mirror of
https://github.com/bsdhw/SMART.git
synced 2025-05-31 16:21:41 +05:30
Update of reports (new: 6895, modified: 16)
This commit is contained in:
64
NVMe/Team/TM8/TM8FP4001T/73E05B6FC46B
Normal file
64
NVMe/Team/TM8/TM8FP4001T/73E05B6FC46B
Normal file
@@ -0,0 +1,64 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p9 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Number: TEAM TM8FP4001T
|
||||
Serial Number: --
|
||||
Firmware Version: VB421D65
|
||||
PCI Vendor/Subsystem ID: 0x10ec
|
||||
IEEE OUI Identifier: 0x00e04c
|
||||
Controller ID: 1
|
||||
NVMe Version: 1.3
|
||||
Number of Namespaces: 1
|
||||
Namespace 1 Size/Capacity: 1,024,209,543,168 [1.02 TB]
|
||||
Namespace 1 Formatted LBA Size: 512
|
||||
Local Time is: Sat Feb 17 22:30:38 2024 UTC
|
||||
Firmware Updates (0x02): 1 Slot
|
||||
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
|
||||
Optional NVM Commands (0x0014): DS_Mngmt Sav/Sel_Feat
|
||||
Log Page Attributes (0x02): Cmd_Eff_Lg
|
||||
Maximum Data Transfer Size: 32 Pages
|
||||
Warning Comp. Temp. Threshold: 100 Celsius
|
||||
Critical Comp. Temp. Threshold: 110 Celsius
|
||||
|
||||
Supported Power States
|
||||
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
|
||||
0 + 8.00W - - 0 0 0 0 230000 50000
|
||||
1 + 4.00W - - 1 1 1 1 4000 50000
|
||||
2 + 3.00W - - 2 2 2 2 4000 250000
|
||||
3 - 0.50W - - 3 3 3 3 4000 8000
|
||||
4 - 0.0090W - - 4 4 4 4 8000 30000
|
||||
|
||||
Supported LBA Sizes (NSID 0x1)
|
||||
Id Fmt Data Metadt Rel_Perf
|
||||
0 + 512 0 0
|
||||
|
||||
=== START OF SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
SMART/Health Information (NVMe Log 0x02)
|
||||
Critical Warning: 0x00
|
||||
Temperature: 37 Celsius
|
||||
Available Spare: 100%
|
||||
Available Spare Threshold: 32%
|
||||
Percentage Used: 0%
|
||||
Data Units Read: 16,920,839 [8.66 TB]
|
||||
Data Units Written: 26,829,155 [13.7 TB]
|
||||
Host Read Commands: 94,033,549
|
||||
Host Write Commands: 200,319,543
|
||||
Controller Busy Time: 0
|
||||
Power Cycles: 120
|
||||
Power On Hours: 3,139
|
||||
Unsafe Shutdowns: 60
|
||||
Media and Data Integrity Errors: 0
|
||||
Error Information Log Entries: 0
|
||||
Warning Comp. Temperature Time: 0
|
||||
Critical Comp. Temperature Time: 0
|
||||
|
||||
Error Information (NVMe Log 0x01, 8 of 8 entries)
|
||||
No Errors Logged
|
||||
|
||||
Self-test Log (NVMe Log 0x06)
|
||||
Self-test status: No self-test in progress
|
||||
No Self-tests Logged
|
||||
|
66
NVMe/Team/TM8/TM8FP4001T/F93E92500F3A
Normal file
66
NVMe/Team/TM8/TM8FP4001T/F93E92500F3A
Normal file
@@ -0,0 +1,66 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p9 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Number: TEAM TM8FP4001T
|
||||
Serial Number: --
|
||||
Firmware Version: VB421D65
|
||||
PCI Vendor/Subsystem ID: 0x10ec
|
||||
IEEE OUI Identifier: 0x00e04c
|
||||
Controller ID: 1
|
||||
NVMe Version: 1.3
|
||||
Number of Namespaces: 1
|
||||
Namespace 1 Size/Capacity: 1,024,209,543,168 [1.02 TB]
|
||||
Namespace 1 Formatted LBA Size: 512
|
||||
Local Time is: Sat Feb 17 22:30:38 2024 UTC
|
||||
Firmware Updates (0x02): 1 Slot
|
||||
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
|
||||
Optional NVM Commands (0x0014): DS_Mngmt Sav/Sel_Feat
|
||||
Log Page Attributes (0x02): Cmd_Eff_Lg
|
||||
Maximum Data Transfer Size: 32 Pages
|
||||
Warning Comp. Temp. Threshold: 100 Celsius
|
||||
Critical Comp. Temp. Threshold: 110 Celsius
|
||||
|
||||
Supported Power States
|
||||
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
|
||||
0 + 8.00W - - 0 0 0 0 230000 50000
|
||||
1 + 4.00W - - 1 1 1 1 4000 50000
|
||||
2 + 3.00W - - 2 2 2 2 4000 250000
|
||||
3 - 0.50W - - 3 3 3 3 4000 8000
|
||||
4 - 0.0090W - - 4 4 4 4 8000 30000
|
||||
|
||||
Supported LBA Sizes (NSID 0x1)
|
||||
Id Fmt Data Metadt Rel_Perf
|
||||
0 + 512 0 0
|
||||
|
||||
=== START OF SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
SMART/Health Information (NVMe Log 0x02)
|
||||
Critical Warning: 0x00
|
||||
Temperature: 56 Celsius
|
||||
Available Spare: 100%
|
||||
Available Spare Threshold: 32%
|
||||
Percentage Used: 0%
|
||||
Data Units Read: 16,635,511 [8.51 TB]
|
||||
Data Units Written: 26,700,127 [13.6 TB]
|
||||
Host Read Commands: 92,542,124
|
||||
Host Write Commands: 198,843,880
|
||||
Controller Busy Time: 0
|
||||
Power Cycles: 120
|
||||
Power On Hours: 3,185
|
||||
Unsafe Shutdowns: 60
|
||||
Media and Data Integrity Errors: 0
|
||||
Error Information Log Entries: 0
|
||||
Warning Comp. Temperature Time: 0
|
||||
Critical Comp. Temperature Time: 0
|
||||
|
||||
Error Information (NVMe Log 0x01, 8 of 8 entries)
|
||||
No Errors Logged
|
||||
|
||||
Self-test Log (NVMe Log 0x06)
|
||||
Self-test status: No self-test in progress
|
||||
No Self-tests Logged
|
||||
|
||||
|
||||
|
71
NVMe/Team/TM8/TM8FP6128G/1B1A2BDC66F7
Normal file
71
NVMe/Team/TM8/TM8FP6128G/1B1A2BDC66F7
Normal file
@@ -0,0 +1,71 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p5 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Number: TEAM TM8FP6128G
|
||||
Serial Number: --
|
||||
Firmware Version: T1103F0L
|
||||
PCI Vendor/Subsystem ID: 0x126f
|
||||
IEEE OUI Identifier: 0x000001
|
||||
Total NVM Capacity: 128,035,676,160 [128 GB]
|
||||
Unallocated NVM Capacity: 0
|
||||
Controller ID: 1
|
||||
NVMe Version: 1.3
|
||||
Number of Namespaces: 1
|
||||
Namespace 1 Size/Capacity: 128,035,676,160 [128 GB]
|
||||
Namespace 1 Formatted LBA Size: 512
|
||||
Namespace 1 IEEE EUI-64: 000001 ...
