smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.2-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Number: addlink M.2 PCIE G3x4 NVMe
|
||||
Serial Number: --
|
||||
Firmware Version: ECFM12.3
|
||||
PCI Vendor/Subsystem ID: 0x1987
|
||||
IEEE OUI Identifier: 0x6479a7
|
||||
Total NVM Capacity: 512,110,190,592 [512 GB]
|
||||
Unallocated NVM Capacity: 0
|
||||
Controller ID: 1
|
||||
NVMe Version: 1.3
|
||||
Number of Namespaces: 1
|
||||
Namespace 1 Size/Capacity: 512,110,190,592 [512 GB]
|
||||
Namespace 1 Formatted LBA Size: 512
|
||||
Namespace 1 IEEE EUI-64: 6479a7 ...
|
||||
Local Time is: Sun May 14 16:45:12 2023 IST
|
||||
Firmware Updates (0x12): 1 Slot, no Reset required
|
||||
Optional Admin Commands (0x0007): Security Format Frmw_DL
|
||||
Optional NVM Commands (0x0054): DS_Mngmt Sav/Sel_Feat Timestmp
|
||||
Log Page Attributes (0x08): Telmtry_Lg
|
||||
Maximum Data Transfer Size: 512 Pages
|
||||
Warning Comp. Temp. Threshold: 70 Celsius
|
||||
Critical Comp. Temp. Threshold: 90 Celsius
|
||||
|
||||
Supported Power States
|
||||
St Op Max Active Idle RL RT WL WT Ent_Lat Ex_Lat
|
||||
0 + 8.12W - - 0 0 0 0 0 0
|
||||
1 + 6.40W - - 1 1 1 1 0 0
|
||||
2 + 5.54W - - 2 2 2 2 0 0
|
||||
3 - 0.0490W - - 3 3 3 3 2000 2000
|
||||
4 - 0.0018W - - 4 4 4 4 25000 25000
|
||||
|
||||
Supported LBA Sizes (NSID 0x1)
|
||||
Id Fmt Data Metadt Rel_Perf
|
||||
0 + 512 0 2
|
||||
1 - 4096 0 1
|
||||
|
||||
=== START OF SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
SMART/Health Information (NVMe Log 0x02)
|
||||
Critical Warning: 0x00
|
||||
Temperature: 30 Celsius
|
||||
Available Spare: 100%
|
||||
Available Spare Threshold: 5%
|
||||
Percentage Used: 6%
|
||||
Data Units Read: 31,409,531 [16.0 TB]
|
||||
Data Units Written: 46,117,630 [23.6 TB]
|
||||
Host Read Commands: 435,021,071
|
||||
Host Write Commands: 907,145,665
|
||||
Controller Busy Time: 1,578
|
||||
Power Cycles: 2,560
|
||||
Power On Hours: 12,356
|
||||
Unsafe Shutdowns: 87
|
||||
Media and Data Integrity Errors: 0
|
||||
Error Information Log Entries: 1,546
|
||||
Warning Comp. Temperature Time: 0
|
||||
Critical Comp. Temperature Time: 0
|
||||
|
||||
Error Information (NVMe Log 0x01, 16 of 63 entries)
|
||||
No Errors Logged
|
||||
|