smartctl 7.4 2023-08-01 r5530 [FreeBSD 13.2-RELEASE-p4 amd64] (local build)
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
=== START OF INFORMATION SECTION ===
Device Model: Crucial_FCCT256M550SSD1
Serial Number: --
LU WWN Device Id: 5 00a075 ...
Firmware Version: MU02
User Capacity: 256,060,514,304 bytes [256 GB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: Solid State Device
Form Factor: 2.5 inches
TRIM Command: Available, deterministic, zeroed
Device is: Not in smartctl database 7.3/5528
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 6
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
Local Time is: Fri Nov 3 08:16:40 2023 -05
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
AAM feature is: Unavailable
APM level is: 254 (maximum performance)
Rd look-ahead is: Enabled
Write cache is: Enabled
DSN feature is: Unavailable
ATA Security is: Disabled, frozen [SEC2]
Wt Cache Reorder: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x80) Offline data collection activity
was never started.
Auto Offline Data Collection: Enabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: ( 1190) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 3) minutes.
Conveyance self-test routine
recommended polling time: ( 3) minutes.
SCT capabilities: (0x0035) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
1 Raw_Read_Error_Rate POSR-K 100 100 000 - 25074422
5 Reallocated_Sector_Ct PO--CK 086 086 000 - 325
9 Power_On_Hours -O--CK 100 100 000 - 44470
12 Power_Cycle_Count -O--CK 100 100 000 - 93617
171 Unknown_Attribute -O--CK 100 100 000 - 0
172 Unknown_Attribute -O--CK 100 100 000 - 0
173 Unknown_Attribute -O--CK 154 154 000 - 6076
174 Unknown_Attribute -O--CK 100 100 000 - 80
180 Unused_Rsvd_Blk_Cnt_Tot PO--CK 000 000 000 - 1834
183 Runtime_Bad_Block -O--CK 100 100 000 - 0
184 End-to-End_Error -O--CK 100 100 000 - 0
187 Reported_Uncorrect -O--CK 100 100 000 - 29
194 Temperature_Celsius -O---K 065 052 000 - 35 (Min/Max 19/48)
196 Reallocated_Event_Count -O--CK 100 100 000 - 325
197 Current_Pending_Sector -O--CK 100 100 000 - 0
198 Offline_Uncorrectable ----CK 100 100 000 - 0
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0
202 Unknown_SSD_Attribute P---CK 154 154 000 - 202
206 Unknown_SSD_Attribute -OSR-- 100 100 000 - 0
210 Unknown_Attribute -O--CK 100 100 000 - 58
246 Unknown_Attribute -O--CK 100 100 000 - 158015213858
247 Unknown_Attribute -O--CK 100 100 000 - 4973367253
248 Unknown_Attribute -O--CK 100 100 000 - 1472163843
||||||_ K auto-keep
|||||__ C event count
||||___ R error rate
|||____ S speed/performance
||_____ O updated online
|______ P prefailure warning
General Purpose Log Directory Version 1
SMART Log Directory Version 1 [multi-sector log support]
Address Access R/W Size Description
0x00 GPL,SL R/O 1 Log Directory
0x01 SL R/O 1 Summary SMART error log
0x02 SL R/O 51 Comprehensive SMART error log