|
||||
Local Time is: Sat Dec 9 19:28:37 2023 EST
|
||||
Firmware Updates (0x12): 1 Slot, no Reset required
|
||||
Optional Admin Commands (0x0007): Security Format Frmw_DL
|
||||
Optional NVM Commands (0x0014): DS_Mngmt Sav/Sel_Feat
|
||||
Log Page Attributes (0x03): S/H_per_NS Cmd_Eff_Lg
|
||||
Maximum Data Transfer Size: 64 Pages
|
||||
Warning Comp. Temp. Threshold: 83 Celsius
|
||||
Critical Comp. Temp. Threshold: 85 Celsius
|
||||
|
||||
Supported Power States
|
||||
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
|
||||
0 + 6.00W - - 0 0 0 0 0 0
|
||||
1 + 3.00W - - 1 1 1 1 0 0
|
||||
2 + 1.50W - - 2 2 2 2 0 0
|
||||
3 - 0.0450W - - 3 3 3 3 3000 3000
|
||||
4 - 0.0040W - - 4 4 4 4 25000 25000
|
||||
|
||||
Supported LBA Sizes (NSID 0x1)
|
||||
Id Fmt Data Metadt Rel_Perf
|
||||
0 + 512 0 0
|
||||
|
||||
=== START OF SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
SMART/Health Information (NVMe Log 0x02)
|
||||
Critical Warning: 0x00
|
||||
Temperature: 46 Celsius
|
||||
Available Spare: 100%
|
||||
Available Spare Threshold: 10%
|
||||
Percentage Used: 4%
|
||||
Data Units Read: 2,489,241 [1.27 TB]
|
||||
Data Units Written: 15,515,181 [7.94 TB]
|
||||
Host Read Commands: 20,483,718
|
||||
Host Write Commands: 783,811,550
|
||||
Controller Busy Time: 5,144
|
||||
Power Cycles: 175
|
||||
Power On Hours: 12,033
|
||||
Unsafe Shutdowns: 66
|
||||
Media and Data Integrity Errors: 0
|
||||
Error Information Log Entries: 0
|
||||
Warning Comp. Temperature Time: 4
|
||||
Critical Comp. Temperature Time: 8
|
||||
Thermal Temp. 1 Transition Count: 1
|
||||
Thermal Temp. 2 Transition Count: 3
|
||||
Thermal Temp. 1 Total Time: 102
|
||||
Thermal Temp. 2 Total Time: 300
|
||||
|
||||
Error Information (NVMe Log 0x01, 16 of 64 entries)
|
||||
No Errors Logged
|
||||
|
||||
Self-tests not supported
|
||||
|
||||
|
||||
|
69
NVMe/Team/TM8/TM8FP6128G/9DEDECE88F60
Normal file
69
NVMe/Team/TM8/TM8FP6128G/9DEDECE88F60
Normal file
@@ -0,0 +1,69 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p5 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Number: TEAM TM8FP6128G
|
||||
Serial Number: --
|
||||
Firmware Version: T1103F0L
|
||||
PCI Vendor/Subsystem ID: 0x126f
|
||||
IEEE OUI Identifier: 0x000001
|
||||
Total NVM Capacity: 128,035,676,160 [128 GB]
|
||||
Unallocated NVM Capacity: 0
|
||||
Controller ID: 1
|
||||
NVMe Version: 1.3
|
||||
Number of Namespaces: 1
|
||||
Namespace 1 Size/Capacity: 128,035,676,160 [128 GB]
|
||||
Namespace 1 Formatted LBA Size: 512
|
||||
Namespace 1 IEEE EUI-64: 000001 ...
|
||||
Local Time is: Sat Dec 9 19:28:37 2023 EST
|
||||
Firmware Updates (0x12): 1 Slot, no Reset required
|
||||
Optional Admin Commands (0x0007): Security Format Frmw_DL
|
||||
Optional NVM Commands (0x0014): DS_Mngmt Sav/Sel_Feat
|
||||
Log Page Attributes (0x03): S/H_per_NS Cmd_Eff_Lg
|
||||
Maximum Data Transfer Size: 64 Pages
|
||||
Warning Comp. Temp. Threshold: 83 Celsius
|
||||
Critical Comp. Temp. Threshold: 85 Celsius
|
||||
|
||||
Supported Power States
|
||||
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
|
||||
0 + 6.00W - - 0 0 0 0 0 0
|
||||
1 + 3.00W - - 1 1 1 1 0 0
|
||||
2 + 1.50W - - 2 2 2 2 0 0
|
||||
3 - 0.0450W - - 3 3 3 3 3000 3000
|
||||
4 - 0.0040W - - 4 4 4 4 25000 25000
|
||||
|
||||
Supported LBA Sizes (NSID 0x1)
|
||||
Id Fmt Data Metadt Rel_Perf
|
||||
0 + 512 0 0
|
||||
|
||||
=== START OF SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
SMART/Health Information (NVMe Log 0x02)
|
||||
Critical Warning: 0x00
|
||||
Temperature: 53 Celsius
|
||||
Available Spare: 100%
|
||||
Available Spare Threshold: 10%
|
||||
Percentage Used: 4%
|
||||
Data Units Read: 1,735,701 [888 GB]
|
||||
Data Units Written: 15,558,128 [7.96 TB]
|
||||
Host Read Commands: 14,050,671
|
||||
Host Write Commands: 759,279,999
|
||||
Controller Busy Time: 4,509
|
||||
Power Cycles: 175
|
||||
Power On Hours: 11,995
|
||||
Unsafe Shutdowns: 66
|
||||
Media and Data Integrity Errors: 0
|
||||
Error Information Log Entries: 0
|
||||
Warning Comp. Temperature Time: 3
|
||||
Critical Comp. Temperature Time: 9
|
||||
Thermal Temp. 1 Transition Count: 1
|
||||
Thermal Temp. 2 Transition Count: 3
|
||||
Thermal Temp. 1 Total Time: 99
|
||||
Thermal Temp. 2 Total Time: 236
|
||||
|
||||
Error Information (NVMe Log 0x01, 16 of 64 entries)
|
||||
No Errors Logged
|
||||
|
||||
Self-tests not supported
|
||||
|
65
NVMe/Team/TM8/TM8FP6256G/04BEBDB98520
Normal file
65
NVMe/Team/TM8/TM8FP6256G/04BEBDB98520
Normal file
@@ -0,0 +1,65 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p5 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Number: TEAM TM8FP6256G
|
||||
Serial Number: --
|
||||
Firmware Version: VC2S038E
|
||||
PCI Vendor/Subsystem ID: 0x10ec
|
||||
IEEE OUI Identifier: 0x00e04c
|
||||
Controller ID: 1
|
||||
NVMe Version: 1.4
|
||||
Number of Namespaces: 1
|
||||
Namespace 1 Size/Capacity: 256,060,514,304 [256 GB]
|
||||
Namespace 1 Formatted LBA Size: 512
|
||||
Namespace 1 IEEE EUI-64: 00e04c ...
|
||||
Local Time is: Mon Dec 4 19:56:58 2023 CST
|
||||
Firmware Updates (0x02): 1 Slot
|
||||
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
|
||||
Optional NVM Commands (0x005e): Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
|
||||
Log Page Attributes (0x02): Cmd_Eff_Lg
|
||||
Maximum Data Transfer Size: 32 Pages
|
||||
Warning Comp. Temp. Threshold: 100 Celsius
|
||||
Critical Comp. Temp. Threshold: 110 Celsius
|
||||
|
||||
Supported Power States
|
||||
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
|
||||
0 + 8.00W - - 0 0 0 0 230000 50000
|
||||
1 + 4.00W - - 1 1 1 1 4000 50000
|
||||
2 + 3.00W - - 2 2 2 2 4000 250000
|
||||
3 - 0.0300W - - 3 3 3 3 5000 10000
|
||||
4 - 0.0050W - - 4 4 4 4 54000 45000
|
||||
|
||||
Supported LBA Sizes (NSID 0x1)
|
||||
Id Fmt Data Metadt Rel_Perf
|
||||
0 + 512 0 0
|
||||
|
||||
=== START OF SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
SMART/Health Information (NVMe Log 0x02)
|
||||
Critical Warning: 0x00
|
||||
Temperature: 54 Celsius
|
||||
Available Spare: 100%
|
||||
Available Spare Threshold: 32%
|
||||
Percentage Used: 0%
|
||||
Data Units Read: 325,362 [166 GB]
|
||||
Data Units Written: 344,907 [176 GB]
|
||||
Host Read Commands: 1,397,929
|
||||
Host Write Commands: 2,157,003
|
||||
Controller Busy Time: 0
|
||||
Power Cycles: 20
|
||||
Power On Hours: 22
|
||||
Unsafe Shutdowns: 4
|
||||
Media and Data Integrity Errors: 0
|
||||
Error Information Log Entries: 0
|
||||
Warning Comp. Temperature Time: 0
|
||||
Critical Comp. Temperature Time: 0
|
||||
|
||||
Error Information (NVMe Log 0x01, 8 of 8 entries)
|
||||
No Errors Logged
|
||||
|
||||
Self-test Log (NVMe Log 0x06)
|
||||
Self-test status: No self-test in progress
|
||||
No Self-tests Logged
|
||||
|
65
NVMe/Team/TM8/TM8FP6256G/06A905014D59
Normal file
65
NVMe/Team/TM8/TM8FP6256G/06A905014D59
Normal file
@@ -0,0 +1,65 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p2 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Number: TEAM TM8FP6256G
|
||||
Serial Number: --
|
||||
Firmware Version: VC2S038C
|
||||
PCI Vendor/Subsystem ID: 0x10ec
|
||||
IEEE OUI Identifier: 0x00e04c
|
||||
Controller ID: 1
|
||||
NVMe Version: 1.4
|
||||
Number of Namespaces: 1
|
||||
Namespace 1 Size/Capacity: 256,060,514,304 [256 GB]
|
||||
Namespace 1 Formatted LBA Size: 512
|
||||
Namespace 1 IEEE EUI-64: 00e04c ...
