unallocated NVM Capacity: 0
Controller ID: 0
NVMe Version: 1.4
Number of Namespaces: 1
Namespace 1 Size/Capacity: 512,110,190,592 [512 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Mon Oct 9 19:47:23 2023 EDT
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x1e): Cmd_Eff_Lg Ext_Get_Lg Telmtry_Lg Pers_Ev_Lg
Maximum Data Transfer Size: 64 Pages
Warning Comp. Temp. Threshold: 83 Celsius
Critical Comp. Temp. Threshold: 85 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 5.00W 5.00W - 0 0 0 0 0 0
1 + 2.40W 2.50W - 1 1 1 1 0 1000
2 + 1.90W 1.80W - 2 2 2 2 0 0
3 - 0.0500W - - 3 3 3 3 5000 10000
4 - 0.0050W - - 4 4 4 4 10000 45000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 1
1 - 4096 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 35 Celsius
Available Spare: 100%
Available Spare Threshold: 50%
Percentage Used: 0%
Data Units Read: 1,508,104 [772 GB]
Data Units Written: 1,667,046 [853 GB]
Host Read Commands: 3,633,728
Host Write Commands: 5,492,423
Controller Busy Time: 54
Power Cycles: 30
Power On Hours: 86
Unsafe Shutdowns: 10
Media and Data Integrity Errors: 0
Error Information Log Entries: 20
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 52 Celsius
Error Information (NVMe Log 0x01, 16 of 63 entries)
No Errors Logged
Self-test Log (NVMe Log 0x06)
Self-test status: No self-test in progress
No Self-tests Logged

View File

@@ -0,0 +1,66 @@
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p7 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: PCIe SSD
Serial Number: --
Firmware Version: EHFM32.1
PCI Vendor/Subsystem ID: 0x1987
IEEE OUI Identifier: 0x6479a7
Controller ID: 0
NVMe Version: 1.4
Number of Namespaces: 1
Namespace 1 Size/Capacity: 250,059,350,016 [250 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Sat Dec 30 03:07:58 2023 UTC
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x1e): Cmd_Eff_Lg Ext_Get_Lg Telmtry_Lg Pers_Ev_Lg
Maximum Data Transfer Size: 64 Pages
Warning Comp. Temp. Threshold: 84 Celsius
Critical Comp. Temp. Threshold: 88 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 5.00W - - 0 0 0 0 0 0
1 + 2.40W - - 1 1 1 1 0 0
2 + 1.92W - - 2 2 2 2 0 0
3 - 0.0700W - - 3 3 3 3 1000 1000
4 - 0.0050W - - 4 4 4 4 10000 40000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 1
1 - 4096 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 64 Celsius
Available Spare: 100%
Available Spare Threshold: 5%
Percentage Used: 4%
Data Units Read: 1,053,198 [539 GB]
Data Units Written: 12,991,102 [6.65 TB]
Host Read Commands: 16,984,183
Host Write Commands: 99,445,387
Controller Busy Time: 39
Power Cycles: 118
Power On Hours: 8,826
Unsafe Shutdowns: 78
Media and Data Integrity Errors: 0
Error Information Log Entries: 0
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Error Information (NVMe Log 0x01, 16 of 63 entries)
No Errors Logged
Self-test Log (NVMe Log 0x06)
Self-test status: No self-test in progress
No Self-tests Logged

View File

@@ -0,0 +1,62 @@
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p7 amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: PCIe SSD
Serial Number: --
Firmware Version: EHFM32.1
PCI Vendor/Subsystem ID: 0x1987
IEEE OUI Identifier: 0x6479a7
Controller ID: 0
NVMe Version: 1.4
Number of Namespaces: 1
Namespace 1 Size/Capacity: 256,060,514,304 [256 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Thu Jun 8 12:32:45 2023 BST
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x1e): Cmd_Eff_Lg Ext_Get_Lg Telmtry_Lg Pers_Ev_Lg
Maximum Data Transfer Size: 64 Pages
Warning Comp. Temp. Threshold: 84 Celsius
Critical Comp. Temp. Threshold: 88 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 5.00W - - 0 0 0 0 0 0
1 + 2.40W - - 1 1 1 1 0 0
2 + 1.92W - - 2 2 2 2 0 0
3 - 0.0700W - - 3 3 3 3 1000 1000
4 - 0.0050W - - 4 4 4 4 10000 40000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 1
1 - 4096 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 51 Celsius
Available Spare: 100%
Available Spare Threshold: 5%
Percentage Used: 4%
Data Units Read: 33,997 [17.4 GB]
Data Units Written: 8,557,831 [4.38 TB]
Host Read Commands: 1,099,380
Host Write Commands: 433,256,689
Controller Busy Time: 510
Power Cycles: 26
Power On Hours: 2,821
Unsafe Shutdowns: 22
Media and Data Integrity Errors: 0
Error Information Log Entries: 0
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Error Information (NVMe Log 0x01, 16 of 63 entries)
No Errors Logged

View File

@@ -0,0 +1,69 @@
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p10 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: PCIe SSD
Serial Number: --
Firmware Version: EHFM90.1
PCI Vendor/Subsystem ID: 0x1987
IEEE OUI Identifier: 0x6479a7
Total NVM Capacity: 512,110,190,592 [512 GB]
Unallocated NVM Capacity: 0
Controller ID: 0
NVMe Version: 1.4
Number of Namespaces: 1
Namespace 1 Size/Capacity: 512,110,190,592 [512 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Sat Mar 16 22:43:06 2024 EDT
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x1e): Cmd_Eff_Lg Ext_Get_Lg Telmtry_Lg Pers_Ev_Lg
Maximum Data Transfer Size: 64 Pages
Warning Comp. Temp. Threshold: 83 Celsius
Critical Comp. Temp. Threshold: 85 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 5.00W 5.00W - 0 0 0 0 0 0
1 + 2.40W 2.50W - 1 1 1 1 0 1000
2 + 1.90W 1.80W - 2 2 2 2 0 0
3 - 0.0500W - - 3 3 3 3 5000 10000
4 - 0.0050W - - 4 4 4 4 10000 45000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 1
1 - 4096 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 36 Celsius
Available Spare: 100%
Available Spare Threshold: 50%
Percentage Used: 0%
Data Units Read: 1,468,707 [751 GB]
Data Units Written: 1,568,159 [802 GB]
Host Read Commands: 3,434,527
Host Write Commands: 4,134,173
Controller Busy Time: 60
Power Cycles: 13
Power On Hours: 98
Unsafe Shutdowns: 3
Media and Data Integrity Errors: 0
Error Information Log Entries: 41
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 53 Celsius
Error Information (NVMe Log 0x01, 16 of 63 entries)
No Errors Logged
Self-test Log (NVMe Log 0x06)
Self-test status: No self-test in progress
No Self-tests Logged

View File

@@ -0,0 +1,69 @@
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p9 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: PCIe SSD
Serial Number: --
Firmware Version: EHFM90.1
PCI Vendor/Subsystem ID: 0x1987
IEEE OUI Identifier: 0x6479a7
Total NVM Capacity: 512,110,190,592 [512 GB]
Unallocated NVM Capacity: 0
Controller ID: 0
NVMe Version: 1.4
Number of Namespaces: 1
Namespace 1 Size/Capacity: 512,110,190,592 [512 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Sun Feb 18 14:14:44 2024 CST
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x1e): Cmd_Eff_Lg Ext_Get_Lg Telmtry_Lg Pers_Ev_Lg
Maximum Data Transfer Size: 64 Pages
Warning Comp. Temp. Threshold: 83 Celsius
Critical Comp. Temp. Threshold: 85 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 5.00W 5.00W - 0 0 0 0 0 0
1 + 2.40W 2.50W - 1 1 1 1 0 1000
2 + 1.90W 1.80W - 2 2 2 2 0 0
3 - 0.0500W - - 3 3 3 3 5000 10000
4 - 0.0050W - - 4 4 4 4 10000 45000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 1
1 - 4096 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 39 Celsius
Available Spare: 100%
Available Spare Threshold: 50%
Percentage Used: 0%
Data Units Read: 1,746,295 [894 GB]
Data Units Written: 9,339,875 [4.78 TB]
Host Read Commands: 8,091,692
Host Write Commands: 87,103,958
Controller Busy Time: 85
Power Cycles: 27
Power On Hours: 1,563
Unsafe Shutdowns: 14
Media and Data Integrity Errors: 0
Error Information Log Entries: 81
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 57 Celsius
Error Information (NVMe Log 0x01, 16 of 63 entries)
No Errors Logged
Self-test Log (NVMe Log 0x06)
Self-test status: No self-test in progress
No Self-tests Logged

View File

@@ -0,0 +1,69 @@
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p7 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: PCIe SSD
Serial Number: --
Firmware Version: EHFM90.1
PCI Vendor/Subsystem ID: 0x1987
IEEE OUI Identifier: 0x6479a7
Total NVM Capacity: 512,110,190,592 [512 GB]
Unallocated NVM Capacity: 0
Controller ID: 0
NVMe Version: 1.4
Number of Namespaces: 1
Namespace 1 Size/Capacity: 512,110,190,592 [512 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Wed Jan 17 13:59:27 2024 EST
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x1e): Cmd_Eff_Lg Ext_Get_Lg Telmtry_Lg Pers_Ev_Lg
Maximum Data Transfer Size: 64 Pages
Warning Comp. Temp. Threshold: 83 Celsius
Critical Comp. Temp. Threshold: 85 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 5.00W 5.00W - 0 0 0 0 0 0
1 + 2.40W 2.50W - 1 1 1 1 0 1000
2 + 1.90W 1.80W - 2 2 2 2 0 0
3 - 0.0500W - - 3 3 3 3 5000 10000
4 - 0.0050W - - 4 4 4 4 10000 45000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 1
1 - 4096 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 37 Celsius
Available Spare: 100%
Available Spare Threshold: 50%
Percentage Used: 0%
Data Units Read: 1,484,111 [759 GB]
Data Units Written: 1,663,594 [851 GB]
Host Read Commands: 3,309,353
Host Write Commands: 5,244,395
Controller Busy Time: 53
Power Cycles: 8
Power On Hours: 101
Unsafe Shutdowns: 4
Media and Data Integrity Errors: 0
Error Information Log Entries: 20
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 54 Celsius
Error Information (NVMe Log 0x01, 16 of 63 entries)
No Errors Logged
Self-test Log (NVMe Log 0x06)
Self-test status: No self-test in progress
No Self-tests Logged