0x03 GPL R/O 16383 Ext. Comprehensive SMART error log
0x04 GPL,SL R/O 255 Device Statistics log
0x06 SL R/O 1 SMART self-test log
0x07 GPL R/O 1 Extended self-test log
0x09 SL R/W 1 Selective self-test log
0x10 GPL R/O 1 NCQ Command Error log
0x11 GPL R/O 1 SATA Phy Event Counters log
0x13 GPL R/O 1 SATA NCQ Send and Receive log
0x24 GPL R/O 429 Current Device Internal Status Data log
0x25 GPL R/O 145 Saved Device Internal Status Data log
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
0xa0 GPL VS 2000 Device vendor specific log
0xa0 SL VS 208 Device vendor specific log
0xa1-0xbf GPL,SL VS 1 Device vendor specific log
0xc0 GPL,SL VS 80 Device vendor specific log
0xc1-0xdf GPL,SL VS 1 Device vendor specific log
0xe0 GPL,SL R/W 1 SCT Command/Status
0xe1 GPL,SL R/W 1 SCT Data Transfer
SMART Extended Comprehensive Error Log Version: 1 (16383 sectors)
Device Error Count: 29
CR = Command Register
FEATR = Features Register
COUNT = Count (was: Sector Count) Register
LBA_48 = Upper bytes of LBA High/Mid/Low Registers ] ATA-8
LH = LBA High (was: Cylinder High) Register ] LBA
LM = LBA Mid (was: Cylinder Low) Register ] Register
LL = LBA Low (was: Sector Number) Register ]
DV = Device (was: Device/Head) Register
DC = Device Control Register
ER = Error register
ST = Status register
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
Error 29 [28] occurred at disk power-on lifetime: 12556 hours (523 days + 4 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 50 00 00 0b 4b d3 68 40 08 Error: UNC at LBA = 0x0b4bd368 = 189518696
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 00 00 50 00 00 0b 4b d6 50 40 08 26d+01:36:07.040 READ FPDMA QUEUED
60 00 00 00 40 00 00 0b 4b d3 68 40 08 26d+01:36:07.040 READ FPDMA QUEUED
60 00 00 00 40 00 00 0b 4b c7 10 40 08 26d+01:36:07.040 READ FPDMA QUEUED
60 00 00 00 08 00 00 0b 4b c4 e0 40 08 26d+01:36:07.040 READ FPDMA QUEUED
60 00 00 00 08 00 00 0b 4b c4 d8 40 08 26d+01:36:07.040 READ FPDMA QUEUED
Error 28 [27] occurred at disk power-on lifetime: 4563 hours (190 days + 3 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 08 00 00 17 72 86 50 40 08 Error: UNC at LBA = 0x17728650 = 393381456
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 00 00 08 00 00 1d 92 00 10 40 08 41d+00:21:38.112 READ FPDMA QUEUED
60 00 00 00 08 00 00 1d 91 dc c0 40 08 41d+00:21:38.112 READ FPDMA QUEUED
60 00 00 00 18 00 00 17 72 86 50 40 08 41d+00:21:38.112 READ FPDMA QUEUED
60 00 00 00 08 00 00 17 72 54 b0 40 08 41d+00:21:38.112 READ FPDMA QUEUED
60 00 00 00 08 00 00 17 72 53 30 40 08 41d+00:21:38.112 READ FPDMA QUEUED
Error 27 [26] occurred at disk power-on lifetime: 3213 hours (133 days + 21 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 30 00 00 01 42 f5 38 40 08 Error: UNC at LBA = 0x0142f538 = 21165368
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 00 00 30 00 00 01 44 cd 50 40 08 34d+11:07:25.408 READ FPDMA QUEUED