|
||||
Local Time is: Sat Sep 2 03:54:57 2023 EDT
|
||||
Firmware Updates (0x02): 1 Slot
|
||||
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
|
||||
Optional NVM Commands (0x0054): DS_Mngmt Sav/Sel_Feat Timestmp
|
||||
Log Page Attributes (0x02): Cmd_Eff_Lg
|
||||
Maximum Data Transfer Size: 32 Pages
|
||||
Warning Comp. Temp. Threshold: 100 Celsius
|
||||
Critical Comp. Temp. Threshold: 110 Celsius
|
||||
|
||||
Supported Power States
|
||||
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
|
||||
0 + 8.00W - - 0 0 0 0 0 0
|
||||
1 + 4.00W - - 1 1 1 1 0 0
|
||||
2 + 3.00W - - 2 2 2 2 0 0
|
||||
3 - 0.0300W - - 3 3 3 3 5000 10000
|
||||
4 - 0.0050W - - 4 4 4 4 54000 45000
|
||||
|
||||
Supported LBA Sizes (NSID 0x1)
|
||||
Id Fmt Data Metadt Rel_Perf
|
||||
0 + 512 0 0
|
||||
|
||||
=== START OF SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
SMART/Health Information (NVMe Log 0x02)
|
||||
Critical Warning: 0x00
|
||||
Temperature: 49 Celsius
|
||||
Available Spare: 100%
|
||||
Available Spare Threshold: 32%
|
||||
Percentage Used: 0%
|
||||
Data Units Read: 255,524 [130 GB]
|
||||
Data Units Written: 1,418,257 [726 GB]
|
||||
Host Read Commands: 3,816,095
|
||||
Host Write Commands: 15,571,024
|
||||
Controller Busy Time: 0
|
||||
Power Cycles: 47
|
||||
Power On Hours: 387
|
||||
Unsafe Shutdowns: 23
|
||||
Media and Data Integrity Errors: 0
|
||||
Error Information Log Entries: 0
|
||||
Warning Comp. Temperature Time: 0
|
||||
Critical Comp. Temperature Time: 0
|
||||
|
||||
Error Information (NVMe Log 0x01, 8 of 8 entries)
|
||||
No Errors Logged
|
||||
|
||||
Self-test Log (NVMe Log 0x06)
|
||||
Self-test status: No self-test in progress
|
||||
No Self-tests Logged
|
||||
|
64
NVMe/Team/TM8/TM8FP6256G/1670CA9C51E8
Normal file
64
NVMe/Team/TM8/TM8FP6256G/1670CA9C51E8
Normal file
@@ -0,0 +1,64 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p9 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Number: TEAM TM8FP6256G
|
||||
Serial Number: --
|
||||
Firmware Version: V0808A0
|
||||
PCI Vendor/Subsystem ID: 0x126f
|
||||
IEEE OUI Identifier: 0x000000
|
||||
Controller ID: 1
|
||||
NVMe Version: 1.3
|
||||
Number of Namespaces: 1
|
||||
Namespace 1 Size/Capacity: 256,060,514,304 [256 GB]
|
||||
Namespace 1 Formatted LBA Size: 512
|
||||
Local Time is: Fri Feb 9 19:33:27 2024 EST
|
||||
Firmware Updates (0x12): 1 Slot, no Reset required
|
||||
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
|
||||
Optional NVM Commands (0x0015): Comp DS_Mngmt Sav/Sel_Feat
|
||||
Log Page Attributes (0x03): S/H_per_NS Cmd_Eff_Lg
|
||||
Maximum Data Transfer Size: 64 Pages
|
||||
Warning Comp. Temp. Threshold: 83 Celsius
|
||||
Critical Comp. Temp. Threshold: 85 Celsius
|
||||
|
||||
Supported Power States
|
||||
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
|
||||
0 + 6.00W - - 0 0 0 0 15000 0
|
||||
1 + 3.00W - - 1 1 1 1 15000 0
|
||||
2 + 1.50W - - 2 2 2 2 15000 0
|
||||
3 - 0.0450W - - 3 3 3 3 15000 15000
|
||||
4 - 0.0040W - - 4 4 4 4 25000 25000
|
||||
|
||||
Supported LBA Sizes (NSID 0x1)
|
||||
Id Fmt Data Metadt Rel_Perf
|
||||
0 + 512 0 0
|
||||
|
||||
=== START OF SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
SMART/Health Information (NVMe Log 0x02)
|
||||
Critical Warning: 0x00
|
||||
Temperature: 79 Celsius
|
||||
Available Spare: 100%
|
||||
Available Spare Threshold: 10%
|
||||
Percentage Used: 0%
|
||||
Data Units Read: 29,672 [15.1 GB]
|
||||
Data Units Written: 1,039,759 [532 GB]
|
||||
Host Read Commands: 1,302,658
|
||||
Host Write Commands: 14,181,231
|
||||
Controller Busy Time: 217
|
||||
Power Cycles: 18
|
||||
Power On Hours: 84
|
||||
Unsafe Shutdowns: 12
|
||||
Media and Data Integrity Errors: 0
|
||||
Error Information Log Entries: 0
|
||||
Warning Comp. Temperature Time: 1
|
||||
Critical Comp. Temperature Time: 0
|
||||
|
||||
Error Information (NVMe Log 0x01, 16 of 64 entries)
|
||||
No Errors Logged
|
||||
|
||||
Self-test Log (NVMe Log 0x06)
|
||||
Self-test status: No self-test in progress
|
||||
No Self-tests Logged
|
||||
|
65
NVMe/Team/TM8/TM8FP6256G/1C01EC280736
Normal file
65
NVMe/Team/TM8/TM8FP6256G/1C01EC280736
Normal file
@@ -0,0 +1,65 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p11 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Number: TEAM TM8FP6256G
|
||||
Serial Number: --
|
||||
Firmware Version: VC2S038E
|
||||
PCI Vendor/Subsystem ID: 0x10ec
|
||||
IEEE OUI Identifier: 0x00e04c
|
||||
Controller ID: 1
|
||||
NVMe Version: 1.4
|
||||
Number of Namespaces: 1
|
||||
Namespace 1 Size/Capacity: 256,060,514,304 [256 GB]
|
||||
Namespace 1 Formatted LBA Size: 512
|
||||
Namespace 1 IEEE EUI-64: 00e04c ...
|
||||
Local Time is: Mon Jun 24 20:44:24 2024 UTC
|
||||
Firmware Updates (0x02): 1 Slot
|
||||
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
|
||||
Optional NVM Commands (0x005e): Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
|
||||
Log Page Attributes (0x02): Cmd_Eff_Lg
|
||||
Maximum Data Transfer Size: 32 Pages
|
||||
Warning Comp. Temp. Threshold: 100 Celsius
|
||||
Critical Comp. Temp. Threshold: 110 Celsius
|
||||
|
||||
Supported Power States
|
||||
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
|
||||
0 + 8.00W - - 0 0 0 0 230000 50000
|
||||
1 + 4.00W - - 1 1 1 1 4000 50000
|
||||
2 + 3.00W - - 2 2 2 2 4000 250000
|
||||
3 - 0.0300W - - 3 3 3 3 5000 10000
|
||||
4 - 0.0050W - - 4 4 4 4 54000 45000
|
||||
|
||||
Supported LBA Sizes (NSID 0x1)
|
||||
Id Fmt Data Metadt Rel_Perf
|
||||
0 + 512 0 0
|
||||
|
||||
=== START OF SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
SMART/Health Information (NVMe Log 0x02)
|
||||
Critical Warning: 0x00
|
||||
Temperature: 46 Celsius
|
||||
Available Spare: 100%
|
||||
Available Spare Threshold: 32%
|
||||
Percentage Used: 0%
|
||||
Data Units Read: 309,046 [158 GB]
|
||||
Data Units Written: 426,286 [218 GB]
|
||||
Host Read Commands: 1,377,379
|
||||
Host Write Commands: 4,184,816
|
||||
Controller Busy Time: 0
|
||||
Power Cycles: 11
|
||||
Power On Hours: 747
|
||||
Unsafe Shutdowns: 7
|
||||
Media and Data Integrity Errors: 0
|
||||
Error Information Log Entries: 0
|
||||
Warning Comp. Temperature Time: 0
|
||||
Critical Comp. Temperature Time: 0
|
||||
|
||||
Error Information (NVMe Log 0x01, 8 of 8 entries)
|
||||
No Errors Logged
|
||||
|
||||
Self-test Log (NVMe Log 0x06)
|
||||
Self-test status: No self-test in progress
|
||||
No Self-tests Logged
|
||||
|
59
NVMe/Team/TM8/TM8FP6256G/3F86E4D8774A
Normal file
59
NVMe/Team/TM8/TM8FP6256G/3F86E4D8774A
Normal file
@@ -0,0 +1,59 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Number: TEAM TM8FP6256G
|
||||
Serial Number: --
|
||||
Firmware Version: V1.6.C2
|
||||
PCI Vendor/Subsystem ID: 0x1d97
|
||||
IEEE OUI Identifier: 0x3a5a27
|
||||
Total NVM Capacity: 256,060,514,304 [256 GB]
|
||||
Unallocated NVM Capacity: 0
|
||||
Controller ID: 0
|
||||
NVMe Version: 1.4
|
||||
Number of Namespaces: 1
|
||||
Namespace 1 Size/Capacity: 256,060,514,304 [256 GB]
|
||||
Namespace 1 Formatted LBA Size: 512
|
||||
Namespace 1 IEEE EUI-64: 3a5a27 ...
