mirror of
https://github.com/bsdhw/SMART.git
synced 2025-05-31 16:21:41 +05:30
Update of reports (new: 6895, modified: 16)
This commit is contained in:
172
SSD/SK hynix/HFS128/HFS128G39MND-3310A/4C7EA12702E5
Normal file
172
SSD/SK hynix/HFS128/HFS128G39MND-3310A/4C7EA12702E5
Normal file
@@ -0,0 +1,172 @@
|
||||
smartctl 7.3 2022-02-28 r5338 [FreeBSD 13.2-RELEASE amd64] (local build)
|
||||
Copyright (C) 2002-22, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: SK hynix SATA SSDs
|
||||
Device Model: HFS128G39MND-3310A
|
||||
Serial Number: --
|
||||
Firmware Version: 20002P00
|
||||
User Capacity: 128,035,676,160 bytes [128 GB]
|
||||
Sector Size: 512 bytes logical/physical
|
||||
Rotation Rate: Solid State Device
|
||||
TRIM Command: Available, deterministic
|
||||
Device is: In smartctl database 7.3/5319
|
||||
ATA Version is: ATA8-ACS (minor revision not indicated)
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Fri May 26 12:26:33 2023 PDT
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
AAM feature is: Unavailable
|
||||
APM level is: 254 (maximum performance)
|
||||
Rd look-ahead is: Unavailable
|
||||
Write cache is: Enabled
|
||||
DSN feature is: Unavailable
|
||||
ATA Security is: Disabled, frozen [SEC2]
|
||||
Wt Cache Reorder: Unavailable
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x02) Offline data collection activity
|
||||
was completed without error.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 0) The previous self-test routine completed
|
||||
without error or no self-test has ever
|
||||
been run.
|
||||
Total time to complete Offline
|
||||
data collection: ( 463) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x59) SMART execute Offline immediate.
|
||||
No Auto Offline data collection support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
Selective Self-test supported.
|
||||
SMART capabilities: (0x0002) Does not save SMART data before
|
||||
entering power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 1) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
|
||||
SMART Attributes Data Structure revision number: 0
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAGS VALUE WORST THRESH FAIL RAW_VALUE
|
||||
1 Raw_Read_Error_Rate POSR-- 166 166 006 - 0
|
||||
5 Retired_Block_Count -O--CK 253 253 036 - 0
|
||||
9 Power_On_Hours -O--CK 096 096 000 - 4398
|
||||
12 Power_Cycle_Count -O--CK 100 100 020 - 4330
|
||||
100 Total_Erase_Count -O--CK 100 100 000 - 3241491
|
||||
170 Unknown_SK_hynix_Attrib -O--CK 100 100 000 - 22
|
||||
171 Program_Fail_Count -O--CK 253 253 000 - 0
|
||||
172 Erase_Fail_Count -O--CK 253 253 000 - 0
|
||||
173 Wear_Leveling_Count -O--CK 097 097 000 - 91
|
||||
174 Unexpect_Power_Loss_Ct ----CK 100 100 000 - 748
|
||||
177 Wear_Leveling_Count -O--CK 097 097 000 - 91
|
||||
178 Used_Rsvd_Blk_Cnt_Chip -O--CK 100 100 000 - 22
|
||||
180 Erase_Fail_Count -O--CK 100 100 000 - 1946
|
||||
181 Non4k_Aligned_Access -O--CK 253 253 000 - 0
|
||||
182 Erase_Fail_Count_Total -O--CK 253 253 000 - 0
|
||||
183 SATA_Downshift_Count -O--CK 253 253 000 - 0
|
||||
184 End-to-End_Error -O--CK 253 253 000 - 0
|
||||
187 Reported_Uncorrect -O--CK 253 253 000 - 0
|
||||
194 Temperature_Celsius -O---- 035 000 000 - 35 (Min/Max 17/64)
|
||||
195 Hardware_ECC_Recovered -O--CK 253 253 000 - 0
|
||||
199 UDMA_CRC_Error_Count -O--CK 253 253 000 - 0
|
||||
201 Percent_Lifetime_Remain -OSR-- 100 100 000 - 0
|
||||
