smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.1-RELEASE-p8 amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Crucial/Micron Client SSDs
|
||||
Device Model: Micron_M550_MTFDDAK128MAY
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 00a075 ...
|
||||
Firmware Version: MU01
|
||||
User Capacity: 128,035,676,160 bytes [128 GB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: Solid State Device
|
||||
Form Factor: 2.5 inches
|
||||
TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Thu Jul 13 17:21:14 2023 CDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 254 (maximum performance)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x80) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 595) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 3) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 3) minutes.
|
||||
SCT capabilities: (0x0035) SCT Status supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 000 - 0
|
||||
5 Reallocate_NAND_Blk_Cnt PO--CK 100 100 000 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 71156
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 170
|
||||
171 Program_Fail_Count -O--CK 100 100 000 - 0
|
||||
172 Erase_Fail_Count -O--CK 100 100 000 - 0
|
||||
173 Ave_Block-Erase_Count -O--CK 068 068 000 - 965
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 76
|
||||
180 Unused_Reserve_NAND_Blk PO--CK 000 000 000 - 1036
|
||||
183 SATA_Interfac_Downshift -O--CK 100 100 000 - 0
|
||||
184 Error_Correction_Count -O--CK 100 100 000 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
194 Temperature_Celsius -O---K 066 062 000 - 34 (Min/Max 24/38)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 16
|
||||
197 Current_Pending_ECC_Cnt -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0
|
||||
202 Percent_Lifetime_Remain P---CK 068 068 000 - 32
|
||||
206 Write_Error_Rate -OSR-- 100 100 000 - 0
|
||||
210 Success_RAIN_Recov_Cnt -O--CK 100 100 000 - 0
|
||||
246 Total_LBAs_Written -O--CK 100 100 000 - 13859075380
|
||||
247 Host_Program_Page_Count -O--CK 100 100 000 - 572238232
|
||||
248 FTL_Program_Page_Count -O--CK 100 100 000 - 3217589229
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 51 Comprehensive SMART error log
|
||||
0x03 GPL R/O 16383 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 255 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x13 GPL R/O 1 SATA NCQ Send and Receive log
|
||||
0x24 GPL R/O 429 Current Device Internal Status Data log
|
||||
0x25 GPL R/O 145 Saved Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa0 GPL VS 2000 Device vendor specific log
|
||||
0xa0 SL VS 208 Device vendor specific log
|
||||
0xa1-0xbf GPL,SL VS 1 Device vendor specific log
|
||||
0xc0 GPL,SL VS 80 Device vendor specific log
|
||||
0xc1-0xdf GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (16383 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Short offline Completed without error 00% 5600 -
|
||||
# 2 Vendor (0xff) Completed without error 00% 5577 -
|
||||
# 3 Vendor (0xff) Completed without error 00% 5551 -
|
||||
# 4 Vendor (0xff) Completed without error 00% 5523 -
|
||||
# 5 Vendor (0xff) Completed without error 00% 5494 -
|
||||
# 6 Vendor (0xff) Completed without error 00% 5458 -
|
||||
# 7 Vendor (0xff) Completed without error 00% 5430 -
|
||||
# 8 Vendor (0xff) Completed without error 00% 5391 -
|
||||
# 9 Short offline Completed without error 00% 3829 -
|
||||
#10 Vendor (0xff) Completed without error 00% 2820 -
|
||||
#11 Vendor (0xff) Completed without error 00% 2784 -
|
||||
#12 Vendor (0xff) Completed without error 00% 2770 -
|
||||
#13 Vendor (0xff) Completed without error 00% 2740 -
|
||||
#14 Vendor (0xff) Completed without error 00% 2498 -
|
||||
#15 Vendor (0xff) Completed without error 00% 2455 -
|
||||
#16 Vendor (0xff) Completed without error 00% 2429 -
|
||||
#17 Vendor (0xff) Completed without error 00% 2386 -
|
||||
#18 Vendor (0xff) Completed without error 00% 2361 -
|
||||
#19 Vendor (0xff) Completed without error 00% 2338 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Completed [00% left] (57881389-57946924)
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: Active (0)
|
||||
Current Temperature: 34 Celsius
|
||||
Power Cycle Min/Max Temperature: 29/36 Celsius
|
||||
Lifetime Min/Max Temperature: 24/38 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (123)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 170 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 71156 --- Power-on Hours
|
||||
0x01 0x018 6 13859075380 --- Logical Sectors Written
|
||||
0x01 0x020 6 575447275 --- Number of Write Commands
|
||||
0x01 0x028 6 551737947 --- Logical Sectors Read
|
||||
0x01 0x030 6 12397733 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 159 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 34 --- Current Temperature
|
||||
0x05 0x010 1 34 --- Average Short Term Temperature
|
||||
0x05 0x018 1 33 --- Average Long Term Temperature
|
||||
0x05 0x020 1 38 --- Highest Temperature
|
||||
0x05 0x028 1 24 --- Lowest Temperature
|
||||
0x05 0x030 1 45 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 21 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 33 --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 20 --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 - --- Time in Over-Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 - --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 0 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 15 N-- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x000a 4 4 Device-to-host register FISes sent due to a COMRESET
|
||||
|
214
SSD/Micron/M550/M550_MTFDDAT064MAY/FF04A9E27A0E
Normal file
214
SSD/Micron/M550/M550_MTFDDAT064MAY/FF04A9E27A0E
Normal file
@@ -0,0 +1,214 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [FreeBSD 14.1-RELEASE-p5 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: Crucial/Micron Client SSDs
|
||||
Device Model: Micron_M550_MTFDDAT064MAY
|
||||
Serial Number: --
|
||||
LU WWN Device Id: 5 00a075 ...