|
||||
Local Time is: Wed Jun 28 21:30:44 2023 UTC
|
||||
Firmware Updates (0x02): 1 Slot
|
||||
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
|
||||
Optional NVM Commands (0x004c): DS_Mngmt Wr_Zero Timestmp
|
||||
Log Page Attributes (0x0a): Cmd_Eff_Lg Telmtry_Lg
|
||||
Maximum Data Transfer Size: 32 Pages
|
||||
Warning Comp. Temp. Threshold: 81 Celsius
|
||||
Critical Comp. Temp. Threshold: 85 Celsius
|
||||
|
||||
Supported Power States
|
||||
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
|
||||
0 + 5.00W - - 0 0 0 0 5 700
|
||||
|
||||
Supported LBA Sizes (NSID 0x1)
|
||||
Id Fmt Data Metadt Rel_Perf
|
||||
0 + 512 0 3
|
||||
|
||||
=== START OF SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
SMART/Health Information (NVMe Log 0x02)
|
||||
Critical Warning: 0x00
|
||||
Temperature: 44 Celsius
|
||||
Available Spare: 100%
|
||||
Available Spare Threshold: 10%
|
||||
Percentage Used: 1%
|
||||
Data Units Read: 2,953,259 [1.51 TB]
|
||||
Data Units Written: 967,125 [495 GB]
|
||||
Host Read Commands: 24,299,326
|
||||
Host Write Commands: 4,379,530
|
||||
Controller Busy Time: 186
|
||||
Power Cycles: 302
|
||||
Power On Hours: 2,114
|
||||
Unsafe Shutdowns: 28
|
||||
Media and Data Integrity Errors: 0
|
||||
Error Information Log Entries: 0
|
||||
Warning Comp. Temperature Time: 0
|
||||
Critical Comp. Temperature Time: 0
|
||||
|
||||
Error Information (NVMe Log 0x01, 16 of 64 entries)
|
||||
No Errors Logged
|
||||
|
69
NVMe/Team/TM8/TM8FP6256G/5F446DF1DBB4
Normal file
69
NVMe/Team/TM8/TM8FP6256G/5F446DF1DBB4
Normal file
@@ -0,0 +1,69 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p11 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Number: TEAM TM8FP6256G
|
||||
Serial Number: --
|
||||
Firmware Version: EDFM90.0
|
||||
PCI Vendor/Subsystem ID: 0x1987
|
||||
IEEE OUI Identifier: 0x6479a7
|
||||
Total NVM Capacity: 256,060,514,304 [256 GB]
|
||||
Unallocated NVM Capacity: 0
|
||||
Controller ID: 1
|
||||
NVMe Version: 1.3
|
||||
Number of Namespaces: 1
|
||||
Namespace 1 Size/Capacity: 256,060,514,304 [256 GB]
|
||||
Namespace 1 Formatted LBA Size: 512
|
||||
Namespace 1 IEEE EUI-64: 6479a7 ...
|
||||
Local Time is: Sun Apr 28 09:58:12 2024 CDT
|
||||
Firmware Updates (0x12): 1 Slot, no Reset required
|
||||
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
|
||||
Optional NVM Commands (0x005e): Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
|
||||
Log Page Attributes (0x0a): Cmd_Eff_Lg Telmtry_Lg
|
||||
Maximum Data Transfer Size: 64 Pages
|
||||
Warning Comp. Temp. Threshold: 70 Celsius
|
||||
Critical Comp. Temp. Threshold: 80 Celsius
|
||||
|
||||
Supported Power States
|
||||
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
|
||||
0 + 3.50W - - 0 0 0 0 0 0
|
||||
1 + 1.90W - - 1 1 1 1 0 0
|
||||
2 + 1.50W - - 2 2 2 2 0 0
|
||||
3 - 0.0700W - - 3 3 3 3 5000 1900
|
||||
4 - 0.0020W - - 4 4 4 4 13000 100000
|
||||
|
||||
Supported LBA Sizes (NSID 0x1)
|
||||
Id Fmt Data Metadt Rel_Perf
|
||||
0 + 512 0 1
|
||||
1 - 4096 0 0
|
||||
|
||||
=== START OF SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
SMART/Health Information (NVMe Log 0x02)
|
||||
Critical Warning: 0x00
|
||||
Temperature: 55 Celsius
|
||||
Available Spare: 100%
|
||||
Available Spare Threshold: 5%
|
||||
Percentage Used: 4%
|
||||
Data Units Read: 633,983 [324 GB]
|
||||
Data Units Written: 9,204,321 [4.71 TB]
|
||||
Host Read Commands: 27,955,812
|
||||
Host Write Commands: 72,707,839
|
||||
Controller Busy Time: 291
|
||||
Power Cycles: 69
|
||||
Power On Hours: 3,682
|
||||
Unsafe Shutdowns: 40
|
||||
Media and Data Integrity Errors: 0
|
||||
Error Information Log Entries: 409,202
|
||||
Warning Comp. Temperature Time: 0
|
||||
Critical Comp. Temperature Time: 0
|
||||
Temperature Sensor 1: 72 Celsius
|
||||
|
||||
Error Information (NVMe Log 0x01, 16 of 16 entries)
|
||||
No Errors Logged
|
||||
|
||||
Self-test Log (NVMe Log 0x06)
|
||||
Self-test status: No self-test in progress
|
||||
No Self-tests Logged
|
||||
|
65
NVMe/Team/TM8/TM8FP6256G/71F3071D3806
Normal file
65
NVMe/Team/TM8/TM8FP6256G/71F3071D3806
Normal file
@@ -0,0 +1,65 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p3 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Number: TEAM TM8FP6256G
|
||||
Serial Number: --
|
||||
Firmware Version: VC2S038E
|
||||
PCI Vendor/Subsystem ID: 0x10ec
|
||||
IEEE OUI Identifier: 0x00e04c
|
||||
Controller ID: 1
|
||||
NVMe Version: 1.4
|
||||
Number of Namespaces: 1
|
||||
Namespace 1 Size/Capacity: 256,060,514,304 [256 GB]
|
||||
Namespace 1 Formatted LBA Size: 512
|
||||
Namespace 1 IEEE EUI-64: 00e04c ...
|
||||
Local Time is: Thu Sep 28 21:45:54 2023 PDT
|
||||
Firmware Updates (0x02): 1 Slot
|
||||
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
|
||||
Optional NVM Commands (0x005e): Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
|
||||
Log Page Attributes (0x02): Cmd_Eff_Lg
|
||||
Maximum Data Transfer Size: 32 Pages
|
||||
Warning Comp. Temp. Threshold: 100 Celsius
|
||||
Critical Comp. Temp. Threshold: 110 Celsius
|
||||
|
||||
Supported Power States
|
||||
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
|
||||
0 + 8.00W - - 0 0 0 0 230000 50000
|
||||
1 + 4.00W - - 1 1 1 1 4000 50000
|
||||
2 + 3.00W - - 2 2 2 2 4000 250000
|
||||
3 - 0.0300W - - 3 3 3 3 5000 10000
|
||||
4 - 0.0050W - - 4 4 4 4 54000 45000
|
||||
|
||||
Supported LBA Sizes (NSID 0x1)
|
||||
Id Fmt Data Metadt Rel_Perf
|
||||
0 + 512 0 0
|
||||
|
||||
=== START OF SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
SMART/Health Information (NVMe Log 0x02)
|
||||
Critical Warning: 0x00
|
||||
Temperature: 54 Celsius
|
||||
Available Spare: 100%
|
||||
Available Spare Threshold: 32%
|
||||
Percentage Used: 0%
|
||||
Data Units Read: 1,510 [773 MB]
|
||||
Data Units Written: 11,834 [6.05 GB]
|
||||
Host Read Commands: 40,847
|
||||
Host Write Commands: 289,405
|
||||
Controller Busy Time: 0
|
||||
Power Cycles: 6
|
||||
Power On Hours: 5
|
||||
Unsafe Shutdowns: 4
|
||||
Media and Data Integrity Errors: 0
|
||||
Error Information Log Entries: 0
|
||||
Warning Comp. Temperature Time: 0
|
||||
Critical Comp. Temperature Time: 0
|
||||
|
||||
Error Information (NVMe Log 0x01, 8 of 8 entries)
|
||||
No Errors Logged
|
||||
|
||||
Self-test Log (NVMe Log 0x06)
|
||||
Self-test status: No self-test in progress
|
||||
No Self-tests Logged
|
||||
|
69
NVMe/Team/TM8/TM8FP6256G/B54A1B5814D6
Normal file
69
NVMe/Team/TM8/TM8FP6256G/B54A1B5814D6
Normal file
@@ -0,0 +1,69 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p11 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Number: TEAM TM8FP6256G
|
||||
Serial Number: --
|
||||
Firmware Version: SN10660
|
||||
PCI Vendor/Subsystem ID: 0x1e4b
|
||||
IEEE OUI Identifier: 0x3a5a27
|
||||
Total NVM Capacity: 256,060,514,304 [256 GB]
|
||||
Unallocated NVM Capacity: 0
|
||||
Controller ID: 0
|
||||
NVMe Version: 1.4
|
||||
Number of Namespaces: 1
|
||||
Namespace 1 Size/Capacity: 256,060,514,304 [256 GB]
|
||||
Namespace 1 Formatted LBA Size: 512
|
||||
Namespace 1 IEEE EUI-64: 3a5a27 ...