60 00 00 00 68 00 00 01 42 f5 38 40 08 34d+11:07:25.408 READ FPDMA QUEUED
60 00 00 00 18 00 00 01 04 ce e8 40 08 34d+11:07:25.408 READ FPDMA QUEUED
60 00 00 00 38 00 00 01 44 cd 10 40 08 34d+11:07:25.408 READ FPDMA QUEUED
60 00 00 00 08 00 00 01 44 cd 48 40 08 34d+11:07:25.408 READ FPDMA QUEUED
Error 26 [25] occurred at disk power-on lifetime: 2585 hours (107 days + 17 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 08 00 00 1b d4 cf 90 40 08 Error: UNC at LBA = 0x1bd4cf90 = 466931600
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 00 00 08 00 00 1c 01 a8 50 40 08 8d+07:34:25.408 READ FPDMA QUEUED
60 00 00 00 08 00 00 1c 00 78 e0 40 08 8d+07:34:25.408 READ FPDMA QUEUED
60 00 00 00 08 00 00 1b de 47 78 40 08 8d+07:34:25.408 READ FPDMA QUEUED
60 00 00 00 08 00 00 1b db f3 80 40 08 8d+07:34:25.408 READ FPDMA QUEUED
60 00 00 00 08 00 00 1b db 58 f0 40 08 8d+07:34:25.408 READ FPDMA QUEUED
Error 25 [24] occurred at disk power-on lifetime: 2585 hours (107 days + 17 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 08 00 00 1b d4 cf 90 40 08 Error: UNC at LBA = 0x1bd4cf90 = 466931600
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 00 00 08 00 00 1c 01 a8 50 40 08 8d+07:34:25.408 READ FPDMA QUEUED
60 00 00 00 08 00 00 1c 00 78 e0 40 08 8d+07:34:25.408 READ FPDMA QUEUED
60 00 00 00 08 00 00 1b de 47 78 40 08 8d+07:34:25.408 READ FPDMA QUEUED
60 00 00 00 08 00 00 1b db f3 80 40 08 8d+07:34:25.408 READ FPDMA QUEUED
60 00 00 00 08 00 00 1b db 58 f0 40 08 8d+07:34:25.408 READ FPDMA QUEUED
Error 24 [23] occurred at disk power-on lifetime: 2585 hours (107 days + 17 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 08 00 00 1b d4 cf 90 40 08 Error: WP at LBA = 0x1bd4cf90 = 466931600
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
61 00 00 00 08 00 00 1c 00 89 58 40 08 8d+07:34:25.408 WRITE FPDMA QUEUED
61 00 00 00 18 00 00 1c 00 38 88 40 08 8d+07:34:25.408 WRITE FPDMA QUEUED
60 00 00 00 08 00 00 1c 01 a8 50 40 08 8d+07:34:25.408 READ FPDMA QUEUED
60 00 00 00 08 00 00 1c 00 78 e0 40 08 8d+07:34:25.408 READ FPDMA QUEUED
60 00 00 00 08 00 00 1b de 47 78 40 08 8d+07:34:25.408 READ FPDMA QUEUED
Error 23 [22] occurred at disk power-on lifetime: 2585 hours (107 days + 17 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 08 00 00 1b d4 cf 90 40 08 Error: UNC at LBA = 0x1bd4cf90 = 466931600
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 00 00 08 00 00 1b de 47 78 40 08 8d+07:34:25.408 READ FPDMA QUEUED
60 00 00 00 08 00 00 1b db f3 80 40 08 8d+07:34:25.408 READ FPDMA QUEUED
60 00 00 00 08 00 00 1b db 58 f0 40 08 8d+07:34:25.408 READ FPDMA QUEUED
60 00 00 00 08 00 00 1b d8 7c c0 40 08 8d+07:34:25.408 READ FPDMA QUEUED
60 00 00 00 08 00 00 1b d5 48 68 40 08 8d+07:34:25.408 READ FPDMA QUEUED
Error 22 [21] occurred at disk power-on lifetime: 2554 hours (106 days + 10 hours)
When the command that caused the error occurred, the device was active or idle.