|
||||
Firmware Version: MU01
|
||||
User Capacity: 50,000,000,000 bytes [50.0 GB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: Solid State Device
|
||||
Form Factor: < 1.8 inches
|
||||
TRIM Command: Available, deterministic, zeroed
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 6
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Mon Oct 21 16:18:11 2024 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 254 (maximum performance)
|
||||
Rd look-ahead is: Enabled
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, NOT FROZEN [SEC1]
|
||||
Wt Cache Reorder: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x84) Offline data collection activity
|
||||
was suspended by an interrupting command from host.
|
||||
Auto Offline Data Collection: Enabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 110) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x7b) SMART execute Offline immediate.
|
||||
Auto Offline data collection on/off support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0003) Saves SMART data before entering
|
||||
power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 3) minutes.
|
||||
Conveyance self-test routine
|
||||
recommended polling time: ( 3) minutes.
|
||||
SCT capabilities: (0x0035) SCT Status supported.
|
||||
SCT Feature Control supported.
|
||||
SCT Data Table supported.
|
||||
|
||||
SMART Attributes Data Structure revision number: 16
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-K 100 100 000 - 256
|
||||
5 Reallocate_NAND_Blk_Cnt PO--CK 100 100 000 - 0
|
||||
9 Power_On_Hours -O--CK 100 100 000 - 38629
|
||||
12 Power_Cycle_Count -O--CK 100 100 000 - 97
|
||||
171 Program_Fail_Count -O--CK 100 100 000 - 0
|
||||
172 Erase_Fail_Count -O--CK 100 100 000 - 0
|
||||
173 Ave_Block-Erase_Count -O--CK 089 089 000 - 353
|
||||
174 Unexpect_Power_Loss_Ct -O--CK 100 100 000 - 95
|
||||
180 Unused_Reserve_NAND_Blk PO--CK 000 000 000 - 475
|
||||
183 SATA_Interfac_Downshift -O--CK 100 100 000 - 2
|
||||
184 Error_Correction_Count -O--CK 100 100 000 - 0
|
||||
187 Reported_Uncorrect -O--CK 100 100 000 - 0
|
||||
194 Temperature_Celsius -O---K 029 012 000 - 71 (Min/Max 25/88)
|
||||
196 Reallocated_Event_Count -O--CK 100 100 000 - 16
|
||||
197 Current_Pending_ECC_Cnt -O--CK 100 100 000 - 0
|
||||
198 Offline_Uncorrectable ----CK 100 100 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 100 100 000 - 0
|
||||
202 Percent_Lifetime_Remain P---CK 089 089 000 - 11
|
||||
206 Write_Error_Rate -OSR-- 100 100 000 - 0
|
||||
210 Success_RAIN_Recov_Cnt -O--CK 100 100 000 - 0
|
||||
246 Total_LBAs_Written -O--CK 100 100 000 - 17247210409
|
||||
247 Host_Program_Page_Count -O--CK 100 100 000 - 630581574
|
||||
248 FTL_Program_Page_Count -O--CK 100 100 000 - 839127838
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 51 Comprehensive SMART error log
|
||||
0x03 GPL R/O 16383 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 255 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 1 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x13 GPL R/O 1 SATA NCQ Send and Receive log
|
||||
0x24 GPL R/O 429 Current Device Internal Status Data log
|
||||
0x25 GPL R/O 145 Saved Device Internal Status Data log
|
||||
0x30 GPL,SL R/O 9 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
0xa0 GPL VS 2000 Device vendor specific log
|
||||
0xa0 SL VS 208 Device vendor specific log
|
||||
0xa1-0xbf GPL,SL VS 1 Device vendor specific log
|
||||
0xc0 GPL,SL VS 80 Device vendor specific log
|
||||
0xc1-0xdf GPL,SL VS 1 Device vendor specific log
|
||||
0xe0 GPL,SL R/W 1 SCT Command/Status
|
||||
0xe1 GPL,SL R/W 1 SCT Data Transfer
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (16383 sectors)
|
||||
No Errors Logged