|
||||
Local Time is: Fri May 17 21:41:17 2024 PDT
|
||||
Firmware Updates (0x1a): 5 Slots, no Reset required
|
||||
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
|
||||
Optional NVM Commands (0x001f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat
|
||||
Log Page Attributes (0x06): Cmd_Eff_Lg Ext_Get_Lg
|
||||
Maximum Data Transfer Size: 128 Pages
|
||||
Warning Comp. Temp. Threshold: 90 Celsius
|
||||
Critical Comp. Temp. Threshold: 95 Celsius
|
||||
|
||||
Supported Power States
|
||||
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
|
||||
0 + 6.50W - - 0 0 0 0 0 0
|
||||
1 + 5.80W - - 1 1 1 1 0 0
|
||||
2 + 3.60W - - 2 2 2 2 0 0
|
||||
3 - 0.0500W - - 3 3 3 3 5000 10000
|
||||
4 - 0.0025W - - 4 4 4 4 8000 45000
|
||||
|
||||
Supported LBA Sizes (NSID 0x1)
|
||||
Id Fmt Data Metadt Rel_Perf
|
||||
0 + 512 0 0
|
||||
|
||||
=== START OF SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
SMART/Health Information (NVMe Log 0x02)
|
||||
Critical Warning: 0x00
|
||||
Temperature: 48 Celsius
|
||||
Available Spare: 100%
|
||||
Available Spare Threshold: 10%
|
||||
Percentage Used: 0%
|
||||
Data Units Read: 12,134 [6.21 GB]
|
||||
Data Units Written: 21,319 [10.9 GB]
|
||||
Host Read Commands: 282,880
|
||||
Host Write Commands: 283,213
|
||||
Controller Busy Time: 0
|
||||
Power Cycles: 31
|
||||
Power On Hours: 16
|
||||
Unsafe Shutdowns: 24
|
||||
Media and Data Integrity Errors: 0
|
||||
Error Information Log Entries: 0
|
||||
Warning Comp. Temperature Time: 0
|
||||
Critical Comp. Temperature Time: 0
|
||||
Temperature Sensor 1: 48 Celsius
|
||||
Temperature Sensor 2: 52 Celsius
|
||||
|
||||
Error Information (NVMe Log 0x01, 16 of 64 entries)
|
||||
No Errors Logged
|
||||
|
||||
Self-test Log (NVMe Log 0x06)
|
||||
Self-test status: No self-test in progress
|
||||
No Self-tests Logged
|
||||
|
62
NVMe/Team/TM8/TM8FP6256G/C07AA677BDED
Normal file
62
NVMe/Team/TM8/TM8FP6256G/C07AA677BDED
Normal file
@@ -0,0 +1,62 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p11 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Number: TEAM TM8FP6256G
|
||||
Serial Number: --
|
||||
Firmware Version: U0521A3
|
||||
PCI Vendor/Subsystem ID: 0x126f
|
||||
IEEE OUI Identifier: 0x000000
|
||||
Controller ID: 1
|
||||
NVMe Version: 1.3
|
||||
Number of Namespaces: 1
|
||||
Namespace 1 Size/Capacity: 256,060,514,304 [256 GB]
|
||||
Namespace 1 Formatted LBA Size: 512
|
||||
Local Time is: Sat Jul 20 23:24:16 2024 PDT
|
||||
Firmware Updates (0x12): 1 Slot, no Reset required
|
||||
Optional Admin Commands (0x0007): Security Format Frmw_DL
|
||||
Optional NVM Commands (0x0015): Comp DS_Mngmt Sav/Sel_Feat
|
||||
Log Page Attributes (0x03): S/H_per_NS Cmd_Eff_Lg
|
||||
Maximum Data Transfer Size: 64 Pages
|
||||
Warning Comp. Temp. Threshold: 83 Celsius
|
||||
Critical Comp. Temp. Threshold: 85 Celsius
|
||||
|
||||
Supported Power States
|
||||
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
|
||||
0 + 6.00W - - 0 0 0 0 0 0
|
||||
1 + 3.00W - - 1 1 1 1 0 0
|
||||
2 + 1.50W - - 2 2 2 2 0 0
|
||||
3 - 0.0450W - - 3 3 3 3 3000 3000
|
||||
4 - 0.0040W - - 4 4 4 4 25000 25000
|
||||
|
||||
Supported LBA Sizes (NSID 0x1)
|
||||
Id Fmt Data Metadt Rel_Perf
|
||||
0 + 512 0 0
|
||||
|
||||
=== START OF SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
SMART/Health Information (NVMe Log 0x02)
|
||||
Critical Warning: 0x00
|
||||
Temperature: 45 Celsius
|
||||
Available Spare: 100%
|
||||
Available Spare Threshold: 10%
|
||||
Percentage Used: 10%
|
||||
Data Units Read: 191,879 [98.2 GB]
|
||||
Data Units Written: 51,431,146 [26.3 TB]
|
||||
Host Read Commands: 4,634,410
|
||||
Host Write Commands: 1,153,563,347
|
||||
Controller Busy Time: 1,674
|
||||
Power Cycles: 14
|
||||
Power On Hours: 9,753
|
||||
Unsafe Shutdowns: 10
|
||||
Media and Data Integrity Errors: 0
|
||||
Error Information Log Entries: 0
|
||||
Warning Comp. Temperature Time: 0
|
||||
Critical Comp. Temperature Time: 0
|
||||
|
||||
Error Information (NVMe Log 0x01, 16 of 64 entries)
|
||||
No Errors Logged
|
||||
|
||||
Self-tests not supported
|
||||
|
72
NVMe/Team/TM8/TM8FP6256G/DE2A983C3354
Normal file
72
NVMe/Team/TM8/TM8FP6256G/DE2A983C3354
Normal file
@@ -0,0 +1,72 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p2 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Number: TEAM TM8FP6256G
|
||||
Serial Number: --
|
||||
Firmware Version: EDFM90.0
|
||||
PCI Vendor/Subsystem ID: 0x1987
|
||||
IEEE OUI Identifier: 0x6479a7
|
||||
Total NVM Capacity: 256,060,514,304 [256 GB]
|
||||
Unallocated NVM Capacity: 0
|
||||
Controller ID: 1
|
||||
NVMe Version: 1.3
|
||||
Number of Namespaces: 1
|
||||
Namespace 1 Size/Capacity: 256,060,514,304 [256 GB]
|
||||
Namespace 1 Formatted LBA Size: 512
|
||||
Namespace 1 IEEE EUI-64: 6479a7 ...