View File

@@ -0,0 +1,71 @@
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p11 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: PCIe SSD
Serial Number: --
Firmware Version: EDFM21.0
PCI Vendor/Subsystem ID: 0x1987
IEEE OUI Identifier: 0x6479a7
Total NVM Capacity: 128,035,676,160 [128 GB]
Unallocated NVM Capacity: 0
Controller ID: 1
NVMe Version: 1.3
Number of Namespaces: 1
Namespace 1 Size/Capacity: 128,035,676,160 [128 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Wed May 22 03:34:48 2024 CDT
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005e): Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x0a): Cmd_Eff_Lg Telmtry_Lg
Maximum Data Transfer Size: 64 Pages
Warning Comp. Temp. Threshold: 70 Celsius
Critical Comp. Temp. Threshold: 80 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 4.50W - - 0 0 0 0 0 0
1 + 2.70W - - 1 1 1 1 0 0
2 + 2.16W - - 2 2 2 2 0 0
3 - 0.0700W - - 3 3 3 3 1000 1000
4 - 0.0050W - - 4 4 4 4 5000 100000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 1
1 - 4096 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 39 Celsius
Available Spare: 100%
Available Spare Threshold: 5%
Percentage Used: 38%
Data Units Read: 86,115 [44.0 GB]
Data Units Written: 24,225,610 [12.4 TB]
Host Read Commands: 3,923,253
Host Write Commands: 412,690,371
Controller Busy Time: 3,441
Power Cycles: 29
Power On Hours: 4,275
Unsafe Shutdowns: 23
Media and Data Integrity Errors: 0
Error Information Log Entries: 0
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 55 Celsius
Thermal Temp. 1 Transition Count: 1
Thermal Temp. 1 Total Time: 20
Error Information (NVMe Log 0x01, 16 of 16 entries)
No Errors Logged
Self-test Log (NVMe Log 0x06)
Self-test status: No self-test in progress
No Self-tests Logged

View File

@@ -0,0 +1,69 @@
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p11 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: PCIe SSD
Serial Number: --
Firmware Version: EHFM90.1
PCI Vendor/Subsystem ID: 0x1987
IEEE OUI Identifier: 0x6479a7
Total NVM Capacity: 512,110,190,592 [512 GB]
Unallocated NVM Capacity: 0
Controller ID: 0
NVMe Version: 1.4
Number of Namespaces: 1
Namespace 1 Size/Capacity: 512,110,190,592 [512 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Wed Jul 31 20:55:09 2024 CDT
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x1e): Cmd_Eff_Lg Ext_Get_Lg Telmtry_Lg Pers_Ev_Lg
Maximum Data Transfer Size: 64 Pages
Warning Comp. Temp. Threshold: 83 Celsius
Critical Comp. Temp. Threshold: 85 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 5.00W 5.00W - 0 0 0 0 0 0
1 + 2.40W 2.50W - 1 1 1 1 0 1000
2 + 1.90W 1.80W - 2 2 2 2 0 0
3 - 0.0500W - - 3 3 3 3 5000 10000
4 - 0.0050W - - 4 4 4 4 10000 45000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 1
1 - 4096 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 32 Celsius
Available Spare: 100%
Available Spare Threshold: 50%
Percentage Used: 0%
Data Units Read: 1,511,638 [773 GB]
Data Units Written: 4,990,871 [2.55 TB]
Host Read Commands: 4,049,435
Host Write Commands: 35,287,815
Controller Busy Time: 90
Power Cycles: 49
Power On Hours: 1,838
Unsafe Shutdowns: 19
Media and Data Integrity Errors: 0
Error Information Log Entries: 119
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 48 Celsius
Error Information (NVMe Log 0x01, 16 of 63 entries)
No Errors Logged
Self-test Log (NVMe Log 0x06)
Self-test status: No self-test in progress
No Self-tests Logged

View File

@@ -0,0 +1,65 @@
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p8 amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: PCIe SSD
Serial Number: --
Firmware Version: EDFM21.0
PCI Vendor/Subsystem ID: 0x1987
IEEE OUI Identifier: 0x6479a7
Total NVM Capacity: 128,035,676,160 [128 GB]
Unallocated NVM Capacity: 0
Controller ID: 1
NVMe Version: 1.3
Number of Namespaces: 1
Namespace 1 Size/Capacity: 128,035,676,160 [128 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Sun Jul 30 21:25:45 2023 BST
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005e): Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x0a): Cmd_Eff_Lg Telmtry_Lg
Maximum Data Transfer Size: 64 Pages
Warning Comp. Temp. Threshold: 70 Celsius
Critical Comp. Temp. Threshold: 80 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 4.50W - - 0 0 0 0 0 0
1 + 2.70W - - 1 1 1 1 0 0
2 + 2.16W - - 2 2 2 2 0 0
3 - 0.0700W - - 3 3 3 3 1000 1000
4 - 0.0050W - - 4 4 4 4 5000 100000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 1
1 - 4096 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 36 Celsius
Available Spare: 100%
Available Spare Threshold: 5%
Percentage Used: 36%
Data Units Read: 990,818 [507 GB]
Data Units Written: 30,892,099 [15.8 TB]
Host Read Commands: 6,859,193
Host Write Commands: 419,341,394
Controller Busy Time: 959
Power Cycles: 110
Power On Hours: 2,282
Unsafe Shutdowns: 44
Media and Data Integrity Errors: 0
Error Information Log Entries: 189
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 51 Celsius
Error Information (NVMe Log 0x01, 16 of 16 entries)
No Errors Logged

View File

@@ -0,0 +1,67 @@
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p7 amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: PCIe SSD
Serial Number: --
Firmware Version: EDFMF0.0
PCI Vendor/Subsystem ID: 0x1987
IEEE OUI Identifier: 0x6479a7
Total NVM Capacity: 2,000,398,934,016 [2.00 TB]
Unallocated NVM Capacity: 0
Controller ID: 1
NVMe Version: 1.3
Number of Namespaces: 1
Namespace 1 Size/Capacity: 2,000,398,934,016 [2.00 TB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Sat May 13 08:19:31 2023 EDT
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x0056): Wr_Unc DS_Mngmt Sav/Sel_Feat Timestmp
Log Page Attributes (0x0a): Cmd_Eff_Lg Telmtry_Lg
Maximum Data Transfer Size: 64 Pages
Warning Comp. Temp. Threshold: 70 Celsius
Critical Comp. Temp. Threshold: 80 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 4.50W - - 0 0 0 0 0 0
1 + 2.70W - - 1 1 1 1 0 0
2 + 2.16W - - 2 2 2 2 0 0
3 - 0.0700W - - 3 3 3 3 5000 1900
4 - 0.0050W - - 4 4 4 4 13000 100000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 1
1 - 4096 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 34 Celsius
Available Spare: 100%
Available Spare Threshold: 5%
Percentage Used: 0%
Data Units Read: 12,049 [6.16 GB]
Data Units Written: 3,253,654 [1.66 TB]
Host Read Commands: 266,744
Host Write Commands: 53,481,694
Controller Busy Time: 169
Power Cycles: 14
Power On Hours: 1,580
Unsafe Shutdowns: 8
Media and Data Integrity Errors: 0
Error Information Log Entries: 0
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 52 Celsius
Error Information (NVMe Log 0x01, 16 of 16 entries)
No Errors Logged

View File

@@ -0,0 +1,65 @@
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p7 amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: PCIe SSD
Serial Number: --
Firmware Version: EDFMD1.0
PCI Vendor/Subsystem ID: 0x1987
IEEE OUI Identifier: 0x6479a7
Total NVM Capacity: 128,035,676,160 [128 GB]
Unallocated NVM Capacity: 0
Controller ID: 1
NVMe Version: 1.3
Number of Namespaces: 1
Namespace 1 Size/Capacity: 128,035,676,160 [128 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Sat Jun 24 21:29:54 2023 CEST
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x0a): Cmd_Eff_Lg Telmtry_Lg
Maximum Data Transfer Size: 64 Pages
Warning Comp. Temp. Threshold: 85 Celsius
Critical Comp. Temp. Threshold: 95 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 4.50W - - 0 0 0 0 0 0
1 + 2.70W - - 1 1 1 1 0 0
2 + 2.16W - - 2 2 2 2 0 0
3 - 0.0700W - - 3 3 3 3 1000 1000
4 - 0.0050W - - 4 4 4 4 5000 50000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 1
1 - 4096 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 51 Celsius
Available Spare: 100%
Available Spare Threshold: 5%
Percentage Used: 2%
Data Units Read: 19,384 [9.92 GB]
Data Units Written: 6,208,953 [3.17 TB]
Host Read Commands: 866,200
Host Write Commands: 169,327,471
Controller Busy Time: 214
Power Cycles: 16
Power On Hours: 1,887
Unsafe Shutdowns: 8
Media and Data Integrity Errors: 0
Error Information Log Entries: 0
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 70 Celsius
Error Information (NVMe Log 0x01, 16 of 16 entries)
No Errors Logged

View File

@@ -0,0 +1,69 @@
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p11 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: PCIe SSD
Serial Number: --
Firmware Version: EHFM90.1
PCI Vendor/Subsystem ID: 0x1987
IEEE OUI Identifier: 0x6479a7
Total NVM Capacity: 512,110,190,592 [512 GB]
Unallocated NVM Capacity: 0
Controller ID: 0
NVMe Version: 1.4
Number of Namespaces: 1
Namespace 1 Size/Capacity: 512,110,190,592 [512 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Sat May 18 22:06:48 2024 CEST
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x1e): Cmd_Eff_Lg Ext_Get_Lg Telmtry_Lg Pers_Ev_Lg
Maximum Data Transfer Size: 64 Pages
Warning Comp. Temp. Threshold: 83 Celsius
Critical Comp. Temp. Threshold: 85 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 5.00W 5.00W - 0 0 0 0 0 0
1 + 2.40W 2.50W - 1 1 1 1 0 1000
2 + 1.90W 1.80W - 2 2 2 2 0 0
3 - 0.0500W - - 3 3 3 3 5000 10000
4 - 0.0050W - - 4 4 4 4 10000 45000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 1
1 - 4096 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 53 Celsius
Available Spare: 100%
Available Spare Threshold: 50%
Percentage Used: 0%
Data Units Read: 1,082,214 [554 GB]
Data Units Written: 1,738,842 [890 GB]
Host Read Commands: 3,149,006
Host Write Commands: 9,664,668
Controller Busy Time: 34
Power Cycles: 82
Power On Hours: 778
Unsafe Shutdowns: 25
Media and Data Integrity Errors: 0
Error Information Log Entries: 150
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 75 Celsius
Error Information (NVMe Log 0x01, 16 of 63 entries)
No Errors Logged
Self-test Log (NVMe Log 0x06)
Self-test status: No self-test in progress
No Self-tests Logged