204 Soft_ECC_Correction -OSR-- 100 100 000 - 0
|
||||
231 SSD_Life_Left PO--CK 253 253 010 - 0
|
||||
233 Media_Wearout_Indicator -O--CK 100 100 000 - 11031
|
||||
234 Unknown_SK_hynix_Attrib -O--CK 100 100 --- - 11031
|
||||
241 Total_Writes_GB -O--CK 100 100 --- - 5561
|
||||
242 Total_Reads_GB -O--CK 100 100 --- - 10455
|
||||
250 Read_Retry_Count -O--CK 100 100 --- - 39473
|
||||
||||||_ K auto-keep
|
||||
|||||__ C event count
|
||||
||||___ R error rate
|
||||
|||____ S speed/performance
|
||||
||_____ O updated online
|
||||
|______ P prefailure warning
|
||||
|
||||
General Purpose Log Directory Version 1
|
||||
SMART Log Directory Version 1 [multi-sector log support]
|
||||
Address Access R/W Size Description
|
||||
0x00 GPL,SL R/O 1 Log Directory
|
||||
0x01 SL R/O 1 Summary SMART error log
|
||||
0x02 SL R/O 4 Comprehensive SMART error log
|
||||
0x03 GPL R/O 5 Ext. Comprehensive SMART error log
|
||||
0x04 GPL,SL R/O 8 Device Statistics log
|
||||
0x06 SL R/O 1 SMART self-test log
|
||||
0x07 GPL R/O 2 Extended self-test log
|
||||
0x09 SL R/W 1 Selective self-test log
|
||||
0x10 GPL R/O 1 NCQ Command Error log
|
||||
0x11 GPL R/O 1 SATA Phy Event Counters log
|
||||
0x30 GPL R/O 8 IDENTIFY DEVICE data log
|
||||
0x80-0x9f GPL,SL R/W 16 Host vendor specific log
|
||||
|
||||
SMART Extended Comprehensive Error Log Version: 1 (5 sectors)
|
||||
No Errors Logged
|
||||
|
||||
Warning! SMART Extended Self-test Log Structure (1/2) error: invalid SMART checksum.
|
||||
SMART Extended Self-test Log Version: 1 (2 sectors)
|
||||
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
|
||||
# 1 Extended offline Completed without error 00% 3200 -
|
||||
# 2 Short offline Completed without error 00% 3198 -
|
||||
# 3 Short offline Completed without error 00% 3196 -
|
||||
# 4 Short offline Completed without error 00% 3189 -
|
||||
# 5 Short offline Completed without error 00% 3173 -
|
||||
# 6 Extended offline Completed without error 00% 3171 -
|
||||
# 7 Short offline Completed without error 00% 3163 -
|
||||
# 8 Short offline Completed without error 00% 3140 -
|
||||
# 9 Short offline Completed without error 00% 3117 -
|
||||
#10 Short offline Completed without error 00% 3094 -
|
||||
#11 Short offline Completed without error 00% 3070 -
|
||||
#12 Short offline Completed without error 00% 3059 -
|
||||
#13 Short offline Completed without error 00% 3058 -
|
||||
#14 Extended offline Completed without error 00% 3053 -
|
||||
#15 Short offline Completed without error 00% 3051 -
|
||||
#16 Short offline Completed without error 00% 3046 -
|
||||
#17 Short offline Completed without error 00% 3043 -
|
||||
#18 Short offline Completed without error 00% 3040 -
|
||||
#19 Short offline Completed without error 00% 1942 -
|
||||
#20 Short offline Completed without error 00% 1942 -
|
||||
|
||||
Warning! SMART Selective Self-Test Log Structure error: invalid SMART checksum.
|
||||
SMART Selective self-test log data structure revision number 0
|
||||
Note: revision number not 1 implies that no selective self-test has ever been run
|
||||
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
|
||||
1 0 0 Not_testing
|
||||
2 0 0 Not_testing
|
||||
3 0 0 Not_testing
|
||||
4 0 0 Not_testing
|
||||
5 0 0 Not_testing
|
||||
Selective self-test flags (0x0):
|
||||
After scanning selected spans, do NOT read-scan remainder of disk.
|
||||
If Selective self-test is pending on power-up, resume after 0 minute delay.