|
||||
Local Time is: Tue Aug 15 08:46:12 2023 EDT
|
||||
Firmware Updates (0x12): 1 Slot, no Reset required
|
||||
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
|
||||
Optional NVM Commands (0x005e): Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
|
||||
Log Page Attributes (0x0a): Cmd_Eff_Lg Telmtry_Lg
|
||||
Maximum Data Transfer Size: 64 Pages
|
||||
Warning Comp. Temp. Threshold: 70 Celsius
|
||||
Critical Comp. Temp. Threshold: 80 Celsius
|
||||
|
||||
Supported Power States
|
||||
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
|
||||
0 + 3.50W - - 0 0 0 0 0 0
|
||||
1 + 1.90W - - 1 1 1 1 0 0
|
||||
2 + 1.50W - - 2 2 2 2 0 0
|
||||
3 - 0.0700W - - 3 3 3 3 5000 1900
|
||||
4 - 0.0020W - - 4 4 4 4 13000 100000
|
||||
|
||||
Supported LBA Sizes (NSID 0x1)
|
||||
Id Fmt Data Metadt Rel_Perf
|
||||
0 + 512 0 1
|
||||
1 - 4096 0 0
|
||||
|
||||
=== START OF SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
SMART/Health Information (NVMe Log 0x02)
|
||||
Critical Warning: 0x00
|
||||
Temperature: 61 Celsius
|
||||
Available Spare: 100%
|
||||
Available Spare Threshold: 5%
|
||||
Percentage Used: 0%
|
||||
Data Units Read: 24,430 [12.5 GB]
|
||||
Data Units Written: 386,029 [197 GB]
|
||||
Host Read Commands: 748,076
|
||||
Host Write Commands: 11,766,142
|
||||
Controller Busy Time: 13
|
||||
Power Cycles: 18
|
||||
Power On Hours: 562
|
||||
Unsafe Shutdowns: 13
|
||||
Media and Data Integrity Errors: 0
|
||||
Error Information Log Entries: 2
|
||||
Warning Comp. Temperature Time: 6
|
||||
Critical Comp. Temperature Time: 0
|
||||
Temperature Sensor 1: 79 Celsius
|
||||
Thermal Temp. 1 Transition Count: 4
|
||||
Thermal Temp. 1 Total Time: 73244
|
||||
|
||||
Error Information (NVMe Log 0x01, 16 of 16 entries)
|
||||
No Errors Logged
|
||||
|
||||
Self-test Log (NVMe Log 0x06)
|
||||
Self-test status: No self-test in progress
|
||||
Num Test_Description Status Power_on_Hours Failing_LBA NSID Seg SCT Code
|
||||
0 Short Completed without error 436 - - - - -
|
||||
|
69
NVMe/Team/TM8/TM8FP6256G/E81AC2981871
Normal file
69
NVMe/Team/TM8/TM8FP6256G/E81AC2981871
Normal file
@@ -0,0 +1,69 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p11 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Number: TEAM TM8FP6256G
|
||||
Serial Number: --
|
||||
Firmware Version: APF1M3R1
|
||||
PCI Vendor/Subsystem ID: 0x1ed0
|
||||
IEEE OUI Identifier: 0x2c3ebf
|
||||
Total NVM Capacity: 256,060,514,304 [256 GB]
|
||||
Unallocated NVM Capacity: 0
|
||||
Controller ID: 1
|
||||
NVMe Version: 1.3
|
||||
Number of Namespaces: 1
|
||||
Namespace 1 Size/Capacity: 256,060,514,304 [256 GB]
|
||||
Namespace 1 Formatted LBA Size: 512
|
||||
Namespace 1 IEEE EUI-64: 2c3ebf ...
|
||||
Local Time is: Fri Jul 26 19:51:17 2024 CDT
|
||||
Firmware Updates (0x12): 1 Slot, no Reset required
|
||||
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
|
||||
Optional NVM Commands (0x0056): Wr_Unc DS_Mngmt Sav/Sel_Feat Timestmp
|
||||
Log Page Attributes (0x0a): Cmd_Eff_Lg Telmtry_Lg
|
||||
Maximum Data Transfer Size: 64 Pages
|
||||
Warning Comp. Temp. Threshold: 80 Celsius
|
||||
Critical Comp. Temp. Threshold: 85 Celsius
|
||||
|
||||
Supported Power States
|
||||
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
|
||||
0 + 3.50W - - 0 0 0 0 0 0
|
||||
1 + 1.90W - - 1 1 1 1 0 0
|
||||
2 + 1.50W - - 2 2 2 2 0 0
|
||||
3 - 0.0700W - - 3 3 3 3 1000 1000
|
||||
4 - 0.0050W - - 4 4 4 4 5000 45000
|
||||
|
||||
Supported LBA Sizes (NSID 0x1)
|
||||
Id Fmt Data Metadt Rel_Perf
|
||||
0 + 512 0 1
|
||||
1 - 4096 0 0
|
||||
|
||||
=== START OF SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
SMART/Health Information (NVMe Log 0x02)
|
||||
Critical Warning: 0x00
|
||||
Temperature: 38 Celsius
|
||||
Available Spare: 100%
|
||||
Available Spare Threshold: 5%
|
||||
Percentage Used: 0%
|
||||
Data Units Read: 39,973 [20.4 GB]
|
||||
Data Units Written: 41,132 [21.0 GB]
|
||||
Host Read Commands: 644,901
|
||||
Host Write Commands: 493,463
|
||||
Controller Busy Time: 2
|
||||
Power Cycles: 84
|
||||
Power On Hours: 22
|
||||
Unsafe Shutdowns: 32
|
||||
Media and Data Integrity Errors: 0
|
||||
Error Information Log Entries: 0
|
||||
Warning Comp. Temperature Time: 0
|
||||
Critical Comp. Temperature Time: 0
|
||||
Temperature Sensor 1: 57 Celsius
|
||||
|
||||
Error Information (NVMe Log 0x01, 16 of 16 entries)
|
||||
No Errors Logged
|
||||
|
||||
Self-test Log (NVMe Log 0x06)
|
||||
Self-test status: No self-test in progress
|
||||
No Self-tests Logged
|
||||
|
74
NVMe/Team/TM8/TM8FP6256G/EA39069FC2E4
Normal file
74
NVMe/Team/TM8/TM8FP6256G/EA39069FC2E4
Normal file
@@ -0,0 +1,74 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p7 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Number: TEAM TM8FP6256G
|
||||
Serial Number: --
|
||||
Firmware Version: EDFM90.1
|
||||
PCI Vendor/Subsystem ID: 0x1987
|
||||
IEEE OUI Identifier: 0x6479a7
|
||||
Total NVM Capacity: 256,060,514,304 [256 GB]
|
||||
Unallocated NVM Capacity: 0
|
||||
Controller ID: 1
|
||||
NVMe Version: 1.3
|
||||
Number of Namespaces: 1
|
||||
Namespace 1 Size/Capacity: 256,060,514,304 [256 GB]
|
||||
Namespace 1 Formatted LBA Size: 512
|
||||
Namespace 1 IEEE EUI-64: 6479a7 ...
|
||||
Local Time is: Sat Dec 16 20:45:23 2023 EST
|
||||
Firmware Updates (0x12): 1 Slot, no Reset required
|
||||
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
|
||||
Optional NVM Commands (0x005e): Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
|
||||
Log Page Attributes (0x0a): Cmd_Eff_Lg Telmtry_Lg
|
||||
Maximum Data Transfer Size: 64 Pages
|
||||
Warning Comp. Temp. Threshold: 70 Celsius
|
||||
Critical Comp. Temp. Threshold: 80 Celsius
|
||||
|
||||
Supported Power States
|
||||
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
|
||||
0 + 4.50W - - 0 0 0 0 0 0
|
||||
1 + 2.70W - - 1 1 1 1 0 0
|
||||
2 + 2.16W - - 2 2 2 2 0 0
|
||||
3 - 0.0700W - - 3 3 3 3 5000 1900
|
||||
4 - 0.0050W - - 4 4 4 4 13000 100000
|
||||
|
||||
Supported LBA Sizes (NSID 0x1)
|
||||
Id Fmt Data Metadt Rel_Perf
|
||||
0 + 512 0 1
|
||||
1 - 4096 0 0
|
||||
|
||||
=== START OF SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
SMART/Health Information (NVMe Log 0x02)
|
||||
Critical Warning: 0x00
|
||||
Temperature: 63 Celsius
|
||||
Available Spare: 100%
|
||||
Available Spare Threshold: 5%
|
||||
Percentage Used: 8%
|
||||
Data Units Read: 969,998 [496 GB]
|
||||
Data Units Written: 17,928,038 [9.17 TB]
|
||||
Host Read Commands: 29,797,551
|
||||
Host Write Commands: 632,292,051
|
||||
Controller Busy Time: 1,086
|
||||
Power Cycles: 24
|
||||
Power On Hours: 8,226
|
||||
Unsafe Shutdowns: 19
|
||||
Media and Data Integrity Errors: 0
|
||||
Error Information Log Entries: 0
|
||||
Warning Comp. Temperature Time: 3
|
||||
Critical Comp. Temperature Time: 0
|
||||
Temperature Sensor 1: 81 Celsius
|
||||
Thermal Temp. 1 Transition Count: 19
|
||||
Thermal Temp. 2 Transition Count: 2
|
||||
Thermal Temp. 1 Total Time: 2841
|
||||
Thermal Temp. 2 Total Time: 568
|
||||
|
||||
Error Information (NVMe Log 0x01, 16 of 16 entries)
|
||||
No Errors Logged
|
||||
|
||||
Self-test Log (NVMe Log 0x06)
|
||||
Self-test status: No self-test in progress
|
||||
Num Test_Description Status Power_on_Hours Failing_LBA NSID Seg SCT Code
|
||||
0 Short Completed without error 0 - - - - -
|
||||
|
71
NVMe/Team/TM8/TM8FP6512G/217945D9E7B4
Normal file
71
NVMe/Team/TM8/TM8FP6512G/217945D9E7B4
Normal file
@@ -0,0 +1,71 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p10 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Number: TEAM TM8FP6512G
|
||||
Serial Number: --
|
||||
Firmware Version: EDFMG1.5
|
||||
PCI Vendor/Subsystem ID: 0x1987
|
||||
IEEE OUI Identifier: 0x6479a7
|
||||
Total NVM Capacity: 512,110,190,592 [512 GB]
|
||||
Unallocated NVM Capacity: 0
|
||||
Controller ID: 1
|
||||
NVMe Version: 1.3
|
||||
Number of Namespaces: 1
|
||||
Namespace 1 Size/Capacity: 512,110,190,592 [512 GB]
|
||||
Namespace 1 Formatted LBA Size: 512
|
||||
Namespace 1 IEEE EUI-64: 6479a7 ...