View File

@@ -0,0 +1,69 @@
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p5 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: PCIe SSD
Serial Number: --
Firmware Version: EDFM21.0
PCI Vendor/Subsystem ID: 0x1987
IEEE OUI Identifier: 0x6479a7
Total NVM Capacity: 128,035,676,160 [128 GB]
Unallocated NVM Capacity: 0
Controller ID: 1
NVMe Version: 1.3
Number of Namespaces: 1
Namespace 1 Size/Capacity: 128,035,676,160 [128 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Thu Nov 23 11:53:13 2023 CST
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005e): Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x0a): Cmd_Eff_Lg Telmtry_Lg
Maximum Data Transfer Size: 64 Pages
Warning Comp. Temp. Threshold: 70 Celsius
Critical Comp. Temp. Threshold: 80 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 4.50W - - 0 0 0 0 0 0
1 + 2.70W - - 1 1 1 1 0 0
2 + 2.16W - - 2 2 2 2 0 0
3 - 0.0700W - - 3 3 3 3 1000 1000
4 - 0.0050W - - 4 4 4 4 5000 100000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 1
1 - 4096 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 41 Celsius
Available Spare: 100%
Available Spare Threshold: 5%
Percentage Used: 0%
Data Units Read: 3,574 [1.82 GB]
Data Units Written: 19,225 [9.84 GB]
Host Read Commands: 145,928
Host Write Commands: 811,334
Controller Busy Time: 1
Power Cycles: 1
Power On Hours: 71
Unsafe Shutdowns: 1
Media and Data Integrity Errors: 0
Error Information Log Entries: 2
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 57 Celsius
Error Information (NVMe Log 0x01, 16 of 16 entries)
No Errors Logged
Self-test Log (NVMe Log 0x06)
Self-test status: No self-test in progress
No Self-tests Logged

View File

@@ -0,0 +1,69 @@
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p4 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: PCIe SSD
Serial Number: --
Firmware Version: EHFM90.1
PCI Vendor/Subsystem ID: 0x1987
IEEE OUI Identifier: 0x6479a7
Total NVM Capacity: 512,110,190,592 [512 GB]
Unallocated NVM Capacity: 0
Controller ID: 0
NVMe Version: 1.4
Number of Namespaces: 1
Namespace 1 Size/Capacity: 512,110,190,592 [512 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Wed Dec 13 11:43:01 2023 EST
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x1e): Cmd_Eff_Lg Ext_Get_Lg Telmtry_Lg Pers_Ev_Lg
Maximum Data Transfer Size: 64 Pages
Warning Comp. Temp. Threshold: 83 Celsius
Critical Comp. Temp. Threshold: 85 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 5.00W 5.00W - 0 0 0 0 0 0
1 + 2.40W 2.50W - 1 1 1 1 0 1000
2 + 1.90W 1.80W - 2 2 2 2 0 0
3 - 0.0500W - - 3 3 3 3 5000 10000
4 - 0.0050W - - 4 4 4 4 10000 45000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 1
1 - 4096 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 42 Celsius
Available Spare: 100%
Available Spare Threshold: 50%
Percentage Used: 0%
Data Units Read: 1,631,538 [835 GB]
Data Units Written: 2,485,244 [1.27 TB]
Host Read Commands: 6,646,381
Host Write Commands: 27,288,132
Controller Busy Time: 246
Power Cycles: 20
Power On Hours: 2,130
Unsafe Shutdowns: 11
Media and Data Integrity Errors: 0
Error Information Log Entries: 67
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 60 Celsius
Error Information (NVMe Log 0x01, 16 of 63 entries)
No Errors Logged
Self-test Log (NVMe Log 0x06)
Self-test status: No self-test in progress
No Self-tests Logged

View File

@@ -0,0 +1,69 @@
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p7 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: PCIe SSD
Serial Number: --
Firmware Version: EHFM90.1
PCI Vendor/Subsystem ID: 0x1987
IEEE OUI Identifier: 0x6479a7
Total NVM Capacity: 512,110,190,592 [512 GB]
Unallocated NVM Capacity: 0
Controller ID: 0
NVMe Version: 1.4
Number of Namespaces: 1
Namespace 1 Size/Capacity: 512,110,190,592 [512 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Fri Jul 19 13:25:38 2024 CDT
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x1e): Cmd_Eff_Lg Ext_Get_Lg Telmtry_Lg Pers_Ev_Lg
Maximum Data Transfer Size: 64 Pages
Warning Comp. Temp. Threshold: 83 Celsius
Critical Comp. Temp. Threshold: 85 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 5.00W 5.00W - 0 0 0 0 0 0
1 + 2.40W 2.50W - 1 1 1 1 0 1000
2 + 1.90W 1.80W - 2 2 2 2 0 0
3 - 0.0500W - - 3 3 3 3 5000 10000
4 - 0.0050W - - 4 4 4 4 10000 45000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 1
1 - 4096 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 41 Celsius
Available Spare: 100%
Available Spare Threshold: 50%
Percentage Used: 1%
Data Units Read: 1,600,766 [819 GB]
Data Units Written: 31,992,446 [16.3 TB]
Host Read Commands: 5,525,112
Host Write Commands: 288,374,121
Controller Busy Time: 92
Power Cycles: 16
Power On Hours: 1,061
Unsafe Shutdowns: 8
Media and Data Integrity Errors: 0
Error Information Log Entries: 33
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 59 Celsius
Error Information (NVMe Log 0x01, 16 of 63 entries)
No Errors Logged
Self-test Log (NVMe Log 0x06)
Self-test status: No self-test in progress
No Self-tests Logged

View File

@@ -0,0 +1,69 @@
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p7 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: PCIe SSD
Serial Number: --
Firmware Version: EHFM90.1
PCI Vendor/Subsystem ID: 0x1987
IEEE OUI Identifier: 0x6479a7
Total NVM Capacity: 512,110,190,592 [512 GB]
Unallocated NVM Capacity: 0
Controller ID: 0
NVMe Version: 1.4
Number of Namespaces: 1
Namespace 1 Size/Capacity: 512,110,190,592 [512 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Thu Jan 11 15:09:51 2024 PST
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x1e): Cmd_Eff_Lg Ext_Get_Lg Telmtry_Lg Pers_Ev_Lg
Maximum Data Transfer Size: 64 Pages
Warning Comp. Temp. Threshold: 83 Celsius
Critical Comp. Temp. Threshold: 85 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 5.00W 5.00W - 0 0 0 0 0 0
1 + 2.40W 2.50W - 1 1 1 1 0 1000
2 + 1.90W 1.80W - 2 2 2 2 0 0
3 - 0.0500W - - 3 3 3 3 5000 10000
4 - 0.0050W - - 4 4 4 4 10000 45000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 1
1 - 4096 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 35 Celsius
Available Spare: 100%
Available Spare Threshold: 50%
Percentage Used: 0%
Data Units Read: 1,496,575 [766 GB]
Data Units Written: 1,716,862 [879 GB]
Host Read Commands: 3,572,968
Host Write Commands: 4,536,821
Controller Busy Time: 56
Power Cycles: 26
Power On Hours: 8
Unsafe Shutdowns: 17
Media and Data Integrity Errors: 0
Error Information Log Entries: 20
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 52 Celsius
Error Information (NVMe Log 0x01, 16 of 63 entries)
No Errors Logged
Self-test Log (NVMe Log 0x06)
Self-test status: No self-test in progress
No Self-tests Logged

View File

@@ -0,0 +1,66 @@
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p10 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: PSE12F-M2280-512G-V01
Serial Number: --
Firmware Version: ECPM13.0
PCI Vendor/Subsystem ID: 0x1987
IEEE OUI Identifier: 0x6479a7
Total NVM Capacity: 512,110,190,592 [512 GB]
Unallocated NVM Capacity: 0
Controller ID: 1
NVMe Version: 1.3
Number of Namespaces: 1
Namespace 1 Size/Capacity: 512,110,190,592 [512 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Tue Mar 19 00:21:14 2024 PDT
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0007): Security Format Frmw_DL
Optional NVM Commands (0x005d): Comp DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x08): Telmtry_Lg
Maximum Data Transfer Size: 512 Pages
Warning Comp. Temp. Threshold: 75 Celsius
Critical Comp. Temp. Threshold: 80 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 8.09W - - 0 0 0 0 0 0
1 + 6.37W - - 1 1 1 1 0 0
2 + 5.52W - - 2 2 2 2 0 0
3 - 0.0490W - - 3 3 3 3 2000 2000
4 - 0.0018W - - 4 4 4 4 25000 25000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 2
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 63 Celsius
Available Spare: 100%
Available Spare Threshold: 5%
Percentage Used: 0%
Data Units Read: 42,741 [21.8 GB]
Data Units Written: 345,789 [177 GB]
Host Read Commands: 1,036,794
Host Write Commands: 4,418,209
Controller Busy Time: 5
Power Cycles: 21
Power On Hours: 278
Unsafe Shutdowns: 8
Media and Data Integrity Errors: 0
Error Information Log Entries: 2
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Thermal Temp. 1 Transition Count: 1
Error Information (NVMe Log 0x01, 16 of 63 entries)
No Errors Logged
Self-tests not supported

View File

@@ -0,0 +1,83 @@
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: PSEJN512GA87EC0
Serial Number: --
Firmware Version: HPE36P01
PCI Vendor/Subsystem ID: 0x1987
IEEE OUI Identifier: 0x6479a7
Total NVM Capacity: 512,110,190,592 [512 GB]
Unallocated NVM Capacity: 0
Controller ID: 1
NVMe Version: 1.4
Number of Namespaces: 1
Namespace 1 Size/Capacity: 512,110,190,592 [512 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Tue May 28 18:56:28 2024 UTC
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x1e): Cmd_Eff_Lg Ext_Get_Lg Telmtry_Lg Pers_Ev_Lg
Maximum Data Transfer Size: 64 Pages
Warning Comp. Temp. Threshold: 83 Celsius
Critical Comp. Temp. Threshold: 85 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 5.00W - - 0 0 0 0 0 0
1 + 3.00W - - 1 1 1 1 0 0
2 + 1.50W - - 2 2 2 2 0 0
3 - 0.1000W - - 3 3 3 3 5000 10000
4 - 0.0025W - - 4 4 4 4 5000 45000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 1
1 - 4096 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 38 Celsius
Available Spare: 100%
Available Spare Threshold: 10%
Percentage Used: 3%
Data Units Read: 31,106,954 [15.9 TB]
Data Units Written: 28,812,698 [14.7 TB]
Host Read Commands: 171,142,796
Host Write Commands: 274,053,901
Controller Busy Time: 822
Power Cycles: 1,037
Power On Hours: 212
Unsafe Shutdowns: 106
Media and Data Integrity Errors: 0
Error Information Log Entries: 2,671
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 45 Celsius
Temperature Sensor 2: 38 Celsius
Error Information (NVMe Log 0x01, 16 of 63 entries)
Num ErrCount SQId CmdId Status PELoc LBA NSID VS
0 2671 0 0x0014 0xc004 0x028 0 0 -
1 2670 0 0x301c 0xc004 0x004 0 1 -
2 2669 0 0x3000 0xc004 0x004 0 1 -
3 2668 0 0xd01c 0xc004 0x028 0 0 -
4 2667 0 0x9011 0xc004 0x004 0 1 -
5 2666 0 0x400f 0xc004 0x004 0 1 -
6 2665 0 0x8010 0xc004 0x004 0 1 -
7 2664 0 0x501c 0xc004 0x004 0 1 -
8 2663 0 0x4000 0xc004 0x004 0 1 -
9 2662 0 0x1002 0xc004 0x028 0 0 -
10 2661 0 0xc011 0xc004 0x004 0 1 -
11 2660 0 0xf010 0xc004 0x004 0 1 -
12 2659 0 0xa00a 0xc004 0x004 0 1 -
13 2658 0 0x9009 0xc004 0x004 0 1 -
14 2657 0 0x0010 0xc004 0x028 0 0 -
15 2656 0 0x200c 0xc004 0x004 0 1 -
... (47 entries not read)