|
||||
|
||||
SCT Commands not supported
|
||||
|
||||
Device Statistics (GP Log 0x04)
|
||||
Page Offset Size Value Flags Description
|
||||
0x01 ===== = = === == General Statistics (empty) ==
|
||||
0x04 ===== = = === == General Errors Statistics (empty) ==
|
||||
0x05 ===== = = === == Temperature Statistics (empty) ==
|
||||
0x06 ===== = = === == Transport Statistics (empty) ==
|
||||
0x07 ===== = = === == Solid State Device Statistics (empty) ==
|
||||
|||_ C monitored condition met
|
||||
||__ D supports DSN
|
||||
|___ N normalized value
|
||||
|
||||
Pending Defects log (GP Log 0x0c) not supported
|
||||
|
||||
SATA Phy Event Counters (GP Log 0x11)
|
||||
ID Size Value Description
|
||||
0x0001 2 0 Command failed due to ICRC error
|
||||
0x000a 2 20 Device-to-host register FISes sent due to a COMRESET
|
||||
|
196
SSD/SK hynix/HFS128/HFS128G39TND-N210A/9D841482C1E6
Normal file
196
SSD/SK hynix/HFS128/HFS128G39TND-N210A/9D841482C1E6
Normal file
@@ -0,0 +1,196 @@
|
||||
smartctl 7.4 2023-08-01 r5530 [OpenBSD 7.5 amd64] (local build)
|
||||
Copyright (C) 2002-23, Bruce Allen, Christian Franke, www.smartmontools.org
|
||||
|
||||
=== START OF INFORMATION SECTION ===
|
||||
Model Family: SK hynix SATA SSDs
|
||||
Device Model: HFS128G39TND-N210A
|
||||
Serial Number: --
|
||||
Firmware Version: 30001P10
|
||||
User Capacity: 128,035,676,160 bytes [128 GB]
|
||||
Sector Sizes: 512 bytes logical, 4096 bytes physical
|
||||
Rotation Rate: Solid State Device
|
||||
Form Factor: M.2
|
||||
TRIM Command: Available, deterministic
|
||||
Device is: In smartctl database 7.3/5528
|
||||
ATA Version is: ACS-2 (minor revision not indicated)
|
||||
SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s)
|
||||
Local Time is: Mon May 27 22:04:25 2024 CEST
|
||||
SMART support is: Available - device has SMART capability.
|
||||
SMART support is: Enabled
|
||||
|
||||
=== START OF READ SMART DATA SECTION ===
|
||||
SMART Status not supported: Incomplete response, ATA output registers missing
|
||||
SMART overall-health self-assessment test result: PASSED
|
||||
Warning: This result is based on an Attribute check.
|
||||
|
||||
General SMART Values:
|
||||
Offline data collection status: (0x00) Offline data collection activity
|
||||
was never started.
|
||||
Auto Offline Data Collection: Disabled.
|
||||
Self-test execution status: ( 32) The self-test routine was interrupted
|
||||
by the host with a hard or soft reset.
|
||||
Total time to complete Offline
|
||||
data collection: ( 0) seconds.
|
||||
Offline data collection
|
||||
capabilities: (0x19) SMART execute Offline immediate.
|
||||
No Auto Offline data collection support.
|
||||
Suspend Offline collection upon new
|
||||
command.
|
||||
Offline surface scan supported.
|
||||
Self-test supported.
|
||||
No Conveyance Self-test supported.
|
||||
No Selective Self-test supported.
|
||||
SMART capabilities: (0x0002) Does not save SMART data before
|
||||
entering power-saving mode.
|
||||
Supports SMART auto save timer.
|
||||
Error logging capability: (0x01) Error logging supported.
|
||||
General Purpose Logging supported.
|
||||
Short self-test routine
|
||||
recommended polling time: ( 2) minutes.
|
||||
Extended self-test routine
|
||||
recommended polling time: ( 10) minutes.