After command completion occurred, registers were:
ER -- ST COUNT LBA_48 LH LM LL DV DC
-- -- -- == -- == == == -- -- -- -- --
40 -- 51 00 88 00 00 09 c9 fe e8 40 08 Error: UNC at LBA = 0x09c9fee8 = 164232936
Commands leading to the command that caused the error were:
CR FEATR COUNT LBA_48 LH LM LL DV DC Powered_Up_Time Command/Feature_Name
-- == -- == -- == == == -- -- -- -- -- --------------- --------------------
60 00 03 00 88 00 00 09 c9 fe e8 40 08 7d+00:10:25.408 READ FPDMA QUEUED
2f 00 00 00 01 00 00 00 00 00 10 e0 08 7d+00:10:25.408 READ LOG EXT
61 00 00 00 08 00 00 1b 80 5e b0 40 08 7d+00:10:25.408 WRITE FPDMA QUEUED
60 00 03 00 88 00 00 09 c9 fe e8 40 08 7d+00:10:25.408 READ FPDMA QUEUED
2f 00 00 00 01 00 00 00 00 00 10 e0 08 7d+00:10:25.408 READ LOG EXT
SMART Extended Self-test Log Version: 1 (1 sectors)
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Vendor (0xff) Completed without error 00% 44356 -
# 2 Short offline Completed without error 00% 44328 -
# 3 Vendor (0xff) Completed without error 00% 44239 -
# 4 Vendor (0xff) Completed without error 00% 44224 -
# 5 Short offline Completed without error 00% 44209 -
# 6 Short offline Completed without error 00% 44209 -
# 7 Vendor (0xff) Completed without error 00% 42017 -
# 8 Vendor (0xff) Completed without error 00% 41177 -
# 9 Vendor (0xff) Completed without error 00% 36112 -
#10 Vendor (0xff) Completed without error 00% 32538 -
#11 Vendor (0xff) Completed without error 00% 25490 -
#12 Vendor (0xff) Completed without error 00% 25324 -
#13 Vendor (0xff) Completed without error 00% 25055 -
#14 Vendor (0xff) Completed without error 00% 24878 -
#15 Vendor (0xff) Completed without error 00% 24628 -
#16 Vendor (0xff) Completed without error 00% 23547 -
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
SCT Status Version: 3
SCT Version (vendor specific): 1 (0x0001)
Device State: Active (0)
Current Temperature: 35 Celsius
Power Cycle Min/Max Temperature: 26/36 Celsius
Lifetime Min/Max Temperature: 19/48 Celsius
Under/Over Temperature Limit Count: 0/0
SCT Temperature History Version: 2
Temperature Sampling Period: 1 minute
Temperature Logging Interval: 1 minute
Min/Max recommended Temperature: 0/70 Celsius
Min/Max Temperature Limit: -5/75 Celsius
Temperature History Size (Index): 478 (210)
SCT Error Recovery Control command not supported
Device Statistics (GP Log 0x04)
Page Offset Size Value Flags Description
0x01 ===== = = === == General Statistics (rev 2) ==
0x01 0x008 4 93617 --- Lifetime Power-On Resets
0x01 0x010 4 44470 --- Power-on Hours
0x01 0x018 6 158015213858 --- Logical Sectors Written
0x01 0x020 6 6550681855 --- Number of Write Commands
0x01 0x028 6 47751574245 --- Logical Sectors Read
0x01 0x030 6 1199598779 --- Number of Read Commands
0x04 ===== = = === == General Errors Statistics (rev 1) ==
0x04 0x008 4 29 --- Number of Reported Uncorrectable Errors
0x04 0x010 4 93573 --- Resets Between Cmd Acceptance and Completion
0x05 ===== = = === == Temperature Statistics (rev 1) ==
0x05 0x008 1 35 --- Current Temperature
0x05 0x010 1 34 --- Average Short Term Temperature
0x05 0x018 1 34 --- Average Long Term Temperature
0x05 0x020 1 48 --- Highest Temperature
0x05 0x028 1 19 --- Lowest Temperature
0x05 0x030 1 43 --- Highest Average Short Term Temperature
0x05 0x038 1 22 --- Lowest Average Short Term Temperature
0x05 0x040 1 41 --- Highest Average Long Term Temperature
0x05 0x048 1 25 --- Lowest Average Long Term Temperature
0x05 0x050 4 - --- Time in Over-Temperature
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
0x05 0x060 4 - --- Time in Under-Temperature
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
0x06 ===== = = === == Transport Statistics (rev 1) ==
0x06 0x008 4 100 --- Number of Hardware Resets
0x06 0x010 4 0 --- Number of ASR Events
0x06 0x018 4 0 --- Number of Interface CRC Errors
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
0x07 0x008 1 59 N-- Percentage Used Endurance Indicator
|||_ C monitored condition met
||__ D supports DSN
|___ N normalized value
Pending Defects log (GP Log 0x0c) not supported
SATA Phy Event Counters (GP Log 0x11)
ID Size Value Description
0x0001 4 0 Command failed due to ICRC error
0x000a 4 5 Device-to-host register FISes sent due to a COMRESET