View File

@@ -0,0 +1,72 @@
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p3 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: Sabrent Rocket 4.0 1TB
Serial Number: --
Firmware Version: RKT401.3
PCI Vendor/Subsystem ID: 0x1987
IEEE OUI Identifier: 0x6479a7
Total NVM Capacity: 1,000,204,886,016 [1.00 TB]
Unallocated NVM Capacity: 0
Controller ID: 1
NVMe Version: 1.3
Number of Namespaces: 1
Namespace 1 Size/Capacity: 1,000,204,886,016 [1.00 TB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Sun Sep 24 12:39:31 2023 PDT
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005d): Comp DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x08): Telmtry_Lg
Maximum Data Transfer Size: 512 Pages
Warning Comp. Temp. Threshold: 90 Celsius
Critical Comp. Temp. Threshold: 95 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 9.78W - - 0 0 0 0 0 0
1 + 6.75W - - 1 1 1 1 0 0
2 + 5.23W - - 2 2 2 2 0 0
3 - 0.0490W - - 3 3 3 3 2000 2000
4 - 0.0018W - - 4 4 4 4 25000 25000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 2
1 - 4096 0 1
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 87 Celsius
Available Spare: 100%
Available Spare Threshold: 5%
Percentage Used: 0%
Data Units Read: 21,943 [11.2 GB]
Data Units Written: 2,479,496 [1.26 TB]
Host Read Commands: 573,125
Host Write Commands: 65,648,604
Controller Busy Time: 54
Power Cycles: 26
Power On Hours: 529
Unsafe Shutdowns: 22
Media and Data Integrity Errors: 0
Error Information Log Entries: 3
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Thermal Temp. 1 Transition Count: 3
Thermal Temp. 2 Transition Count: 5
Thermal Temp. 1 Total Time: 64
Thermal Temp. 2 Total Time: 1046
Error Information (NVMe Log 0x01, 16 of 63 entries)
No Errors Logged
Self-test Log (NVMe Log 0x06)
Self-test status: No self-test in progress
No Self-tests Logged

View File

@@ -0,0 +1,70 @@
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p11 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: Sabrent Rocket 4.0 500GB
Serial Number: --
Firmware Version: RKT401.4
PCI Vendor/Subsystem ID: 0x1987
IEEE OUI Identifier: 0x6479a7
Total NVM Capacity: 500,107,862,016 [500 GB]
Unallocated NVM Capacity: 0
Controller ID: 1
NVMe Version: 1.3
Number of Namespaces: 1
Namespace 1 Size/Capacity: 500,107,862,016 [500 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Wed May 29 23:00:39 2024 AEST
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005d): Comp DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x08): Telmtry_Lg
Maximum Data Transfer Size: 512 Pages
Warning Comp. Temp. Threshold: 90 Celsius
Critical Comp. Temp. Threshold: 95 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 7.14W - - 0 0 0 0 0 0
1 + 5.43W - - 1 1 1 1 0 0
2 + 4.57W - - 2 2 2 2 0 0
3 - 0.0490W - - 3 3 3 3 2000 2000
4 - 0.0018W - - 4 4 4 4 25000 25000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 2
1 - 4096 0 1
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 54 Celsius
Available Spare: 100%
Available Spare Threshold: 5%
Percentage Used: 0%
Data Units Read: 30,764 [15.7 GB]
Data Units Written: 2,713,819 [1.38 TB]
Host Read Commands: 1,240,157
Host Write Commands: 35,515,407
Controller Busy Time: 53
Power Cycles: 46
Power On Hours: 1,869
Unsafe Shutdowns: 22
Media and Data Integrity Errors: 0
Error Information Log Entries: 0
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Error Information (NVMe Log 0x01, 16 of 63 entries)
No Errors Logged
Self-test Log (NVMe Log 0x06)
Self-test status: No self-test in progress
No Self-tests Logged

View File

@@ -0,0 +1,70 @@
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p10 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: Sabrent Rocket 4.0 500GB
Serial Number: --
Firmware Version: RKT401.3
PCI Vendor/Subsystem ID: 0x1987
IEEE OUI Identifier: 0x6479a7
Total NVM Capacity: 500,107,862,016 [500 GB]
Unallocated NVM Capacity: 0
Controller ID: 1
NVMe Version: 1.3
Number of Namespaces: 1
Namespace 1 Size/Capacity: 500,107,862,016 [500 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Sat Mar 23 12:50:05 2024 CDT
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005d): Comp DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x08): Telmtry_Lg
Maximum Data Transfer Size: 512 Pages
Warning Comp. Temp. Threshold: 90 Celsius
Critical Comp. Temp. Threshold: 95 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 7.14W - - 0 0 0 0 0 0
1 + 5.43W - - 1 1 1 1 0 0
2 + 4.57W - - 2 2 2 2 0 0
3 - 0.0490W - - 3 3 3 3 2000 2000
4 - 0.0018W - - 4 4 4 4 25000 25000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 2
1 - 4096 0 1
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 37 Celsius
Available Spare: 100%
Available Spare Threshold: 5%
Percentage Used: 0%
Data Units Read: 1,329,639 [680 GB]
Data Units Written: 7,445,430 [3.81 TB]
Host Read Commands: 12,315,868
Host Write Commands: 63,908,031
Controller Busy Time: 51
Power Cycles: 1,845
Power On Hours: 1,170
Unsafe Shutdowns: 28
Media and Data Integrity Errors: 0
Error Information Log Entries: 120
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Error Information (NVMe Log 0x01, 16 of 63 entries)
No Errors Logged
Self-test Log (NVMe Log 0x06)
Self-test status: No self-test in progress
Num Test_Description Status Power_on_Hours Failing_LBA NSID Seg SCT Code
0 Extended Completed without error 0 - - - - -
1 Short Completed without error 0 - - - - -

View File

@@ -0,0 +1,68 @@
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p11 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: Sabrent Rocket 4.0 500GB
Serial Number: --
Firmware Version: RKT401.4
PCI Vendor/Subsystem ID: 0x1987
IEEE OUI Identifier: 0x6479a7
Total NVM Capacity: 500,107,862,016 [500 GB]
Unallocated NVM Capacity: 0
Controller ID: 1
NVMe Version: 1.3
Number of Namespaces: 1
Namespace 1 Size/Capacity: 500,107,862,016 [500 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Wed May 29 23:00:39 2024 AEST
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005d): Comp DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x08): Telmtry_Lg
Maximum Data Transfer Size: 512 Pages
Warning Comp. Temp. Threshold: 90 Celsius
Critical Comp. Temp. Threshold: 95 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 7.14W - - 0 0 0 0 0 0
1 + 5.43W - - 1 1 1 1 0 0
2 + 4.57W - - 2 2 2 2 0 0
3 - 0.0490W - - 3 3 3 3 2000 2000
4 - 0.0018W - - 4 4 4 4 25000 25000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 2
1 - 4096 0 1
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 54 Celsius
Available Spare: 100%
Available Spare Threshold: 5%
Percentage Used: 0%
Data Units Read: 29,367 [15.0 GB]
Data Units Written: 2,687,711 [1.37 TB]
Host Read Commands: 1,209,338
Host Write Commands: 35,209,753
Controller Busy Time: 52
Power Cycles: 47
Power On Hours: 1,871
Unsafe Shutdowns: 22
Media and Data Integrity Errors: 0
Error Information Log Entries: 0
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Error Information (NVMe Log 0x01, 16 of 63 entries)
No Errors Logged
Self-test Log (NVMe Log 0x06)
Self-test status: No self-test in progress
No Self-tests Logged

View File

@@ -0,0 +1,70 @@
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p3 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: Sabrent ROCKET-PRO
Serial Number: --
Firmware Version: ECFM12.1
PCI Vendor/Subsystem ID: 0x1987
IEEE OUI Identifier: 0x6479a7
Total NVM Capacity: 256,060,514,304 [256 GB]
Unallocated NVM Capacity: 0
Controller ID: 1
NVMe Version: 1.3
Number of Namespaces: 1
Namespace 1 Size/Capacity: 256,060,514,304 [256 GB]
Namespace 1 Formatted LBA Size: 4096
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Fri Sep 22 19:14:34 2023 AKDT
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005d): Comp DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x0c): Ext_Get_Lg Telmtry_Lg
Maximum Data Transfer Size: 512 Pages
Warning Comp. Temp. Threshold: 70 Celsius
Critical Comp. Temp. Threshold: 90 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 6.80W - - 0 0 0 0 0 0
1 + 5.74W - - 1 1 1 1 0 0
2 + 5.21W - - 2 2 2 2 0 0
3 - 0.0490W - - 3 3 3 3 2000 2000
4 - 0.0018W - - 4 4 4 4 25000 25000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 - 512 0 2
1 + 4096 0 1
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 56 Celsius
Available Spare: 100%
Available Spare Threshold: 5%
Percentage Used: 4%
Data Units Read: 2,479,183 [1.26 TB]
Data Units Written: 22,761,033 [11.6 TB]
Host Read Commands: 21,853,410
Host Write Commands: 177,506,777
Controller Busy Time: 389
Power Cycles: 2,575
Power On Hours: 7,134
Unsafe Shutdowns: 38
Media and Data Integrity Errors: 0
Error Information Log Entries: 2
Warning Comp. Temperature Time: 3
Critical Comp. Temperature Time: 0
Error Information (NVMe Log 0x01, 16 of 63 entries)
Num ErrCount SQId CmdId Status PELoc LBA NSID VS Message
0 2 0 0x0008 0x4004 - 0 0 - Invalid Field in Command
1 1 0 0x0000 0x4004 - 0 0 - Invalid Field in Command
Self-test Log (NVMe Log 0x06)
Self-test status: No self-test in progress
No Self-tests Logged