|
||||
|
||||
SMART Attributes Data Structure revision number: 0
|
||||
Vendor Specific SMART Attributes with Thresholds:
|
||||
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
|
||||
1 Raw_Read_Error_Rate 0x000f 166 153 006 Pre-fail Always - 0
|
||||
5 Retired_Block_Count 0x0032 100 100 036 Old_age Always - 5
|
||||
9 Power_On_Hours 0x0032 089 089 000 Old_age Always - 10282
|
||||
12 Power_Cycle_Count 0x0032 100 100 020 Old_age Always - 1554
|
||||
100 Total_Erase_Count 0x0032 100 100 000 Old_age Always - 27718900
|
||||
168 Min_Erase_Count 0x0032 023 023 000 Old_age Always - 817
|
||||
169 Max_Erase_Count 0x0032 017 017 000 Old_age Always - 885
|
||||
171 Program_Fail_Count 0x0032 253 253 000 Old_age Always - 0
|
||||
172 Erase_Fail_Count 0x0032 253 253 000 Old_age Always - 0
|
||||
174 Unexpect_Power_Loss_Ct 0x0030 100 100 000 Old_age Offline - 73
|
||||
175 Program_Fail_Count_Chip 0x0032 253 253 000 Old_age Always - 0
|
||||
176 Unused_Rsvd_Blk_Cnt_Tot 0x0032 253 253 000 Old_age Always - 0
|
||||
177 Wear_Leveling_Count 0x0032 021 021 000 Old_age Always - 848
|
||||
178 Used_Rsvd_Blk_Cnt_Chip 0x0032 100 100 000 Old_age Always - 208
|
||||
179 Used_Rsvd_Blk_Cnt_Tot 0x0032 100 100 000 Old_age Always - 431
|
||||
180 Erase_Fail_Count 0x0032 100 100 000 Old_age Always - 2209
|
||||
184 End-to-End_Error 0x0032 100 100 000 Old_age Always - 1326
|
||||
187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 1399
|
||||
188 Command_Timeout 0x0032 253 253 000 Old_age Always - 0
|
||||
194 Temperature_Celsius 0x0002 036 000 000 Old_age Always - 36 (Min/Max 10/53)
|
||||
195 Hardware_ECC_Recovered 0x0032 100 091 000 Old_age Always - 4311110
|
||||
196 Reallocated_Event_Count 0x0032 100 100 036 Old_age Always - 5
|
||||
198 Offline_Uncorrectable 0x0032 100 100 000 Old_age Always - 152
|
||||
199 UDMA_CRC_Error_Count 0x0032 253 253 000 Old_age Always - 0
|
||||
204 Soft_ECC_Correction 0x000e 003 001 000 Old_age Always - 8496
|
||||
212 Phy_Error_Count 0x0032 253 253 000 Old_age Always - 0
|
||||
234 Unknown_SK_hynix_Attrib 0x0032 100 100 000 Old_age Always - 117074
|
||||
241 Total_Writes_GB 0x0032 100 100 000 Old_age Always - 32892
|
||||
242 Total_Reads_GB 0x0032 100 100 000 Old_age Always - 3087
|
||||
250 Read_Retry_Count 0x0032 095 095 000 Old_age Always - 214854686
|
||||
|
||||
SMART Error Log Version: 1
|
||||
ATA Error Count: 181 (device log contains only the most recent five errors)
|
||||
CR = Command Register [HEX]
|
||||
FR = Features Register [HEX]
|
||||
SC = Sector Count Register [HEX]
|
||||
SN = Sector Number Register [HEX]
|
||||
CL = Cylinder Low Register [HEX]
|
||||
CH = Cylinder High Register [HEX]
|
||||
DH = Device/Head Register [HEX]
|
||||
DC = Device Command Register [HEX]
|
||||
ER = Error register [HEX]
|
||||
ST = Status register [HEX]
|
||||
Powered_Up_Time is measured from power on, and printed as
|
||||
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
|
||||
SS=sec, and sss=millisec. It "wraps" after 49.710 days.