|
||||
Local Time is: Wed Mar 13 18:58:24 2024 EDT
|
||||
Firmware Updates (0x12): 1 Slot, no Reset required
|
||||
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
|
||||
Optional NVM Commands (0x0056): Wr_Unc DS_Mngmt Sav/Sel_Feat Timestmp
|
||||
Log Page Attributes (0x0a): Cmd_Eff_Lg Telmtry_Lg
|
||||
Maximum Data Transfer Size: 64 Pages
|
||||
Warning Comp. Temp. Threshold: 85 Celsius
|
||||
Critical Comp. Temp. Threshold: 95 Celsius
|
||||
|
||||
Supported Power States
|
||||
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
|
||||
0 + 4.50W - - 0 0 0 0 0 0
|
||||
1 + 2.70W - - 1 1 1 1 0 0
|
||||
2 + 2.16W - - 2 2 2 2 0 0
|
||||
3 - 0.0700W - - 3 3 3 3 1000 1000
|
||||
4 - 0.0050W - - 4 4 4 4 5000 50000
|
||||
|
||||
Supported LBA Sizes (NSID 0x1)
|
||||
Id Fmt Data Metadt Rel_Perf
|
||||
0 + 512 0 1
|
||||
1 - 4096 0 0
|
||||
|
||||
=== START OF SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
SMART/Health Information (NVMe Log 0x02)
|
||||
Critical Warning: 0x00
|
||||
Temperature: 43 Celsius
|
||||
Available Spare: 100%
|
||||
Available Spare Threshold: 5%
|
||||
Percentage Used: 1%
|
||||
Data Units Read: 3,831,601 [1.96 TB]
|
||||
Data Units Written: 15,823,801 [8.10 TB]
|
||||
Host Read Commands: 34,979,589
|
||||
Host Write Commands: 316,018,157
|
||||
Controller Busy Time: 1,324
|
||||
Power Cycles: 24
|
||||
Power On Hours: 5,746
|
||||
Unsafe Shutdowns: 9
|
||||
Media and Data Integrity Errors: 0
|
||||
Error Information Log Entries: 0
|
||||
Warning Comp. Temperature Time: 0
|
||||
Critical Comp. Temperature Time: 0
|
||||
Temperature Sensor 1: 59 Celsius
|
||||
|
||||
Error Information (NVMe Log 0x01, 16 of 16 entries)
|
||||
No Errors Logged
|
||||
|
||||
Self-test Log (NVMe Log 0x06)
|
||||
Self-test status: No self-test in progress
|
||||
Num Test_Description Status Power_on_Hours Failing_LBA NSID Seg SCT Code
|
||||
0 Extended Completed without error 5176 - - - - -
|
||||
1 Short Completed without error 5121 - - - - -
|
||||
|
69
NVMe/Team/TM8/TM8FP6512G/5077D71FCCA2
Normal file
69
NVMe/Team/TM8/TM8FP6512G/5077D71FCCA2
Normal file
@@ -0,0 +1,69 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p11 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Number: TEAM TM8FP6512G
|
||||
Serial Number: --
|
||||
Firmware Version: EDFOE0.3
|
||||
PCI Vendor/Subsystem ID: 0x1987
|
||||
IEEE OUI Identifier: 0x6479a7
|
||||
Total NVM Capacity: 512,110,190,592 [512 GB]
|
||||
Unallocated NVM Capacity: 0
|
||||
Controller ID: 1
|
||||
NVMe Version: 1.3
|
||||
Number of Namespaces: 1
|
||||
Namespace 1 Size/Capacity: 512,110,190,592 [512 GB]
|
||||
Namespace 1 Formatted LBA Size: 512
|
||||
Namespace 1 IEEE EUI-64: 6479a7 ...
|
||||
Local Time is: Wed Jul 24 08:29:07 2024 CDT
|
||||
Firmware Updates (0x12): 1 Slot, no Reset required
|
||||
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
|
||||
Optional NVM Commands (0x005e): Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
|
||||
Log Page Attributes (0x0a): Cmd_Eff_Lg Telmtry_Lg
|
||||
Maximum Data Transfer Size: 64 Pages
|
||||
Warning Comp. Temp. Threshold: 85 Celsius
|
||||
Critical Comp. Temp. Threshold: 90 Celsius
|
||||
|
||||
Supported Power States
|
||||
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
|
||||
0 + 4.50W - - 0 0 0 0 0 0
|
||||
1 + 2.70W - - 1 1 1 1 0 0
|
||||
2 + 2.16W - - 2 2 2 2 0 0
|
||||
3 - 0.0700W - - 3 3 3 3 1000 1000
|
||||
4 - 0.0050W - - 4 4 4 4 5000 50000
|
||||
|
||||
Supported LBA Sizes (NSID 0x1)
|
||||
Id Fmt Data Metadt Rel_Perf
|
||||
0 + 512 0 1
|
||||
1 - 4096 0 0
|
||||
|
||||
=== START OF SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
SMART/Health Information (NVMe Log 0x02)
|
||||
Critical Warning: 0x00
|
||||
Temperature: 45 Celsius
|
||||
Available Spare: 100%
|
||||
Available Spare Threshold: 5%
|
||||
Percentage Used: 2%
|
||||
Data Units Read: 88,503 [45.3 GB]
|
||||
Data Units Written: 11,954,434 [6.12 TB]
|
||||
Host Read Commands: 2,968,098
|
||||
Host Write Commands: 174,447,247
|
||||
Controller Busy Time: 3,244
|
||||
Power Cycles: 88
|
||||
Power On Hours: 2,642
|
||||
Unsafe Shutdowns: 51
|
||||
Media and Data Integrity Errors: 0
|
||||
Error Information Log Entries: 2
|
||||
Warning Comp. Temperature Time: 0
|
||||
Critical Comp. Temperature Time: 0
|
||||
Temperature Sensor 1: 68 Celsius
|
||||
|
||||
Error Information (NVMe Log 0x01, 16 of 16 entries)
|
||||
No Errors Logged
|
||||
|
||||
Self-test Log (NVMe Log 0x06)
|
||||
Self-test status: No self-test in progress
|
||||
No Self-tests Logged
|
||||
|
72
NVMe/Team/TM8/TM8FP6512G/C6C4090244BD
Normal file
72
NVMe/Team/TM8/TM8FP6512G/C6C4090244BD
Normal file
@@ -0,0 +1,72 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p11 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Number: TEAM TM8FP6512G
|
||||
Serial Number: --
|
||||
Firmware Version: EDFOE0.3
|
||||
PCI Vendor/Subsystem ID: 0x1987
|
||||
IEEE OUI Identifier: 0x6479a7
|
||||
Total NVM Capacity: 512,110,190,592 [512 GB]
|
||||
Unallocated NVM Capacity: 0
|
||||
Controller ID: 1
|
||||
NVMe Version: 1.3
|
||||
Number of Namespaces: 1
|
||||
Namespace 1 Size/Capacity: 512,110,190,592 [512 GB]
|
||||
Namespace 1 Formatted LBA Size: 512
|
||||
Namespace 1 IEEE EUI-64: 6479a7 ...