View File

@@ -0,0 +1,64 @@
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.2-RELEASE-p2 amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: Sabrent Rocket Q
Serial Number: --
Firmware Version: RKT30Q.1
PCI Vendor/Subsystem ID: 0x1987
IEEE OUI Identifier: 0x6479a7
Total NVM Capacity: 500,107,862,016 [500 GB]
Unallocated NVM Capacity: 0
Controller ID: 1
NVMe Version: 1.3
Number of Namespaces: 1
Namespace 1 Size/Capacity: 500,107,862,016 [500 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Sat Aug 19 18:16:23 2023 EDT
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005d): Comp DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x08): Telmtry_Lg
Maximum Data Transfer Size: 512 Pages
Warning Comp. Temp. Threshold: 75 Celsius
Critical Comp. Temp. Threshold: 80 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 4.49W - - 0 0 0 0 0 0
1 + 3.97W - - 1 1 1 1 0 0
2 + 3.70W - - 2 2 2 2 0 0
3 - 0.0490W - - 3 3 3 3 2000 2000
4 - 0.0018W - - 4 4 4 4 25000 25000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 2
1 - 4096 0 1
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 30 Celsius
Available Spare: 100%
Available Spare Threshold: 5%
Percentage Used: 11%
Data Units Read: 26,935,981 [13.7 TB]
Data Units Written: 14,256,433 [7.29 TB]
Host Read Commands: 114,844,490
Host Write Commands: 97,548,302
Controller Busy Time: 1,074
Power Cycles: 368
Power On Hours: 12,229
Unsafe Shutdowns: 57
Media and Data Integrity Errors: 0
Error Information Log Entries: 896
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Error Information (NVMe Log 0x01, 16 of 63 entries)
No Errors Logged

View File

@@ -0,0 +1,68 @@
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p3 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: Sabrent Rocket Q
Serial Number: --
Firmware Version: RKT30Q.1
PCI Vendor/Subsystem ID: 0x1987
IEEE OUI Identifier: 0x6479a7
Total NVM Capacity: 500,107,862,016 [500 GB]
Unallocated NVM Capacity: 0
Controller ID: 1
NVMe Version: 1.3
Number of Namespaces: 1
Namespace 1 Size/Capacity: 500,107,862,016 [500 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Sat Oct 28 01:23:25 2023 CEST
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005d): Comp DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x08): Telmtry_Lg
Maximum Data Transfer Size: 512 Pages
Warning Comp. Temp. Threshold: 75 Celsius
Critical Comp. Temp. Threshold: 80 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 4.49W - - 0 0 0 0 0 0
1 + 3.97W - - 1 1 1 1 0 0
2 + 3.70W - - 2 2 2 2 0 0
3 - 0.0490W - - 3 3 3 3 2000 2000
4 - 0.0018W - - 4 4 4 4 25000 25000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 2
1 - 4096 0 1
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 28 Celsius
Available Spare: 100%
Available Spare Threshold: 5%
Percentage Used: 8%
Data Units Read: 4,130,901 [2.11 TB]
Data Units Written: 10,645,936 [5.45 TB]
Host Read Commands: 63,231,805
Host Write Commands: 231,112,069
Controller Busy Time: 489
Power Cycles: 448
Power On Hours: 3,231
Unsafe Shutdowns: 257
Media and Data Integrity Errors: 0
Error Information Log Entries: 1,276
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Error Information (NVMe Log 0x01, 16 of 63 entries)
No Errors Logged
Self-test Log (NVMe Log 0x06)
Self-test status: No self-test in progress
No Self-tests Logged

View File

@@ -0,0 +1,68 @@
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p10 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: Sabrent Rocket Q
Serial Number: --
Firmware Version: RKT30Q.3
PCI Vendor/Subsystem ID: 0x1987
IEEE OUI Identifier: 0x6479a7
Total NVM Capacity: 500,107,862,016 [500 GB]
Unallocated NVM Capacity: 0
Controller ID: 1
NVMe Version: 1.3
Number of Namespaces: 1
Namespace 1 Size/Capacity: 500,107,862,016 [500 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Sun Mar 10 10:02:00 2024 CDT
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005d): Comp DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x08): Telmtry_Lg
Maximum Data Transfer Size: 512 Pages
Warning Comp. Temp. Threshold: 75 Celsius
Critical Comp. Temp. Threshold: 80 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 4.49W - - 0 0 0 0 0 0
1 + 3.97W - - 1 1 1 1 0 0
2 + 3.70W - - 2 2 2 2 0 0
3 - 0.0490W - - 3 3 3 3 2000 2000
4 - 0.0018W - - 4 4 4 4 25000 25000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 2
1 - 4096 0 1
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 44 Celsius
Available Spare: 100%
Available Spare Threshold: 5%
Percentage Used: 4%
Data Units Read: 34,106 [17.4 GB]
Data Units Written: 6,241,013 [3.19 TB]
Host Read Commands: 1,051,347
Host Write Commands: 188,746,702
Controller Busy Time: 220
Power Cycles: 40
Power On Hours: 2,395
Unsafe Shutdowns: 29
Media and Data Integrity Errors: 0
Error Information Log Entries: 0
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Error Information (NVMe Log 0x01, 16 of 63 entries)
No Errors Logged
Self-test Log (NVMe Log 0x06)
Self-test status: No self-test in progress
No Self-tests Logged

View File

@@ -0,0 +1,70 @@
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-STABLE amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: Sabrent
Serial Number: --
Firmware Version: RKT343.4
PCI Vendor/Subsystem ID: 0x1987
IEEE OUI Identifier: 0x6479a7
Total NVM Capacity: 1,024,209,543,168 [1.02 TB]
Unallocated NVM Capacity: 0
Controller ID: 1
NVMe Version: 1.3
Number of Namespaces: 1
Namespace 1 Size/Capacity: 1,024,209,543,168 [1.02 TB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Sun Sep 17 21:36:15 2023 +08
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005d): Comp DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x08): Telmtry_Lg
Maximum Data Transfer Size: 512 Pages
Warning Comp. Temp. Threshold: 75 Celsius
Critical Comp. Temp. Threshold: 80 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 9.51W - - 0 0 0 0 0 0
1 + 6.47W - - 1 1 1 1 0 0
2 + 4.96W - - 2 2 2 2 0 0
3 - 0.0490W - - 3 3 3 3 2000 2000
4 - 0.0018W - - 4 4 4 4 25000 25000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 2
1 - 4096 0 1
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 33 Celsius
Available Spare: 100%
Available Spare Threshold: 5%
Percentage Used: 6%
Data Units Read: 36,041,555 [18.4 TB]
Data Units Written: 100,173,750 [51.2 TB]
Host Read Commands: 430,206,537
Host Write Commands: 2,542,473,869
Controller Busy Time: 21,983
Power Cycles: 428
Power On Hours: 9,835
Unsafe Shutdowns: 35
Media and Data Integrity Errors: 0
Error Information Log Entries: 3,774
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Error Information (NVMe Log 0x01, 16 of 63 entries)
No Errors Logged
Self-test Log (NVMe Log 0x06)
Self-test status: No self-test in progress
No Self-tests Logged

View File

@@ -0,0 +1,68 @@
smartctl 7.3 2022-02-28 r5338 [FreeBSD 14.0-CURRENT amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: Sabrent
Serial Number: --
Firmware Version: RKT343.4
PCI Vendor/Subsystem ID: 0x1987
IEEE OUI Identifier: 0x6479a7
Total NVM Capacity: 1,024,209,543,168 [1.02 TB]
Unallocated NVM Capacity: 0
Controller ID: 1
NVMe Version: 1.3
Number of Namespaces: 1
Namespace 1 Size/Capacity: 1,024,209,543,168 [1.02 TB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Sat Jun 17 09:20:50 2023 CDT
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005d): Comp DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x08): Telmtry_Lg
Maximum Data Transfer Size: 512 Pages
Warning Comp. Temp. Threshold: 75 Celsius
Critical Comp. Temp. Threshold: 80 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 9.51W - - 0 0 0 0 0 0
1 + 6.47W - - 1 1 1 1 0 0
2 + 4.96W - - 2 2 2 2 0 0
3 - 0.0490W - - 3 3 3 3 2000 2000
4 - 0.0018W - - 4 4 4 4 25000 25000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 2
1 - 4096 0 1
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 28 Celsius
Available Spare: 100%
Available Spare Threshold: 5%
Percentage Used: 1%
Data Units Read: 20,017,956 [10.2 TB]
Data Units Written: 25,007,887 [12.8 TB]
Host Read Commands: 114,888,234
Host Write Commands: 187,777,857
Controller Busy Time: 637
Power Cycles: 83
Power On Hours: 8,892
Unsafe Shutdowns: 35
Media and Data Integrity Errors: 0
Error Information Log Entries: 829
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Thermal Temp. 1 Transition Count: 3
Thermal Temp. 1 Total Time: 1672
Error Information (NVMe Log 0x01, 16 of 63 entries)
No Errors Logged

View File

@@ -0,0 +1,69 @@
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p11 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: Sabrent
Serial Number: --
Firmware Version: RKT343.4
PCI Vendor/Subsystem ID: 0x1987
IEEE OUI Identifier: 0x6479a7
Total NVM Capacity: 512,110,190,592 [512 GB]
Unallocated NVM Capacity: 0
Controller ID: 1
NVMe Version: 1.3
Number of Namespaces: 1
Namespace 1 Size/Capacity: 512,110,190,592 [512 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Wed Jun 12 13:56:04 2024 CEST
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005d): Comp DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x08): Telmtry_Lg
Maximum Data Transfer Size: 512 Pages
Warning Comp. Temp. Threshold: 75 Celsius
Critical Comp. Temp. Threshold: 80 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 6.87W - - 0 0 0 0 0 0
1 + 5.15W - - 1 1 1 1 0 0
2 + 4.30W - - 2 2 2 2 0 0
3 - 0.0490W - - 3 3 3 3 2000 2000
4 - 0.0018W - - 4 4 4 4 25000 25000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 2
1 - 4096 0 1
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 28 Celsius
Available Spare: 100%
Available Spare Threshold: 5%
Percentage Used: 0%
Data Units Read: 722 [369 MB]
Data Units Written: 29,835 [15.2 GB]
Host Read Commands: 19,329
Host Write Commands: 119,761
Controller Busy Time: 0
Power Cycles: 32
Power On Hours: 19,227
Unsafe Shutdowns: 26
Media and Data Integrity Errors: 0
Error Information Log Entries: 0
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Error Information (NVMe Log 0x01, 16 of 63 entries)
No Errors Logged
Self-test Log (NVMe Log 0x06)
Self-test status: No self-test in progress
Num Test_Description Status Power_on_Hours Failing_LBA NSID Seg SCT Code
0 Short Aborted: Self-test command 14233 - - - - -