|
||||
|
||||
Error 181 occurred at disk power-on lifetime: 10085 hours (420 days + 5 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER ST SC SN CL CH DH
|
||||
-- -- -- -- -- -- --
|
||||
40 41 00 00 00 00 00 Error: UNC at LBA = 0x00000000 = 0
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
||||
-- -- -- -- -- -- -- -- ---------------- --------------------
|
||||
60 20 e8 3c 9e 3d 40 40 01:28:14.740 READ FPDMA QUEUED
|
||||
2f 00 01 10 00 00 00 00 01:28:14.730 READ LOG EXT
|
||||
60 20 e0 3c 9e 3d 40 40 01:28:14.710 READ FPDMA QUEUED
|
||||
2f 00 01 10 00 00 00 00 01:28:14.710 READ LOG EXT
|
||||
60 20 d8 3c 9e 3d 40 40 01:28:14.690 READ FPDMA QUEUED
|
||||
|
||||
Error 180 occurred at disk power-on lifetime: 10085 hours (420 days + 5 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER ST SC SN CL CH DH
|
||||
-- -- -- -- -- -- --
|
||||
40 41 00 00 00 00 00 Error: UNC at LBA = 0x00000000 = 0
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
||||
-- -- -- -- -- -- -- -- ---------------- --------------------
|
||||
60 20 e0 3c 9e 3d 40 40 01:28:14.710 READ FPDMA QUEUED
|
||||
2f 00 01 10 00 00 00 00 01:28:14.710 READ LOG EXT
|
||||
60 20 d8 3c 9e 3d 40 40 01:28:14.690 READ FPDMA QUEUED
|
||||
2f 00 01 10 00 00 00 00 01:28:14.690 READ LOG EXT
|
||||
60 20 d0 3c 9e 3d 40 40 01:28:14.670 READ FPDMA QUEUED
|
||||
|
||||
Error 179 occurred at disk power-on lifetime: 10085 hours (420 days + 5 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER ST SC SN CL CH DH
|
||||
-- -- -- -- -- -- --
|
||||
40 41 00 00 00 00 00 Error: UNC at LBA = 0x00000000 = 0
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
||||
-- -- -- -- -- -- -- -- ---------------- --------------------
|
||||
60 20 d8 3c 9e 3d 40 40 01:28:14.690 READ FPDMA QUEUED
|
||||
2f 00 01 10 00 00 00 00 01:28:14.690 READ LOG EXT
|
||||
60 20 d0 3c 9e 3d 40 40 01:28:14.670 READ FPDMA QUEUED
|
||||
2f 00 01 10 00 00 00 00 01:28:14.670 READ LOG EXT
|
||||
60 20 c8 3c 9e 3d 40 40 01:28:14.650 READ FPDMA QUEUED
|
||||
|
||||
Error 178 occurred at disk power-on lifetime: 10085 hours (420 days + 5 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER ST SC SN CL CH DH
|
||||
-- -- -- -- -- -- --
|
||||
40 41 00 00 00 00 00 Error: UNC at LBA = 0x00000000 = 0
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
||||
-- -- -- -- -- -- -- -- ---------------- --------------------
|
||||
60 20 d0 3c 9e 3d 40 40 01:28:14.670 READ FPDMA QUEUED
|
||||
2f 00 01 10 00 00 00 00 01:28:14.670 READ LOG EXT
|
||||
60 20 c8 3c 9e 3d 40 40 01:28:14.650 READ FPDMA QUEUED
|
||||
61 20 c0 00 0a 25 40 40 01:28:13.810 WRITE FPDMA QUEUED
|
||||
61 20 b8 40 0f 25 40 40 01:28:13.810 WRITE FPDMA QUEUED
|
||||
|
||||
Error 177 occurred at disk power-on lifetime: 10085 hours (420 days + 5 hours)
|
||||
When the command that caused the error occurred, the device was active or idle.
|
||||
|
||||
After command completion occurred, registers were:
|
||||
ER ST SC SN CL CH DH
|
||||
-- -- -- -- -- -- --
|
||||
40 41 00 00 00 00 00 Error: UNC at LBA = 0x00000000 = 0
|
||||
|
||||
Commands leading to the command that caused the error were:
|
||||
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
|
||||
-- -- -- -- -- -- -- -- ---------------- --------------------
|
||||
60 20 c8 3c 9e 3d 40 40 01:28:14.650 READ FPDMA QUEUED
|
||||
61 20 c0 00 0a 25 40 40 01:28:13.810 WRITE FPDMA QUEUED
|
||||
61 20 b8 40 0f 25 40 40 01:28:13.810 WRITE FPDMA QUEUED
|
||||
61 20 b0 80 89 c2 40 40 01:28:13.590 WRITE FPDMA QUEUED
|
||||
61 20 a8 40 89 c2 40 40 01:28:13.590 WRITE FPDMA QUEUED
|
||||
|
||||
SMART Self-test log structure revision number 1
|
||||
No self-tests have been logged. [To run self-tests, use: smartctl -t]
|
||||
|
||||
Selective Self-tests/Logging not supported
|
||||
|
||||
The above only provides legacy SMART information - try 'smartctl -x' for more
|
||||
|
||||
|
||||
|
Reference in New Issue
Block a user