|
||||
Local Time is: Sat Jun 8 08:40:46 2024 PDT
|
||||
Firmware Updates (0x12): 1 Slot, no Reset required
|
||||
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
|
||||
Optional NVM Commands (0x005e): Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat Timestmp
|
||||
Log Page Attributes (0x0a): Cmd_Eff_Lg Telmtry_Lg
|
||||
Maximum Data Transfer Size: 64 Pages
|
||||
Warning Comp. Temp. Threshold: 85 Celsius
|
||||
Critical Comp. Temp. Threshold: 90 Celsius
|
||||
|
||||
Supported Power States
|
||||
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
|
||||
0 + 4.50W - - 0 0 0 0 0 0
|
||||
1 + 2.70W - - 1 1 1 1 0 0
|
||||
2 + 2.16W - - 2 2 2 2 0 0
|
||||
3 - 0.0700W - - 3 3 3 3 1000 1000
|
||||
4 - 0.0050W - - 4 4 4 4 5000 50000
|
||||
|
||||
Supported LBA Sizes (NSID 0x1)
|
||||
Id Fmt Data Metadt Rel_Perf
|
||||
0 + 512 0 1
|
||||
1 - 4096 0 0
|
||||
|
||||
=== START OF SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
SMART/Health Information (NVMe Log 0x02)
|
||||
Critical Warning: 0x00
|
||||
Temperature: 49 Celsius
|
||||
Available Spare: 100%
|
||||
Available Spare Threshold: 5%
|
||||
Percentage Used: 0%
|
||||
Data Units Read: 831 [425 MB]
|
||||
Data Units Written: 6,651 [3.40 GB]
|
||||
Host Read Commands: 22,744
|
||||
Host Write Commands: 62,841
|
||||
Controller Busy Time: 0
|
||||
Power Cycles: 8
|
||||
Power On Hours: 0
|
||||
Unsafe Shutdowns: 5
|
||||
Media and Data Integrity Errors: 0
|
||||
Error Information Log Entries: 0
|
||||
Warning Comp. Temperature Time: 0
|
||||
Critical Comp. Temperature Time: 0
|
||||
Temperature Sensor 1: 73 Celsius
|
||||
|
||||
Error Information (NVMe Log 0x01, 16 of 16 entries)
|
||||
No Errors Logged
|
||||
|
||||
Self-test Log (NVMe Log 0x06)
|
||||
Self-test status: No self-test in progress
|
||||
Num Test_Description Status Power_on_Hours Failing_LBA NSID Seg SCT Code
|
||||
0 Extended Completed without error 0 - - - - -
|
||||
1 Short Completed without error 0 - - - - -
|
||||
2 Short Completed without error 0 - - - - -
|
||||
|
69
NVMe/Team/TM8/TM8FPD001T/D26583326BF5
Normal file
69
NVMe/Team/TM8/TM8FPD001T/D26583326BF5
Normal file
@@ -0,0 +1,69 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p9 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Number: TEAM TM8FPD001T
|
||||
Serial Number: --
|
||||
Firmware Version: APF1M3R1
|
||||
PCI Vendor/Subsystem ID: 0x1ed0
|
||||
IEEE OUI Identifier: 0x2c3ebf
|
||||
Total NVM Capacity: 1,024,209,543,168 [1.02 TB]
|
||||
Unallocated NVM Capacity: 0
|
||||
Controller ID: 1
|
||||
NVMe Version: 1.3
|
||||
Number of Namespaces: 1
|
||||
Namespace 1 Size/Capacity: 1,024,209,543,168 [1.02 TB]
|
||||
Namespace 1 Formatted LBA Size: 512
|
||||
Namespace 1 IEEE EUI-64: 2c3ebf ...
|
||||
Local Time is: Fri Jan 26 02:38:10 2024 UTC
|
||||
Firmware Updates (0x12): 1 Slot, no Reset required
|
||||
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
|
||||
Optional NVM Commands (0x0056): Wr_Unc DS_Mngmt Sav/Sel_Feat Timestmp
|
||||
Log Page Attributes (0x0a): Cmd_Eff_Lg Telmtry_Lg
|
||||
Maximum Data Transfer Size: 64 Pages
|
||||
Warning Comp. Temp. Threshold: 80 Celsius
|
||||
Critical Comp. Temp. Threshold: 85 Celsius
|
||||
|
||||
Supported Power States
|
||||
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
|
||||
0 + 3.50W - - 0 0 0 0 0 0
|
||||
1 + 1.90W - - 1 1 1 1 0 0
|
||||
2 + 1.50W - - 2 2 2 2 0 0
|
||||
3 - 0.0700W - - 3 3 3 3 1000 1000
|
||||
4 - 0.0050W - - 4 4 4 4 5000 45000
|
||||
|
||||
Supported LBA Sizes (NSID 0x1)
|
||||
Id Fmt Data Metadt Rel_Perf
|
||||
0 + 512 0 1
|
||||
1 - 4096 0 0
|
||||
|
||||
=== START OF SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
SMART/Health Information (NVMe Log 0x02)
|
||||
Critical Warning: 0x00
|
||||
Temperature: 41 Celsius
|
||||
Available Spare: 100%
|
||||
Available Spare Threshold: 5%
|
||||
Percentage Used: 0%
|
||||
Data Units Read: 9,768 [5.00 GB]
|
||||
Data Units Written: 389,016 [199 GB]
|
||||
Host Read Commands: 215,396
|
||||
Host Write Commands: 6,394,759
|
||||
Controller Busy Time: 6
|
||||
Power Cycles: 11
|
||||
Power On Hours: 971
|
||||
Unsafe Shutdowns: 9
|
||||
Media and Data Integrity Errors: 0
|
||||
Error Information Log Entries: 0
|
||||
Warning Comp. Temperature Time: 0
|
||||
Critical Comp. Temperature Time: 0
|
||||
Temperature Sensor 1: 57 Celsius
|
||||
|
||||
Error Information (NVMe Log 0x01, 16 of 16 entries)
|
||||
No Errors Logged
|
||||
|
||||
Self-test Log (NVMe Log 0x06)
|
||||
Self-test status: No self-test in progress
|
||||
No Self-tests Logged
|
||||
|
69
NVMe/Team/TM8/TM8FPD512G/3FD376507C11
Normal file
69
NVMe/Team/TM8/TM8FPD512G/3FD376507C11
Normal file
@@ -0,0 +1,69 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p5 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Number: TEAM TM8FPD512G
|
||||
Serial Number: --
|
||||
Firmware Version: H221124a
|
||||
PCI Vendor/Subsystem ID: 0x1e4b
|
||||
IEEE OUI Identifier: 0x000000
|
||||
Total NVM Capacity: 512,110,190,592 [512 GB]
|
||||
Unallocated NVM Capacity: 0
|
||||
Controller ID: 0
|
||||
NVMe Version: 1.4
|
||||
Number of Namespaces: 1
|
||||
Namespace 1 Size/Capacity: 512,110,190,592 [512 GB]
|
||||
Namespace 1 Formatted LBA Size: 512
|
||||
Namespace 1 IEEE EUI-64: 000000 ...
|
||||
Local Time is: Sat Dec 9 12:11:34 2023 EST
|
||||
Firmware Updates (0x1a): 5 Slots, no Reset required
|
||||
Optional Admin Commands (0x0017): Security Format Frmw_DL Self_Test
|
||||
Optional NVM Commands (0x001f): Comp Wr_Unc DS_Mngmt Wr_Zero Sav/Sel_Feat
|
||||
Log Page Attributes (0x02): Cmd_Eff_Lg
|
||||
Maximum Data Transfer Size: 128 Pages
|
||||
Warning Comp. Temp. Threshold: 90 Celsius
|
||||
Critical Comp. Temp. Threshold: 95 Celsius
|
||||
|
||||
Supported Power States
|
||||
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
|
||||
0 + 6.50W - - 0 0 0 0 0 0
|
||||
1 + 5.80W - - 1 1 1 1 0 0
|
||||
2 + 3.60W - - 2 2 2 2 0 0
|
||||
3 - 0.7460W - - 3 3 3 3 5000 10000
|
||||
4 - 0.7260W - - 4 4 4 4 8000 45000
|
||||
|
||||
Supported LBA Sizes (NSID 0x1)
|
||||
Id Fmt Data Metadt Rel_Perf
|
||||
0 + 512 0 0
|
||||
|
||||
=== START OF SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
SMART/Health Information (NVMe Log 0x02)
|
||||
Critical Warning: 0x00
|
||||
Temperature: 42 Celsius
|
||||
Available Spare: 100%
|
||||
Available Spare Threshold: 1%
|
||||
Percentage Used: 9%
|
||||
Data Units Read: 536,075,632 [274 TB]
|
||||
Data Units Written: 28,592,331 [14.6 TB]
|
||||
Host Read Commands: 10,547,051,653
|
||||
Host Write Commands: 472,314,610
|
||||
Controller Busy Time: 16,185
|
||||
Power Cycles: 46
|
||||
Power On Hours: 5,540
|
||||
Unsafe Shutdowns: 30
|
||||
Media and Data Integrity Errors: 0
|
||||
Error Information Log Entries: 0
|
||||
Warning Comp. Temperature Time: 0
|
||||
Critical Comp. Temperature Time: 0
|
||||
Temperature Sensor 1: 42 Celsius
|
||||
Temperature Sensor 2: 50 Celsius
|
||||
|
||||
Error Information (NVMe Log 0x01, 16 of 64 entries)
|
||||
No Errors Logged
|
||||
|
||||
Self-test Log (NVMe Log 0x06)
|
||||
Self-test status: No self-test in progress
|
||||
No Self-tests Logged
|
||||
|
Reference in New Issue