View File

@@ -0,0 +1,73 @@
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p10 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: Sabrent
Serial Number: --
Firmware Version: RKT343.4
PCI Vendor/Subsystem ID: 0x1987
IEEE OUI Identifier: 0x6479a7
Total NVM Capacity: 512,110,190,592 [512 GB]
Unallocated NVM Capacity: 0
Controller ID: 1
NVMe Version: 1.3
Number of Namespaces: 1
Namespace 1 Size/Capacity: 512,110,190,592 [512 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Mon Apr 1 15:53:33 2024 EDT
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005d): Comp DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x08): Telmtry_Lg
Maximum Data Transfer Size: 512 Pages
Warning Comp. Temp. Threshold: 75 Celsius
Critical Comp. Temp. Threshold: 80 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 6.87W - - 0 0 0 0 0 0
1 + 5.15W - - 1 1 1 1 0 0
2 + 4.30W - - 2 2 2 2 0 0
3 - 0.0490W - - 3 3 3 3 2000 2000
4 - 0.0018W - - 4 4 4 4 25000 25000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 2
1 - 4096 0 1
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 34 Celsius
Available Spare: 100%
Available Spare Threshold: 5%
Percentage Used: 0%
Data Units Read: 23,919 [12.2 GB]
Data Units Written: 1,853,947 [949 GB]
Host Read Commands: 546,457
Host Write Commands: 32,200,509
Controller Busy Time: 20
Power Cycles: 33
Power On Hours: 2,232
Unsafe Shutdowns: 26
Media and Data Integrity Errors: 0
Error Information Log Entries: 0
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Error Information (NVMe Log 0x01, 16 of 63 entries)
No Errors Logged
Self-test Log (NVMe Log 0x06)
Self-test status: No self-test in progress
Num Test_Description Status Power_on_Hours Failing_LBA NSID Seg SCT Code
0 Short Completed without error 96 - - - - -
1 Extended Completed without error 96 - - - - -
2 Extended Completed without error 96 - - - - -
3 Short Aborted: Controller Reset 96 - - - - -
4 Short Aborted: Controller Reset 96 - - - - -

View File

@@ -0,0 +1,64 @@
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p8 amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: Sabrent
Serial Number: --
Firmware Version: RKT343.4
PCI Vendor/Subsystem ID: 0x1987
IEEE OUI Identifier: 0x6479a7
Total NVM Capacity: 512,110,190,592 [512 GB]
Unallocated NVM Capacity: 0
Controller ID: 1
NVMe Version: 1.3
Number of Namespaces: 1
Namespace 1 Size/Capacity: 512,110,190,592 [512 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Tue Jul 18 19:12:19 2023 EDT
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005d): Comp DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x08): Telmtry_Lg
Maximum Data Transfer Size: 512 Pages
Warning Comp. Temp. Threshold: 75 Celsius
Critical Comp. Temp. Threshold: 80 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 6.87W - - 0 0 0 0 0 0
1 + 5.15W - - 1 1 1 1 0 0
2 + 4.30W - - 2 2 2 2 0 0
3 - 0.0490W - - 3 3 3 3 2000 2000
4 - 0.0018W - - 4 4 4 4 25000 25000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 2
1 - 4096 0 1
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 49 Celsius
Available Spare: 100%
Available Spare Threshold: 5%
Percentage Used: 0%
Data Units Read: 11,878 [6.08 GB]
Data Units Written: 832,294 [426 GB]
Host Read Commands: 489,968
Host Write Commands: 51,887,076
Controller Busy Time: 16
Power Cycles: 31
Power On Hours: 839
Unsafe Shutdowns: 5
Media and Data Integrity Errors: 0
Error Information Log Entries: 0
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Error Information (NVMe Log 0x01, 16 of 63 entries)
No Errors Logged

View File

@@ -0,0 +1,66 @@
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: Viper M.2 VPN100
Serial Number: --
Firmware Version: ECFM22.6
PCI Vendor/Subsystem ID: 0x1987
IEEE OUI Identifier: 0x6479a7
Total NVM Capacity: 1,024,209,543,168 [1.02 TB]
Unallocated NVM Capacity: 0
Controller ID: 1
NVMe Version: 1.3
Number of Namespaces: 1
Namespace 1 Size/Capacity: 1,024,209,543,168 [1.02 TB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Thu Oct 12 13:57:34 2023 CEST
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005d): Comp DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x08): Telmtry_Lg
Maximum Data Transfer Size: 512 Pages
Warning Comp. Temp. Threshold: 75 Celsius
Critical Comp. Temp. Threshold: 80 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 7.13W - - 0 0 0 0 0 0
1 + 5.29W - - 1 1 1 1 0 0
2 + 4.36W - - 2 2 2 2 0 0
3 - 0.0490W - - 3 3 3 3 2000 2000
4 - 0.0018W - - 4 4 4 4 25000 25000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 2
1 - 4096 0 1
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 41 Celsius
Available Spare: 100%
Available Spare Threshold: 5%
Percentage Used: 28%
Data Units Read: 225,573,016 [115 TB]
Data Units Written: 157,475,903 [80.6 TB]
Host Read Commands: 8,623,297,058
Host Write Commands: 1,757,654,019
Controller Busy Time: 16,289
Power Cycles: 38,997
Power On Hours: 7,737
Unsafe Shutdowns: 437
Media and Data Integrity Errors: 0
Error Information Log Entries: 1,753
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Thermal Temp. 1 Transition Count: 1
Thermal Temp. 1 Total Time: 41
Error Information (NVMe Log 0x01, 16 of 63 entries)
No Errors Logged

View File

@@ -0,0 +1,65 @@
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p7 amd64] (local build)
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: YSO128GTLCW-E3C-2
Serial Number: --
Firmware Version: EDFMG1.5
PCI Vendor/Subsystem ID: 0x1987
IEEE OUI Identifier: 0x6479a7
Total NVM Capacity: 128,035,676,160 [128 GB]
Unallocated NVM Capacity: 0
Controller ID: 1
NVMe Version: 1.3
Number of Namespaces: 1
Namespace 1 Size/Capacity: 128,035,676,160 [128 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Thu Jun 22 21:16:20 2023 CEST
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x0056): Wr_Unc DS_Mngmt Sav/Sel_Feat Timestmp
Log Page Attributes (0x0a): Cmd_Eff_Lg Telmtry_Lg
Maximum Data Transfer Size: 64 Pages
Warning Comp. Temp. Threshold: 85 Celsius
Critical Comp. Temp. Threshold: 95 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 4.50W - - 0 0 0 0 0 0
1 + 2.70W - - 1 1 1 1 0 0
2 + 2.16W - - 2 2 2 2 0 0
3 - 0.0700W - - 3 3 3 3 1000 1000
4 - 0.0050W - - 4 4 4 4 5000 50000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 1
1 - 4096 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 50 Celsius
Available Spare: 100%
Available Spare Threshold: 5%
Percentage Used: 0%
Data Units Read: 1,876 [960 MB]
Data Units Written: 47,614 [24.3 GB]
Host Read Commands: 56,686
Host Write Commands: 675,800
Controller Busy Time: 0
Power Cycles: 6
Power On Hours: 12
Unsafe Shutdowns: 1
Media and Data Integrity Errors: 0
Error Information Log Entries: 0
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 67 Celsius
Error Information (NVMe Log 0x01, 16 of 16 entries)
No Errors Logged

View File

@@ -0,0 +1,69 @@
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p10 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: YSO128GTLCW-E3C-2
Serial Number: --
Firmware Version: EDFMG1.5
PCI Vendor/Subsystem ID: 0x1987
IEEE OUI Identifier: 0x6479a7
Total NVM Capacity: 128,035,676,160 [128 GB]
Unallocated NVM Capacity: 0
Controller ID: 1
NVMe Version: 1.3
Number of Namespaces: 1
Namespace 1 Size/Capacity: 128,035,676,160 [128 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Sat Mar 9 13:34:18 2024 CET
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x0056): Wr_Unc DS_Mngmt Sav/Sel_Feat Timestmp
Log Page Attributes (0x0a): Cmd_Eff_Lg Telmtry_Lg
Maximum Data Transfer Size: 64 Pages
Warning Comp. Temp. Threshold: 85 Celsius
Critical Comp. Temp. Threshold: 95 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 4.50W - - 0 0 0 0 0 0
1 + 2.70W - - 1 1 1 1 0 0
2 + 2.16W - - 2 2 2 2 0 0
3 - 0.0700W - - 3 3 3 3 1000 1000
4 - 0.0050W - - 4 4 4 4 5000 50000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 1
1 - 4096 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 50 Celsius
Available Spare: 100%
Available Spare Threshold: 5%
Percentage Used: 0%
Data Units Read: 28,885 [14.7 GB]
Data Units Written: 53,491 [27.3 GB]
Host Read Commands: 564,304
Host Write Commands: 756,782
Controller Busy Time: 1
Power Cycles: 39
Power On Hours: 114
Unsafe Shutdowns: 21
Media and Data Integrity Errors: 0
Error Information Log Entries: 0
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 67 Celsius
Error Information (NVMe Log 0x01, 16 of 16 entries)
No Errors Logged
Self-test Log (NVMe Log 0x06)
Self-test status: No self-test in progress
No Self-tests Logged

View File

@@ -0,0 +1,69 @@
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p11 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: YSO128GTLCW-E3C-2
Serial Number: --
Firmware Version: EDFMG1.5
PCI Vendor/Subsystem ID: 0x1987
IEEE OUI Identifier: 0x6479a7
Total NVM Capacity: 128,035,676,160 [128 GB]
Unallocated NVM Capacity: 0
Controller ID: 1
NVMe Version: 1.3
Number of Namespaces: 1
Namespace 1 Size/Capacity: 128,035,676,160 [128 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Sat May 4 10:51:55 2024 CEST
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x0056): Wr_Unc DS_Mngmt Sav/Sel_Feat Timestmp
Log Page Attributes (0x0a): Cmd_Eff_Lg Telmtry_Lg
Maximum Data Transfer Size: 64 Pages
Warning Comp. Temp. Threshold: 85 Celsius
Critical Comp. Temp. Threshold: 95 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 4.50W - - 0 0 0 0 0 0
1 + 2.70W - - 1 1 1 1 0 0
2 + 2.16W - - 2 2 2 2 0 0
3 - 0.0700W - - 3 3 3 3 1000 1000
4 - 0.0050W - - 4 4 4 4 5000 50000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 1
1 - 4096 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 57 Celsius
Available Spare: 100%
Available Spare Threshold: 5%
Percentage Used: 0%
Data Units Read: 28,905 [14.7 GB]
Data Units Written: 708,768 [362 GB]
Host Read Commands: 739,413
Host Write Commands: 11,614,944
Controller Busy Time: 10
Power Cycles: 16
Power On Hours: 761
Unsafe Shutdowns: 6
Media and Data Integrity Errors: 0
Error Information Log Entries: 0
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 76 Celsius
Error Information (NVMe Log 0x01, 16 of 16 entries)
No Errors Logged
Self-test Log (NVMe Log 0x06)
Self-test status: No self-test in progress
No Self-tests Logged