|
||||
|
||||
SMART Extended Self-test Log Version: 1 (1 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Vendor (0xff) Completed without error 00% 38628 -
|
||||
# 2 Vendor (0xff) Completed without error 00% 38616 -
|
||||
# 3 Vendor (0xff) Completed without error 00% 38589 -
|
||||
# 4 Vendor (0xff) Completed without error 00% 38563 -
|
||||
# 5 Vendor (0xff) Completed without error 00% 38534 -
|
||||
# 6 Vendor (0xff) Completed without error 00% 38509 -
|
||||
# 7 Vendor (0xff) Completed without error 00% 270 -
|
||||
# 8 Vendor (0xff) Completed without error 00% 256 -
|
||||
# 9 Vendor (0xff) Completed without error 00% 243 -
|
||||
#10 Vendor (0xff) Completed without error 00% 223 -
|
||||
#11 Vendor (0xff) Completed without error 00% 203 -
|
||||
#12 Vendor (0xff) Completed without error 00% 183 -
|
||||
#13 Vendor (0xff) Completed without error 00% 163 -
|
||||
#14 Vendor (0xff) Completed without error 00% 143 -
|
||||
|
||||
SMART Selective self-test log data structure revision number 1
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Status Version: 3
|
||||
SCT Version (vendor specific): 1 (0x0001)
|
||||
Device State: SMART Off-line Data Collection executing in background (4)
|
||||
Current Temperature: 71 Celsius
|
||||
Power Cycle Min/Max Temperature: 31/72 Celsius
|
||||
Lifetime Min/Max Temperature: 25/88 Celsius
|
||||
Under/Over Temperature Limit Count: 0/0
|
||||
|
||||
SCT Temperature History Version: 2
|
||||
Temperature Sampling Period: 1 minute
|
||||
Temperature Logging Interval: 1 minute
|
||||
Min/Max recommended Temperature: 0/70 Celsius
|
||||
Min/Max Temperature Limit: -5/75 Celsius
|
||||
Temperature History Size (Index): 478 (2)
|
||||
|
||||
SCT Error Recovery Control command not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (rev 2) ==
|
||||
0x01 0x008 4 97 --- Lifetime Power-On Resets
|
||||
0x01 0x010 4 38629 --- Power-on Hours
|
||||
0x01 0x018 6 17247210409 --- Logical Sectors Written
|
||||
0x01 0x020 6 439687363 --- Number of Write Commands
|
||||
0x01 0x028 6 7345546366 --- Logical Sectors Read
|
||||
0x01 0x030 6 136013377 --- Number of Read Commands
|
||||
0x04 ===== = = === == General Errors Statistics (rev 1) ==
|
||||
0x04 0x008 4 0 --- Number of Reported Uncorrectable Errors
|
||||
0x04 0x010 4 82 --- Resets Between Cmd Acceptance and Completion
|
||||
0x05 ===== = = === == Temperature Statistics (rev 1) ==
|
||||
0x05 0x008 1 71 --- Current Temperature
|
||||
0x05 0x010 1 68 --- Average Short Term Temperature
|
||||
0x05 0x018 1 65 --- Average Long Term Temperature
|
||||
0x05 0x020 1 88 --- Highest Temperature
|
||||
0x05 0x028 1 25 --- Lowest Temperature
|
||||
0x05 0x030 1 86 --- Highest Average Short Term Temperature
|
||||
0x05 0x038 1 38 --- Lowest Average Short Term Temperature
|
||||
0x05 0x040 1 84 --- Highest Average Long Term Temperature
|
||||
0x05 0x048 1 61 --- Lowest Average Long Term Temperature
|
||||
0x05 0x050 4 461631 --- Time in Over-Temperature
|
||||
0x05 0x058 1 70 --- Specified Maximum Operating Temperature
|
||||
0x05 0x060 4 - --- Time in Under-Temperature
|
||||
0x05 0x068 1 0 --- Specified Minimum Operating Temperature
|
||||
0x06 ===== = = === == Transport Statistics (rev 1) ==
|
||||
0x06 0x008 4 0 --- Number of Hardware Resets
|
||||
0x06 0x010 4 0 --- Number of ASR Events
|
||||
0x06 0x018 4 0 --- Number of Interface CRC Errors
|
||||
0x07 ===== = = === == Solid State Device Statistics (rev 1) ==
|
||||
0x07 0x008 1 27 N-- Percentage Used Endurance Indicator
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 4 0 Command failed due to ICRC error
|
||||
0x000a 4 8 Device-to-host register FISes sent due to a COMRESET
|
||||
|
Reference in New Issue
Block a user