View File

@@ -0,0 +1,71 @@
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p11 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: YSO128GTLCW-E3C-2
Serial Number: --
Firmware Version: EDFMG1.5
PCI Vendor/Subsystem ID: 0x1987
IEEE OUI Identifier: 0x6479a7
Total NVM Capacity: 128,035,676,160 [128 GB]
Unallocated NVM Capacity: 0
Controller ID: 1
NVMe Version: 1.3
Number of Namespaces: 1
Namespace 1 Size/Capacity: 128,035,676,160 [128 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Wed Apr 10 16:26:41 2024 UTC
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x0056): Wr_Unc DS_Mngmt Sav/Sel_Feat Timestmp
Log Page Attributes (0x0a): Cmd_Eff_Lg Telmtry_Lg
Maximum Data Transfer Size: 64 Pages
Warning Comp. Temp. Threshold: 85 Celsius
Critical Comp. Temp. Threshold: 95 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 4.50W - - 0 0 0 0 0 0
1 + 2.70W - - 1 1 1 1 0 0
2 + 2.16W - - 2 2 2 2 0 0
3 - 0.0700W - - 3 3 3 3 1000 1000
4 - 0.0050W - - 4 4 4 4 5000 50000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 1
1 - 4096 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 59 Celsius
Available Spare: 100%
Available Spare Threshold: 5%
Percentage Used: 0%
Data Units Read: 6,291 [3.22 GB]
Data Units Written: 29,441 [15.0 GB]
Host Read Commands: 205,409
Host Write Commands: 816,975
Controller Busy Time: 0
Power Cycles: 31
Power On Hours: 59
Unsafe Shutdowns: 21
Media and Data Integrity Errors: 0
Error Information Log Entries: 0
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 78 Celsius
Error Information (NVMe Log 0x01, 16 of 16 entries)
No Errors Logged
Self-test Log (NVMe Log 0x06)
Self-test status: No self-test in progress
Num Test_Description Status Power_on_Hours Failing_LBA NSID Seg SCT Code
0 Extended Completed without error 57 - - - - -
1 Short Completed without error 57 - - - - -

View File

@@ -0,0 +1,69 @@
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p11 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: YSO128GTLCW-E3C-2
Serial Number: --
Firmware Version: EDFMG1.5
PCI Vendor/Subsystem ID: 0x1987
IEEE OUI Identifier: 0x6479a7
Total NVM Capacity: 128,035,676,160 [128 GB]
Unallocated NVM Capacity: 0
Controller ID: 1
NVMe Version: 1.3
Number of Namespaces: 1
Namespace 1 Size/Capacity: 128,035,676,160 [128 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Sat May 11 08:13:16 2024 ADT
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x0056): Wr_Unc DS_Mngmt Sav/Sel_Feat Timestmp
Log Page Attributes (0x0a): Cmd_Eff_Lg Telmtry_Lg
Maximum Data Transfer Size: 64 Pages
Warning Comp. Temp. Threshold: 85 Celsius
Critical Comp. Temp. Threshold: 95 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 4.50W - - 0 0 0 0 0 0
1 + 2.70W - - 1 1 1 1 0 0
2 + 2.16W - - 2 2 2 2 0 0
3 - 0.0700W - - 3 3 3 3 1000 1000
4 - 0.0050W - - 4 4 4 4 5000 50000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 1
1 - 4096 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 51 Celsius
Available Spare: 100%
Available Spare Threshold: 5%
Percentage Used: 0%
Data Units Read: 24,072 [12.3 GB]
Data Units Written: 77,037 [39.4 GB]
Host Read Commands: 472,738
Host Write Commands: 1,207,479
Controller Busy Time: 1
Power Cycles: 19
Power On Hours: 13
Unsafe Shutdowns: 9
Media and Data Integrity Errors: 0
Error Information Log Entries: 0
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 69 Celsius
Error Information (NVMe Log 0x01, 16 of 16 entries)
No Errors Logged
Self-test Log (NVMe Log 0x06)
Self-test status: No self-test in progress
No Self-tests Logged

View File

@@ -0,0 +1,69 @@
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p11 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: YSO128GTLCW-E3C-2
Serial Number: --
Firmware Version: EDFMG1.5
PCI Vendor/Subsystem ID: 0x1987
IEEE OUI Identifier: 0x6479a7
Total NVM Capacity: 128,035,676,160 [128 GB]
Unallocated NVM Capacity: 0
Controller ID: 1
NVMe Version: 1.3
Number of Namespaces: 1
Namespace 1 Size/Capacity: 128,035,676,160 [128 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Fri Apr 19 10:24:50 2024 CEST
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x0056): Wr_Unc DS_Mngmt Sav/Sel_Feat Timestmp
Log Page Attributes (0x0a): Cmd_Eff_Lg Telmtry_Lg
Maximum Data Transfer Size: 64 Pages
Warning Comp. Temp. Threshold: 85 Celsius
Critical Comp. Temp. Threshold: 95 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 4.50W - - 0 0 0 0 0 0
1 + 2.70W - - 1 1 1 1 0 0
2 + 2.16W - - 2 2 2 2 0 0
3 - 0.0700W - - 3 3 3 3 1000 1000
4 - 0.0050W - - 4 4 4 4 5000 50000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 1
1 - 4096 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 54 Celsius
Available Spare: 100%
Available Spare Threshold: 5%
Percentage Used: 0%
Data Units Read: 3,006 [1.53 GB]
Data Units Written: 6,970 [3.56 GB]
Host Read Commands: 75,232
Host Write Commands: 170,259
Controller Busy Time: 0
Power Cycles: 12
Power On Hours: 20
Unsafe Shutdowns: 10
Media and Data Integrity Errors: 0
Error Information Log Entries: 0
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 73 Celsius
Error Information (NVMe Log 0x01, 16 of 16 entries)
No Errors Logged
Self-test Log (NVMe Log 0x06)
Self-test status: No self-test in progress
No Self-tests Logged

View File

@@ -0,0 +1,69 @@
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p10 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: YSO128GTLCW-E3C-2
Serial Number: --
Firmware Version: EDFMG1.5
PCI Vendor/Subsystem ID: 0x1987
IEEE OUI Identifier: 0x6479a7
Total NVM Capacity: 128,035,676,160 [128 GB]
Unallocated NVM Capacity: 0
Controller ID: 1
NVMe Version: 1.3
Number of Namespaces: 1
Namespace 1 Size/Capacity: 128,035,676,160 [128 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Fri Mar 29 14:50:38 2024 CET
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x0056): Wr_Unc DS_Mngmt Sav/Sel_Feat Timestmp
Log Page Attributes (0x0a): Cmd_Eff_Lg Telmtry_Lg
Maximum Data Transfer Size: 64 Pages
Warning Comp. Temp. Threshold: 85 Celsius
Critical Comp. Temp. Threshold: 95 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 4.50W - - 0 0 0 0 0 0
1 + 2.70W - - 1 1 1 1 0 0
2 + 2.16W - - 2 2 2 2 0 0
3 - 0.0700W - - 3 3 3 3 1000 1000
4 - 0.0050W - - 4 4 4 4 5000 50000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 1
1 - 4096 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 50 Celsius
Available Spare: 100%
Available Spare Threshold: 5%
Percentage Used: 0%
Data Units Read: 9,583 [4.90 GB]
Data Units Written: 49,437 [25.3 GB]
Host Read Commands: 311,100
Host Write Commands: 1,566,151
Controller Busy Time: 2
Power Cycles: 19
Power On Hours: 167
Unsafe Shutdowns: 4
Media and Data Integrity Errors: 0
Error Information Log Entries: 0
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 68 Celsius
Error Information (NVMe Log 0x01, 16 of 16 entries)
No Errors Logged
Self-test Log (NVMe Log 0x06)
Self-test status: No self-test in progress
No Self-tests Logged

View File

@@ -0,0 +1,69 @@
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p11 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: YSO256GTLCW-E3C-2
Serial Number: --
Firmware Version: EDFMG1.5
PCI Vendor/Subsystem ID: 0x1987
IEEE OUI Identifier: 0x6479a7
Total NVM Capacity: 256,060,514,304 [256 GB]
Unallocated NVM Capacity: 0
Controller ID: 1
NVMe Version: 1.3
Number of Namespaces: 1
Namespace 1 Size/Capacity: 256,060,514,304 [256 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Sat Apr 13 14:08:35 2024 CEST
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x0056): Wr_Unc DS_Mngmt Sav/Sel_Feat Timestmp
Log Page Attributes (0x0a): Cmd_Eff_Lg Telmtry_Lg
Maximum Data Transfer Size: 64 Pages
Warning Comp. Temp. Threshold: 85 Celsius
Critical Comp. Temp. Threshold: 95 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 4.50W - - 0 0 0 0 0 0
1 + 2.70W - - 1 1 1 1 0 0
2 + 2.16W - - 2 2 2 2 0 0
3 - 0.0700W - - 3 3 3 3 1000 1000
4 - 0.0050W - - 4 4 4 4 5000 50000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 1
1 - 4096 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 58 Celsius
Available Spare: 100%
Available Spare Threshold: 5%
Percentage Used: 0%
Data Units Read: 18,618 [9.53 GB]
Data Units Written: 47,174 [24.1 GB]
Host Read Commands: 290,235
Host Write Commands: 801,075
Controller Busy Time: 0
Power Cycles: 16
Power On Hours: 20
Unsafe Shutdowns: 12
Media and Data Integrity Errors: 0
Error Information Log Entries: 0
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 77 Celsius
Error Information (NVMe Log 0x01, 16 of 16 entries)
No Errors Logged
Self-test Log (NVMe Log 0x06)
Self-test status: No self-test in progress
No Self-tests Logged

View File

@@ -0,0 +1,69 @@
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p11 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: YSO256GTLCW-E3C-2
Serial Number: --
Firmware Version: EDFMG1.5
PCI Vendor/Subsystem ID: 0x1987
IEEE OUI Identifier: 0x6479a7
Total NVM Capacity: 256,060,514,304 [256 GB]
Unallocated NVM Capacity: 0
Controller ID: 1
NVMe Version: 1.3
Number of Namespaces: 1
Namespace 1 Size/Capacity: 256,060,514,304 [256 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Thu Jul 18 13:25:26 2024 JST
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x0056): Wr_Unc DS_Mngmt Sav/Sel_Feat Timestmp
Log Page Attributes (0x0a): Cmd_Eff_Lg Telmtry_Lg
Maximum Data Transfer Size: 64 Pages
Warning Comp. Temp. Threshold: 85 Celsius
Critical Comp. Temp. Threshold: 95 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 4.50W - - 0 0 0 0 0 0
1 + 2.70W - - 1 1 1 1 0 0
2 + 2.16W - - 2 2 2 2 0 0
3 - 0.0700W - - 3 3 3 3 1000 1000
4 - 0.0050W - - 4 4 4 4 5000 50000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 1
1 - 4096 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 50 Celsius
Available Spare: 100%
Available Spare Threshold: 5%
Percentage Used: 0%
Data Units Read: 63,808 [32.6 GB]
Data Units Written: 111,892 [57.2 GB]
Host Read Commands: 992,773
Host Write Commands: 1,808,838
Controller Busy Time: 5
Power Cycles: 33
Power On Hours: 146
Unsafe Shutdowns: 17
Media and Data Integrity Errors: 0
Error Information Log Entries: 0
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 67 Celsius
Error Information (NVMe Log 0x01, 16 of 16 entries)
No Errors Logged
Self-test Log (NVMe Log 0x06)
Self-test status: No self-test in progress
No Self-tests Logged

View File

@@ -0,0 +1,69 @@
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p9 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: YSO256GTLCW-E3C-2
Serial Number: --
Firmware Version: EDFMG1.5
PCI Vendor/Subsystem ID: 0x1987
IEEE OUI Identifier: 0x6479a7
Total NVM Capacity: 256,060,514,304 [256 GB]
Unallocated NVM Capacity: 0
Controller ID: 1
NVMe Version: 1.3
Number of Namespaces: 1
Namespace 1 Size/Capacity: 256,060,514,304 [256 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Tue Feb 20 14:50:33 2024 +08
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x0056): Wr_Unc DS_Mngmt Sav/Sel_Feat Timestmp
Log Page Attributes (0x0a): Cmd_Eff_Lg Telmtry_Lg
Maximum Data Transfer Size: 64 Pages
Warning Comp. Temp. Threshold: 85 Celsius
Critical Comp. Temp. Threshold: 95 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 4.50W - - 0 0 0 0 0 0
1 + 2.70W - - 1 1 1 1 0 0
2 + 2.16W - - 2 2 2 2 0 0
3 - 0.0700W - - 3 3 3 3 1000 1000
4 - 0.0050W - - 4 4 4 4 5000 50000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 1
1 - 4096 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 64 Celsius
Available Spare: 100%
Available Spare Threshold: 5%
Percentage Used: 0%
Data Units Read: 84,400 [43.2 GB]
Data Units Written: 1,483,992 [759 GB]
Host Read Commands: 1,398,625
Host Write Commands: 57,215,753
Controller Busy Time: 135
Power Cycles: 54
Power On Hours: 1,054
Unsafe Shutdowns: 30
Media and Data Integrity Errors: 0
Error Information Log Entries: 0
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 85 Celsius
Error Information (NVMe Log 0x01, 16 of 16 entries)
No Errors Logged
Self-test Log (NVMe Log 0x06)
Self-test status: No self-test in progress
No Self-tests Logged

View File

@@ -0,0 +1,69 @@
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p11 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: YSO256GTLCW-E3C-2
Serial Number: --
Firmware Version: EDFMG1.5
PCI Vendor/Subsystem ID: 0x1987
IEEE OUI Identifier: 0x6479a7
Total NVM Capacity: 256,060,514,304 [256 GB]
Unallocated NVM Capacity: 0
Controller ID: 1
NVMe Version: 1.3
Number of Namespaces: 1
Namespace 1 Size/Capacity: 256,060,514,304 [256 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Wed Apr 17 15:02:01 2024 UTC
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x0056): Wr_Unc DS_Mngmt Sav/Sel_Feat Timestmp
Log Page Attributes (0x0a): Cmd_Eff_Lg Telmtry_Lg
Maximum Data Transfer Size: 64 Pages
Warning Comp. Temp. Threshold: 85 Celsius
Critical Comp. Temp. Threshold: 95 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 4.50W - - 0 0 0 0 0 0
1 + 2.70W - - 1 1 1 1 0 0
2 + 2.16W - - 2 2 2 2 0 0
3 - 0.0700W - - 3 3 3 3 1000 1000
4 - 0.0050W - - 4 4 4 4 5000 50000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 1
1 - 4096 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 43 Celsius
Available Spare: 100%
Available Spare Threshold: 5%
Percentage Used: 0%
Data Units Read: 7,563 [3.87 GB]
Data Units Written: 21,969 [11.2 GB]
Host Read Commands: 137,947
Host Write Commands: 478,733
Controller Busy Time: 0
Power Cycles: 16
Power On Hours: 3
Unsafe Shutdowns: 9
Media and Data Integrity Errors: 0
Error Information Log Entries: 0
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 59 Celsius
Error Information (NVMe Log 0x01, 16 of 16 entries)
No Errors Logged
Self-test Log (NVMe Log 0x06)
Self-test status: No self-test in progress
No Self-tests Logged

View File

@@ -0,0 +1,69 @@
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p3 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: YSO256GTLCW-E3C-2
Serial Number: --
Firmware Version: EDFMG1.5
PCI Vendor/Subsystem ID: 0x1987
IEEE OUI Identifier: 0x6479a7
Total NVM Capacity: 256,060,514,304 [256 GB]
Unallocated NVM Capacity: 0
Controller ID: 1
NVMe Version: 1.3
Number of Namespaces: 1
Namespace 1 Size/Capacity: 256,060,514,304 [256 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Tue Oct 17 01:53:02 2023 CEST
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x0056): Wr_Unc DS_Mngmt Sav/Sel_Feat Timestmp
Log Page Attributes (0x0a): Cmd_Eff_Lg Telmtry_Lg
Maximum Data Transfer Size: 64 Pages
Warning Comp. Temp. Threshold: 85 Celsius
Critical Comp. Temp. Threshold: 95 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 4.50W - - 0 0 0 0 0 0
1 + 2.70W - - 1 1 1 1 0 0
2 + 2.16W - - 2 2 2 2 0 0
3 - 0.0700W - - 3 3 3 3 1000 1000
4 - 0.0050W - - 4 4 4 4 5000 50000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 1
1 - 4096 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 37 Celsius
Available Spare: 100%
Available Spare Threshold: 5%
Percentage Used: 0%
Data Units Read: 27,199 [13.9 GB]
Data Units Written: 56,907 [29.1 GB]
Host Read Commands: 485,106
Host Write Commands: 643,373
Controller Busy Time: 1
Power Cycles: 35
Power On Hours: 21
Unsafe Shutdowns: 15
Media and Data Integrity Errors: 0
Error Information Log Entries: 0
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 52 Celsius
Error Information (NVMe Log 0x01, 16 of 16 entries)
No Errors Logged
Self-test Log (NVMe Log 0x06)
Self-test status: No self-test in progress
No Self-tests Logged

View File

@@ -0,0 +1,71 @@
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p10 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: YSR128GMLCC-E3C-2
Serial Number: --
Firmware Version: EDFM21.0
PCI Vendor/Subsystem ID: 0x1987
IEEE OUI Identifier: 0x6479a7
Total NVM Capacity: 128,035,676,160 [128 GB]
Unallocated NVM Capacity: 0
Controller ID: 1
NVMe Version: 1.3
Number of Namespaces: 1
Namespace 1 Size/Capacity: 128,035,676,160 [128 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Tue Apr 2 19:36:09 2024 EDT
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005e): Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x0a): Cmd_Eff_Lg Telmtry_Lg
Maximum Data Transfer Size: 64 Pages
Warning Comp. Temp. Threshold: 70 Celsius
Critical Comp. Temp. Threshold: 80 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 4.50W - - 0 0 0 0 0 0
1 + 2.70W - - 1 1 1 1 0 0
2 + 2.16W - - 2 2 2 2 0 0
3 - 0.0700W - - 3 3 3 3 1000 1000
4 - 0.0050W - - 4 4 4 4 5000 100000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 1
1 - 4096 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 44 Celsius
Available Spare: 100%
Available Spare Threshold: 5%
Percentage Used: 15%
Data Units Read: 83,358 [42.6 GB]
Data Units Written: 13,042,897 [6.67 TB]
Host Read Commands: 3,574,391
Host Write Commands: 675,101,222
Controller Busy Time: 1,091
Power Cycles: 49
Power On Hours: 10,680
Unsafe Shutdowns: 36
Media and Data Integrity Errors: 0
Error Information Log Entries: 16
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 61 Celsius
Thermal Temp. 1 Transition Count: 1
Thermal Temp. 1 Total Time: 92
Error Information (NVMe Log 0x01, 16 of 16 entries)
No Errors Logged
Self-test Log (NVMe Log 0x06)
Self-test status: No self-test in progress
No Self-tests Logged

View File

@@ -0,0 +1,71 @@
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p7 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Model Number: YSR256GMLCT-E3C-2
Serial Number: --
Firmware Version: EDFM90.1
PCI Vendor/Subsystem ID: 0x1987
IEEE OUI Identifier: 0x6479a7
Total NVM Capacity: 256,060,514,304 [256 GB]
Unallocated NVM Capacity: 0
Controller ID: 1
NVMe Version: 1.3
Number of Namespaces: 1
Namespace 1 Size/Capacity: 256,060,514,304 [256 GB]
Namespace 1 Formatted LBA Size: 512
Namespace 1 IEEE EUI-64: 6479a7 ...
Local Time is: Wed May 1 14:10:55 2024 EEST
Firmware Updates (0x12): 1 Slot, no Reset required
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
Optional NVM Commands (0x005e): Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
Log Page Attributes (0x0a): Cmd_Eff_Lg Telmtry_Lg
Maximum Data Transfer Size: 64 Pages
Warning Comp. Temp. Threshold: 85 Celsius
Critical Comp. Temp. Threshold: 95 Celsius
Supported Power States
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
0 + 4.50W - - 0 0 0 0 0 0
1 + 2.70W - - 1 1 1 1 0 0
2 + 2.16W - - 2 2 2 2 0 0
3 - 0.0700W - - 3 3 3 3 5000 1900
4 - 0.0050W - - 4 4 4 4 13000 100000
Supported LBA Sizes (NSID 0x1)
Id Fmt Data Metadt Rel_Perf
0 + 512 0 1
1 - 4096 0 0
=== START OF SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
SMART/Health Information (NVMe Log 0x02)
Critical Warning: 0x00
Temperature: 57 Celsius
Available Spare: 100%
Available Spare Threshold: 5%
Percentage Used: 2%
Data Units Read: 53,848 [27.5 GB]
Data Units Written: 3,622,275 [1.85 TB]
Host Read Commands: 897,186
Host Write Commands: 302,128,480
Controller Busy Time: 666
Power Cycles: 36
Power On Hours: 5,306
Unsafe Shutdowns: 17
Media and Data Integrity Errors: 0
Error Information Log Entries: 0
Warning Comp. Temperature Time: 0
Critical Comp. Temperature Time: 0
Temperature Sensor 1: 74 Celsius
Error Information (NVMe Log 0x01, 16 of 16 entries)
No Errors Logged
Self-test Log (NVMe Log 0x06)
Self-test status: No self-test in progress
No Self-tests Logged